Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distance Learning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Photometric redshifts for the S-PLUS Survey: Is machine learning up to the task?

The Southern Photometric Local Universe Survey (S-PLUS) is a novel project that aims to map the Southern Hemisphere using a twelve filter system, comprising five broad-band SDSS-like filters and seven narrow-band filters optimized for important stellar features in the local universe. In this paper we use the photometry and morphological information from the first S-PLUS data release (S-PLUS DR1) cross-matched to unWISE data and spectroscopic redshifts from Sloan Digital Sky Survey DR15. We explore three different machine learning methods (Gaussian Processes with GPz and two Deep Learning models made with TensorFlow) and compare them with the currently used template-fitting method in the S-PLUS DR1 to address whether machine learning methods can take advantage of the twelve filter system for photometric redshift prediction. Using tests for accuracy for both single-point estimates such as the calculation of the scatter, bias, and outlier fraction, and probability distribution functions (PDFs) such as the Probability Integral Transform (PIT), the Continuous Ranked Probability Score (CRPS) and the Odds distribution, we conclude that a deep-learning method using a combination of a Bayesian Neural Network and a Mixture Density Network offers the most accurate photometric redshifts for the current test sample. In conclusion, it achieves single-point photometric redshifts with scatter (σ NMAD ) of 0.023, normalized bias of -0.001, and outlier fraction of 0.64% for galaxies with r_auto magnitudes between 16 and 21.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Metal–Support Interaction Dictates Cu Nanoparticle Sintering on Al 2 O 3 Surfaces

Nanoparticle sintering remains a critical challenge in heterogeneous catalysis. In this work, we present a unified deep potential (DP) model based on the Perdew–Burke–Ernzerhof approximation of density functional theory for Cu nanoparticles on three Al 2 O 3 surfaces (γ-Al 2 O 3 (100), γ-Al 2 O 3 (110), and α-Al 2 O 3 (0001)). Using DP-accelerated simulations, we reveal that the nanoparticle size-mobility relationship strongly depends on the supporting surface. The diffusion of nanoparticles on the two γ-Al 2 O 3 surfaces is almost independent of the size of the nanoparticle, while the diffusion on α-Al 2 O 3 (0001) decreases rapidly with increasing size. Interestingly, nanoparticles with fewer than 55 atoms diffuse several times faster on α-Al 2 O 3 (0001) than on γ-Al 2 O 3 (100) at 800 K while expected to be more sluggish based on their larger binding energy at 0 K. The diffusion on α-Al 2 O 3 (0001) is facilitated by dynamic metal–support interaction (MSI), where Al atoms move out of the surface plane to optimize contact with the nanoparticle and relax back to the plane as the nanoparticle moves away. In contrast, the MSI on γ-Al 2 O 3 (100) and on γ-Al 2 O 3 (110) is dominated by more stable and directional Cu–O bonds, consistent with the limited diffusion observed on these surfaces. Our extended MD simulations provide insight into the sintering processes, showing that the dispersity of the nanoparticles strongly influences the coalescence driven by nanoparticle diffusion. We observed that the coalescence of Cu 13 nanoparticles on α-Al 2 O 3 (0001) can occur in a short time (10 ns) at 800 K even with an initial internanoparticle distance increased to 3 nm, while the coalescence on the two γ-Al 2 O 3 surfaces are inhibited significantly by increasing the initial internanoparticle distance. These findings demonstrate that the dynamics of the supporting surface is crucial to understanding the sintering mechanism and offer guidance for designing sinter-resistant catalysts by engineering the support morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine learning inversion from small-angle scattering for charged polymers

We develop Monte Carlo simulations for uniformly charged polymers and a machine learning algorithm to interpret the intra-polymer structure factor of the charged polymer system, which can be obtained from small-angle scattering experiments. The polymer is modeled as a chain of fixed-length bonds, where the connected bonds are subject to bending energy, and there is also a screened Coulomb potential for charge interaction between all joints. The bending energy is determined by the intrinsic bending stiffness, and the charge interaction depends on the interaction strength and screening length. All three contribute to the stiffness of the polymer chain and lead to longer and larger polymer conformations. The screening length also introduces a second length scale for the polymer besides the bending persistence length. To obtain the inverse mapping from the structure factor to these polymer conformation and energy-related parameters, we generate a large data set of structure factors by running simulations for a wide range of polymer energy parameters. We use principal component analysis to investigate the intra-polymer structure factors and determine the feasibility of the inversion using the nearest neighbor distance. We employ Gaussian process regression to achieve the inverse mapping and extract the characteristic parameters of polymers from the structure factor with low relative error.

