At least 505 records · Page 28

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Assessment of the Impact of Gamma-ray Detector Material Properties on Spectroscopic Performance

Abstract Pacific Northwest National Laboratory (PNNL) is performing a computational assessment of the impact of several important gamma-ray detector material properties (e.g. energy resolution and intrinsic detection efficiency) on the scenario-specific spectroscopic performance of these materials. The research approach combines 3D radiation transport calculations, detector response modeling, and spectroscopic analysis of simulated energy deposition spectra to map the functional dependence of detection performance on the underlying material properties. This assessment is intended to help guide formulation of performance goals for new detector materials within the context of materials discovery programs, with an emphasis on applications in the threat reduction, nonproliferation, and safeguards/ verification user communities. The research results will also provide guidance to the gamma-ray sensor design community in estimating relative spectroscopic performance merits of candidate materials for novel or notional detectors.

Jordan, David V.↗

Evaluating the Community Land Model (CLM4.5) at a coniferous forest site in northwestern United States using flux and carbon-isotope measurements

Droughts in the western United States are expected to intensify with climate change. Thus, an adequate representation of ecosystem response to water stress in land models is critical for predicting carbon dynamics. The goal of this study was to evaluate the performance of the Community Land Model (CLM) version 4.5 against observations at an old-growth coniferous forest site in the Pacific Northwest region of the United States (Wind River AmeriFlux site), characterized by a Mediterranean climate that subjects trees to water stress each summer. CLM was driven by site-observed meteorology and calibrated primarily using parameter values observed at the site or at similar stands in the region. Key model adjustments included parameters controlling specific leaf area and stomatal conductance. Default values of these parameters led to significant underestimation of gross primary production, overestimation of evapotranspiration, and consequently overestimation of photosynthetic 13 C discrimination, reflected in reduced 13 C: 12 C ratios of carbon fluxes and pools. Adjustments in soil hydraulic parameters within CLM were also critical, preventing significant underestimation of soil water content and unrealistic soil moisture stress during summer. After calibration, CLM was able to simulate energy and carbon fluxes, leaf area index, biomass stocks, and carbon isotope ratios of carbon fluxes and pools in reasonable agreement with site observations. Overall, the calibrated CLM was able to simulate the observed response of canopy conductance to atmospheric vapor pressure deficit (VPD) and soil water content, reasonably capturing the impact of water stress on ecosystem functioning. Both simulations and observations indicate that stomatal response from water stress at Wind River was primarily driven by VPD and not soil moisture. The calibration of the Ball–Berry stomatal conductance slope ( m bb ) at Wind River aligned with findings from recent CLM experiments at sites characterized by the same plant functional type (needleleaf evergreen temperate forest), despite significant differences in stand composition and age and climatology, suggesting that CLM could benefit from a revised m bb value of 6, rather than the default value of 9, for this plant functional type. Conversely, Wind River required a unique calibration of the hydrology submodel to simulate soil moisture, suggesting that the default hydrology has a more limited applicability. Here, this study demonstrates that carbon isotope data can be used to constrain stomatal conductance and intrinsic water use efficiency in CLM, as an alternative to eddy covariance flux measurements. It also demonstrates that carbon isotopes can expose structural weaknesses in the model and provide a key constraint that may guide future model development.

54 ENVIRONMENTAL SCIENCES↗

Occupancy schedules learning process through a data mining framework

Building occupancy is a paramount factor in building energy simulations. Specifically, lighting, plug loads, HVAC equipment utilization, fresh air requirements and internal heat gain or loss greatly depends on the level of occupancy within a building. Developing the appropriate methodologies to describe and reproduce the intricate network responsible for human-building interactions are needed. Extrapolation of patterns from big data streams is a powerful analysis technique which will allow for a better understanding of energy usage in buildings. A three-step data mining framework is applied to discover occupancy patterns in office spaces. First, a data set of 16 offices with 10 minute interval occupancy data, over a two year period is mined through a decision tree model which predicts the occupancy presence. Then a rule induction algorithm is used to learn a pruned set of rules on the results from the decision tree model. Finally, a cluster analysis is employed in order to obtain consistent patterns of occupancy schedules. Furthermore, the identified occupancy rules and schedules are representative as four archetypal working profiles that can be used as input to current building energy modeling programs, such as EnergyPlus or IDA-ICE, to investigate impact of occupant presence on design, operation and energy use in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coal-derived conductive pavement for winter de-icing: prototype, modeling, and simulation

