Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

In situ high-temperature Raman spectroscopy for online EAF slag analysis

Real-time monitoring of slag chemistry is critical for optimizing Electric Arc Furnace (EAF) steelmaking operations, where dynamic variations in slag composition directly influence slag foaming, refractory degradation, and thermal efficiency. Conventional techniques such as X-ray fluorescence (XRF), Fourier-transform infrared (FTIR), and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS) are commonly used to analyze slag composition, but their offline nature and equipment constraints limit their applicability for online monitoring in harsh industrial environments. To address this challenge, we present an in situ, high-temperature analytical approach that integrates Raman spectroscopy with a custom designed fiber-optic probe for real-time slag characterization at 1550 °C. The system enables non destructive spectral acquisition from molten slags, providing molecular-level insights into silicate polymerization and iron oxidation states. Eight synthetic slag samples were evaluated, and key Raman features—such as Q n silicate units and FeO₄/FeO₆ coordination environments—were identified and quantitatively correlated with slag basicity and Fe₂O₃ content. The results demonstrate agreement between Raman spectral ratios and bulk slag chemistry, validating the method’s capability to track compositional and structural changes under molten temperature. This work establishes the feasibility of deploying fiber-optic Raman probe for online EAF slag monitoring and highlights their potential to support closed-loop control strategies, thereby enhancing process stability, refractory protection, and steel quality in industrial steelmaking applications.

47 OTHER INSTRUMENTATION↗

High-dimensional discrete Fourier transform gates with a quantum frequency processor

The discrete Fourier transform (DFT) is of fundamental interest in photonic quantum information, yet the ability to scale it to high dimensions depends heavily on the physical encoding, with practical recipes lacking in emerging platforms such as frequency bins. In this article, we show that d -point frequency-bin DFTs can be realized with a fixed three-component quantum frequency processor (QFP), simply by adding to the electro-optic modulation signals one radio-frequency harmonic per each incremental increase in d . We verify gate fidelity F W > 0.9997 and success probability P W > 0.965 up to d = 10 in numerical simulations, and experimentally implement the solution for d = 3, utilizing measurements with parallel DFTs to quantify entanglement and perform tomography of multiple two-photon frequency-bin states. Our results furnish new opportunities for high-dimensional frequency-bin protocols in quantum communications and networking.

97 MATHEMATICS AND COMPUTING↗

Dynamic interferometer alignment and its utility in UV Fourier transform spectrometer systems

Dynamic alignment has been demonstrated as a practical approach to alignment maintenance for systems in the infrared region of the spectrum. On the basis of work done by OPTRA, this technique was introduced in commercial Fourier transform spectrometer systems in 1982 and in various forms is now available from a number of manufacturers. This paper reports on work by OPTRA to extend the basic technique to systems operating in the ultraviolet. In addition, this paper reports the preliminary results of the development of an alignment system using a laser diode in place of a gas laser normally found in dynamic alignment systems. A unique optical system and spatial heterodyne technique allows for achievement of a metrology system with characteristics that fully satisfy the requirements of an ultraviolet spectrometer system.

Dorval, Rick K.↗

Performance of the FOS and GHRS Pt/(Cr)-Ne Hollow-cathode Lamps after their Return from Space and Comparison with Archival Data

The Space Telescope European Coordinating Facility (ST-ECF) and National Institute of Standards and Technology (NIST) are collaborating to study hollow cathode calibration lamps as used onboard the Hubble Space Telescope (HST). As part of the STIS Calibration Enhancement (STIS-CE) Project we are trying to improve our understanding of the performance of hollow cathode lamps and the physical processes involved in their long term operation. The original flight lamps from the Faint Object Spectrograph (FOS) and the Goddard High Resolution Spectrograph (GHRS) are the only lamps that have ever been returned to Earth after extended operation in space. We have taken spectra of all four lamps using NIST s 10.7-m normal-incidence spectrograph and Fourier transform spectrometer (FTS) optimized for use in the ultraviolet (UV). These spectra, together with spectra archived from six years of on-orbit operations and pre-launch spectra, provide a unique data set - covering a period of about 20 years - for studying aging effects in these lamps. Our findings represent important lessons for the choice and design of calibration sources and their operation in future UV and optical spectrographs in space.

