Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

LiOH corrosion growth and thermal stability investigated by diffuse reflectance infrared Fourier Transform (DRIFT) spectroscopy

In this period, we have measured the kinetics of LiOH corrosion growth on LiH substrate at 35 ppm of moisture for over 2 months. The serial DRIFT spectra are being analyzed to build the growth kinetics for LiOH interfacial states, surface states, and bulk states. Physical chemistry insight is being employed to describe the observed parabolic-linear growth of the corrosion layer grown on LiH samples that have been previously vacuum baked then re-exposed to low moisture over a long time. The thermal stabilities of LiOH interfacial states, surface states, and bulk states are also being quantified by measuring the reduction in LiOH DRIFT signals as a function of vacuum level and temperature, and will be needed to add an on/off switch to the current outgassing modeling.

36 MATERIALS SCIENCE↗

Wave-Optics Simulation Framework of Fourier Transform Holography with XMCD

We present a wave-optics simulation framework, implemented within the SRW, for modeling FTH with XMCD contrast. The framework propagates coherent, circularly polarized X-ray wavefronts from an undulator source through the sample and optics to the detector, reconstructing real-space images from the resulting holograms. Three principal extensions are introduced: (i) incorporation of polarization-dependent refractive indices in the sample plane, enabling direct simulation of XMCD contrast, (ii) a memory-efficient wavefront-splitting propagation scheme that treats individual apertures independently and coherently combines their fields at detector, and (iii) an integrated reconstruction module that delivers holographic images within the same framework. Together, these advances establish a versatile tool for quantitative exploration of coherence, aperture geometry, and detector sampling, and for the design and interpretation of XMCD-FTH experiments at synchrotron beamlines.

43 PARTICLE ACCELERATORS↗

Quantum Fourier Transform with Leakage Control

In circuit QED (cQED) systems, one can manipulate the cavity Fock states to use quantum processing unit (QPU). Since the coherence times of the Fock states are long, qudit based computation can be possible. One of the most basic gate that can be engineered in this cQED platform is the displacement gate, $D(\alpha)$. However, accessible number of qudit-levels is finite. The truncated displacement gate on the qudit is the source of theoretical error above the logical states and needs to be addressed. In this work, we monitor and minimize the leakage in qudit systems that involves displacement gate by introducing so-called `bumper' states and a modified cost function.

Kurkcuoglu, D. [Fermilab] (ORCID:0000000311097074)↗

Continuous Fourier transform system

Complex digital computer is not required, only summing amplifiers and attenuators are used for transformation of signal. Continuous transform system may be used for spectrum analysis, filtering, transfer function synthesis, and communications.

Munoz, R. M.↗

An investigation of the optimization of parameters affecting the implementation of fourier transform spectroscopy at 20-500 micron from the C-141 airborne infrared observatory

A program for 20-500 micron spectroscopy from the NASA flying C141 infrared observatory is being carried out with a Michelson interferometer. The parameters affecting the performance of the instrument are studied and an optimal configuration for high performance on the C-141 aircraft is recommended. As each parameter is discussed the relative merits of the two modes of mirror motion (rapid scan or step and integrate) are presented.

Thompson, R. I.↗

Study of dynamic emission spectra from lubricant films in an elastohydrodynamic contact using Fourier transform spectroscopy

Infrared emission spectra were obtained through a diamond window from lubricating fluids in an operating sliding elastohydrodynamic contact and analyzed by comparison with static absorption spectra under similar pressures. Different loads, shear rates and temperatures were used. Most of the spectra exhibited polarization characteristics, indicating directional alignment of the lubricant in the EHD contact. Among the fluids studied were a "traction" fluid, an advanced ester, and their mixtures, a synthetic paraffin, a naphthenic reference fluid (N-1), both neat and containing 1 percent of p-tricresyl phosphate as an anti-wear additive, and a C-ether. Traction properties were found to be nearly proportional to mixture composition for traction fluid and ester mixtures. The anti-wear additive reduced traction and fluid temperature under low loads but increased them under higher loads, giving rise to formation of a friction polymer.

Lauer, J. L.↗

Airborne infrared astronomical observations by Fourier transform spectroscopy

Infrared spectroscopic observations from NASA-operated aircraft constitute a rapidly maturing application of FTS methods initially developed for ground-based telescopes. Coupled to airborne telescopes up to 36 in. in diameter, these experiments are now producing new astronomical results as exciting and unexpected as those derived from Connes's first high resolution planetary observations at mountain-top observatories. This review examines the special problems of the IR spectral region that led to aircraft observatories and includes a brief survey of the facilities themselves and their modes of operation. The special problems of operating FTS devices on aircraft and the scientific results achieved with current capabilities are discussed. Finally, airborne observations are compared to the ultimate in high-altitude observing platforms: earth-orbiting cooled and uncooled telescopes carried by the Space Shuttle vehicle.

Larson, H. P.↗

The determination of gravity anomalies from geoid heights using the inverse Stokes' formula, Fourier transforms, and least squares collocation

A numerical method for the determination of gravity anomalies from geoid heights is described using the inverse Stokes formula. This discrete form of the inverse Stokes formula applies a numerical integration over the azimuth and an integration over a cubic interpolatory spline function which approximates the step function obtained from the numerical integration. The main disadvantage of the procedure is the lack of a reliable error measure. The method was applied on geoid heights derived from GEOS-3 altimeter measurements in the calibration area of the GEOS-3 satellite.

Rummel, R.↗

Faster fourier transformation: The algorithm of S. Winograd

The new DFT algorithm of S. Winograd is developed and presented in detail. This is an algorithm which uses about 1/5 of the number of multiplications used by the Cooley-Tukey algorithm and is applicable to any order which is a product of relatively prime factors from the following list: 2,3,4,5,7,8,9,16. The algorithm is presented in terms of a series of tableaus which are convenient, compact, graphical representations of the sequence of arithmetic operations in the corresponding parts of the algorithm. Using these in conjunction with included Tables makes it relatively easy to apply the algorithm and evaluate its performance.

Zohar, S.↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