Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

OBSERVATIONS OF THE NEAR-INFRARED SPECTRUM OF THE ZODIACAL LIGHT WITH CIBER

Interplanetary dust (IPD) scatters solar radiation which results in the zodiacal light that dominates the celestial diffuse brightness at optical and near-infrared wavelengths. Both asteroid collisions and cometary ejections produce the IPD, but the relative contribution from these two sources is still unknown. The low resolution spectrometer (LRS) onboard the Cosmic Infrared Background ExpeRiment (CIBER) observed the astrophysical sky spectrum between 0.75 and 2.1 {mu}m over a wide range of ecliptic latitude. The resulting zodiacal light spectrum is redder than the solar spectrum, and shows a broad absorption feature, previously unreported, at approximately 0.9 {mu}m, suggesting the existence of silicates in the IPD material. The spectral shape of the zodiacal light is isotropic at all ecliptic latitudes within the measurement error. The zodiacal light spectrum, including the extended wavelength range to 2.5 {mu}m using Infrared Telescope in Space (IRTS) data, is qualitatively similar to the reflectance of S-type asteroids. This result can be explained by the proximity of S-type asteroidal dust to Earth's orbit, and the relatively high albedo of asteroidal dust compared with cometary dust.

79 ASTRONOMY AND ASTROPHYSICS↗

Wind and Temperature Consensus at Horn Point, HU-Beltsville, Piney Run (Maryland) in support of CoURAGE

The Maryland Department of the Environment (MDE) operates a ground-based atmospheric profiling network consisting of collocated radar wind profilers (RWP) and radio acoustic sounding systems (RASS) as part of its Ambient Air Monitoring Program. This network provides continuous observations of wind and temperature structure in the lower troposphere to support air quality forecasting, regulatory analysis, and atmospheric research. The network currently includes three fixed sites across Maryland: Horn Point (HP, lower eastern shore) [38.587525°,-76.141006°], Howard University-Beltsville (HUB, central Maryland) [39.055277°, -76.878632°], and Piney Run (PR, western Maryland) [39.705950°, -79.012000°] The network is designed to capture regional variability in atmospheric transport and boundary-layer processes. These systems measure vertical profiles of horizontal wind speed and direction using Doppler radar techniques, with observations typically spanning from ~100 m above ground level up to approximately 2.5–4 km. Measurements are derived from the Doppler shift of backscattered electromagnetic signals, enabling retrieval of wind vectors at multiple altitudes with high temporal resolution (e.g., 30-minute averages reported every 6 minutes). Each radar wind profiler is paired with a Radio Acoustic Sounding System (RASS) to provide profiles of virtual temperature in the lower atmosphere (~100–200 m AGL) by measuring the propagation speed of acoustic waves. Together, the RWP/RASS system yields a coupled data set of thermodynamic and kinematic atmospheric structure, including additional parameters such as vertical velocity, radial velocity, signal-to-noise ratio, and spectral width for advanced analysis. There are two types of files for each station: wind data (files with a "w" prefix) and virtual temperature RASS data (files with a "t" prefix). The wind data files are in the format wYYDDD.cns, where YY is the 2-digit year and DDD is the day of the year. The RASS virtual temperature data files are in the format tYYDDD.cns. Each record has the following header structure: Line 1 : Station Name RASS files Line 2 : RASS rev DeTect_2.0, WINDS files Line 2 : WINDS rev ATI 5.1 Line 3 : N latitude, W longitude, and site elevation (m) Line 4 : Date and begin time of consensus: yy mm dd hh mn ss plus # minutes to add to get UTC Line 5 : Consensus averaging time (minutes); number of beams; number of range gates Line 6 : Number of records required to make consensus (num) total number of records (tot) and the consensus window size (m/s) in the format: num:tot (window) RASS files Line 7 : no. of coded cells, no. of spec, pulse width (ns), and inter-pulse period (µs), WINDS files Line 7 : No. of coded cells, no. of spectra, pulse width (ns), and inter-pulse period (µs), each with a pair of values: first value is for oblique beams, second for vertical RASS files Line 8 : Full scale Doppler value (m/s) Delay to first gate (ns) Number of gates Spacing of gates (ns), WINDS files Line 8 : Full scale Doppler velocity (m/s), oblique and vertical Vertical correction applied to oblique beams? (0 = no, 1 = yes) Delay to first gate (ns), oblique and vertical Number of gates, oblique and vertical Spacing of gates (ns), oblique and vertical Line 9 : Azimuth and elevation (9s indicate vertical beam not used) RASS files Line 10, values : HT = Height above ground (km), T = Uncorrected virtual temperature consensus (deg C), Tc = Corrected virtual temperature consensus (deg C), W = Vertical wind consensus (9s indicate vertical beam not used, w-component, positive upward, m/s), CNT = Number of records that made consensus (for the 3 values in same order), SNR = Average signal to noise ratio (dB) of records in consensus (same order) WINDS files Line 10, values : HT = Height above ground (km), SPD = Wind speed (m/s), DIR = Wind direction (deg E of N from N), RAD = Radial velocities for each beam (m/s) in order given in azimuth and elevation line (positive toward radar; 9s indicate vertical beam not used, CNT = Number of records that made consensus, SNR = Average signal to noise ratio (dB) of records in consensus