Kerber, Florian↗

Towards a heat- and mass-balanced kinetic model of TATB decomposition

We report TATB (1,3,5-triamino-2,4,6-trinitrobenzene) was thermally degraded by two small-scale analytical methods – simultaneous differential scanning calorimetry and thermogravimetric analysis (SDT) and a hot-stage microscope with Fourier Transform Infrared (FTIR) analysis capabilities. SDT used ramped heating, isothermal soaking, and thermal pretreatment at various conditions. The heat flow and mass loss were monitored during various treatment conditions to derive chemical decomposition kinetics and Arrhenius parameters. FTIR experiments used isothermal heating, and changes were monitored spectroscopically. Solid samples generated at specific conditions were collected from both methods and were analyzed by DMSO extraction followed by chemical speciation by optical and mass spectrometric methods. Characterization provided the following reaction insights: TATB decreases in a sigmoidal pattern in isothermally heated samples. Other soluble products gradually increase in concentration and then abruptly decline in concentration during the second exotherm, such as diamino-dinitro-benzofurazan and amino-nitro-benzodifurazan. FTIR showed gradual changes in the amino and nitro functionality, shifting positions and decreasing intensity for the first 40 min. Then the solid gradually appeared more like an amorphous C with N incorporated, similar to previous studies on thermally degraded TATB-type materials. Extracted residues (DMSO-soluble components removed) examined by FTIR showed an abrupt change in chemical composition between 40- and 45-min isothermal treatment, indicating early forming solids are different than later forming residues. A reliable mass- and energy-balanced global reaction network must include at least two autocatalytic reactions, either in parallel or series, and at least one must have an explicit initiation reaction having a low activation energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Electro optical performance of an improved deformable mirror device

The design, fabrication, and performance of an improved 128 x 128 deformable mirror device (DMD) are discussed. The present DMD consists of a monolithically formed array of cantilever beams which are electrostatically deflected by an underlying MOS transistor address matrix. In contrast to an earlier version, the improved DMD on-chip address circuitry supports a single video input to the chip, with all demux operations performed on-chip. The cantilever beams are formed by two layers of high-reflectivity aluminum alloy. The dynamic range of the DMD in the Fourier plane at the Nyquist frequency has been determined at greater than 45 dB.

Wu, Wen R.↗

Large area projection liquid-crystal video display system with inherent grid pattern optically removed

A relatively small and low-cost system is provided for projecting a large and bright television image onto a screen. A miniature liquid crystal array is driven by video circuitry to produce a pattern of transparencies in the array corresponding to a television image. Light is directed against the rear surface of the array to illuminate it, while a projection lens lies in front of the array to project the image of the array onto a large screen. Grid lines in the liquid crystal array are eliminated by a spacial filter which comprises a negative of the Fourier transform of the grid.

Liu, Hua-Kuang↗

Ultra-high Temperature Emittance Measurements for Space and Missile Applications

Advanced modeling and design efforts for many aerospace components require high temperature emittance data. Applications requiring emittance data include propulsion systems, radiators, aeroshells, heatshields/thermal protection systems, and leading edge surfaces. The objective of this work is to provide emittance data at ultra-high temperatures. MSFC has a new instrument for the measurement of emittance at ultra-high temperatures, the Ultra-High Temperature Emissometer System (Ultra-HITEMS). AZ Technology Inc. developed the instrument, designed to provide emittance measurements over the temperature range 700-3500K. The Ultra-HITEMS instrument measures the emittance of samples, heated by lasers, in vacuum, using a blackbody source and a Fourier Transform Spectrometer. Detectors in a Nicolet 6700 FT-IR spectrometer measure emittance over the spectral range of 0.4-25 microns. Emitted energy from the specimen and output from a Mikron M390S blackbody source at the same temperature with matched collection geometry are measured. Integrating emittance over the spectral range yields the total emittance. The ratio provides a direct measure of total hemispherical emittance. Samples are heated using lasers. Optical pyrometry provides temperature data. Optical filters prevent interference from the heating lasers. Data for Inconel 718 show excellent agreement with results from literature and ASTM 835. Measurements taken from levitated spherical specimens provide total hemispherical emittance data; measurements taken from flat specimens mounted in the chamber provide near-normal emittance data. Data from selected characterization studies will be presented. The Ultra-HITEMS technique could advance space and missile technologies by advancing the knowledge base and the technology readiness level for ultra-high temperature materials.

