Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9). Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

InGaSb Defect Filter Layer to Improve Performance of GaSb Solar Cells Grown on GaAs Substrates

The reduction of the threading dislocation density in metamorphic GaSb grown on GaAs substrates through the use of InGaSb defect filter layers has been investigated. More specifically, we study the effects of strain and thickness on the ability of a InGaSb defect filter layer to reduce threading dislocations in GaSb solar cells grown on GaAs substrates. The strain between the GaSb metamorphic layer on GaAs substrate (99.5% relaxed) and the InGaSb defect filter layer is varied by changing the indium composition in the InGaSb layer. Here, it is demonstrated that an InGaSb defect filter layer with 0.6% strain is more effective for blocking threading dislocations compared with higher-strain layers, resulting in improved short-circuit current (J sc ) and open-circuit voltage (V oc ) for the metamorphic GaSb solar cell. The optimization of the defect filter layer involves varying the thickness of the layer to achieve the lowest possible threading dislocation density. This also takes into account the critical thickness of the InGaSb layer on GaSb to avoid generation of threading dislocations from the InGaSb layer itself. It is shown that adding an In 0.11 Ga 0.89 Sb defect filter layer with thickness of 250 nm and 0.6% strain beneath a GaSb solar cell grown on a GaAs substrate improves V oc from 0.1 V to 0.16 V and J sc from 19.7 mA/cm 2 to 24.7 mA/cm 2 .

36 MATERIALS SCIENCE↗

High-performance implementation of Chebyshev filter diagonalization for interior eigenvalue computations

We study Chebyshev filter diagonalization as a tool for the computation of many interior eigenvalues of very large sparse symmetric matrices. In this technique the subspace projection onto the target space of wanted eigenvectors is approximated with filter polynomials obtained from Chebyshev expansions of window functions. After the discussion of the conceptual foundations of Chebyshev filter diagonalization we analyze the impact of the choice of the damping kernel, search space size, and filter polynomial degree on the computational accuracy and effort, before we describe the necessary steps towards a parallel high-performance implementation. Because Chebyshev filter diagonalization avoids the need for matrix inversion it can deal with matrices and problem sizes that are presently not accessible with rational function methods based on direct or iterative linear solvers. To demonstrate the potential of Chebyshev filter diagonalization for large-scale problems of this kind we include as an example the computation of the 10{sup 2} innermost eigenpairs of a topological insulator matrix with dimension 10{sup 9} derived from quantum physics applications.

97 MATHEMATICS AND COMPUTING↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of high damage threshold laser-machined apodizers and gain filters for laser applications

We have developed high damage threshold filters to modify the spatial profile of a high energy laser beam. The filters are formed by laser ablation of a transmissive window. The ablation sites constitute scattering centers which can be filtered in a subsequent spatial filter. Finally, by creating the filters in dielectric materials, we see an increased laser-induced damage threshold from previous filters created using ‘metal on glass’ lithography.

47 OTHER INSTRUMENTATION↗

A Kalman filter for feedback control of rotating external kink instabilities in the presence of noise

The simulation and experimental optimization of a Kalman filter feedback control algorithm for n=1 tokamak external kink modes are reported. In order to achieve the highest plasma pressure limits in ITER, resistive wall mode stabilization is required [T. C. Hender et al., Nucl. Fusion 47, S128 (2007)] and feedback algorithms will need to distinguish the mode from noise due to other magnetohydrodynamic activity. The Kalman filter contains an internal model that captures the dynamics of a rotating, growing n=1 mode. This model is actively compared with real-time measurements to produce an optimal estimate for the mode's amplitude and phase. On the High Beta Tokamak-Extended Pulse experiment [T. H. Ivers et al., Phys. Plasmas 3, 1926 (1996)], the Kalman filter algorithm is implemented using a set of digital, field-programmable gate array controllers with 10 {mu}s latencies. Signals from an array of 20 poloidal sensor coils are used to measure the n=1 mode, and the feedback control is applied using 40 poloidally and toroidally localized control coils. The feedback system with the Kalman filter is able to suppress the external kink mode over a broad range of phase angles between the sensed mode and applied control field. Scans of filter parameters show good agreement between simulation and experiment, and feedback suppression and excitation of the kink mode are enhanced in experiments when a filter made using optimal parameters from the scans is used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of active porous medium filters based on plasma textiles

