Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Ion Beam Therapy in Europe

At present, seven facilities in Europe treat deep-seated tumors with particle beams, six with proton beams and one with carbon ions. Three of these facilities are in Moscow, St. Petersburg and Dubna, Russia. Other facilities include the TSL Uppsala, Sweden, CPO Orsay, France, and PSI Villigen, Switzerland, all for proton therapy, and GSI, Darmstadt, Germany, which utilizes carbon ions only. But only two of these facilities irradiate with scanned ion beams: the Paul Scherer Institute (PSI), Villigen (protons) and the Gesellschaft fuer Schwerionenforschung (GSI), Darmstadt. These two facilities are experimental units within physics laboratories and have developed the technique of intensity-modulated beam scanning in order to produce irradiation conforming to a 3-D target. There are three proton centers presently under construction in Munich, Essen and Orsay, and the proton facility at PSI has added a superconducting accelerator connected to an isocentric gantry in order to become independent of the accelerator shared with the physics research program. The excellent clinical results using carbon ions at National Institute of Radiological Science (NIRS) in Chiba and GSI have triggered the construction of four new heavy-ion therapy projects (carbon ions and protons), located in Heidelberg, Pavia, Marburg and Kiel. The projects in Heidelberg and Pavia will begin patient treatment in 2009, and the Marburg and Kiel projects will begin in 2010 and 2011, respectively. These centers use different accelerator designs but have the same kind of treatment planning system and use the same approach for the calculation of the biological effectiveness of the carbon ions as developed at GSI [1]. There are many other planned projects in the works. Do not replace the word ''abstract,'' but do replace the rest of this text. If you must insert a hard line break, please use Shift+Enter rather than just tapping your ''Enter'' key. You may want to print this page and refer to it as a style sample before you begin working on your paper.

43 PARTICLE ACCELERATORS↗

Coupling of in-situ X-ray Microtomography Observations with Discrete Element Simulations-Application to Powder Sintering

The sintering of both a powder with a wide particle size distribution (0-63 {mu}m) and of a powder with artificially created pores is investigated by coupling in situ X-ray microtomography observations with Discrete Element simulations. The micro structure evolution of the copper particles is observed by microtomography all along a typical sintering cycle at 1050 deg. C at the European Synchrotron Research Facilities (ESRF, Grenoble, France). A quantitative analysis of the 3D images provides original data on interparticle indentation, coordination and particle displacements throughout sintering. In parallel, the sintering of similar powder systems has been simulated with a discrete element code which incorporates appropriate sintering contact laws from the literature. The initial numerical packing is generated directly from the 3D microtomography images or alternatively from a random set of particles with the same size distribution. The comparison between the information drawn from the simulations and the one obtained by tomography leads to the conclusion that the first method is not satisfactory because real particles are not perfectly spherical as the numerical ones. On the opposite the packings built with the second method show sintering behaviors close to the behaviors of real materials, although particle rearrangement is underestimated by DEM simulations.

36 MATERIALS SCIENCE↗

European MSc Programs in Nuclear Sciences - To meet the Need of Stakeholders

A stakeholder needs assessment, carried out under the EU-EURAC and EU-ENEN II projects, clearly showed that, at the European level, there are a significant and constant need for post-graduates with skills in radiochemistry, radioecology, radiation dosimetry and environmental modelling and a smaller, but still important, demand for radiobiologists and bio-modellers. Most of these needs are from government organizations. If only the nuclear industry is considered, then the largest demand is for radiochemists and radiation protection dosimetrists. Given this spectrum of need and existing capacity in the areas of radiobiology it was concluded that the needs identified would be most efficiently met by three new degree programs: European MSc Radiation Protection European MSc Analytical Radiochemistry European MSc Radioecology. All three master programs would be developed using the framework provided by the Bologna Convention and the lecturing could be shared among specialist Scientists within a network of collaborating universities. Therefore, educational plans have been developed for the above MSc degrees. These plans envisage each degree comprising three modules that are common to all the degrees (3x10 ECTS credits), three specialist modules (3x10 ECTS credits) and a research project (1x60 ECTS credits). The courses should be aimed, not only to fill the identified European postgraduate education gap in radiological sciences, but also to provide a modular structure that is easily accessed by stakeholders for CPD training. It is anticipated that the European Masters will meet the academic training requirements of qualified 'experts', as defined by the European Commission and the IAEA. At the Norwegian University of Life Sciences (UMB) a pilot MSc in Radioecology has successfully been initiated in collaboration with UK and France.

