Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Gamma-ray spectra analyses of molten salts in spent nuclear fuels pyroprocessing facilities for mass measurement

To evaluate radioactive tracer dilution and gamma spectroscopy as a safeguards technique for monitoring the mass of liquid salt in molten salt systems, the gamma spectroscopy data of salt samples from the pyroprocessing facilities in Idaho National Laboratory were acquired and analyzed. The primary focus is the uncertainty analysis of the gamma radioactivity of 154 Eu isotope in the molten salts. The facilities include an electrorefiner for pyroprocessing spent oxide fuels (SOF-ER) and Mark-IV ER for processing the metallic fuels from Experimental Breeder Reactor-II (EBR-II). The relative gamma radioactivity uncertainty was consistently at 3% for 137 Cs for both Mark-IV ER and SOF-ER salts. However, for 154 Eu, it was 8% for SOF-ER salt and 7% for Mark-IV ER salt. Here, the main reason for the higher uncertainty for 154 Eu is believed to be the lower counting statistics in gamma spectroscopy. To improve the gamma radioactivity uncertainty of isotope 154 Eu, a longer data acquisition time (12 h instead of 4 h) and a higher count rate gamma detector for gamma spectroscopy were tested and it was found that the uncertainty for 154 Eu was significantly improved from 7% or 8–3%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Six faint gamma-ray pulsars seen with the Fermi Large Area Telescope: Towards a sample blending into the background

Context. Here, GeV gamma-ray pulsations from over 140 pulsars have been characterized using the Fermi Large Area Telescope, enabling improved understanding of the emission regions within the neutron star magnetospheres, and the contributions of pulsars to high energy electrons and diffuse gamma rays in the Milky Way. The first gamma-ray pulsars to be detected were the most intense and/or those with narrow pulses. Aims. As the Fermi mission progresses, progressively fainter objects can be studied. In addition to more distant pulsars (thus probing a larger volume of the Galaxy), or ones in high background regions (thus improving the sampling uniformity across the Galactic plane), we detect pulsars with broader pulses or lower luminosity. Adding pulsars to our catalog with inclination angles that are rare in the observed sample, and/or with lower spindown power, will reduce the bias in the currently known gamma-ray pulsar population. Methods. We use rotation ephemerides derived from radio observations to phase-fold gamma rays recorded by the Fermi Large Area Telescope, to then determine the pulse profile properties. Spectral analysis provides the luminosities and, when the signal-to-noise ratio allows, the cutoff energies. We constrain the pulsar distances by different means in order to minimize the luminosity uncertainties. Results. We present six new gamma-ray pulsars with an eclectic mix of properties. Three are young, and three are recycled. They include the farthest, the lowest power, two of the highest duty-cycle pulsars seen, and only the fourth young gamma-ray pulsar with a radio interpulse. Finally, we discuss the biases existing in the current gamma-ray pulsar catalog, and steps to be taken to mitigate the bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver

Purpose: Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Methods: Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm{sup 3}). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. Results: The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ∼15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ∼75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Conclusions: Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-142: Prompt Gamma Emission Measurements From a Passively Scattered Proton Beam On Targets Containing 16O, 12C and 14N

Purpose: To measure the prompt gamma emission from the important elements found in tissue ({sup 16}O,{sup 12}C and {sup 14}N) in a clinical passive-scatter treatment environment. Methods: The targets (composed of water, Perspex, graphite and liquid nitrogen) were irradiated with a 200 MeV passive-scatter proton beam and the discrete prompt gamma energy spectra was detected by a high resolution 2′ × 2′ LaBr. detector. In order to reduce the high level of radiation produced by the beam line elements, the detector was surrounded by 10 cm of lead to attenuate the scattered gamma-rays entering the detector with an extra 5 cm thick layer of lead added along the beam direction. A 10 cm thick collimator with a 5 cm × 10 cm rectangular opening was also used. Results: The prompt gamma peaks at 6.13 MeV and 4.44 MeV were clearly identified as a Result of the inelastic nuclear reaction between the protons and the 16O atoms found in the water target. The 6.13 MeV peak was 5% higher than the peak at 4.44 MeV for the water target. The 4.44 MeV peak was the only identified emission in the prompt gamma energy spectra from the graphite target ({sup 12}C). The expected 2.313 MeV peak form the{sup 14}N (liquid nitrogen target) was identified, but the other expected {sup 14}N peaks could not be resolved. Conclusion: Prompt gamma measurements with a passive-scatter proton beam are possible, but the presence of a high amount of background radiation from the patient final collimator presents a challenge at the treatment isocenter. The prominent prompt gamma peaks at 6.13 MeV and 4.44 MeV were identified from the water, Perspex and graphite targets. The prompt gammas from the liquid nitrogen target were difficult to see, but may not be significant in the in-vivo verification process.