Inexpensive, flexible, washable, and durable materials that serve as antimicrobial filters and self-decontaminating fabrics are needed to provide active protection to people in areas regularly exposed to various biohazards, such as hospitals and bio research labs working with pathogens. Airlines and cruise lines need such material to combat the spread of infections. In households these materials can be used in HVAC filters to fight indoor pollution, which is especially dangerous to people suffering from asthma. Efficient filtering materials are also required in areas contaminated by other types of hazardous dust particulates, such as nuclear dust. The primary idea that guided the undertaken study is that a microplasma-generating structure can be embedded in a textile fabric to generate a plasma sheath (''plasma shield'') that kills bacterial agents coming in contact with the fabric. The research resulted in the development of a plasma textile that can be used for producing new types of self-decontaminating garments, fabrics, and filter materials, capable of activating a plasma sheath that would filter, capture, and destroy any bacteriological agent deposited on its surface. This new material relies on the unique antimicrobial and catalytic properties of cold (room temperature) plasma that is benign to people and does not cause thermal damage to many polymer textiles, such as Nomex and polypropylene. The uniqueness of cold plasma as a disinfecting agent lies in the inability of bacteria to develop resistance to plasma exposure, as they can for antibiotics. Plasma textiles could thus be utilized for microbial destruction in active antimicrobial filters (for continuous decontamination and disinfection of large amounts of air) as well as in self-decontaminating surfaces and antibacterial barriers (for example, for creating local antiseptic or sterile environments around wounds and burns).

36 MATERIALS SCIENCE↗

Model of the boundary layer of a vacuum-arc magnetic filter

A model is developed to describe the electrostatic boundary layer in a positively biased magnetic filter in filtered arcs with low collisionality. The set of equations used includes the electron momentum equation, with an anomalous collision term due to micro-instabilities leading to Bohm diffusion, electron mass conservation, and Poisson equation. Analytical solutions are obtained, valid for the regimes of interest, leading to an explicit expression to determine the electron density current to the filter wall as a function of the potential of the filter and the ratio of electron density at the plasma to that at the filter wall. Using a set of planar and cylindrical probes it is verified experimentally that the mentioned ratio of electron densities remains reasonably constant for different magnetic field values and probe bias, which allows to obtain a closed expression for the current. Comparisons are made with the experimentally determined current collected at different sections of a positively biased straight filter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photonic crystal ring resonator based optical filters for photonic integrated circuits

In this paper, a two Dimensional (2D) Photonic Crystal Ring Resonator (PCRR) based optical Filters namely Add Drop Filter, Bandpass Filter, and Bandstop Filter are designed for Photonic Integrated Circuits (PICs). The normalized output response of the filters is obtained using 2D Finite Difference Time Domain (FDTD) method and the band diagram of periodic and non-periodic structure is attained by Plane Wave Expansion (PWE) method. The size of the device is minimized from a scale of few tens of millimeters to the order of micrometers. The overall size of the filters is around 11.4 μm × 11.4 μm which is highly suitable of photonic integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple attenuation to reflection seismic data using Radon filter and Wave Equation Multiple Rejection (WEMR) method

Separation between signal and noise, incoherent or coherent, is important in seismic data processing. Although we have processed the seismic data, the coherent noise is still mixing with the primary signal. Multiple reflections are a kind of coherent noise. In this research, we processed seismic data to attenuate multiple reflections in the both synthetic and real seismic data of Mentawai. There are several methods to attenuate multiple reflection, one of them is Radon filter method that discriminates between primary reflection and multiple reflection in the τ-p domain based on move out difference between primary reflection and multiple reflection. However, in case where the move out difference is too small, the Radon filter method is not enough to attenuate the multiple reflections. The Radon filter also produces the artifacts on the gathers data. Except the Radon filter method, we also use the Wave Equation Multiple Elimination (WEMR) method to attenuate the long period multiple reflection. The WEMR method can attenuate the long period multiple reflection based on wave equation inversion. Refer to the inversion of wave equation and the magnitude of the seismic wave amplitude that observed on the free surface, we get the water bottom reflectivity which is used to eliminate the multiple reflections. The WEMR method does not depend on the move out difference to attenuate the long period multiple reflection. Therefore, the WEMR method can be applied to the seismic data which has small move out difference as the Mentawai seismic data. The small move out difference on the Mentawai seismic data is caused by the restrictiveness of far offset, which is only 705 meter. We compared the real free multiple stacking data after processing with Radon filter and WEMR process. The conclusion is the WEMR method can more attenuate the long period multiple reflection than the Radon filter method on the real (Mentawai) seismic data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatiotemporal filtering of MR-temperature artifacts arising from bowel motion during transurethral MR-HIFU

