Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An Imaging Interferometer for Terrestrial Remote Sensing

A prototype imaging interferometer called DASI (digital array scanned interferometer) is under development at our laboratories. Our objective is to design an instrument for remote sensing of Earth's atmosphere and surface. This paper describes the unusual characteristics of DASIs which make them promising candidates for ground and aircraft-based terrestrial measurements. These characteristics include superior signal-to-noise, design simplicity and compactness, relative to dispersion based imaging spectrometers. Perhaps one of the most notable features of DASIs is their ability to acquire an entire interferogram simultaneously without any moving optical elements. We also describe selected laboratory and ground based field measurements using the prototype DASI. A CCD detector array was placed at the DASI detector plane for wavelength coverage from 0.4 to 1.0 micron. A NICMOS MCT detector was used for coverage from 1.1 to 2.2 micron. The DASI was configured to have a spectral resolution of about 300 1/cm, a spatial field of view of 5 degrees, and a constant number of transverse spatial elements (detector dependent) for each exposure frame. Frame exposure rates were up to 0.6 Hz with the potential to achieve 5 Hz. Image cube measurements of laboratory targets and terrestrial scenes were obtained by multiple frame scanning over the field of view. These data sets reveal the potential science yields from obtaining simultaneous high resolution spatial and spectral information.

Hammer, Philip D.↗

Design and Deployment of a Multichroic Polarimeter Array on the Atacama Cosmology Telescope

We present the design and the preliminary on-sky performance with respect to beams and pass bands of a multichroic polarimeter array covering the 90 and 146 GHz cosmic microwave background bands and its enabling broad-band optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array deployed for a CMB experiment and paves the way for the extensive use of multichroic detectors and broad-band optical systems in the next generation of CMB experiments.

passbands↗

SAFIRE: A Far-Infrared Imaging Spectrometer for SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 micrometers-655 micrometers with spectral resolving power of approx. 1500 (200km/s). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background-limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors. An engineering prototype of SAFIRE with a small but cutting edge detector array will be available for use during the initial SOFIA operations; further expansion to larger format arrays will be incorporated during SAFIRE's lifetime.

Shafer, Richard A.↗

An Imaging Laser Altimeter for Lunar Scientific Exploration

A new approach to laser altimetry is offered by the development of micro-lasers and pixilated detectors that enable very high resolution measurement of topography and relatively wide swath observations. An imaging altimeter with a 8x8 array detector working at a probability of less than a single photon/shot could map the Moon or similar sized body in approximately 2 years and provide 5 meter horizontal resolution topography and a 10 centimeter vertical accuracy. In addition, it would provide surface roughness and surface slopes on similar length scales of 5 meters and be able to address a range of problems for which topography or lunar shape is important at the decimeter level. This includes the topography of the polar regions, where ice is thought to have been identified, and also the cratering history of the Moon which could be assessed with a dataset of uniform quality and high resolution.

Source record↗

An Imaging Laser Altimeter for Lunar Scientific Exploration

A new approach to laser altimetry is offered by the development of micro-lasers and pixilated detectors that enable very high resolution measurement of topography and relatively wide swath observations. An imaging altimeter with a 8x8 array detector working at a probability of less than a single photon/shot could map the Moon or similar sized body in approximately 2 years and provide 5 meter horizontal resolution topography and a 10 centimeter vertical accuracy. In addition, it would provide surface roughness and surface slopes on similar length scales of 5 meters and be able to address a range of problems for which topography or lunar shape is important at the decimeter level. This includes the topography of the polar regions, where ice is thought to have been identified, and also the cratering history of the Moon which could be assessed with a dataset of uniform quality and high resolution.

Smith, David E.↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments in infrared multispectral mapping of earth resources

Two evolutionary infrared remote sensing experiments provide the basis for the development of an operational mapping capability for geology exploration. A 10-band radiometer scheduled for an early Shuttle flight has completed an aircraft flight program which demonstrated the utility of a number of narrow spectral channels. A multispectral mapper utilizing an infrared area array detector to acquire simultaneous images in multiple wavelengths is being assembled. A design concept for an operational sensor which employs area arrays for registered multispectral image data acquisition is under study. The sensor would utilize onboard spectral band selection, radiometric correction, and data compression to satisfy the demanding requirements of the user community.

Wellman, J. B.↗

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

Astronomical application of IR CID technology

A portable microcomputer data system was developed to test a 2 x 64-element Si:Bi charge injection device (CID) infrared detector array on the Lick Observatory Shane telescope. An existing 0.5 m spectrograph was used for the tests after modification, and a spectral resolution of 1000 was achieved. Slow device response, due to the low background conditions in the spectrograph were shown. Astronomical data were later obtained, and a device read noise on the order of a few hundred electrons was achieved. The signal to noise ratios of the resulting spectra were about a factor of five lower than what could have been achieved with discrete photoconductive detectors. It is concluded that the CID array is competitive for applications in backgrounds lower than those used in the tests.

