Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EQUIPMENT INTERFACES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Materials Science Clean Room Facility at Tulane University (Final Technical Report)

The project involves conversion of a 3,000 sq. ft. area into a clean room facility for materials science research. It will be accomplished in phases. Phase I will involve preparation of the existing space, acquisition and installation of clean room equipped with a pulsed laser deposition (PLD) processing system, and conversion of ancillary space to facilitate the interface with the clean room. From a capital perspective, Phases II and III will involve the acquisition of additional processing, fabrication, and characterization equipment and capabilities.

36 MATERIALS SCIENCE↗

Coupling Rydberg atoms to superconducting qubits via nanomechanical resonator

We propose a hybrid system to realize long information storage and fast quantum operation via Rydberg atoms and superconducting qubits (SCQs). The internal states of a Rydberg atom are coupled to a nanomechanical resonator. The atom-resonator coupling is achieved via an electric field generated by the quantized motions of the resonator and temporarily exciting the atom to Rydberg states. The coupling can be made large enough to allow quantum manipulation and measurement of the resonator via the atom. The resonator can also be coupled to a SCQ, and therefore the tripartite system can provide a quantum interface between the SCQ and the atom via the nanomechanical resonator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Elemental distribution and oxygen deficiency of magnetron sputtered indium tin oxide films

The atomic structure and composition of noninterfacial ITO and ITO-Si interfaces were studied with transmission electron microscopy and x-ray photoelectron spectroscopy (XPS). The films were deposited by dc magnetron sputtering on monocrystalline p-type (100) Si wafers. Both as deposited and heat treated films consisted of crystalline ITO. The ITO/Si interface showed a more complicated composition. A thin layer of SiO{sub x} was found at the ITO/Si interface together with In and Sn nanoclusters, as well as highly oxygen deficient regions, as observed by XPS. High energy electron exposure of this area crystallized the In nanoclusters and at the same time increased the SiO{sub x} interface layer thickness.

36 MATERIALS SCIENCE↗

Direct in situ measurement of specific capacitance, monolayer tension, and bilayer tension in a droplet interface bilayer

In this study, thickness and tension are important physical parameters of model cell membranes. However, traditional methods to measure these quantities require multiple experiments using separate equipment. This work introduces a new multi-step procedure for directly accessing in situ multiple physical properties of droplet interface bilayers (DIB), including specific capacitance (related to thickness), lipid monolayer tension in the Plateau-Gibbs border, and bilayer tension. The procedure employs a combination of mechanical manipulation of bilayer area followed by electrowetting of the capacitive interface to examine the sensitivities of bilayer capacitance to area and contact angle to voltage, respectively. These data allow for determining the specific capacitance of the membrane and surface tension of the lipid monolayer, which are then used to compute bilayer thickness and tension, respectively. The use of DIBs affords accurate optical imaging of the connected droplets in addition to electrical measurements of bilayer capacitance, and it allows for reversibly varying bilayer area. After validating the accuracy of the technique with diphytanoyl phosphatidylcholine (DPhPC) DIBs in hexadecane, the method is applied herein to quantify separately the effects on membrane thickness and tension caused by varying the solvent in which the DIB is formed and introducing cholesterol into the bilayer. Because the technique relies only on capacitance measurements and optical images to determine both thickness and tension, this approach is specifically well-suited for studying the effects of peptides, biomolecules, natural and synthetic nanoparticles, and other species that accumulate within membranes without altering bilayer conductance.

59 BASIC BIOLOGICAL SCIENCES↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Effects of porous carbon additives and induced fluorine on low dielectric constant polyimide synthesized with an e-beam

We report the synthesis of a polyimide matrix with a low dielectric constant for application as an intercalation material between metal interconnections in electronic devices. Porous activated carbon was embedded in the polyimide to reduce the dielectric constant, and a thin film of the complex was obtained using the spin-coating and e-beam irradiation methods. The surface of the thin film was modified with fluorine functional groups to impart water resistance and reduce the dielectric constant further. The water resistance was significantly improved by the modification with hydrophobic fluorine groups. The dielectric constant was effectively decreased by porous activated carbon. The fluorine modification also resulted in a low dielectric constant on the polyimide surface by reducing the polar surface free energy. The dielectric constant of polyimide film decreased from 2.98 to 1.9 by effects of porous activated carbon additive and fluorine surface modification.

36 MATERIALS SCIENCE↗

10 ps resolution, 160 ns full scale range and less than 1.5% differential non-linearity time-to-digital converter module for high performance timing measurements

We present a compact high performance time-to-digital converter (TDC) module that provides 10 ps timing resolution, 160 ns dynamic range and a differential non-linearity better than 1.5% LSB{sub rms}. The TDC can be operated either as a general-purpose time-interval measurement device, when receiving external START and STOP pulses, or in photon-timing mode, when employing the on-chip SPAD (single photon avalanche diode) detector for detecting photons and time-tagging them. The instrument precision is 15 ps{sub rms} (i.e., 36 ps{sub FWHM}) and in photon timing mode it is still better than 70 ps{sub FWHM}. The USB link to the remote PC allows the easy setting of measurement parameters, the fast download of acquired data, and their visualization and storing via an user-friendly software interface. The module proves to be the best candidate for a wide variety of applications such as: fluorescence lifetime imaging, time-of-flight ranging measurements, time-resolved positron emission tomography, single-molecule spectroscopy, fluorescence correlation spectroscopy, diffuse optical tomography, optical time-domain reflectometry, quantum optics, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Programmable data communications controller requirements

The design requirements for a Programmable Data Communications Controller (PDCC) that reduces the difficulties in attaching data terminal equipment to a computer are presented. The PDCC is an interface between the computer I/O channel and the bit serial communication lines. Each communication line is supported by a communication port that handles all line control functions and performs most terminal control functions. The port is fabricated on a printed circuit board that plugs into a card chassis, mating with a connector that is joined to all other card stations by a data bus. Ports are individually programmable; each includes a microprocessor, a programmable read-only memory for instruction storage, and a random access memory for data storage.