Existing pavement de-icing methods result in high installation and maintenance costs, traffic delays, excessive weariness and corrosion, and negative environmental and safety impacts. To overcome these challenges, this paper presents an innovative pathway to designing and constructing smart self-heating pavements using a low-cost coal-char bearing asphalt material. The conductive asphalt incorporates coal char, i.e., a key byproduct of the coal pyrolysis process, into the Stone Mastic Asphalt (SMA) mixture. This asphalt containing coal-derived solid carbon exhibits highly tailorable electrical conductivity, satisfactory mechanical and thermophysical properties, and superior cost-efficiency as compared to other conductive pavement materials. The de-icing performance was also demonstrated by laboratory experiments on a bench-scale prototype. Furthermore, an efficient thermal network model was developed and validated by experiments to investigate the transient thermal behavior and energy performance of the Ohmic heating pavement system. Furthermore, the whole-year energy simulation case studies were conducted on a bridge pavement with an annual energy use of 24.6–1444.8 kWh/m 2 , showcasing its potential in field applications across cool humid, cold humid, and subarctic/arctic climate zones.

42 ENGINEERING↗

NIST Infiltration Tools for Commercial Buildings

The Department of Energy estimates that infiltration through building envelopes accounted for 6 % of the total energy consumed by commercial buildings and 21 % of the heating and cooling energy. Air barrier requirements are now being included in ASHRAE Standards 90.1 and 189.1 and other construction requirements. The energy impacts of unintended infiltration on building energy use can be significant, but current energy simulation software and design methods are generally not able to accurately account for envelope infiltration and the impacts of improved airtightness. NIST has been developing tools to better account for infiltration in building energy models. The tools that will be discussed in this paper include: CONTAM Results Export Tool; weather-correlated infiltration inputs for prototype commercial buildings and the associated Open Studio Measures; and a web-based tool to evaluate the energy savings of building envelope airtightening, which was developed with the Oak Ridge National Laboratory and the Air Barrier Association of America. This paper briefly describes each tool, their applications, and the benefits of using each. All of the tools are publicly available at no cost.

Ng, Lisa↗

Sandia's Current Energy Conversion module for Flexible-Mesh Delft3D flow solver v. 1.0

The DOE has funded Sandia National Labs (SNL) to develop an open-source modeling tool to guide the design and layout of marine hydrokinetic (MHK) arrays to maximize power production while minimizing environmental effects. This modeling framework simulates flows through and around a MHK arrays while quantifying environmental responses. As an augmented version of the Dutch company, Deltares’s, environmental hydrodynamics code, Delft3D, SNL-Delft3D-CEC-FM includes a new module that simulates energy conversion (momentum withdrawal) by MHK current energy conversion devices with commensurate changes in the turbulent kinetic energy and its dissipation rate. SNL-Delft3D-CEC-FM modified the Delft3D flexible mesh flow solver, DFlowFM. The Following is a description of Deltares’s open-source code Delft3D from which Delft3D-CEC is built upon. “Delft3D is a world leading 3D modeling suite to investigate hydrodynamics, sediment transport and morphology and water quality for fluvial, estuarine and coastal environments. As per 1 January 2011, the Delft3D flow (FLOW), morphology (MOR) and waves (WAVE) modules are available in open source. The software is used and has proven his capabilities on many places around the world, like the Netherlands, USA, Hong Kong, Singapore, Australia, Venice, etc. The software is continuously improved and developed with innovating advanced modelling techniques as consequence of the research work of our institute and to stay world leading. The FLOW module is the heart of Delft3D and is a multi-dimensional (2D or 3D) hydrodynamic (and transport) simulation program which calculates non-steady flow and transport phenomena resulting from tidal and meteorological forcing on a curvilinear, boundary fitted grid or spherical coordinates. In 3D simulations, the vertical grid is defined following the so-called sigma coordinate approach or Z-layer approach. The MOR module computes sediment transport (both suspended and bed total load) and morphological changes for an arbitrary number of cohesive and non-cohesive fractions. Both currents and waves act as driving forces and a wide variety of transport formulae have been incorporated. For the suspended load this module connects to the 2D or 3D advection-diffusion solver of the FLOW module; density effects may be taken into account. An essential feature of the MOR module is the dynamic feedback with the FLOW and WAVE modules, which allow the flows and waves to adjust themselves to the local bathymetry and allows for simulations on any time scale from days (storm impact) to centuries (system dynamics). It can keep track of the bed composition to build up a stratigraphic record. The MOR module may be extended to include extensive features to simulate dredging and dumping scenarios. For over 30 years Deltares has been in the forefront of these types of combined morphological simulation techniques.”