36 MATERIALS SCIENCE↗

The DECam MAGIC Survey: Spectroscopic Follow-up of the Most Metal-poor Stars in the Distant Milky Way Halo *

In this work, we present high-resolution spectroscopic observations for six metal-poor stars with [Fe/H] < –3 (including one with [Fe/H] < –4), selected using narrowband Ca ii HK photometry from the DECam MAGIC Survey. The spectroscopic data confirm the accuracy of the photometric metallicities and allow for the determination of chemical abundances for 16 elements, from carbon to barium. The program stars have chemical abundances consistent with the [Fe/H] < –3 range. A kinematic/dynamical analysis suggests that all program stars belong to the distant Milky Way halo population (heliocentric distances 35 < d helio /kpc ≲ 55), including three with high-energy orbits that might have been associated with the Magellanic system and one, J0026−5445, having parameters consistent with being a member of the Sagittarius stream. The remaining two stars show kinematics consistent with the Gaia-Sausage/Enceladus dwarf galaxy merger. J0433−5548, with [Fe/H] = –4.12, is a carbon-enhanced ultra metal-poor star, with [C/Fe] = +1.73. This star is believed to be a bona fide second-generation star, and its chemical abundance pattern was compared with yields from metal-free supernova models. Results suggest that J0433−5548 could have been formed from a gas cloud enriched by a single supernova explosion from an ∼11 M ⊙ star in the early Universe. The successful identification of such objects demonstrates the reliability of photometric metallicity estimates, which can be used for target selection and statistical studies of faint targets in the Milky Way and its satellite population. These discoveries illustrate the power of measuring chemical abundances of metal-poor Milky Way halo stars to learn more about early galaxy formation and evolution.

CEMP stars↗

Filament-induced breakdown spectroscopy signal enhancement using optical wavefront control

Filament-induced breakdown spectroscopy (FIBS) is an analytical method that holds significant promise for remote sensing. In FIBS, it is desirable to maximize the intensity and improve the reproducibility of a selected spectroscopic feature. Here, we demonstrate the use of wavefront control in conjunction with a genetic algorithm in FIBS of metallic copper and show that this approach can increase the efficacy of filament-induced breakdown signal production. Through wavefront optimization, we enhance the intensity of a chosen characteristic spectroscopic feature of copper by a factor of approximately 3 when performing filamentation over a 1-meter distance. The relative standard deviation of signal intensity is reduced from ~17% to ~12% after optimization. We find that modification of the wavefront by introduction of astigmatism and coma maximizes the signal intensity, and these aberrations appear in two distinct trials of the genetic algorithm. We compare these findings to previous work on multiple filament control and discuss the possible mechanisms that lead to signal enhancement associated with both the beam amplitude and phase profile. A broader use of wavefront control with feedback may improve the performance of FIBS in remote sensing applications.

42 ENGINEERING↗

Optical and X-ray GRB Fundamental Planes as cosmological distance indicators

ABSTRACT Gamma-ray bursts (GRBs), can be employed as standardized candles, extending the distance ladder beyond Type Ia supernovae (SNe Ia, z = 2.26). We standardize GRBs using the three-dimensional (3D) Fundamental Plane relation (the Dainotti relation) among the rest-frame end time of the X-ray plateau emission, its corresponding luminosity, and the peak prompt luminosity. Combining SNe Ia and GRBs, we constrain ΩM = 0.299 ± 0.009 assuming a flat Λ cold dark matter (ΛCDM) cosmology with and without correcting GRBs for selection biases and redshift evolution. Using a 3D optical Dainotti correlation, we find this sample is as efficacious in the determination of ΩM as the X-ray sample. We trimmed our GRB samples to achieve tighter planes to simulate additional GRBs. We determined how many GRBs are needed as stand-alone probes to achieve a comparable precision on ΩM to the one obtained by SNe Ia only. We reach the same error measurements derived using SNe Ia in 2011 and 2014 with 142 and 284 simulated optical GRBs, respectively, considering the error bars on the variables halved. These error limits will be reached in 2038 and in 2047, respectively. Using a doubled sample (obtained by future machine learning approaches allowing a light-curve reconstruction and the estimates of GRB redshifts when z is unknown) compared to the current sample, with error bars halved we will reach the same precision as SNe Ia in 2011 and 2014, now and in 2026, respectively. If we consider the current SNe precision, this will be reached with 390 optical GRBs by 2054.

