Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Recovery and Calibration of Legacy Underground Nuclear Test Seismic Data from the Leo Brady Seismic Network

The Leo Brady Seismic Network (LBSN, originally the Sandia Seismic Network) was established in 1960 by Sandia National Laboratories to monitor underground nuclear tests (UGTs) at the Nevada National Security Site (NNSS, formerly named the Nevada Test Site). The LBSN has been in various configurations throughout its existence, but it has generally been comprised of four to six stations at regional distances (~150–400 km) from the NNSS with approximately evenly spaced azimuthal coverage. Between 1962 and the end of nuclear testing in 1992, the LBSN—and a sister network operated by Lawrence Livermore National Laboratories—was the most comprehensive United States source of regional seismic data of UGTs. Approximately 75% of all UGTs performed by the United States occurred in the predigital era. At that time, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to a central location and recorded as analog waveforms on high-fidelity magnetic audio tapes. These tapes have been in dry temperature-stable storage for decades and contain the sole record of this irreplaceable data; full waveforms of LBSN-recorded UGTs from this era were not routinely digitized or otherwise published. We have developed a process to recover and calibrate data from these tapes. First, we play back and digitize the tapes as audio. Next, we demodulate the FM “audio” into individual waveforms. We then estimate the various instrument constants through careful measurement of “weight-lift” tests performed prior to each UGT on each instrument. Finally, these coefficients allow us to scale and shape the derived instrument response of the seismographs and compute poles and zeros. Finally, the result of this process is a digital record of the recorded seismic ground motion in a modern data format, stored in a searchable database. To date, we have digitized tapes from 592 UGTs.

58 GEOSCIENCES↗

Local Optical Spectroscopies for Subnanometer Spatial Resolution Chemical Imaging

The evanescently coupled photon scanning tunneling microscopes (STMs) have special requirements in terms of stability and optical access. We have made substantial improvements to the stability, resolution, and noise floor of our custom-built visible-photon STM, and will translate these advances to our infrared instrument. Double vibration isolation of the STM base with a damping system achieved increased rigidity, giving high tunneling junction stability for long-duration and high-power illumination. Light frequency modulation with an optical chopper and phase-sensitive detection now enhance the signal-to-noise ratio of the tunneling junction during irradiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A novel injection-locked amplitude-modulated magnetron at 1497 MHz

Thomas Jefferson National Accelerator Facility (JLab) uses low efficiency klystrons in the CEBAF machine. In the older portion they operate at 30% efficiency with a tube mean time between failure (MTBF) of five to six years. A highly efficient source (>55-60%) must provide a high degree of backwards compatibility, both in size and voltage requirements, to replace the klystron presently used at JLab, while providing energy savings. Muons, Inc. is developing a highly reliable, highly efficient RF source based upon a novel injection-locked amplitude modulated (AM) magnetron with a lower total cost of ownership, >80% efficiency, and MTBF of six to seven years. The design of the RF source is based upon a single injection-locked magnetron system at 8 kW capable of operating up to 13 kW, using the magnetron magnetic field to achieve the AM required for backwards compatibility to compensate for microphonics and beam loads. A novel injection-locked 1497 MHz 8 kW AM magnetron with a trim magnetic coil was designed and its operation numerically simulated during the Phase I project. The low-level RF system to control the trim field and magnetron anode voltage was designed and modeled for operation at the modulation frequencies of the microphonics. A plan for constructing a prototype magnetron and control system was developed.

43 PARTICLE ACCELERATORS↗

Grain Boundary Diffusion Characterized by KPFM

Materials aging is a high-consequence failure mode in electronic systems. Such mechanisms can degrade the electrical properties of connectors, relays, wire bonds, and other interconnections. Lost performance will impact, not only that of the device, but also the function and reliability of next-level assemblies and the weapons system as a whole. The detections of changes to materials surfaces at the nanometer-scale resolution, provides a means to identify aging processes at their early stages before they manifest into latent failures that affect system-level performance and reliability. Diffusion will be studied on thin films that undergo accelerated aging using the nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM). The KPFM provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer spatial resolution of surface chemistry changes. The KPFM method can provide the means to measure surface, and near-surface, elemental concentrations that allow the determination of diffusion rate kinetics. These attributes will be illustrated by assessing diffusion in a thin film couple. Validation data will obtained from traditional techniques: (a) Auger electron spectroscopy (AES), x-ray fluorescence (XRF), and xray photoelectron spectroscopy (XPS).