99 GENERAL AND MISCELLANEOUS↗

X-ray And EUV Spectroscopy Of Highly Charged Tungsten Ions

The Berlin EBIT has been established by the Max-Planck-Institut fuer Plasmaphysik to generate atomic physics data in support of research in the field of controlled nuclear fusion, by measuring the radiation from highly charged ions in the x-ray, extreme ultraviolet and visible spectral ranges and providing valuable diagnostics for high temperature plasmas. In future fusion devices, for example ITER, currently being constructed at Cadarache, France, the plasma facing components will be armored with high-Z materials, most likely tungsten, due to the favorable properties of this element. At the same time the tremendous radiation cooling of these high-Z materials represents a threat to fusion and obliges one to monitor carefully the radiation. With EBIT a selected ensemble of ions in specific charge states can be produced, stored and excited for spectroscopic investigations. Employing this technique, we have for example resolved the wide structure observed around 5 nm at the ASDEX Upgrade tokamak as originating from E1-transitions into the open 4d shell of tungsten ions in charge states 25+ to 37+ producing a band-like emission pattern. Further, these ions emit well-separated M1 lines in the EUV range around 65 nm suitable for plasma diagnostics. Kr-like to Cr-like tungsten ions (38+ to 50+) show strong soft-x-ray lines in the range 0.5 to 2 and 5 to 15 nm. Lines of even higher charged tungsten ions, up to Ne-like W{sup 64+}, abundant in the core plasma of present and future fusion test devices, have been investigated with high resolution Bragg-crystal spectroscopy at 0.13 nm. Recently, x-ray spectroscopic measurements of the dielectronic recombination LMn resonances of W{sup 60+} to W{sup 67+} ions have been preformed and compare well with atomic structure calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single crystal chemical vapor deposited diamond detectors for intensity-modulated radiation therapy applications

We report here on first intensity-modulated radiation therapy (IMRT) clinical tests performed at the Gustave Roussy Institute in France using one small (0.117 mm{sup 3}) synthetic single crystal diamond detector (SCDD). We report the comparison between the point doses evaluated with our detector, with a PTW semiflex air ionization chamber (0.125 cm{sup 3}) and calculated with the treatment planning system (TPS), respectively. The obtained results show a maximum difference of 2.3% for the diamond detector and of 4.6% for the ionization chamber, as compared with the TPS calculations. These very promising results show the potentiality of chemical vapor deposited SCDD for dosimetry of IMRT fields and opens up the field for diamond dosimeters toward novel applications such as very small beam monitoring.

36 MATERIALS SCIENCE↗

THE CRYOPLANT FOR THE ITER NEUTRAL BEAM TEST FACILITY TO BE BUILT AT RFX IN PADOVA, ITALY

The Neutral Beam Test Facility (NBTF), planned to be constructed in Padua (Italy), will constitute the prototype of the two Neutral Beam Injectors (NBI), which will be installed in the ITER plant (Cadarache-France). The NBTF is composed of a 1 MV accelerator that can produce a 40 A deuteron pulsed neutral beam particles. The necessary vacuum needed in the accelerator is achieved by two large cryopumps, designed by FZK-Karlsruhe, with radiation shields cooled between 65 K and 90 K and with cryopanels cooled by 4 bar supercritical helium (ScHe) between 4.5 K and 6.5 K. A new cryoplant facility will be installed with two large helium refrigerators: a Shield Refrigerator (SR), whose cooling capacity is up to 30 kW between 65 K and 90 K, and a helium Main Refrigerator (MR), whose equivalent cooling capacity is up to 800 W at 4.5 K. The cooling of the cryopanels is obtained with two (ScHe) 30 g/s pumps (one redundant), working in a closed cycle around 4 bar producing a pressure head of 100 mbar. Two heat exchangers are immersed in a buffer dewar connected to the MR. The MR and SR different operation modes are described in the paper, as well as the new cryoplant installation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