Dainotti, M. G.↗

Seismic Signal Detection on International Monitoring System 3-Component Stations using PhaseNet

In this report we discuss training a deep learning seismic signal detection model on 3-component stations from the International Monitoring System (IMS) using the PhaseNet architecture. Using 14 years of associated signals from the International Data Centre’s (IDC) Late Event Bulletin (LEB), we auto-curated training data consisting of signal windows containing associated arrivals, and noise windows that contain no LEB-associated signals. We trained several models using different waveform window durations (30 seconds and 100 seconds), with and without bandpass filtering. We evaluated the effectiveness of our models using associated signals from the Unconstrained Global Event Bulletin (UGEB) and found that several of our models outperformed the signal detections from the IDC’s Selected Event List 3 (SEL3) arrival table. The SEL3 bulletin evaluated on the UGEB dataset with 100-second waveform windows registered a precision and recall of .15 and .48, respectively, versus .19 and .59 for our filtered-data model. For the 30-second waveform window dataset, the SEL3 bulletin achieved a precision and recall of .31 and .47, respectively, versus .32 and .60 for our filtered-data model. Finally, our models detected signals from all source-to-receiver distances, suggesting it is feasible to use a single PhaseNet model for the IMS network.

58 GEOSCIENCES↗

Efficient Probabilistic Prediction and Uncertainty Quantification of Tropical Cyclone–Driven Storm Tides and Inundation

Abstract This study proposes and assesses a methodology to obtain high-quality probabilistic predictions and uncertainty information of near-landfall tropical cyclone–driven (TC-driven) storm tide and inundation with limited time and resources. Forecasts of TC track, intensity, and size are perturbed according to quasi-random Korobov sequences of historical forecast errors with assumed Gaussian and uniform statistical distributions. These perturbations are run in an ensemble of hydrodynamic storm tide model simulations. The resulting set of maximum water surface elevations are dimensionality reduced using Karhunen–Loève expansions and then used as a training set to develop a polynomial chaos (PC) surrogate model from which global sensitivities and probabilistic predictions can be extracted. The maximum water surface elevation is extrapolated over dry points incorporating energy head loss with distance to properly train the surrogate for predicting inundation. We find that the surrogate constructed with third-order PCs using elastic net penalized regression with leave-one-out cross validation provides the most robust fit across training and test sets. Probabilistic predictions of maximum water surface elevation and inundation area by the surrogate model at 48-h lead time for three past U.S. landfalling hurricanes (Irma in 2017, Florence in 2018, and Laura in 2020) are found to be reliable when compared to best track hindcast simulation results, even when trained with as few as 19 samples. The maximum water surface elevation is most sensitive to perpendicular track-offset errors for all three storms. Laura is also highly sensitive to storm size and has the least reliable prediction. Significance Statement The purpose of this study is to develop and evaluate a methodology that can be used to provide high-quality probabilistic predictions of hurricane-induced storm tide and inundation with limited time and resources. This is important for emergency management purposes during or after the landfall of hurricanes. Our results show that sampling forecast errors using quasi-random sequences combined with machine learning techniques that fit polynomial functions to the data are well suited to this task. The polynomial functions also have the benefit of producing exact sensitivity indices of storm tide and inundation to the forecasted hurricane properties such as path, intensity, and size, which can be used for uncertainty estimation. The code implementing the presented methodology is publicly available on GitHub.