{"wind speed and direction",temperature}↗

COMPARISON OF THEORY AND MEASUREMENTS OF A TWO-STAGE LIGHT-GAS GUN

A comparison of techniques for obtaining projectile velocity history on a two-stage launcher and discuss gun code accuracy vis-a-vis pressure gauges and the new photonic Doppler velocimetry (PDV) technique is presented. The PDV technique itself is described in a companion paper. The PDV records were differentiated to compute acceleration and, hence, base pressure. Two acceleration episodes are revealed in the data. Base pressure values were compared with measurements from stationary pressure gauges and with predictions of a standard two-stage gun code. The agreement with the pressure gages was satisfactory. Code predictions did not account for the two acceleration stages. However, for the main acceleration episode, the predicted base pressure is in good agreement with the smoothed pressure computed from the PDV record. Both the gauge records and PDV contain short-time pressure spikes which are apparently real. Therefore, use of computed base pressure for projectile design may lead to failures if the projectile is vulnerable to pressure spikes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time Relativity in the Dynamics of Open Quantum Systems

When describing the dynamics of quantum systems interacting with a coherent external electromagnetic field, the instant at which the exciting (measuring) field begins to act is traditionally taken as zero time in the laboratory frame. Using the concept of coherence sudden death in an observed quantum system, we introduce the definition of local, completely incoherent subensembles of the quantum system in which it is found with a certain probability at each instant of time in the process of a continuous observation (measurement). For such subensembles an arbitrary instant of time in the laboratory frame is the initial time of the interaction with the external (measuring) field. As a result, the dynamics of an open quantum system is represented by a superposition of the dynamics of local subsystems with a continuous distribution of the times at which the interaction with the external field begins. We have derived an expression for the dynamical “multitime” contribution to the stationary solution of the Bloch equations, which clearly demonstrates the meaning of time relativity in the dynamics of two-level quantum systems in the semiclassical approximation. This dynamical multitime contribution is shown to explain the emergence of quantum beats at zero frequency (the Hanle effect, the level crossing) in EPR.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of Prototypes for the ALICE Electromagnetic Calorimeter

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A 4 x 4 array of final design modules showed an energy resolution of about 11%/{radical}E(GeV) {circle_plus} 1.7% with a uniformity of the response to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV. The electromagnetic shower position resolution was found to be described by 1.5 mm {circle_plus} 5.3 mm/{radical}E(GeV). For an electron identification efficiency of 90% a hadron rejection factor of >600 was obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CASSINI UVIS STELLAR OCCULTATION OBSERVATIONS OF SATURN's RINGS

The Cassini spacecraft's Ultraviolet Imaging Spectrograph (UVIS) includes a high-speed photometer (HSP) that has observed more than 100 stellar occultations by Saturn's rings. Here, we document a standardized technique applied to the UVIS-HSP ring occultation datasets delivered to the Planetary Data System as higher level data products. These observations provide measurements of ring structure that approaches the scale of the largest common ring particles ({approx}5 m). The combination of multiple occultations at different viewing geometries enables reconstruction of the three-dimensional structure of the rings. This inversion of the occultation data depends on accurate calibration of the data so that occultations of different stars taken at different times and under different viewing conditions can be combined to retrieve ring structure. We provide examples of the structure of the rings as seen from several occultations at different incidence angles to the rings, illustrating changes in the apparent structure with viewing geometry.

