Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An approach to the parametric design of ion thrusters

A methodology that can be used to determine which of several physical constraints can limit ion thruster power and thrust, under various design and operating conditions, is presented. The methodology is exercised to demonstrate typical limitations imposed by grid system span-to-gap ratio, intragrid electric field, discharge chamber power per unit beam area, screen grid lifetime, and accelerator grid lifetime constraints. Limitations on power and thrust for a thruster defined by typical discharge chamber and grid system parameters when it is operated at maximum thrust-to-power are discussed. It is pointed out that other operational objectives such as optimization of payload fraction or mission duration can be substituted for the thrust-to-power objective and that the methodology can be used as a tool for mission analysis.

Wilbur, Paul J.↗

An approach to the parametric design of ion thrusters

A methodology that can be used to determine which of several physical constraints can limit ion thruster power and thrust, under various design and operating conditions, is presented. The methodology is exercised to demonstrate typical limitations imposed by grid system span-to-gap ratio, intragrid electric field, discharge chamber power per unit beam area, screen grid lifetime and accelerator grid lifetime constraints. Limitations on power and thrust for a thruster defined by typical discharge chamber and grid system parameters when it is operated at maximum thrust-to-power are discussed.

Wilbur, Paul J.↗

High pressure hypervelocity electrothermal wind tunnel performance study and subscale tests

The feasibility of a Mach 10 to 20, high pressure electrothermal wind tunnel was assessed. A heater based on a continuous high power electric arc discharge capable of heating air to temperatures above 10,000 K and pressures of 15,000 atm is the key element of this wind tunnel. Results of analytical study indicate that the facility is capable of simulation conditions suitable for hypervelocity airbreathing propulsion testing up to Mach 16. In this case simulation was limited by pressure containment, high nozzle throat heat flux rates, and chemical freezing in the nozzle. The high total pressure capability improved the recombination chemistry in the facility nozzle as chemical equilibrium prevailed to the freezing point. Steady arc discharges were observed with liquid nitrogen flowing into the arc chamber during tests based on the two millisecond test facility. The measured steady pressure in the arc chamber was 4559 psi, which is two times greater than maximum total pressure obtainable in conventional arc heaters.

Rizkalla, Oussama F.↗

Radiation Shielding Systems Using Nanotechnology

A system for shielding personnel and/or equipment from radiation particles. In one embodiment, a first substrate is connected to a first array or perpendicularly oriented metal-like fingers, and a second, electrically conducting substrate has an array of carbon nanostructure (CNS) fingers, coated with an electro-active polymer extending toward, but spaced apart from, the first substrate fingers. An electric current and electric charge discharge and dissipation system, connected to the second substrate, receives a current and/or voltage pulse initially generated when the first substrate receives incident radiation. In another embodiment, an array of CNSs is immersed in a first layer of hydrogen-rich polymers and in a second layer of metal-like material. In another embodiment, a one- or two-dimensional assembly of fibers containing CNSs embedded in a metal-like matrix serves as a radiation-protective fabric or body covering.

Chen, Bin↗

Ultraviolet sensing apparatus with mirror amplification

Systems, methods, and devices of the various embodiments may enable the detection and localization of power line corona discharges and/or electrical arcs by an unmanned aerial vehicle (UAV) including an ultraviolet (UV) sensor and a reflective parabolic dish. In various embodiments, the UV sensor may use the photoelectric effect to sense narrow-band UV photons in a Geiger-Mueller tube and circuit configuration. In various embodiments, the reflective parabolic dish may be fixed relative to the UV sensor and include a reflective concave surface. The reflective concave surface may be configured to reflect narrow-band UV photons toward the UV sensor.