60 APPLIED LIFE SCIENCES↗

Observation of the Gamma-Ray Binary HESS J0632+057 with the H.E.S.S., MAGIC, and VERITAS Telescopes

The results of gamma-ray observations of the binary system HESS J0632 + 057 collected during 450 hr over 15 yr, between 2004 and 2019, are presented. Data taken with the atmospheric Cherenkov telescopes H.E.S.S., MAGIC, and VERITAS at energies above 350 GeV were used together with observations at X-ray energies obtained with Swift-XRT, Chandra, XMM-Newton, NuSTAR, and Suzaku. Some of these observations were accompanied by measurements of the Hα emission line. A significant detection of the modulation of the very high-energy gamma-ray fluxes with a period of 316.7 ± 4.4 days is reported, consistent with the period of 317.3 ± 0.7 days obtained with a refined analysis of X-ray data. The analysis of data from four orbital cycles with dense observational coverage reveals short-timescale variability, with flux-decay timescales of less than 20 days at very high energies. Flux variations observed over a timescale of several years indicate orbit-to-orbit variability. The analysis confirms the previously reported correlation of X-ray and gamma-ray emission from the system at very high significance but cannot find any correlation of optical H$α$ parameters with fluxes at X-ray or gamma-ray energies in simultaneous observations. The key finding is that the emission of HESS J0632 + 057 in the X-ray and gamma-ray energy bands is highly variable on different timescales. The ratio of gamma-ray to X-ray flux shows the equality or even dominance of the gamma-ray energy range. This wealth of new data is interpreted taking into account the insufficient knowledge of the ephemeris of the system and discussed in the context of results reported on other gamma-ray binary systems.

79 ASTRONOMY AND ASTROPHYSICS↗

The Third Fermi Large Area Telescope Catalog of Gamma-Ray Pulsars

We present 294 pulsars found in GeV data from the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope. Another 33 millisecond pulsars (MSPs) discovered in deep radio searches of LAT sources will likely reveal pulsations once phase-connected rotation ephemerides are achieved. A further dozen optical and/or X-ray binary systems colocated with LAT sources also likely harbor gamma-ray MSPs. This catalog thus reports roughly 340 gamma-ray pulsars and candidates, 10% of all known pulsars, compared to ≤11 known before Fermi. Half of the gamma-ray pulsars are young. Of these, the half that are undetected in radio have a broader Galactic latitude distribution than the young radio-loud pulsars. The others are MSPs, with six undetected in radio. Overall, ≥236 are bright enough above 50 MeV to fit the pulse profile, the energy spectrum, or both. For the common two-peaked profiles, the gamma-ray peak closest to the magnetic pole crossing generally has a softer spectrum. The spectral energy distributions tend to narrow as the spindown power $\dot{E}$ decreases to its observed minimum near 10 33 erg s -1 , approaching the shape for synchrotron radiation from monoenergetic electrons. We calculate gamma-ray luminosities when distances are available. Our all-sky gamma-ray sensitivity map is useful for population syntheses. The electronic catalog version provides gamma-ray pulsar ephemerides, properties, and fit results to guide and be compared with modeling results.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining gamma-ray emission from luminous infrared galaxies with Fermi-LAT; tentative detection of ARP 220

Star-forming galaxies produce gamma-rays primarily via pion production, resulting from inelastic collisions between cosmic-ray protons and the interstellar medium (ISM). The dense ISM and high star formation rates of luminous and ultra-luminous infrared galaxies (LIRGs and ULIRGs) imply that they should be strong gamma-ray emitters, but so far only two LIRGs have been detected. Theoretical models for their emission depend on the unknown fraction of cosmic-ray protons that escape these galaxies before interacting. We analyze Fermi-LAT data for 82 of the brightest Infrared Astronomical Satellite LIRGs and ULIRGs. We examine each system individually and carry out a stacking analysis to constrain their gamma-ray fluxes. We report the detection of the nearest ULIRG Arp 220 (∼4.6σ). We observe a gamma-ray flux (0.8–100 GeV) of 2.4 × 10{sup −10} phot cm{sup −2} s{sup −1} with a photon index of 2.23 (8.2 × 10{sup 41} erg s{sup −1} at 77 Mpc). We also derive upper limits (ULs) for the stacked LIRGs and ULIRGs. The gamma-ray luminosity of Arp 220 and the stacked ULs agree with calorimetric predictions for dense star-forming galaxies. With the detection of Arp 220, we extend the gamma-ray–IR luminosity correlation to the high-luminosity regime with logL{sub 0.1−100GeV}=1.25×logL{sub 8−1000μm}+26.7 as well as the gamma-ray–radio continuum luminosity correlation with logL{sub 0.1−100GeV}=1.22×logL{sub 1.4GHz}+13.3. The current survey of Fermi-LAT is on the verge of detecting more LIRGs/ULIRGs in the local universe, and we expect even more detections with deeper Fermi-LAT observations or the next generation of gamma-ray detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory’s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation - 18594