79 ASTRONOMY AND ASTROPHYSICS↗

ELECTROMAGNETIC SPINDOWN OF A TRANSIENT ACCRETING MILLISECOND PULSAR DURING QUIESCENCE

The measured spindown rates in quiescence of the transient accreting millisecond pulsars IGR J00291+5934, XTE J1751–305, SAX J1808.4–3658, and Swift J1756.9–2508 have been used to estimate the magnetic moments of these objects assuming standard magnetic dipole braking. It is shown that this approach leads to an overestimate if the amount of residual accretion is enough to distort the magnetosphere away from a force-free configuration through magnetospheric mass loading or crushing, so that the lever arm of the braking torque migrates inside the light cylinder. We derive an alternative spindown formula and calculate the residual accretion rates where the formula is applicable. As a demonstration we apply the alternative spindown formula to produce updated magnetic moment estimates for the four objects above. We note that based on current uncertain observations of quiescent accretion rates, magnetospheric mass loading and crushing are neither firmly indicated nor ruled out in these four objects. Because quiescent accretion rates are not measured directly (only upper limits are placed), without more data it is impossible to be confident about whether the thresholds for magnetospheric mass loading or crushing are reached or not.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ARCADE 2 INSTRUMENT

The second generation Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE 2) instrument is a balloon-borne experiment to measure the radiometric temperature of the cosmic microwave background and Galactic and extragalactic emission at six frequencies from 3 to 90 GHz. ARCADE 2 utilizes a double-nulled design where emission from the sky is compared to that from an external cryogenic full-aperture blackbody calibrator by cryogenic switching radiometers containing internal blackbody reference loads. In order to further minimize sources of systematic error, ARCADE 2 features a cold fully open aperture with all radiometrically active components maintained at near 2.7 K without windows or other warm objects, achieved through a novel thermal design. We discuss the design and performance of the ARCADE 2 instrument in its 2005 and 2006 flights.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining parameters of white-dwarf binaries using gravitational-wave and electromagnetic observations

The space-based gravitational wave (GW) detector, evolved Laser Interferometer Space Antenna (eLISA) is expected to observe millions of compact Galactic binaries that populate our Milky Way. GW measurements obtained from the eLISA detector are in many cases complimentary to possible electromagnetic (EM) data. In our previous papers, we have shown that the EM data can significantly enhance our knowledge of the astrophysically relevant GW parameters of Galactic binaries, such as the amplitude and inclination. This is possible due to the presence of some strong correlations between GW parameters that are measurable by both EM and GW observations, for example, the inclination and sky position. In this paper, we quantify the constraints in the physical parameters of the white-dwarf binaries, i.e., the individual masses, chirp mass, and the distance to the source that can be obtained by combining the full set of EM measurements such as the inclination, radial velocities, distances, and/or individual masses with the GW measurements. We find the following 2σ fractional uncertainties in the parameters of interest. The EM observations of distance constrain the chirp mass to ∼15%-25%, whereas EM data of a single-lined spectroscopic binary constrain the secondary mass and the distance with factors of two to ∼40%. The single-line spectroscopic data complemented with distance constrains the secondary mass to ∼25%-30%. Finally, EM data on double-lined spectroscopic binary constrain the distance to ∼30%. All of these constraints depend on the inclination and the signal strength of the binary systems. We also find that the EM information on distance and/or the radial velocity are the most useful in improving the estimate of the secondary mass, inclination, and/or distance.