Moore, Andrew J.↗

Battery Pack Shape Optimization using Transient Heat Conduction Coupled with Cell-Discharge Analysis

Battery electric systems exhibit significant time-dependence, especially when evaluated in the context of an aircraft mission profile with continually changing power demands. Additionally, when evaluating battery-powered aircraft concepts, it is important to accurately compute the temperature of the batteries and properly characterize the thermal response of the system. The temperature of the batteries has a significant impact on cell performance, in addition to safety considerations of maintaining battery temperatures below their operating limit. Because of these considerations, battery models for preliminary design and optimization of aircraft should include the capability to accurately compute the temperature distribution within the battery pack. Furthermore, battery pack designs should be as light-weight as possible to maximize the pack energy density, while also considering battery temperature limits. Here, we demonstrate a simultaneous trajectory and shape optimization of a battery pack concept, using a transient heat transfer finite element model coupled with a time-varying cell-discharge battery model to provide this capability. Including the transient finite element problem in the loop enables accurate temperatures that can be passed back to the cell discharge model, while the cell discharge model can supply the finite element model with time-varying heat boundary conditions to the finite element problem, further benefiting the fidelity of the thermal response of the batteries. We first demonstrate the coupling capability between the battery cell-discharge model and the transient finite-element heat transfer through an optimization which computes the optimal current profile for the battery pack while ensuring the battery temperatures remain below their operational limit. We then build on this optimization by adding shape optimization to the problem, which allows us to consider a composite objective function which also minimizes the mass of the battery pack, while also producing an optimal current discharge profile.

Optimization↗

Battery Pack Shape Optimization using Transient Heat Conduction Coupled with Cell-Discharge Analysis

Battery electric systems exhibit significant time-dependence, especially when evaluated in the context of an aircraft mission profile with continually changing power demands. Additionally, when evaluating battery-powered aircraft concepts, it is important to accurately compute the temperature of the batteries and properly characterize the thermal response of the system. The temperature of the batteries has a significant impact on cell performance, in addition to safety considerations of maintaining battery temperatures below their operating limit. Because of these considerations, battery models for preliminary design and optimization of aircraft should include the capability to accurately compute the temperature distribution within the battery pack. Furthermore, battery pack designs should be as light-weight as possible to maximize the pack energy density, while also considering battery temperature limits. Here, we demonstrate a simultaneous trajectory and shape optimization of a battery pack concept, using a transient heat transfer finite element model coupled with a time-varying cell-discharge battery model to provide this capability. The transient finite-element analysis is done using TACS, and the cell-discharge battery model uses OpenMDAO and dymos. Including the transient finite element problem in the loop enables accurate temperatures that can be passed back to the cell discharge model, while the cell discharge model can supply the finite element model with time-varying heat boundary conditions, further benefiting the fidelity of the thermal response of the batteries. We first demonstrate the coupling capability between the battery cell-discharge model and the transient finite-element heat transfer through an optimization which computes the optimal current profile for the battery pack while ensuring the battery temperatures remain below their operational limit. We then build on this optimization by adding shape optimization to the problem, which allows us to consider a composite objective function which also minimizes the mass of the battery pack, while also producing an optimal current discharge profile.

Optimization↗

Electrostatic Charging of the Pathfinder Rover

The Mars Pathfinder mission will send a lander and a rover to the martian surface. Because of the extremely dry conditions on Mars, electrostatic charging of the rover is expected to occur as it moves about. Charge accumulation may result in high electrical potentials and discharge through the martian atmosphere. Such discharge could interfere with the operation of electrical elements on the rover. A strategy was sought to mitigate this charge accumulation as a precautionary measure. Ground tests were performed to demonstrate charging in laboratory conditions simulating the surface conditions expected at Mars. Tests showed that a rover wheel, driven at typical rover speeds, will accumulate electrical charge and develop significant electrical potentials (average observed, 110 volts). Measurements were made of wheel electrical potential, and wheel capacitance. From these quantities, the amount of absolute charge was estimated. An engineering solution was developed and recommended to mitigate charge accumulation. That solution has been implemented on the actual rover.