{sup 33,32}Arbeta-delayed particle and gamma emission

In the experiment performed at GANIL (France) we have studied the beta-delayed particle emission of the T{sub z} = -3/2 {sup 33}Ar and T{sub z} = -2 {sup 32}Ar proton emitters. Protons are emitted within the wide window (around 10 MeV) of excited states in {sup 33}Cl and {sup 32}Cl feeding the ground and the excited states of {sup 32}S and {sup 31}S. Proton-gamma coincidences have been used to determine the B(GT) strength in this region of excitation energy allowing us to reassign proton transitions to higher excited state with respect previous studies. The main motivation to revisit these nuclei is the increase of granularity and sensitivity of the charged particle detectors and the high sensitivity and large angular coverage obtained by the use of the CLOVER detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Tracking System of Exotic Nuclear Beams for FAIR

New accelerators like SPIRAL2 (GANIL, France) or FAIR (GSI, Germany) will be soon constructed, and they will be able to produce radioactive ion beams (RIB) with high intensities of current (>=10{sup 6} pps). These beams, at low energy, lower than 20 MeV/n, usually have high emittance, which imposes the use of tracking detectors before the target in order to reconstruct the trajectory of the ions. The group of Nuclear Physics at CNA (Centro Nacional de Aceleradores), is in charge of developing a tracking system for the low energy branch of FAIR (the HISPEC/DESPEC project). A collaboration with CEA-SACLAY was established, with the aim of developing, building and testing low pressure Secondary electron Detectors (SeD). Within this proposal we have projected and constructed a new Nuclear Physics Line in the CNA in order to be able to receive any kind of detector tests and the associated nuclear instruments.

43 PARTICLE ACCELERATORS↗

SPIRAL2 at GANIL: At the Dawn of a New Era

The exploration of unknown region of the nuclear mass chart, in particular, the neutron rich side, raised new and challenging physics issues in the understanding of nuclei far from stability. The physics of weakly bound systems, the appearance of shell quenching, the interface with astrophysical problems prompted the study of new generation of ''Rad ioactive Beam Facilities'' with high luminosity and the development of associated new experimental tools.GANIL presently offers unique opportunities in nuclear physics and many other fields. With the construction of SPIRAL2 over the next few years, GANIL is in a good position to retain its world-leading capability even though it faces strong competition from new and upgraded ISOL and fragmentation facilities. As selected by the ESFRI committee, the next generation of ISOL facility in Europe is represented by the SPIRAL2 project to be built at GANIL (Caen, France). SPIRAL2 is based on a high power, CW, superconducting LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more 10{sup 13} fissions/s. The expected radioactive beams intensities in the mass range from A = 60 to A = 140, will surpass by two order of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100* A to 1 mA), heavier ions (Ar up to Xe) at maximum energy of 14 MeV/n.In applied areas SPIRAL2 is considered as a powerful variable energy neutron source. The Neutrons For Science collaboration (NFS) is proposing a physics program on fission induced by fast neutrons as well as fusion studies on materials.Under the 7FP program of European Union called 'Preparatory phase', the SPIRAL2 project has been granted a budget of about 4 MEuro to build up an international consortium around this new venture. Regarding the future physics program a call for Letter of intents has been launched in Oct 2006 and 8 large International collaborations has been built up around new instruments for SPIRAL2. The status of the construction of SPIRAL2 accelerator and technical R and D programs for physics instrumentation (detectors, spectrometers) in collaboration with EU and International partners will be presented.