Purpose: Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in the prostate and to monitor for potential damage to surrounding tissues. This requires that the MR thermometry measurements are an accurate representation of the true tissue temperature. The proton resonance frequency shift thermometry method used is sensitive to tissue motion and changes in the local magnetic susceptibility that can be caused by the motion of air bubbles in the rectum, which can impact the performance of transurethral MR-HIFU in these regions of the gland. Methods: A method is proposed for filtering of temperature artifacts based on the temporal variance of the temperature, using empirical and dynamic positional knowledge of the ultrasonic heating beam, and an estimation of the measurement noise. A two-step correction strategy is introduced which eliminates artifact-detected temperature variations while keeping the noise level low through spatial averaging. Results: The filter has been evaluated by postprocessing data from five human transurethral ultrasound treatments. The two-step correction process led to reduced final temperature standard deviation in the prostate and rectum areas where the artifact was located, without negatively affecting areas distal to the artifact. The performance of the filter was also found to be consistent across all six of the data sets evaluated. The evaluation of the detection criterion parameter M determined that a value of M = 3 achieves a conservative filter with minimal loss of spatial resolution during the process. Conclusions: The filter was able to remove most artifacts due to the presence of moving air bubbles in the rectum during transurethral MR-HIFU. A quantitative estimation of the filter capabilities shows a systematic improvement in the standard deviation of the corrected temperature maps in the rectum zone as well as in the entire acquired slice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-207B-10: Effect of CT Reconstruction Filter On Measured Hounsfield Values in Lung Nodules

Purpose: Measured Hounsfield numbers in CT are used by radiologists to determine the presence of calcium or fat in lung nodules, either of which suggests a benign diagnosis. However, substantial variations in Hounsfield number may arise due to the use of different reconstruction parameters such as the filter/kernel, leading to measurement inaccuracies. This quality improvement project was developed to demonstrate measurement pitfalls and to identify acceptable conditions for incorporating Hounsfield values as a factor in lung nodule diagnosis. Methods: 12 mm-diameter spheres of polyurethane and urethane foam were placed into an anthropomorphic chest phantom, and 10 mm-diameter tubes with varying iodine concentrations were placed into a 16 cm PMMA cylindrical phantom. Additionally, 11 mm-diameter PMMA and HDPE spheres were placed in a 10 cm PMMA cylindrical phantom. Phantoms were scanned at 120 kVp using a Siemens Biograph mCT and on a Philips iCT and reconstructed using various reconstruction filters. Results: For the Siemens system, both sharp kernels and smooth kernels altered the Hounsfield numbers. Hounsfield numbers varied within a range of 8.9 HU for urethane foam and varied within 58.7 HU for polyurethane. The iodine measurements varied up to 37.9 HU for the lowest concentration. For the Philips system, Hounsfield numbers were relatively consistent but were higher for the “Detail” and “Lung Enhanced” filters, varying by 36.9 HU for PMMA and 15.9 HU for HDPE. Conclusion: Reconstruction filters can change the measured Hounsfield numbers of nodular objects, especially with detail-enhancing (sharpening) filters commonly used in lung imaging. Measured values should only be used for diagnostic decision support with filters that have demonstrated accuracy and consistency. While filter accuracy statements are available from manufacturers, radiologists are likely not aware of the extent of potential variations that can occur in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Response functions for Logarithnically Spaced Interference Filters Manufactured for Dark Energy Missions

This data package pertains to test filters produced for the SNAP project. Filter #7 was produced in accordance with the SNAP Test Filter Spec r6.t, including several exceptions taken by JDSU and documented in the JDSU sales order. A set of three Filter #7 parts have been produced for the project, as well as two witnesses for cold environment testing. SNAP Test Filter Spec r6.t requests data to accompany the filters; that is the purpose of this document.