Chartand, Chris↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SolOpt: A Novel Approach to Solar Rooftop Optimization

Traditionally Photovoltaic Technology (PV) and Solar Hot Water Technology (SHW) have been designed with separate design tools, making it difficult to determine the appropriate mix of PV and SHW. A new tool developed at the National Renewable Energy Laboratory changes how the analysis is conducted through an integrated approach based on the life cycle cost effectiveness of each system. With 10 inputs someone with only basic knowledge of the building can simulate energy production from PV and SHW, and predict the optimal sizes of the systems. The user can select from four optimization criteria currently available: Greenhouse Gas Reduction, Net-Present Value, Renewable Energy Production, and Discounted Payback Period. SolOpt provides unique analysis capabilities that aren't currently available in any other software programs. Validation results with industry accepted tools for both SHW and PV are presented.

14 SOLAR ENERGY↗

Recent Developments in the Design of Vertical Borehole Ground Heat Exchangers for Cost Reduction and Thermal Energy Storage

Ground source (geothermal) heat pumps (GSHPs) can meet the thermal demands of buildings in an energy-efficient manner. The current high installation costs and long payback period limit the attractiveness of GSHP installation in the United States. Vertical borehole ground heat exchangers (VBGHEs), which are commonly used in GSHP systems, contribute most to the cost premium of GSHPs. Reducing the cost of VBGHEs could help increase market penetration of GSHP systems. This paper reviews recent developments for VBGHEs, including improvements in borehole heat transfer and borehole field layout, integration with thermal energy storage, and new design tools. Improvements in the borehole design and materials are more likely to be justified when the ground has high thermal conductivity. Integrating thermal energy storage can provide additional value to the GSHP system, especially when flexible electric demand at buildings becomes more valuable. Here, advanced design tools for VBGHEs that account for the thermal response of irregularly shaped borehole fields and that are more closely integrated with whole-building energy simulation programs may facilitate more innovations and optimization of GSHP system designs.

15 GEOTHERMAL ENERGY↗

Review of WEC-Sim Development and Applications

WEC-Sim (Wave Energy Converter Simulator) is an open-source code for simulating wave energy converters that has been actively developed and applied to simulate a wide variety of device archetypes, and has become a popular tool since its release. This paper reviews the development efforts and usage of WEC-Sim. The publications considered in this study have been broken down into six topic areas, namely, feature development, experimental validation, device modelling, control modelling, powertake-off (PTO) and grid modelling, and novel applications, which includes some non-wave energy applications. This review paper also recognizes the contributions of academic researchers and technology developers from around the world toward the broader WEC-Sim development effort. The growing number of external applications of WEC-Sim demonstrates a broader acceptance of the open-source code, and the ways WEC-Sim has been used in certain topic areas also highlight potential future development needs.

applications↗

Nalu-Wind v.1.2.0

Nalu-Wind is derived from Nalu-CFD (for which Sandia has an existing copyright assertion). Nalu-Wind is specific to the wind energy simulation space. SAND2019-10379 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Crozier, Paul↗

SAM Process Heat Model Development and Validation: Liquid-HTF Trough and Direct Steam Generation Linear Focus Systems

Two new solar industrial process heat (SIPH) models have been added to the System Advisor Model (SAM) energy simulation tool. The two process heat models were: i) liquid-heat transfer fluid (HTF) parabolic troughs; and ii) direct steam generation (DSG) linear-focus collectors. The DSG model can simulate either DSG parabolic troughs (PT) or DSG Linear Fresnel (LF) fields, based on the optical characteristics supplied. These models help to meet the need for independent, validated tools that reliably simulate the effects of adding a solar field to provide heat for potential IPH applications. During the pre-validation of the liquid-HTF model, operational data was provided and preprocessed by SPF and evaluated at ZAE Bayern. The beta liquid-HTF model provided excellent agreement between the simulations and the operational data for the solar thermal yield generation on a yearly and monthly basis (4.4% difference). The final liquid-HTF process heat model has been further optimized with test users such as ZAE Bayern and SPF. Key improvements in the SIPH models to better model SIPH fields include the use of smaller piping systems and heat capacities, a single collector field, and a higher time-step resolution than for electricity generation (down to 10 minutes). Both the final liquid-HTF and DSG models were successfully validated against operational data for respective solar fields, and showed less than 5% deviation to actual results. A brief application where the liquid-HTF process heat model is used for a brewery in California and the value of reliably simulating a potential SIPH solar field are highlighted.

14 SOLAR ENERGY↗

Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of urban transportation mode split on CO{sub 2} emissions in Jinan, China.