The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Effect of Localized Pin Flux on Short-Term Gamma Intensities of Spent Fuel Assemblies

Nuclear reactor operation for electricity generation involves irradiation of a fuel assembly for an extended period of time until a certain burnup is achieved. To harness the full nuclear energy potential and flatten the flux around the core, fuel assemblies are shuffled to one or more different locations within the core. Post-irradiation practice typically involves storing the spent fuel assembly in a spent fuel pool. While in the spent fuel pool, aspects of the fuel assembly continue to evolve, particularly the isotopic concentration as nuclides decay. Numerous nondestructive assay (NDA) safeguards techniques exist and have been proposed for performing verification on spent fuel assemblies to ensure they have not been tampered with. Adigun et al. recently proposed measuring both the neutron and gamma signatures from spent fuel from discharge to final disposal, however, the research in only investigated the neutron part of this approach. In the conclusion, the authors caveated the need for the gamma results to make more certain conclusions about a spent fuel assembly, as a combination of the neutron and gamma NDA measurements will limit the range of possible initial enrichment and burnup combinations. This paper focuses on the production of the gamma source. It is important to understand the driving mechanisms behind the emissions signatures at shutdown and after long cooling time periods, to better determine the correlation between the measured passive gamma emission spectra and the gamma emissions per second of the assembly. The objective is to demonstrate how the effect of localized flux within a reactor affects the gamma emissions per second (or gamma intensity) present in an assembly at shutdown. This study examined the photons emitted from the nuclides present within the fuel assembly, and not the photons escaping from the fuel assembly. The latter point of transporting the photons present within the spent fuel assemblies to an appropriate detector will be addressed in a future paper. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Code of Radiation Damage by Gamma - Paper 62

In recent years, the study of radiation damage of materials has seen a thrust because of the expectation of the high rate of radiation damage in fusion reactors, accelerator driven sub critical systems and damage of a control system of space vehicles by the high energy neutrons and gamma showers. Embrittlement of reactor vessels, corrosion of steel and swelling of fuel rods are the well known empirical examples of severe radiation damage. It is also realized that damage by high energy gammas is in no way insignificant, and it is equivalent to the damage by the neutrons. Secondly, value addition of certain materials like enhancement of electrical resistance, mechanical strength, color enhancement of precious stones on irradiation by neutrons and gammas and polymerization in the presence of gamma radiation add to the necessity of a Monte Carlo (MC) code of radiation damage in a wide range of energy. The JAIPU code, for the study of radiation damage by neutrons up to 10 MeV energy, incorporates features like development of secondary atomic cascade and PKA energy corrected for the ionization lose and production of Frenkel pair. MC estimation of both the primary and secondary displacements has been compared with the Frenkel pairs calculated using the NRT model. In the present work, JAIPU code is extended for irradiation of materials by high energy gammas. Here cascade generated by the incident gamma produces electrons by way of photo-electric, Compton and pair production until it is absorbed. The recoiled Frenkel pairs produced in electron + atom collision have been considered for the purpose of atomic cascade. Standard cross section libraries for gamma and electron interaction are used while for atom + atom collision we have made use of the IOTA code. In addition, in the code, the lattice structure of the irradiated material is simulated to know the positions of the photon interactions with atoms and the energy of electron it adds an extra feature of the position and size of the voids and the clusters produced on irradiation. The code has the possibility of calculation of 'absorbed radiation dose' and 'KERMA' and the interatomic distances of the displaced atoms. It may be pointed out that the code uses only the MC simulation of the number of displacements unlike several other approaches where the NRT model with PKA energy is used for gross estimation of the number of the displaced atoms. Thus, the code keeps an account of the positions of displaced atoms for the in-depth modification of the irradiated material. 1 MeV gamma seems to damage Fe up to several millimeters of its depth and this is mostly by the recoiled Compton electrons than photo electrons. The code is in the developmental stage and it has the capability of applications in the developing field of Radiology besides the shielding and other studies of radiation damage. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A multi-frequency analysis of possible dark matter contributions to M31 gamma-ray emissions