79 ASTRONOMY AND ASTROPHYSICS↗

Extended Coherence Time on the Clock Transition of Optically Trapped Rubidium

Optically trapped ensembles are of crucial importance for frequency measurements and quantum memories but generally suffer from strong dephasing due to inhomogeneous density and light shifts. We demonstrate a drastic increase of the coherence time to 21 s on the magnetic field insensitive clock transition of {sup 87}Rb by applying the recently discovered spin self-rephasing [C. Deutsch et al., Phys. Rev. Lett. 105, 020401 (2010)]. This result confirms the general nature of this new mechanism and thus shows its applicability in atom clocks and quantum memories. A systematic investigation of all relevant frequency shifts and noise contributions yields a stability of 2.4x10{sup -11{tau}-1/2}, where {tau} is the integration time in seconds. Based on a set of technical improvements, the presented frequency standard is predicted to rival the stability of microwave fountain clocks in a potentially much more compact setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the decay J / ψ → ϕ π 0 η

Based on ( 10.09 ± 0.04 ) × 10 9 J / ψ events collected with the BESIII detector operating at the BEPCII collider, a partial wave analysis of the decay J / ψ → ϕ π 0 η is performed. We observe for the first time two new structures on the ϕ η invariant mass distribution, with significances exceeding 27 σ and 13 σ ; the first with J PC = 1 + − , mass M = ( 1908 ± 6 ( stat ) − 4 + 8 ( sys ) ) MeV / c 2 , and width Γ = ( 175 ± 13 ( stat ) − 16 + 7 ( sys ) ) MeV , the second with J PC = 1 − − , mass M = ( 1992 ± 12 ( stat ) − 6 + 15 ( sys ) ) MeV / c 2 , and width Γ = ( 132 ± 22 ( stat ) − 4 + 17 ( sys ) ) MeV . These measurements provide important input for the strangeonium spectrum. In addition, the f 0 ( 980 ) − a 0 ( 980 ) 0 mixing signal in J / ψ → ϕ f 0 ( 980 ) → ϕ a 0 ( 980 ) 0 and the corresponding electromagnetic decay J / ψ → ϕ a 0 ( 980 ) 0 are measured with improved precision, providing crucial information to understand the nature of a 0 ( 980 ) 0 and f 0 ( 980 ) . Published by the American Physical Society 2024

Ablikim, M.↗

OVERVIEW OF THE ATACAMA COSMOLOGY TELESCOPE: RECEIVER, INSTRUMENTATION, AND TELESCOPE SYSTEMS

The Atacama Cosmology Telescope was designed to measure small-scale anisotropies in the cosmic microwave background and detect galaxy clusters through the Sunyaev-Zel'dovich effect. The instrument is located on Cerro Toco in the Atacama Desert, at an altitude of 5190 m. A 6 m off-axis Gregorian telescope feeds a new type of cryogenic receiver, the Millimeter Bolometer Array Camera. The receiver features three 1000-element arrays of transition-edge sensor bolometers for observations at 148 GHz, 218 GHz, and 277 GHz. Each detector array is fed by free space millimeter-wave optics. Each frequency band has a field of view of approximately 22' x 26'. The telescope was commissioned in 2007 and has completed its third year of operations. We discuss the major components of the telescope, camera, and related systems, and summarize the instrument performance.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CORRELATION BETWEEN DISPERSION MEASURE AND X-RAY COLUMN DENSITY FROM RADIO PULSARS

Pulsars are remarkable objects that emit across the entire electromagnetic spectrum, providing a powerful probe of the interstellar medium. In this study, we investigate the relation between dispersion measure (DM) and X-ray absorption column density N{sub H} using 68 radio pulsars detected at X-ray energies with the Chandra X-Ray Observatory or XMM-Newton. We find a best-fit empirical linear relation of N{sub H} (10{sup 20} cm{sup -2})= 0.30{sup +0.13}{sub -0.09} DM (pc cm{sup -3}), which corresponds to an average ionization of 10{sup +4}{sub -3}%, confirming the ratio of one free electron per 10 neutral hydrogen atoms commonly assumed in the literature. We also compare different N{sub H} estimates and note that some N{sub H} values obtained from X-ray observations are higher than the total Galactic H I column density along the same line of sight, while the optical extinction generally gives the best N{sub H} predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared measurements and simulations of metal meshes in a focused beam