54 ENVIRONMENTAL SCIENCES↗

Dynamic formation of preferentially lattice oriented, self trapped hydrogen clusters

Abstract A series of MD and DFT simulations were performed to investigate hydrogen self-clustering and retention in tungsten. Using a newly develop machine learned interatomic potential, spontaneous formation of hydrogen platelets was observed after implanting low-energy hydrogen into tungsten at high fluxes and temperatures. The platelets formed along low miller index orientations and neighboring tetrahedral and octahedral sites and could grow to over 50 atoms in size. High temperatures above 600 K and high hydrogen concentrations were needed to observe significant platelet formation. A critical platelet size of six hydrogen atoms was needed for long term stability. Platelets smaller than this were found to be thermally unstable within a few nanoseconds. To verify these observations, characteristic platelets from the MD simulations were simulated using large-scale DFT. DFT corroborated the MD results in that large platelets were also found to be dynamically stable for five or more hydrogen atoms. The LDOS from the DFT simulated platelets indicated that hydrogen atoms, particularly at the periphery of the platelet, were found to be at least as stable as hydrogen atoms in bulk tungsten. In addition, electrons were found to be localized around hydrogen atoms in the platelet itself and that hydrogen atoms up to 4.2 Å away within the platelet were found to share charge suggesting that the hydrogen atoms are interacting across longer distances than previously suggested. These results reveal a self-clustering mechanisms for hydrogen within tungsten in the absence of radiation induced or microstructural defects that could be a precursor to blistering and potentially explain the experimentally observed high hydrogen retention particularly in the near surface region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Damage eXplorer (RDX): A Probabilistic Framework for Learning Changes From Bitemporal Images

Recent decade has witnessed major changes on the Earth, for example, deforestation, varying cropping and human settlement patterns, and crippling damages due to disasters. Accurate damage assessment caused by major natural and anthropogenic disasters is becoming critical due to increases in human and economic loss. This increase in loss of life and severe damages can be attributed to the growing population, as well as human migration to the disaster prone regions of the world. Rapid assessment of these changes and dissemination of accurate information is critical for creating an effective emergency response. Change detection using high-resolution satellite images is a primary tool in assessing damages, monitoring biomass and critical infrastructures, and identifying new settlements. In this demo, we present a novel supervised probabilistic framework for identifying changes using very high-resolution multispectral, and bitemporal remote sensing images. Our demo shows that the rapid damage explorer (RDX) system is resilient to registration errors and differing sensor characteristics.

Change detection↗

PRIMO – The Oil & Gas Well Plugging Optimizer

This work presents PRIMO’s main capabilities and introduces the PRIMO web application, an intuitive user interface that leverages our sophisticated mathematical optimization model to rigorously optimize P&A priorities and plugging campaign efficiency. The web app simplifies user interaction, provides a powerful data management framework, and supports a broad user base (e.g., state agencies, well owners/operators, and plugging companies) to use PRIMO for decision-making. Specifically, we provide a demonstration of how to input the information on candidate wells, plugging campaign budget, user-defined priority and efficiency criteria to PRIMO. A real-world case study that consists of 1411 oil and gas wells and impact and efficiency priorities (e.g., well age, well proximity to schools/hospitals, well accessibility, distance between wells in projects) is presented to showcase PRIMO’s core capabilities: (i) ranking a candidate well population based on priorities, (ii) recommending high-impact and high-efficiency P&A projects, and (iii) assigning impact and efficiency scores to projects allowing for rigorous quantitative comparison among them.

02 PETROLEUM↗

Sound at Scale: Characterizing Impacts of Noise Ordinances on the Onshore Wind Energy Technical Potential for the United States

Recent surveys have documented the rapid rise of sound ordinances across state and county jurisdictions, which has become crucial for wind energy siting. However, the lack of information on ordinances and computational challenges in turbine sound modeling create uncertainties regarding how evolving policies may affect resource potential and clean energy objectives. Therefore, we develop an approach to evaluate wind turbine sound profiles at millions of locations across the U.S. and translate them into setback distances for every residential structure. Compared to a baseline reference scenario, we find a 7% reduction in the national wind energy capacity potential when accounting for counties with existing sound ordinances. Additionally, when expanding the surveyed sound ordinances nationwide, we observe a potential loss of 53% of the national wind capacity under the most stringent ordinances, with a disproportionate share of this lost capacity coming from high-quality and low-cost wind resource. This work reveals that neglecting sound ordinances results in a significant overestimation of wind resource potential and highlights the important trade-offs between increased wind energy deployment to meet target decarbonization goals and the social/environmental impacts of this deployment that must be considered.

aeroacoustics↗

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-04: Cherenkov Imaging for Radiation Therapy Dose Verification On Patients

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