43 PARTICLE ACCELERATORS↗

GANIL-SPIRAL1-SPIRAL2: Highlights and Perspectives

GANIL presently offers unique opportunities in nuclear physics and many other fields that arise from not only the provision of low-energy stable beams, fragmentation beams and re-accelerated radioactive species, but also from the availability of a wide range of state-of-the-art spectrometers and instrumentation. A few examples of recent highlights are presented.With the construction of SPIRAL2 over the next few years, GANIL is in a good position to retain its world-leading capability. As selected by the ESFRI committee, the next generation of ISOL facility in Europe is represented by the SPIRAL2 project to be built at GANIL (Caen, France). SPIRAL 2 is based on a high power, CW, superconducting LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more 10{sup 13} fissions/s. The expected radioactive beams intensities in the mass range from A = 60 to A = 140, will surpass by two order of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100*A to 1 mA), heavier ions (Ar up to Xe) at maximum energy of 14 MeV/n.Under the 7FP program of European Union called*Preparatory phase*, the SPIRAL2 project has been granted a budget of about 4 MEuro to build up an international consortium around this new venture. The status of the construction of SPIRAL2 accelerator and associated physics instruments in collaboration with EU and International partners will be presented.

43 PARTICLE ACCELERATORS↗

TEMPO: a New Insertion Device Beamline at SOLEIL for Time Resolved Photoelectron Spectroscopy Experiments on Solids and Interfaces

A new insertion device beamline is now operational on straight section 8 at the SOLEIL synchrotron radiation source in France. The beamline and the experimental station were developed to optimize the study of the dynamics of electronic and magnetic properties of materials. Here we present the main technical characteristics of the installation and the general principles behind them. The source is composed of two APPLE II type insertion devices. The monochromator with plane gratings and spherical mirrors is working in the energy range 40-1500 eV. It is equipped with VLS, VGD gratings to allow the user optimization of flux or higher harmonics rejection. The observed resonance structures measured in gas phase enable us to determine the available energy resolution: a resolving power higher than 10000 is obtained at the Ar 2p, N 1s and Ne K-edges when using all the optical elements at full aperture. The total flux as a function of the measured photon energy and the characterization of the focal spot size complete the beamline characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instrumentation and Experimental Developments for the Beamlines at the Synchrotron SOLEIL

This paper presents an overview of the instrumentation and experiments developed for the beamlines at Synchrotron SOLEIL in France. Currently fourteen beamlines are opened to users out of the twenty six scheduled. About half of the beamlines cover the soft x-rays region using spectroscopy and imagery techniques. The second half covers the hard x-rays field studying diffraction of matter. Some sample environments carried out for beamlines, for biology, chemistry and surface sciences are described. For the soft x-rays beamlines, carbon contamination of optics is a crucial issue. Different experiments are currently under study in order to reduce or even avoid this effect. Other studies relate to the improvement of metrological methods for beamline optics, to the reduction of vibrational effects for the microbeams and development of computer control for diffractometers. The various types of instruments and experiments will be presented both with an overview of the status of the beamlines in operation and under construction.

43 PARTICLE ACCELERATORS↗

Thermal Expansion of NANOPERM-type Alloys from In-situ X-ray Diffraction

NANOPERM-type alloys with nominal compositions of (Fe{sub 1-x}Co{sub x}){sub 76}Mo{sub 8}Cu{sub 1}B{sub 15}(x = 0 and 0.5) were prepared by a single-roller melt-spinning technique. Temperature evolution of the as-quenched ribbons during constant-rate heating (10 degree sign C/min) was continuously followed using a high-energy (88 keV) X-ray diffraction (XRD), performed on the ID11 undulator beamline at the ESRF (Grenoble, France). Moessbauer spectroscopy and XRD confirm an amorphous nature of the melt-spun ribbons. Furthermore, Moessbauer spectroscopy reveals a significant change of magnetic state of the as-quenched precursors when substituting Fe by Co (x 0.5). Analyzing a series of XRD patterns in a reciprocal space yields a thermal expansion of the amorphous alloys providing an insight about the thermally activated effects such as relaxation and crystallization.