36 MATERIALS SCIENCE↗

A novel injection-locked amplitude-modulated magnetron at 1497 MHz

Thomas Jefferson National Accelerator Facility (JLab) uses low efficiency klystrons in the CEBAF machine. In the older portion they operate at 30% efficiency with a tube mean time between failure (MTBF) of five to six years. A highly efficient source (>55-60%) must provide a high degree of backwards compatibility, both in size and voltage requirements, to replace the klystron presently used at JLab, while providing energy savings. Muons, Inc. is developing a highly reliable, highly efficient RF source based upon a novel injection-locked amplitude modulated (AM) magnetron with a lower total cost of ownership, >80% efficiency, and MTBF of six to seven years. The design of the RF source is based upon a single injection-locked magnetron system at 8 kW capable of operating up to 13 kW, using the magnetron magnetic field to achieve the AM required for backwards compatibility to compensate for microphonics and beam loads. A novel injection-locked 1497 MHz 8 kW AM magnetron with a trim magnetic coil was designed and its operation numerically simulated during the Phase I project. The low level RF system to control the trim field and magnetron anode voltage was designed and modeled for operation at the modulation frequencies of the microphonics. A plan for constructing a prototype magnetron and control system was developed.

42 ENGINEERING↗

Grain Boundary Diffusion Characterized by KPFM

Materials aging is a high-consequence failure mode in electronic systems. Such mechanisms can degrade the electrical properties of connectors, relays, wire bonds, and other interconnections. Lost performance will impact, not only that of the device, but also the function and reliability of next-level assemblies and the weapons system as a whole. The detections of changes to materials surfaces at the nanometer-scale resolution, provides a means to identify aging processes at their early stages before they manifest into latent failures that affect system-level performance and reliability. Diffusion will be studied on thin films that undergo accelerated aging using the nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM). The KPFM provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer spatial resolution of surface chemistry changes. The KPFM method can provide the means to measure surface, and near-surface, elemental concentrations that allow the determination of diffusion rate kinetics. These attributes will be illustrated by assessing diffusion in a thin film couple. Validation data will obtained from traditional techniques: (a) Auger electron spectroscopy (AES), x-ray fluorescence (XRF), and xray photoelectron spectroscopy (XPS).

36 MATERIALS SCIENCE↗

Digital Signal Processing of Radar Pulse Echoes

Modern high-performance radar systems are employing ever-more Digital Signal Processing (DSP), replacing ever-more formerly analog components. Precisely predicting the performance of digital filters and correlators requires an awareness of some of the finer points and characteristics of digital filters. We examine a representative radar receiver DSP chain that is processing a Linear Frequency Modulated (LFM) chirp.

47 OTHER INSTRUMENTATION↗

Grain Boundary Diffusion Characterized by KPFM

The nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM) will be used to assess a preliminary diffusion study on thin metal films that undergo accelerated aging. The KPFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer spatial resolution of surface chemistry changes and will be exercised in an effort to explore its capacity to map surface potential contrast caused by Cu diffusion in a manner that allows for a qualitative assessment of diffusion rate kinetics. Supporting data will be obtained from traditional techniques: AES, XPS and UPS. An aging study was conducted on thin metal test specimens comprised of Ti or Cr/Cu/Au layer thicknesses of 50nm/500nm/500nm up to 4μm respectively. The accelerated aging process, was performed in air at aging temperatures of 60°C, 100°C, and 125°C for aging times of 8 hours, 24 hours, 96 hours (4 days), and 216 hours (9 days). A calibration method was developed using Au, Al and Ni standards to establish precision and repeatability of the KPFM technique. Average CPDs and standard deviations for each metal were found and summarized.

36 MATERIALS SCIENCE↗

Recovery and calibration of legacy analog data from the Leo Brady Seismic Network for the Source Physics Experiment

The Leo Brady Seismic Network (LBSN) was established in 1960 by Sandia National Laboratories for monitoring underground nuclear tests (UGTs) at the Nevada Test Site— renamed in 2010 to the Nevada National Security Site (NNSS). The LBSN has been in various configurations throughout its existence, but it has been generally comprised of four to six stations at regional distances from the NNSS with evenly spaced azimuthal coverage. Between 1962 and the early 1980s, the LBSN—and a sister network operated by Lawrence Livermore National Laboratory—were the most comprehensive U.S. source of regional seismic data of UGTs. During the pre-digital era, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to the NTS and recorded in analog on hi-fi 8-track AMPEX tapes. These tapes have been stored in temperature-stable buildings or bunkers on the NNSS and Kirtland Air Force Base in Albuquerque, NM for decades and contain the sole record of this irreplaceable data from the analog era; full waveforms of UGTs during this time were never routinely converted to digital form. We have been developing a process over the past few years to recover and calibrate data from these tapes, converting them from FM audio to digital waveforms in ground motion units. The calibration of legacy data from the LBSN is still ongoing. To date, we have digitized tapes from 592 separate UGTs. As a proof-of-concept, we calibrated data from the BOXCAR event.