Infrared transmittance measurements of quasioptical filters are often restricted to a focused beam due to the optical design of the spectrometer. In contrast, numerical simulations assume an incident plane wave, which makes it difficult to compare theory with experimental data. We compare transmittance measurements with numerical simulations of square arrays of circular holes in 3-μm thick Cu sheets at angles of incidence from 0° to 20° for both s and p polarizations. These simple structures allow detailed tests of our electromagnetic simulation methods and show excellent agreement between theory and measurement. Measurements in a focused beam are accurately simulated by combining plane wave calculations over a range of angles that correspond to the focal ratio of the incident beam. Similar screens have been used as components of narrow bandpass filters for far-infrared astronomy, but these results show that the transmittance variations with angle of incidence and polarization limit their use to collimated beams at near normal incidence. The simulations are accurate enough to eliminate a costly trial-and-error approach to the design of more complex and useful quasioptical infrared filters and to predict their in-band performance and out-of-band blocking in focused beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Search for Electron Neutrinos in Multiple Topologies with the MicroBooNE Experiment

This note presents the status of the measurement of electron neutrinos from the Fermilab Booster Neutrino Beamline (BNB) with the MicroBooNE experiment. The analysis is aimed at investigating the nature of the low energy excess of electromagnetic activity observed by the MiniBooNE experiment. The $ν_e$ event selection relies on topological and calorimetric information to characterise particles produced in these interactions, leveraging the Pandora multi-algorithm reconstruction framework as well as custom particle identification and pattern recognition tools. Results presented in this note use 5.88 × 10 20 protons on target of data collected between 2015 and 2018. These include the performance of particle identification tools for $\mu/p$ and $e/\gamma$ separation, along with electromagnetic shower calibration with the largest sample of $\pi^0$ events measured on argon. Progress towards the completion of this analysis is shown through the measurement of high-energy charged-current $ν_e$ interactions and their kinematic distributions using both inclusive (1eX) and exclusive (1$e$0$p$0$\pi$ and 1$e$N$p$0$\pi$) channels. Measurements of charged-current $ν_µ$ interactions aimed at constraining flux and cross-section systematic uncertainties are also shown. We present the analysis’ preliminary sensitivity of an electron-like signal hypothesis to the MiniBooNE excess which includes flux, cross-section, and detector systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Restoration of Lead Fluoride Crystals

Due to its relatively high resistance to high radiation, lead fluoride (PbF{sub 2}) crystals are becoming an increasingly popular material of choice for electromagnetic calorimetry, such as for experiments requiring the measurement of high-energy photons in Hall A of Jefferson Lab. For our studies we irradiated the PbF{sub 2} crystals using an electron linear accelerator (LINAC) followed by exposing the crystals to blue light so as to restore the nominal optical properties. This technique of optical bleaching with blue light affords an efficient and low-cost means for reversing the deleterious effects of optical transmission loss in radiation-damaged lead fluoride crystals. Whereas earlier experiments irradiated the PbF{sub 2} samples with 1.1 and 1.3 MeV gammas from {sup 60}Co, we used pulsed beams of energetic electrons from the tunable 25-MeV LINAC at Idaho Accelerator Center of Idaho State University in Pocatello, Idaho. A 20-MeV beam of electrons was targeted onto four separate 19 cm length samples of lead fluoride over periods of 1, 2, and 4 hours yielding doses between 7 kGy and 35 kGy. Samples were then bleached with blue light of wavelength 410-450 nm for periods between 19.5 and 24 hours. We performed this process twice - radiation, bleaching, radiation, and then followed by bleaching again - for each of these four PbF{sub 2} samples. We shall discuss the efficacy of blue light curing on samples that have undergone two cycles of electron irradiation and optical bleaching.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thicker, more efficient superconducting strip-line detectors for high throughput macromolecules analysis

Fast detectors with large area are required in time-of-flight mass spectrometers for high throughput analysis of biological molecules. We fabricated and characterized subnanosecond 1x1 mm{sup 2} NbN superconducting strip-line detectors. The influence of the strip-line thickness on the temporal characteristics and efficiency of the detector for the impacts of keV accelerated molecules is investigated. We find that the increase of thickness improves both efficiency and response time. In the thicker sample we achieved a rise time of 380 ps, a fall time of 1.38 ns, and a higher count rate. The physics involved in this behavior is investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