Source record↗

High Resolution Imager (HRI) for the Roentgen Satellite (ROSAT) definition study

The design of the high resolution imager (HRI) on HEAO 2 was modified for use in the instrument complement of the Roentgen Satellite (ROSAT). Mechanical models of the front end assembly, central electronics assembly, and detector assembly were used to accurately represent the HRI envelope for both fit checks and focal plane configuration studies. The mechanical and electrical interfaces were defined and the requirements for electrical ground support equipment were established. A summary description of the ROSAT telescope and mission is included.

Source record↗

Concept of a programmable maintenance processor applicable to multiprocessing systems

A programmable maintenance processor concept applicable to multiprocessing systems has been developed at the NASA Ames Research Center's Dryden Flight Research Facility. This stand-alone-processor is intended to provide support for system and application software testing as well as hardware diagnostics. An initial machanization has been incorporated into the extended aircraft interrogation and display system (XAIDS) which is multiprocessing general-purpose ground support equipment. The XAIDS maintenance processor has independent terminal and printer interfaces and a dedicated magnetic bubble memory that stores system test sequences entered from the terminal. This report describes the hardware and software embodied in this processor and shows a typical application in the check-out of a new XAIDS.

Glover, Richard D.↗

Multimodal user input to supervisory control systems - Voice-augmented keyboard

The use of a voice-augmented keyboard input modality is evaluated in a supervisory control application. An implementation of voice recognition technology in supervisory control is proposed: voice is used to request display pages, while the keyboard is used to input system reconfiguration commands. Twenty participants controlled GT-MSOCC, a high-fidelity simulation of the operator interface to a NASA ground control system, via a workstation equipped with either a single keyboard or a voice-augmented keyboard. Experimental results showed that in all cases where significant performance differences occurred, performance with the voice-augmented keyboard modality was inferior to and had greater variance than the keyboard-only modality. These results suggest that current moderately priced voice recognition systems are an inappropriate human-computer interaction technology in supervisory control systems.

Mitchell, Christine M.↗

Improving A Remote Manipulator

Set of three reports describes work on Protoflight Manipulator Assembly (PFMA). "Performance Characteristics of Protoflight Manipulator Assembly" presents parameters of PFMA after refurbishment of operating components. "End Effector and Task Board Development for the Protoflight Manipulator Assembly" describes special tools and adaptations allowing PFMA to be used for servicing equipment. "Modular Software Development for the Protoflight Manipulator Assembly" documents interface and control software for PFMA.

Haslam, John W., Jr.↗

A (13)C NMR analysis of the effects of electron radiation on graphite/polyetherimide composites

Initial investigations have been made into the use of high resolution nuclear magnetic resonance (NMR) for the characterization of radiation effects in graphite and Kevlar fibers, polymers, and the fiber/matrix interface in graphite/polyetherimide composites. Sample preparation techniques were refined. Essential equipment has been procured. A new NMR probe was constructed to increase the proton signal-to-noise ratio. Problem areas have been identified and plans developed to resolve them.

Ferguson, Milton W.↗

On-orbit operations of the Space Station Freedom attached payloads accommodations equipment

The Space Station Freedom which will serve as a base of operations for instruments performing space science is discussed. The Attached Payload Accommodation Equipment (APAE) will be a set of equipment designed to provide standard structural, power, data and thermal interfaces between payloads and the space station. The APAE is designed to minimize and simplify the on-orbit operations required for payload installation, replacement, and servicing. In addition, the APAE supplies launch support for small payloads and attitude control for payloads that required it.

Lane, Jean Folse↗

Conceptual definition of a high voltage power supply test facility

NASA Lewis Research Center is presently developing a 60 GHz traveling wave tube for satellite cross-link communications. The operating voltage for this new tube is - 20 kV. There is concern about the high voltage insulation system and NASA is planning a space station high voltage experiment that will demonstrate both the 60 GHz communications and high voltage electronics technology. The experiment interfaces, requirements, conceptual design, technology issues and safety issues are determined. A block diagram of the high voltage power supply test facility was generated. It includes the high voltage power supply, the 60 GHz traveling wave tube, the communications package, the antenna package, a high voltage diagnostics package and a command and data processor system. The interfaces with the space station and the attached payload accommodations equipment were determined. A brief description of the different subsystems and a discussion of the technology development needs are presented.

Biess, John J.↗

Alternative methods to model frictional contact surfaces using NASTRAN

Elongated (slotted) holes have been used extensively for the integration of equipment into Spacelab racks. In the past, this type of interface has been modeled assuming that there is not slippage between contact surfaces, or that there is no load transfer in the direction of the slot. Since the contact surfaces are bolted together, the contact friction provides a load path determined by the normal applied force (bolt preload) and the coefficient of friction. Three alternate methods that utilize spring elements, externally applied couples, and stress dependent elements are examined to model the contacted surfaces. Results of these methods are compared with results obtained from methods that use GAP elements and rigid elements.

Hoang, Joseph↗

Extravehicular activity technology discipline

Viewgraphs on extravehicular activity technology discipline for Space Station Freedom are presented. Topics covered include: extravehicular mobility unit; airlock and EMU support equipment; tools, mobility aids, and workstations; and telerobotic work aids interfaces.

Webbon, Bruce W.↗