Siebert, Mark W.↗

Gas ion laser construction for electrically isolating the pressure gauge thereof

The valve and the pressure gauge of a gas ion laser were electrically insulated from the laser discharge path by connecting them in series with the cathode of the laser. The laser cathode can be grounded and preferably is a cold cathode although a hot cathode may be used instead. The cold cathode was provided with a central aperture to which was connected both the pressure gauge and the gas pressure reservoir through the valve. This will effectively prevent electric discharges from passing either to the pressure gauge or the valve which would otherwise destroy the pressure gauge.

Wood, C. E.↗

Response of lead-acid batteries to chopper-controlled discharge

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses at up to 25 percent compared to constant current discharges at the same average discharge current of 100 A. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-A pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

Electrical Charging Hazards Originating from the Surface (ECHOS): Understanding the Martian Electro-Meteorological Environment

In 1999, the NASA/Human Exploration and Development of Space (HEDS) enterprise selected a number of payloads to fly to the Martian surface in an 03 opportunity (prior to the MPL loss). Part of a proposed experiment, ECHOS, was selected to specifically understand the electrical charging hazards from tribocharged dust in the ambient atmosphere, in dust devils, and in larger storms. It is expected that Martian dust storms become tribocharged much like terrestrial dust devils which can possess almost a million elementary charges per cubic centimeter. The ECHOS package features a set of instruments for measuring electric effects: a radio to detect AC electric fields radiating from discharges in the storm,a DC electric field system for sensing electrostatic fields from concentrations of charged dust grains, and a lander electrometer chain for determining the induced potential on its body and MAV (Mars Ascent Vehicle) during the passages of a charged dust storm. Given that electricity is a systemic process originating from wind-blown dust, we also proposed to correlate the electrical measurements with fundamental fluid/meteorological observations, including wind velocity and vorticity, temperature, and pressure. Triboelectricity will also affect local chemistry, and chemical-sensing devices were also considered a feature of the package. The primary HEDS objectives of the ECHOS sensing suite is to discover and monitor the natural electrical hazards associated with dust devils and storms, and determine their enviro-effectiveness on human systems. However, ECHOS also has a strong footprint in the overarching science objectives of the Mars Surveyor Program.

Farrell, W. M.↗

Voltage feed through apparatus having reduced partial discharge

A voltage feed-through apparatus, having reduced partial discharge, has an electrical conductor and an electrical terminal connected thereto. A semiconductor sleeve surrounds the conductor for reducing the electric field concentration at the metallic conductor surface and consequently reducing the partial discharge occurrences. An insulator sleeve encircles the semiconductor sleeve. A metallic sleeve surrounds a portion of the terminal. Another insulator is connected to the metallic sleeve and surrounds a portion of the insulator sleeve forming a space therebetween. Another metallic sleeve spaced from the first metallic sleeve surrounds a portion of the other insulator.

Peck, S. R.↗

Inclusion of Biological Targets in the Analysis of Electrical Characteristics of Non-Thermal Plasma Discharge

In Plasma Medicine studies, the effect of non-thermal plasma (NTP) on biological targets is typically correlated with the amount of stable reactive oxygen and nitrogen species produced in a liquid medium. The effect of NTP and the response of the biological target on cellular redox mechanisms is overlooked in these investigations. Additionally, the influence of electrical properties of cells on the physical properties of NTP is neglected. Therefore, we used a floating electrode dielectric barrier discharge plasma to explore the impact of cell structure, size, and viability of the biological target on the physical properties of NTP. Lissajous figures were used to determine circuit capacitance and energy per cycle during NTP exposure of different cell suspensions. We show that both, structural integrity and active enzymic processes of cells change the electrical properties of NTP. Correlations were also drawn between NTP-produced hydrogen peroxide and nitrite with measured capacitance. Our studies indicate that the observed changes between different cell suspensions may be due to a feedback loop between the biological target and the NTP source. In future studies, a more detailed analysis is needed to improve the control of clinical NTP devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transition from retrograde to prograde drift instabilities in a magnetron microdischarge