Rogers, Jan↗

Evaluation of ERTS-1 image sensor spatial resolution in photographic form

The author has identified the following significant results. The digital Optical Transfer Function (OTF) measurements showed the following: (1) there are no significant differences in optical performance, in terms of OTF, among all four bands of the multispectral scanner, (2) no substantial changes in the OTF's of bands 4, 5, and 6 during the period November 1972 to May 1973, and (3) comparison between the photographic and digital (CCT) two-dimensional OTF's indicated a strong asymmetry in the photographic product OTF between the MSS scan direction and across scan direction. The coherent light Fourier analysis program showed the following: (1) for agricultural areas, bands 5 and 7 of the MSS are superior in terms of image definition, and therefore mapping and acreage estimation, (2) amplitude modulation in imagery from MSS bands 4 and 5 is between 65 to 90 percent of that in corresponding bands of Apollo 9 imagery (SO65), and (3) MSS band 5 imagery has a ground resolution between 55 to 75 percent of that exhibited in the corresponding band of Apollo 9 imagery (SO65).

Slater, P. N.↗

Measuring Directional Wave Spectra and Wind Speed with a Scanning Radar Altimeter

The geometry for the NASA Scanning Radar Altimeter (SRA) is shown. It transmits a 8-ns duration pulse at Ka-band (8.3 mm) and measures time of flight as it scans a 1 degree (two-way) beam from left to right across the aircraft ground track. The most recent configuration determines the surface elevation at 64 points spaced at uniform angular intervals of about 0.7 across a swath whose width is about 0.8 times the aircraft altitude. The system generates these raster lines of the surface topography beneath the aircraft at about a 10 Hz rate. In postflight processing the SRA wave topographic data are transformed with a two-dimensional Fast Fourier Transformation (FFT) and Doppler corrected to produce directional wave spectra. The SRA is not absolutely calibrated in power, but by measuring the relative fall-off of backscatter with increasing incidence angle, the SRA can also determine the mean square slope (mss) of the sea surface, a surrogate for wind speed. For the slope-dependent specular point model of radar sea surface scattering, an expression approximated by a geometric optics form, for the relative variation with incidence angle of the normalized backscatter radar cross section would be sigma (sup 0) (sub rel) = sec (exp 4) theta exp (-tan squared theta/mss) where theta is the off-nadir incidence angle.

Walsh, E. J.↗

The Fourier-Kelvin Stellar Interferometer a Low Complexity, Low Cost Space Mission for High-Resolution Astronomy and Direct Exoplanet Detection

The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for a spacecraft-borne nulling interferometer for high-resolution astronomy and the direct detection of exoplanets and assay of their environments and atmospheres. FKSI is a high angular resolution system operating in the near to midinfrared spectral region and is a scientific and technological pathfinder to the Darwin and Terrestrial Planet Finder (TPF) missions. The instrument is configured with an optical system consisting, depending on configuration, of two 0.5 - 1.0 m telescopes on a 12.5 - 20 m boom feeding a symmetric, dual Mach- Zehnder beam combiner. We report on progress on our nulling testbed including the design of an optical pathlength null-tracking control system and development of a testing regime for hollow-core fiber waveguides proposed for use in wavefront cleanup. We also report results of integrated simulation studies of the planet detection performance of FKSI and results from an in-depth control system and residual optical pathlength jitter analysis.

Barry, R. K.↗

Cryogenic Scan Mechanism for Fourier Transform Spectrometer

A compact and lightweight mechanism has been developed to accurately move a Fourier transform spectrometer (FTS) scan mirror (a cube corner) in a near-linear fashion with near constant speed at cryogenic temperatures. This innovation includes a slide mechanism to restrict motion to one dimension, an actuator to drive the motion, and a linear velocity transducer (LVT) to measure the speed. The cube corner mirror is double-passed in one arm of the FTS; double-passing is required to compensate for optical beam shear resulting from tilting of the moving cube corner. The slide, actuator, and LVT are off-the-shelf components that are capable of cryogenic vacuum operation. The actuator drives the slide for the required travel of 2.5 cm. The LVT measures translation speed. A proportional feedback loop compares the LVT voltage with the set voltage (speed) to derive an error signal to drive the actuator and achieve near constant speed. When the end of the scan is reached, a personal computer reverses the set voltage. The actuator and LVT have no moving parts in contact, and have magnetic properties consistent with cryogenic operation. The unlubricated slide restricts motion to linear travel, using crossed roller bearings consistent with 100-million- stroke operation. The mechanism tilts several arc seconds during transport of the FTS mirror, which would compromise optical fringe efficiency when using a flat mirror. Consequently, a cube corner mirror is used, which converts a tilt into a shear. The sheared beam strikes (at normal incidence) a flat mirror at the end of the FTS arm with the moving mechanism, thereby returning upon itself and compensating for the shear