We examine the possibility of a dark matter (DM) contribution to the recently observed gamma-ray spectrum seen in the M31 galaxy. In particular, we apply limits on Weakly Interacting Massive Particle DM annihilation cross-sections derived from the Coma galaxy cluster and the Reticulum II dwarf galaxy to determine the maximal flux contribution by DM annihilation to both the M31 gamma-ray spectrum and that of the Milky-Way Galactic Centre. We limit the energy range between 1 and 12 GeV in M31 and Galactic Centre spectra due to the limited range of former's data, as well as to encompass the high-energy gamma-ray excess observed in the latter target. In so doing, we will make use of Fermi-LAT data for all mentioned targets, as well as diffuse radio data for the Coma cluster. The multi-target strategy using both Coma and Reticulum II to derive cross-section limits, as well as multi-frequency data, ensures that our results are robust against the various uncertainties inherent in modelling of indirect DM emissions. Our results indicate that, when a Navarro-Frenk-White (or shallower) radial density profile is assumed, severe constraints can be imposed upon the fraction of the M31 and Galactic Centre spectra that can be accounted for by DM, with the best limits arising from cross-section constraints from Coma radio data and Reticulum II gamma-ray limits. These particular limits force all the studied annihilation channels to contribute 1% or less to the total integrated gamma-ray flux within both M31 and Galactic Centre targets. In contrast, considerably more, 10−100%, of the flux can be attributed to DM when a contracted Navarro-Frenk-White profile is assumed. This demonstrates how sensitive DM contributions to gamma-ray emissions are to the possibility of cored profiles in galaxies. The only channel consistently excluded for all targets and profiles (except for ∼ 10 GeV WIMPs) is the direct annihilation into photons. Finally, we discuss the ramifications of evidence in favour of cored halo density profiles for DM explanations of galactic gamma-ray emission.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-594: Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

Purpose: Secondary fast neutrons and gamma rays are mainly produced due to the interaction of the primary proton beam with the beam delivery nozzle. These secondary radiation dose to patients and radiation workers are unwanted. The purpose of this study is to estimate the neutron and gamma dose equivalent out of the treatment volume during the wobbling proton therapy system. Methods: Two types of thermoluminescent (TL) dosimeters, TLD-600 ({sup 6}LiF: Mg, Ti) and TLD-700 ({sup 7}LiF: Mg, Ti) were used in this study. They were calibrated in the standard neutron and gamma sources at National Standards Laboratory. Annealing procedure is 400°C for 1 hour, 100°C for 2 hours and spontaneously cooling down to the room temperature in a programmable oven. Two-peak method (a kind of glow curve analysis technique) was used to evaluate the TL response corresponding to the neutron and gamma dose. The TLD pairs were placed outside the treatment field at the neutron-gamma mixed field with 190-MeV proton beam produced by the wobbling system through the polyethylene plate phantom. The results of TLD measurement were compared to the Monte Carlo simulation. Results: The initial experiment results of calculated dose equivalents are 0.63, 0.38, 0.21 and 0.13 mSv per Gy outside the field at the distance of 50, 100, 150 and 200 cm. Conclusion: The TLD-600 and TLD-700 pairs are convenient to estimate neutron and gamma dosimetry during proton therapy. However, an accurate and suitable glow curve analysis technique is necessary. During the wobbling system proton therapy, our results showed that the neutron and gamma doses outside the treatment field are noticeable. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)