47 OTHER INSTRUMENTATION↗

Evaluating the use of PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of nuclear canister filters

This document details the distinction between using PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of filters. This document is developed to justify the use of PAO rather than DOP for evaluating the performance of filters in the SAVY 4000 and Hagan containers. The design criteria (Anderson et al, 2012) for purchasing SAVY 4000 containers and the Safety Analysis Report for the SAVY 4000 Container Series specified that the filter must “capture greater than 99.97% of 0.45 μm mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentration of 65±15 micrograms per liter.”This corresponds to a leakage percent of 0.03% (3.0x10 -2 ). The density of DOP oil is 985 kg/m 3 and the density of PAO oil is 819 kg/m 3 . ATI Test Inc measured the mass mean diameter of aerosol distributions produced by a single Laskin type III-A nozzle operating at a 20 psig air pressure as 0.563 μm for DOP oil and 0.549 μm for PAO oil. (See Appendix A.) For both types of oil in this document, the single fiber method calculated the leakage percent to be 4.4x10 -5 for DOP oil and 4.7x10 -5 for PAO oil. Although the percent error between these two quantities is 7.7%, these calculated leakage percent values are more than two orders of magnitude less than the criterion specified in the SAVY canister SAR. As a point of reference, the photometer used to measure the SAVY canister filter performance cannot resolve values for the leakage percent below 1.0x10 -5 . Additionally, over a range of particle sizes from 0.01 μm to 3.0 μm, there was less than 4.0x10 -5 error between the calculated filter efficiency for the two types of oil at any particular particle size diameter. In conclusion, the difference between using DOP and PAO for testing SAVY canister filters is of inconsequential concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of an MCU HEPA filter

A series of direct analyses on three portions (inlet, center, and outlet) of the High Efficiency Particulate Air (HEPA) filter material from the Modular Caustic-Side Solvent Extraction Unit (MCU) have been performed; this includes x-ray methods such as X-Ray Diffraction (XRD), Contained Scanning Electron Microscopy (CSEM) and X-Ray Fluorescence (XRF), as well as Fourier Transform InfraRed spectroscopy (FTIR). Additionally, two leaching studies (one with water, one with dichloromethane) have been performed on three portions (inlet, center, and outlet) of the HEPA filter material, with the leachates being analyzed by Inductively-coupled plasma emission spectroscopy (ICPES), Semi-Volatile Organic Analysis (SVOA) and gammascan. From the results of the analyses, SRNL feels that cesium-depleted solvent is being introduced into the HEPA filter. The most likely avenue for this is mechanical aerosolization of solvent, where the aerosol is then carried along an airstream into the HEPA filter. Once introduced into the HEPA filter media, the solvent wicks throughout the material, and migrates towards the outlet end. Once on the outlet end, continual drying could cause particulate flakes to exit the filter and travel farther down the airstream path.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

FY2022 Filter Test for TRU Waste Drum Prototype Unit

Continuing last year’s (fiscal year 2021) work, a prototype instrument and an NPI-6 Integrated Work Document (IWD) were developed to assess the functionality of filters on transuranic waste containers (commonly called 55 Gallon ring-top drums) without requiring the removal of the drum lid. The purpose of this work is to determine the air flow and pressure characteristics associated with filter clogging, filter pressure drop at a fixed flow rate, and leakage around the lid seal. The FY22 objectives included: (A) Development of prototype device, (B) Drafting an IWD document, (C) Defining a filter clogging parameter, (D) Assessing filter damage due to over-pressure events, and (E) A path forward to obtain approval of the system safety filters in compliance with P101-16 Industrial Ventilation – non HVACR (LANL 2022).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photometric Redshifts of Emission-line Galaxies Using Ramp Filters

Broadband photometric redshifts are routinely obtained for galaxies to estimate their distances. While effective for many uses, the common resolution in z of 0.01–0.02 is too coarse for detailed large-scale structure mapping, particularly in low-density volumes where the galaxy distribution is least understood. To map galaxies in these low-density volumes, and noting that the percentage of galaxies having emission tends to rise as number density decreases, we have designed a filter system to photometrically measure the redshifts of galaxies with emission. The system consists of two “ramp” filters that cover a common wavelength range with transmission curves sloping from blue to red and from red to blue respectively. This causes the intensity of the image through either filter to be a function of the wavelength of the emission line. A third filter with a bandpass to the side is used to measure and remove the continuum. We have obtained a set of such filters that are tuned for isolating Hα in the redshift range of 3,000–9,000 km s{sup −1}. Simulated photometry, applied to spectra of 197 emission-line galaxies from the SDSS, shows the accuracy of the method to be between 250 and 620 km s{sup −1}, depending on line strength. Actual photometry of a sample of 16 active galaxies measured their redshifts with an accuracy of 573 km s{sup −1}. This is approximately an order of magnitude more accurate than broadband photometric redshifts. We discuss the errors inherent in this method and present ways to modify the filter set to further improve accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