Brasunas, John C.↗

On the convergence of the coupled-wave approach for lamellar diffraction gratings

Among the many existing rigorous methods for analyzing diffraction of electromagnetic waves by diffraction gratings, the coupled-wave approach stands out because of its versatility and simplicity. It can be applied to volume gratings and surface relief gratings, and its numerical implementation is much simpler than others. In addition, its predictions were experimentally validated in several cases. These facts explain the popularity of the coupled-wave approach among many optical engineers in the field of diffractive optics. However, a comprehensive analysis of the convergence of the model predictions has never been presented, although several authors have recently reported convergence difficulties with the model when it is used for metallic gratings in TM polarization. Herein, three points are made: (1) in the TM case, the coupled-wave approach converges much slower than the modal approach of Botten et al; (2) the slow convergence is caused by the use of Fourier expansions for the permittivity and the fields in the grating region; and (3) is manifested by the slow convergence of the eigenvalues and the associated modal fields. The reader is assumed to be familiar with the mathematical formulations of the coupled-wave approach and the modal approach.

Li, Lifeng↗

Direct 75 milliarcsecond images from the Multiple Mirror Telescope with adaptive optics

We report results from an adaptive optics system designed to provide imaging at the diffraction limit of resolution in the near-infrared at the Multiple Mirror Telescope (MMT). For the present experiment, the aperture consisted of five of the six primary mirrors of the MMT, operating as a coherently phased array. The largest components of the atmospherically induced wave-front aberration are the fluctuations in mean phase between the segments. These errors were derived in real time from the Fourier transform of short-exposure stellar images at 2.2 microns and corrected at an image of the telescope pupil with piston motion from a segmented adaptive mirror. At a correction rate of 43 Hz, this level of adaptive control resulted in an integrated image with a clear diffraction-limited component of 0.075 arcsec FWHM. This stabilized component is present directly in the light arriving at the detector and is not the result of postprocessing. We discuss future improvements to our adaptive wave-front control and its application to astronomical observations.

Lloyd-Hart, M.↗

Study of the Radiative Properties of Inhomogeneous Stratocumulus Clouds

Clouds play an important role in the radiation budget of the atmosphere. A good understanding of how clouds interact with solar radiation is necessary when considering their effects in both general circulation models and climate models. This study examined the radiative properties of clouds in both an inhomogeneous cloud system, and a simplified cloud system through the use of a Monte Carlo model. The purpose was to become more familiar with the radiative properties of clouds, especially absorption, and to investigate the excess absorption of solar radiation from observations over that calculated from theory. The first cloud system indicated that the absorptance actually decreased as the cloud's inhomogeneity increased, and that cloud forcing does not indicate any changes. The simplified cloud system looked at two different cases of absorption of solar radiation in the cloud. The absorptances calculated from the Monte Carlo is compared to a correction method for calculating absorptances and found that the method can over or underestimate absorptances at cloud edges. Also the cloud edge effects due to solar radiation points to a possibility of overestimating the retrieved optical depth at the edge, and indicates a possible way to correct for it. The effective cloud fraction (Ne) for a long time has been calculated from a cloud's reflectance. From the reflectance it has been observed that the N, for most cloud geometries is greater than the actual cloud fraction (Nc) making a cloud appear wider than it is optically. Recent studies we have performed used a Monte Carlo model to calculate the N, of a cloud using not only the reflectance but also the absorptance. The derived Ne's from the absorptance in some of the Monte Carlo runs did not give the same results as derived from the reflectance. This study also examined the inhomogeneity of clouds to find a relationship between larger and smaller scales, or wavelengths, of the cloud. Both Fourier transforms and wavelet transforms were used to analyze the liquid water content of marine stratocumulus clouds taken during the ASTEX project. From the analysis it was found that the energy in the cloud is not uniformly distributed but is greater at the larger scales than at the smaller scales. This was determined by examining the slope of the power spectrum, and by comparing the variability at two scales from a wavelet analysis.

Batey, Michael↗

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