Rotating plasma structures, or “spokes,” in magnetized discharges characterized by perpendicular electric and magnetic fields have been seen in a growing number of studies and are believed to be the result of gradient-driven drift instabilities. Under certain conditions, we have shown the spoke’s rotation to be opposite to the E B direction, i.e., retrograde in its expected direction. Recently, we have linked such counter-intuitive rotation to a local inversion of the electric field. Here, we give further experimental evidence for this inversion and attempt to provide an explanation for a relatively distinct transition seen between retrograde and positive (prograde) drift. In the experiments, a partially magnetized plasma forms inside a magnetron device of mm radius operated with argon. Discharge current–voltage measurements are acquired for a range of argon fill pressure and inter-electrode spacing. We find two branches of operation—a low current branch of negative resistance, coinciding with the retrograde spoke rotation, and a higher current branch of positive resistance, coincident with prograde spoke rotation. We postulate that at low discharge currents, high magnetic field confinement leads to a large density gradient, causing more electron transport to the anode than that demanded by the external circuit. At higher currents, anomalous axial electron transport (across the magnetic field lines) becomes dominant, eliminating the conditions for field inversion. Here, the current thresholds for the field inversion are found to be sensitive to the argon pressure and inter-electrode spacing.

42 ENGINEERING↗

Crane-Load Contact Sensor

An electronic instrument has been developed as a prototype of a portable crane-load contact sensor. Such a sensor could be helpful in an application in which the load rests on a base in a horizontal position determined by vertical alignment pins (see Figure 1). If the crane is not positioned to lift the load precisely vertically, then the load can be expected to swing once it has been lifted clear of the pins. If the load is especially heavy, large, and/or fragile, it could hurt workers and/or damage itself and nearby objects. By indicating whether the load remains in contact with the pins when it has been lifted a fraction of the length of the pins, the crane-load contact sensor helps the crane operator determine whether it is safe to lift the load clear of the pins: If there is contact, then the load is resting against the sides of the pins and, hence, it may not be safe to lift; if contact is occasionally broken, then the load is probably not resting against the pins, so it should be safe to lift. It is assumed that the load and base, or at least the pins and the surfaces of the alignment holes in the load, are electrically conductive, so the instrument can use electrical contact to indicate mechanical contact. However, DC resistance cannot be used as an indicator of contact for the following reasons: The load and the base are both electrically grounded through cables (the load is grounded through the lifting cable of the crane) to prevent discharge of static electricity. In other words, the DC resistance between the load and the pins is always low, as though they were always in direct contact. Therefore, instead of DC resistance, the instrument utilizes the AC electrical impedance between the pins and the load. The signal frequency used in the measurement is high enough (.1 MHz) that the impedance contributed by the cables and the electrical ground network of the building in which the crane and the base are situated is significantly greater than the contact impedance between the pins and the load. The instrument includes a signal generator and voltage-measuring circuitry, and is connected to the load and the base as shown in Figure 2. The output of the signal generator (typically having amplitude of the order of a volt) is applied to the load via a 50-resistor, and the voltage between the load and the pins is measured. When the load and the pins are not in contact, the impedance between them is relatively high, causing the measured voltage to exceed a threshold value. When the load and the pins are in contact, the impedance between them falls to a much lower value, causing the voltage to fall below the threshold value. The voltage-measuring circuitry turns on a red light-emitting diode (LED) to indicate the lower-voltage/ contact condition. Whenever the contact has been broken and the non-contact/higher-voltage condition has lasted for more than 2 ms, the voltage-measuring circuitry indicates this condition by blinking a green LED.

Youngquist, Robert↗

Response of lead-acid batteries to chopper-controlled discharge: Preliminary results

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses up to 25 percent compared to constant current discharges at the same average discharge current of 100 amperes. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-ampere pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