As the world's largest developing country, China currently is undergoing rapid urbanization and motorization, which will result in far-reaching impacts on energy and the environment. According to estimates, energy use and carbon emissions in the transportation sector will comprise roughly 30% of total emissions by 2030. Since the late 1990s, transportation-related issues such as energy, consumption, and carbon emissions have become a policy focus in China. To date, most research and policies have centered on vehicle technologies that promote vehicle efficiency and reduced emissions. Limited research exists on the control of greenhouse gases through mode shifts in urban transportation - in particular, through the promotion of public transit. The purpose of this study is to establish a methodology to analyze carbon emissions from the urban transportation sector at the Chinese city level. By using Jinan, the capital of China's Shandong Province, as an example, we have developed an analytical model to simulate energy consumption and carbon emissions based on the number of trips, the transportation mode split, and the trip distance. This model has enabled us to assess the impacts of the transportation mode split on energy consumption and carbon emissions. Furthermore, this paper reviews a set of methods for data collection, estimation, and processing for situations where statistical data are scarce in China. This paper also describes the simulation of three transportation system development scenarios. The results of this study illustrate that if no policy intervention is implemented for the transportation mode split (the business-as-usual (BAU) case), then emissions from Chinese urban transportation systems will quadruple by 2030. However, a dense, mixed land-use pattern, as well as transportation policies that encourage public transportation, would result in the elimination of 1.93 million tons of carbon emissions - approximately 50% of the BAU scenario emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Market Driven Residential Energy Codes: Comparing Performance in a Changing Technological Environment

The research project is undertaken to better understand the changing relationship between the two basic methods of building energy code compliance – prescriptive and performance – and how those methods relate to each other with respect to advancements in building energy computer simulation standards and capabilities. The International Energy Efficiency Code (IECC) is a model code adopted by many jurisdictions across the United States. Historically, the prescriptive compliance methodology has been preferred in most jurisdictions. The prescriptive methodology requires meeting or exceeding specific efficiency minimums for each envelope component. This tends to be a simple method to teach and verify. A more involved prescriptive alternative called the Total UA alternative is sometimes used. This method requires some multiplication, summing, and comparison to compute, so it is done with a fairly simple computer program. However, advances in computer and building energy simulation technology have resulted in increased use of more detailed performance compliance methods. The performance compliance method establishes the annual energy cost threshold via hourly simulation models. The compliance threshold is determined with a comparison building model simulation with geometry similar to the proposed home and with energy feature parameters and efficiencies as specified in the IECC. This project examines relationships between the two methods of building energy code compliance, including: • Overall annual energy use based on utility bill analysis by compliance method • Code official work processes with respect to compliance methods • Gaps and issues associated with building code compliance methods • Simulated energy use difference between compliance methods • Code compliance cost as a function of compliance method • Code compliance labeling effectiveness for high performance residences • Getting to net zero energy use and net zero greenhouse gas emissions through high performance code alternatives • Electronic code permitting and compliance alternatives

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Validation of the Community Land Model Version 5 over the Contiguous United States (CONUS) using in-situ and remote sensing datasets

The Community Land Model (CLM) is an effective tool to simulate the biophysical and biogeochemical processes and their interactions with the atmosphere. Although CLM Version 5 (CLM5) constitutes various updates in these processes, its performance in simulating energy, water and carbon cycles over the Contiguous United States (CONUS) at scales which land surface changes and hydrometeorological and hydroclimatological applications are more locally relevant is yet to be assessed. In this study, we conducted three simulations at 0.125? during 1979-2018 over the CONUS using different configurations of CLM, namely CLM5-biogeochemistry (CLM5BGC), CLM4.5BGC, and CLM5-satellite phenology (CLM5SP). We validated and compared their simulations against multiple remote-sensed and in-situ datasets. Overall, the parametric and structural updates (e.g., carbon cost for nitrogen uptake, variable soil thickness, dry surface layer) in CLM5 improve its ability in capturing terrestrial biogeochemical dynamics. The low evapotranspiration in CLM5BGC is associated with biases in simulating vegetation phenological characteristics rather than soil water limitations. The mismatch between CLM5BGC-simulated peak leaf area index and reference data can be attributed to CLM5BGC's inability in simulating phenology of trees and grasses. The differences between CLM-simulated irrigation and reference estimates can be attributed to differences between processes represented in models and in reality, and uncertainties in input and validation datasets. Evaluation against observations at small catchments suggest that hydrologic parameters needed to be calibrated to improve simulations of runoff, especially subsurface runoff. Additional efforts are needed to incorporate spatially-distributed plant phenology and physiology parameters and regional-specific agricultural management practices (e.g., planting, harvest).

54 ENVIRONMENTAL SCIENCES↗