Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Smart pixel sensors Towards on-sensor filtering of pixel clusters with deep learning

High granularity silicon pixel sensors are at the heart of energy frontier particle physics collider experiments. At an collision rate of 40\,MHz, these detectors create massive amounts of data. Signal processing that handles data incoming at those rate and intelligently reduces the data within the pixelated region of the detector \textit{at rate} will enhance physics performance and enable physics analyses that are not currently possible. Using the shape of charge clusters deposited in an array of small pixels, the physical properties of the traversing particle can be extracted with locally customized neural networks. In this first work, we present a neural network that can be embedded into the on-sensor readout and filter out hits from low momentum tracks, reducing the detector's data volume by 54.4-75.4\%. The network is designed and simulated as a custom readout integrated circuit with 28\,nm CMOS technology and is expected to operate at less than 300\,$\mu W$ with an area of less than 0.2\,mm$^2$.

43 PARTICLE ACCELERATORS↗

Recycling Measurements for the Lithium Tokamak Experiment

The lithium tokamak experiment (LTX) is a spherical torus designed to investigate a low-recycling wall regime for magnetically confined plasmas. Traditional measurements of recycling using Dα emission are not feasible in LTX due to reflections off the plasma-facing-components: stainless-steel shell, liquid lithium layer, and molybdenum limiters. Since lithium has low VUV reflectivity, LTX will use Lyman-α emission to measure particle recycling. LTX will use 10- and 20-channel AXUV diode arrays with Lyman-α filters to view recycling off the inboard and outboard shells. A single detector views recycling off a limiter. Measurements will be used with neutral modeling to calculate recycling and neutral deposition. To investigate the performance of an AXUV diode with directly-deposited filter, measurements were obtained with this detector and a visible detector viewing a calibration plasma then compared with emission calculated using a collisional-radiative model.

Physics - Plasma physics↗

Smart pixel sensors: towards on-sensor filtering of pixel clusters with deep learning

Highly granular pixel detectors allow for increasingly precise measurements of charged particle tracks. Next-generation detectors require that pixel sizes will be further reduced, leading to unprecedented data rates exceeding those foreseen at the High- Luminosity Large Hadron Collider. Signal processing that handles data incoming at a rate of $\mathcal{O}$(40 MHz) and intelligently reduces the data within the pixelated region of the detector at rate will enhance physics performance at high luminosity and enable physics analyses that are not currently possible. Using the shape of charge clusters deposited in an array of small pixels, the physical properties of the traversing particle can be extracted with locally customized neural networks. In this first demonstration, we present a neural network that can be embedded into the on-sensor readout and filter out hits from low momentum tracks, reducing the detector's data volume by 57.1%–75.7%. The network is designed and simulated as a custom readout integrated circuit with 28 nm CMOS technology and is expected to operate at less than 300 μW with an area of less than 0.2 mm 2 . The temporal development of charge clusters is investigated to demonstrate possible future performance gains, and there is also a discussion of future algorithmic and technological improvements that could enhance efficiency, data reduction, and power per area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton rings from late-forming ballistic sheath fields

Many laser-driven ion experiments have seen ring-like patterns in the proton angular distribution across a wide array of laser and target parameters. These rings can impede measurement due to the small acceptance angle of detectors and often inhibit potential applications. A myriad of explanations for their formation have been proposed, yet most studies attribute them to some aspect of the laser–plasma interaction. Using 3D particle-in-cell simulations, we show that late-forming strong radial electric fields can arise due to charge separation while the beam is in flight, long after the laser–plasma interaction. These fields can accelerate ions to significant divergences (≈ 10°) as they propagate away from the target. We compare our results to a recent experiment where a high intensity, short pulse laser (I 0 ≈ 10 21 W/cm 2 , τ ≈ 30 fs) was incident upon thin (≈ 1 μm) liquid crystal targets. Our simulations capture all the main features of the experimental results—namely, robust ring formation and larger rings for higher energy protons. In addition, we show that rings do not form for sufficiently short preplasma scale lengths. Finally, we develop a phenomenological model to describe the spatiotemporal structure of the radial electric field and use this to explain the proton rings' energy and preplasma dependencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long-term calibration and validation of stability of the Auger Engineering Radio Array using the diffuse Galactic radio emission

The Auger Engineering Radio Array (AERA) measures radio emission from high-energy extensive air showers. Consisting of 153 autonomous radio-detector stations spread over 17 km^2, it detects radio waves in the frequency range of 30 to 80 MHz. Accurate characterization of the detector response is crucial for proper interpretation of the collected data. Previously, this was achieved through laboratory measurements of the analog chain and simulations and measurements of the antenna's directional response. In this paper, we perform an absolute calibration using the continuously monitored sidereal modulation of the diffuse Galactic radio emission. Calibration is done by comparing the average frequency spectra recorded by the stations with predictions from seven different models of the full radio sky, accounting for the system response, which includes the antenna, filters, and amplifiers. The analysis of the calibration constants over a period of seven years shows no relevant and no significant ageing effect in the AERA antennas. This result confirms the long-term stability of the detector stations and demonstrates the possibility for a radio detector to effectively monitor ageing effects of other detectors operating over extended periods.

Antennas↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

Late Prompt Fission Gamma Rays from 235 U(n,f) and 252 Cf(sf)

Two measurements of fission γ rays were performed with the DANCE and NEUANCE arrays using the reactions 235 U(n, f) and 252 Cf(sf). Utilizing the fast time response of the detectors and a method for estimating the accidental background, we obtained the energy spectrum of the late prompt fission γ rays as a function of the time since fission. The experimental results are compared with predictions of the code CGMF folded with GEANT4 simulations of the detector response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

wa-hls4ml: A GNN Surrogate Model for hls4ml

Recent advancements in use of machine learning techniques on field-programmable gate arrays (FPGAs) have allowed for implementation of embedded neural networks with extremely low latency. This is invaluable for particle detectors at the Large Hadron Collider, where latency and used area must be strictly bounded. The hls4ml framework is a procedure for converting from trained machine learning model software, to a synthesis result that can be used on an FPGA. However, running the pipeline is a time-consuming procedure, and there is a strong risk of failure. In particular, it is possible that the model is unable to be converted into a synthesis result, or that the resource consumption of the model will exceed the resources of the target FPGA. To aid with this development, we introduce wa-hls4ml, a surrogate model which uses a graph neural network to emulate the structure of the source models. The goal is to estimate the chance of success and resource consumption of an arbitrary model when passed through the hls4ml procedure, without the time consumption of actually running the pipeline.

43 PARTICLE ACCELERATORS↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Measuring Light Yield with Isolated Protons in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are precision detectors used extensively in neutrino physics. The MicroBooNE experiment at Fermilab is one of the experiments employing this technique and has collected 5 years of data from 2015-2021. The primary signal in LArTPCs is ionisation, but argon also emits large quantities of scintillation light, which can be used for calorimetry, timing and background rejection. Prompt scintillation light in MicroBooNE is recorded with an array of 32 PhotoMultiplier Tubes (PMTs). To enable the full use of scintillation light in the experiment, it is important to characterize the efficiency of light collection in the detector, i.e. the light yield. We present a new method of measuring the light yield using isolated proton interactions, which enables a position-dependent light yield measurement to map the response of the detector across its volume. This method can be used to calibrate the light response in large-scale LArTPC detectors as well as to test assumptions used in simulating scintillation light.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