61 RADIATION PROTECTION AND DOSIMETRY↗

Search for gamma-ray emission from Galactic novae with the Fermi -LAT

Context. A number of novae have been found to emit high-energy gamma rays (>100 MeV). However, the origin of this emission is not yet understood. We report on the search for gamma-ray emission from 75 optically detected Galactic novae in the first 7.4 years of operation of the Fermi Large Area Telescope using the Pass 8 data set. Aims. We compile an optical nova catalog including light curves from various resources and estimate the optical peak time and optical peak magnitude in order to search for gamma-ray emission to determine whether all novae are gamma-ray emitters. Methods. We repeated the analysis of the six novae previously identified as gamma-ray sources and developed a unified analysis strategy that we then applied to all novae in our catalog. We searched for emission in a 15 day time window in two-day steps ranging from 20 days before to 20 days after the optical peak time. We performed a population study with Monte Carlo simulations to set constraints on the properties of the gamma-ray emission of novae. Results. Two new novae candidates have been found at ~ 2σ global significance. Although these two novae candidates were not detected at a significant level individually, taking them together with the other non-detected novae, we found a sub-threshold nova population with a cumulative 3σ significance. We report the measured gamma-ray flux for detected sources and flux upper limits for novae without significant detection. Lastly, our results can be reproduced by several gamma-ray emissivity models (e.g., a power-law distribution with a slope of 2), while a constant emissivity model (i.e., assuming novae are standard candles) can be rejected.

79 ASTRONOMY AND ASTROPHYSICS↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Mapping the cosmic gamma-ray horizon: the 1CGH catalogue of Fermi -LAT detections above 10 GeV

ABSTRACT We present the First Cosmic Gamma-ray Horizon (1CGH) catalogue, featuring $\gamma$-ray detections above 10 GeV based on 16 yr of observations with the Fermi Large Area Telescope (Fermi-LAT) satellite. After carefully selecting a sample of blazars and blazar candidates from catalogues in the literature, we performed a binned likelihood analysis and identified 2791 $\gamma$-ray emitters above 10 GeV, at >3$\sigma$ level, including 62 that are new $\gamma$-ray detections. For each source, we estimated the mean energy of the highest energy bin and analysed them in the context of the cosmic gamma-ray horizon. By adopting a reference model for the extragalactic background light (EBL), we identified a subsample of 525 sources where moderate to severe $\gamma$-ray absorption could be detected across the redshift range of 0–3. This work provides the most up-to-date compilation of detections above 10 GeV, along with their redshift information. We condense extensive results from the literature, including reports on observational campaigns dedicated to blazars and $\gamma$-ray sources, thereby delivering an unprecedented review of the redshift information for sources detected above 10 GeV. Additionally, we highlight key 1CGH sources where redshift information remains incomplete, offering guidance for future optical observation campaigns. The 1CGH catalogue aims to track the most significant sources for studying the $\gamma$-ray transparency of the Universe. Furthermore, it provides a targeted subsample where the EBL optical depth, $\tau _{(E,z)}$, can be robustly measured using Fermi-LAT data.

Arsioli, Bruno (ORCID:0000000181666602)↗

SU-E-T-77: Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans

Purpose: Patient-specific QA procedures for IMRT and VMAT are traditionally performed by comparing TPS calculations with measured single point values and plane dose distributions by means of gamma analysis. New QA devices permit us to calculate 3D dose distributions on patient anatomy as redundant secondary check and reconstruct it from measurements taken with 2D and 3D detector arrays. 3D dose calculations allow us to perform DVH-based comparisons with clinical relevance, as well as 3D gamma analysis. One of these systems (Compass, IBA Dosimetry) combines traditional 2D with new anatomical-based 3D gamma analysis. This work shows the ability of this system by comparing 2D and 3D gamma analysis in pre-treatment QA for several VMAT prostate plans. Methods: Compass is capable of calculating dose as secondary check from DICOM TPS data and reconstructing it from measurements taken by a 2D ion chamber array (MatriXX Evolution, IBA Dosimetry). Both 2D and 3D gamma tests are available to compare calculated and reconstructed dose in Compass with TPS RT Dose. Results: 15 VMAT prostate plans have been measured with Compass. Dose is reconstructed with Compass for these plans. 2D gamma comparisons can be done for any plane from dose matrix. Mean gamma passing rates for isocenter planes (axial, coronal, sagittal) are (99.7±0.2)%, (99.9±0.1)%, (99.9±0.1)% for reconstructed dose planes. 3D mean gamma passing rates are (98.5±1.7)% for PTVs, (99.1±1.5)% for rectum, (100.0±0.0)% for bladder, (99.6±0.7)% for femoral heads and (98.1±4.1)% for penile bulb. Conclusion: Compass is a powerful tool to perform a complete pre-treatment QA analysis, from 2D techniques to 3D DVH-based techniques with clinical relevance. All reported values for VMAT prostate plans are in good agreement with TPS values. This system permits us to ensure the accuracy in the delivery of VMAT treatments completing a full patient-specific QA program.

60 APPLIED LIFE SCIENCES↗

SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