Rank, D. M.↗

Getting NuSTAR on Target: Predicting Mast Motion

The Nuclear Spectroscopic Telescope Array (NuSTAR) is the first focusing high energy (3-79 keV) X-ray observatory operating for four years from low Earth orbit. The X-ray detector arrays are located on the spacecraft bus with the optics modules mounted on a flexible mast of 10.14m length. The motion of the telescope optical axis on the detectors during each observation is measured by a laser metrology system and matches the pre-launch predictions of the thermal flexing of the mast as the spacecraft enters and exits the Earths shadow each orbit. However, an additional motion of the telescope field of view was discovered during observatory commissioning that is associated with the spacecraft attitude control system and an additional flexing of the mast correlated with the Solar aspect angle for the observation. We present the methodology developed to predict where any particular target coordinate will fall on the NuSTAR detectors based on the Solar aspect angle at the scheduled time of an observation. This may be applicable to future observatories that employ optics deployed on extendable masts. The automation of the prediction system has greatly improved observatory operations efficiency and the reliability of observation planning.

NASA small explorer↗

Cassini CIRS Observations of Iapetus' Thermal Emission

Cassini s Composite Infrared Spectrometer (CIRS, [1]) mapped Iapetus thermal emission from 7 to approx.300 microns during the spacecraft s December 31st 2004 flyby of the satellite. Short-wavelength spectra were obtained with the CIRS "FP3" (10 - 17 micron) and "FP4" (7 - 10 micron) detector arrays, each consisting of 1 x 10 pixels with a spatial resolution of 0.29 milliradians, while longer wavelength observations used the "FP1" detector, with a single-aperture detector with 4 milliradian diameter. The detectors are scanned across the target to build up an image cube with two spatial dimensions and one spectral dimension. CIRS daytime observations covered the dark terrain of Cassini Regio, except for high northern latitudes which were occupied by bright terrain, while nighttime observations covered a mixture of bright and dark terrain. The 120,000 km flyby distance provided a maximum spatial resolution of 35 km in the FP3 and FP4 detectors, and 500 km in the FP1 detector.

Spencer, J. R.↗

Observations of a gamma-ray burst and other sources with a large-area, balloon-borne detector

Observations of a weak cosmic gamma ray burst of integrated intensity 2 x 10 to the -6th erg/sq cm, two solar flare events, and pulsed emission profiles of A0535+26 and NP0532 are reported for several energy intervals in the energy range from 45 to 520 keV. The measurements were made with a NaI(Tl) detector array flown on a balloon to 4 g/sq cm residual atmosphere from Palestine, Texas, on October 6-8, 1980, for 28 hours. The detector is a prototype of the Burst and Transient Source Experiment (BATSE) to be flown on the Gamma-Ray Observatory (GRO).

Wilson, R. B.↗

Development of a large pixel, spectrally optimized, pinned photodiode/interline charge coupled device (CCD) detector for the Earth Observing System (EOS)/Moderate-Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument

A pinned photodiode/interline CCD Detector Array is under development for the EOS/MODIS-T project. Outstanding features of the device include large pixels, spectrally optimized fill factors, and blooming protection. The detector has 30 spatial rows and 32 spectral columns. The device layout is split into two halves; each half has its own detector area, storage area, and output structure.

Ewin, Audrey J.↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Status of the Micro-X Sounding Rocket X-Ray Spectrometer

Micro-X is a sounding rocket borne X-ray telescope that utilizes transition edge sensors to perform imaging spectroscopy with a high level of energy resolution. Its 2.1m focal length X-ray optic has an effective area of 300 sq cm, a field of view of 11.8 arcmin, and a bandpass of 0.12.5 keV. The detector array has 128 pixels and an intrinsic energy resolution of 4.5 eV FWHM. The integration of the system has progressed with functional tests of the detectors and electronics complete, and performance characterization of the detectors is underway. We present an update of ongoing progress in preparation for the upcoming launch of the instrument.

X-ray astronomy↗

Photovoltaic quantum well infrared photodetectors

Quantum well infrared photodetectors (QWIP) are a promising new approach to long-wavelength infrared detector arrays. Both single-well photovoltaic and multiple-well photoconductive devices have been demonstrated. The author discusses noise considerations as they apply to photovoltaic devices, grating coupling of the infrared light into QWIPs, and recently demonstrated electrically tunable detectors. The use of light trapping to enhance the quantum efficiency and reduce cross-talk in an array is addressed.

Lyon, Steve A.↗

Fiber-coupled high resolution infrared array spectrometer for the Kuiper Airborne Observatory

A novel cryogenic grating spectrometer (FCAS) is being designed for observations of volatiles in cometary and planetary atmospheres, and in newly forming planetary systems. The instrument features two-dimensional detector arrays coupled to a high-dispersion echelle by infrared fibers, and will achieve a spectral resolving power of about 40,000. The primary observational platform for this instrument will be the Kuiper Airborne Observatory, but it will also be configured for use at ground-based observatories. Initially, the spectrometer will use a 58 x 62, 1- to 5-micron InSb array. Larger-format IR arrays and arrays of different composition, will later be incorporated as they become available. The instrument will be used in two modes. The first uses a large format IR array in the spectral image plane for the customary one-dimensional spectral-one-dimensional spatial coverage. In the second mode, a massive, coherent bundle of infrared transmitting ZrF4 fibers will be installed after the dispersive element, to reformat the two-dimensional array into an elongated one-dimensional array for wide spectral coverage, allowing multiple lines to be measured in a single integration with high sensitivity. The overall instrument design is discussed, and the system sensitivity is estimated.

Glenar, D. A.↗