36 MATERIALS SCIENCE↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray crystal spectrometer for opacity measurements in the 8-18 A spectral range at the LULI laser facility

An x-ray crystal spectrometer was built in order to measure opacities in the 8-18 A spectral range with an average spectral resolution of <{lambda}/{delta}{lambda}>{approx}400. It has been successfully used at the LULI-2000 laser facility (See C. Sauteret, rapport LULI 2001, 88 (2002) at Ecole Polytechnique (France) to measure in the same experimental conditions the 2p-3d transitions of several elements with the neighboring atomic number Z: Fe, Ni, Cu, and Ge [G. Loisel et al., High Energy Density Phys. 5, 173 (2009)]. Hence, a spectrometer with a wide spectral range is needed. This spectrometer features two lines of sight. In this example, one line of sight looks through the sample and the other one is looking directly at the backlighter emission. Both are outfitted with a spherical condensing mirror. A TlAP crystal is used for spectral dispersion. Detection is made with an image plate Fuji BAS TR2025, which is sensitive to x rays. We present some experimental results showing the performances of this spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active spectroscopic measurements using the ITER diagnostic system

Active (beam-based) spectroscopic measurements are intended to provide a number of crucial parameters for the ITER device being built in Cadarache, France. These measurements include the determination of impurity ion temperatures, absolute densities, and velocity profiles, as well as the determination of the plasma current density profile. Because ITER will be the first experiment to study long timescale ({approx}1 h) fusion burn plasmas, of particular interest is the ability to study the profile of the thermalized helium ash resulting from the slowing down and confinement of the fusion alphas. These measurements will utilize both the 1 MeV heating neutral beams and a dedicated 100 keV hydrogen diagnostic neutral beam. A number of separate instruments are being designed and built by several of the ITER partners to meet the different spectroscopic measurement needs and to provide the maximum physics information. In this paper, we describe the planned measurements, the intended diagnostic ensemble, and we will discuss specific physics and engineering challenges for these measurements in ITER.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astrophysically Important Reaction Rates For Novae And X-ray Bursts From Proton Breakup At Intermediate Energies

We discuss the use of one-nucleon removal reactions of loosely bound nuclei at intermediate energies as an indirect method in nuclear astrophysics. The breakup reactions are proved to be good spectroscopic tools and can be used to study a large number of loosely bound proton- or neutron-rich nuclei over a wide range of beam energies. As peripheral processes, they can be used to extract asymptotic normalization coefficients (ANCs) from which non-resonant capture reaction rates of astrophysical interest can be calculated parameter free. In this talk, we present results of a proton-breakup experiment carried out at GANIL (France) with a cocktail beam centered around {sup 23}Al at 50 MeV/nucleon. Momentum distributions of the breakup fragments, inclusive and in coincidence with gamma rays detected by EXOGAM Germanium clover array, were measured in the focal plan of SPEG energy-loss spectrometer. We present in particular the investigations of reaction rates for {sup 22}Mg(p,{gamma}){sup 23}Al and {sup 23}Al(p,{gamma}){sup 24}Si important for novae and X-ray bursts, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GANIL-SPIRAL2: A new era

GANIL presently offers unique opportunities in nuclear physics and many other fields that arise from not only the provision of low-energy stable beams, fragmentation beams and re-accelerated radioactive species, but also from the availability of a wide range of state-of-the-art spectrometers and instrumentation. A few examples of recent highlights are discussed in the present paper.With the construction of SPIRAL2 over the next few years, GANIL is in a good position to retain its world-leading capability. As selected by the ESFRI committee, the next generation of ISOL facility in Europe is represented by the SPIRAL2 project to be built at GANIL (Caen, France). SPIRAL 2 is based on a high power, CW, superconducting LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more than 10{sup 13} fissions/s. The expected radioactive beam intensities in the mass range from A = 60 to A = 140, will surpass by two orders of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100 {mu}A to 1 mA), heavier ions (Ar up to Xe) at maximum energy of 14 MeV/n. Under the 7FP program of European Union called *Preparatory phase*, the SPIRAL2 project has been granted a budget of about 4MEuro to build up an international consortium around this new venture. The status of the construction of SPIRAL2 accelerator and associated physics instruments in collaboration with EU and International partners will be presented.

43 PARTICLE ACCELERATORS↗