58 GEOSCIENCES↗

Cu/Al Through Au Diffusion Characterized by KPFM

The nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM) will be used to assess a diffusion study on thin metal films that undergo accelerated aging. The KPFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer-scale spatial resolution of surface chemistry changes. The KPFM technique will be exercised in an effort to explore its capacity to map surface potential contrast caused by diffusion in a manner that allows for a qualitative assessment of diffusion of Cu or Al through Au. Supporting data will be obtained from traditional techniques: AES, XPS and UPS. An aging study was conducted on thin metal test specimens comprised of 500nm Cu or Al then 500nm Au on Si. The accelerated aging process was performed under inert conditions at aging temperatures of 100°C for Cu/Au film stack and 175°C for Al/Au film stack at aging times of 8 hours, 24 hours, 96 hours (4 days), and 216 hours (9 days).A calibration method was developed using Au, Al and Cu standards to establish precision and repeatability of the KPFM technique. The average Contact Potential Difference (CPD)s and standard deviations for each metal were found and summarized. Averages from surface roughness of the AFM topography images and roughness analysis of KPFM potential images which yield an average CPD of each area of unaged vs aged coupon surfaces were compared and show trends that indicate surface chemistry.

36 MATERIALS SCIENCE↗

DATASET RELEASE AND QUALITY CONTROL REVIEW OF LIVERMORE NEVADA NETWORK (LNN) RECORDINGS OF A SUBSET OF NEVADA NUCLEAR SECURITY SITE NUCLEAR EXPLOSIONS FROM 1979 TO 1992.

Geophysical research on historical nuclear tests is an important aspect of future monitoring capabilities in seismic research. This research is challenging due to the limited number of digital seismic recordings during the peak of nuclear testing (1945-1992). These limited records are unique and non-reproducible data with potential high research impact. Releasing available nuclear explosion seismic records to the explosion monitoring community is thus of high value and is the motivation for this dataset release. The target of this effort was on compilation and quality control of regional seismic records of nuclear explosions recorded on Lawrence Livermore National Laboratory stations ELK, KNB, LAC, and MNV, known collectively as the Livermore National Network (LNN) (Figure 1). LNN was established in the early 1960s for the primary purpose of monitoring underground nuclear testing at the former Nevada Test Site (NTS), now known as the Nevada Nuclear Security Site (NNSS) following the signing of the Limited Test Ban Treaty (LTBT). LNN consisted initially of short-period vertical component Benioff’s recorded on film located at Mina, NV (MNV) and Kanab, Utah (KNB). LNN added two additional stations at Landers, CA (LAC) and Elko, NV (ELK) in 1967 and upgraded equipment to broadband seismometers recorded on frequency modulation (FM) tapes from 1967-1979, followed by digital recordings after 1979 (Jarpe, 1989). The digital recordings were on a variety of now obsolete media, including 9-track, Exabyte, and DAT tapes. Jarpe (1989) describes the seismic station instrumentation details over the period of deployment. LNN recorded valuable non-repeatable unique data of several hundreds of nuclear explosions at NNSS, as well as earthquakes and chemical and mining explosions (Walter, 2020). The details of these nuclear tests are provided in the Department of Energy Report NV-209 Rev 16 (DOE, 2015).

58 GEOSCIENCES↗

Transmission Line Based Sensor Design for FMCW Radar Processing of Collision Damage

This report presents a framework for transmission line ( T-L ) sensor design in Frequency Modulated Continuous Wave (FMCW) radar applications, with particular emphasis on modeling collision damage effects. Classical electromagnetic (EM) propagation theory is combined with impact mechanics to develop a model for analyzing transmission line behavior as a sensor under high-velocity impact conditions. The framework includes detailed mathematical derivations, spatial and temporal damage evolution models, and practical implementation considerations.

42 ENGINEERING↗

A MAGNETIC CORE VOLTAGE-TO-FREQUENCY CONVERTER

Controlling the frequency of a square-loop magnetic core oscillator using a dc voltage to give a voltage-to-frequency conversion for use in pulse frequency modulated telemetry systems

PFM TELEMETRY↗

PFM Simulator

Pulse frequency modulation simulator for design and testing of telemetry equipment for satellite systems

SATELLITE INSTRUMENTATION↗

Voltage variable oscillator has high phase stability

Two or more series RLC circuits are used with a negative feedback amplifier to make a voltage variable oscillator. This combination results in high phase stability and optimum frequency modulation.

Hearn, C. P.↗

Lunar communications.

Earth to Moon and lunar surface-to-surface communications using lunar satellites and FM and SSB modulation techniques

LUNAR COMMUNICATION↗