Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detect And Avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Lightweight TiC–(Fe–Al) ceramic–metal composites made in situ by pressureless melt infiltration

Lightweight ceramic–metal (cermet) composites combine stiffness and hardness with fracture toughness and ductility. TiC and Al are ideal pairs among lightweight cermet composites because of their relatively high strength-to-weight ratios, but these materials are difficult to process in solid state or with Al melt infiltration without making an aluminum carbide phase, which is detrimental to mechanical properties. Here, Fe is added to a TiC powder preform to reduce the activity of Al with TiC during Al melt infiltration and to aid in pressing TiC preforms, making a lightweight TiC–(Fe–Al) composite while avoiding other, unwanted phases. The composites are made by first pressing TiC powder mixed with Fe followed by Al melt infiltration; the result is a composite with high TiC content in a two-phase matrix, both of which are Fe–Al-based. The composite has low density, low porosity, high hardness, no detectable Al 4 C 3 phase with X-ray diffraction and retains shape well during infiltration.

36 MATERIALS SCIENCE↗

Fast broad-band photon detector based on quantum well devices and charge-integrating electronics for non-invasive FEL monitoring

The recent evolution of free-electron lasers has not been matched by the development of adequate beam-monitoring instrumentation. However, for both experimental and diagnostics purposes, it is crucial to keep such photon beams under control, avoiding at the same time the absorption of the beam and the possible destruction of the detector. These requirements can be fulfilled by utilizing fast and non-invasive photon detectors operated in situ, upstream from the experimental station. From this perspective, sensors based on Quantum Well (QW) devices can be the key to detecting ultra-short light pulses. In fact, owing to their high electron mobility, InGaAs/InAlAs QW devices operated at room temperature exhibit sub-nanosecond response times. Their direct, low-energy band gap renders them capable of detecting photons ranging from visible to X-ray. Furthermore, the 2D electron gas forming inside the QW is responsible for a charge amplification mechanism, which increases the charge collection efficiency of these devices. In order to acquire the signals produced by these QW sensors, a novel readout electronics has been developed. It is based on a high-speed charge integrator, which allows short, low-intensity current pulses to be read within a 50-ns window. The integrated signal is acquired through an ADC and the entire process can be performed at a 10-MHz repetition rate. This work provides a detailed description of the development of the QW detectors and the acquisition electronics, as well as reporting the main experimental results, which show how these tools are well suited for the realization of fast, broad-band beam monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics-Based Machine Learning Methods for U-235 Forensics Signatures

Signatures of low-intensity U-235 sources have been recently studied by utilizing a variety of machine learning (ML) classifiers using features derived from gamma spectral measurements collected under structured campaigns. Several ML classifiers, such as ensemble of tress and classification trees, revealed misleadingly-optimistic training error due to over-fitting, and furthermore, their performance is not directly relatable to the physical properties due to their data-driven, opaque designs. We present a regression-based ML method that first estimates the inverse distance to the source and then utilizes a threshold to infer its presence, by representing the background as a source located at an infinite distance. For the inverse distance estimation, we study the ensemble of trees and Gaussian process regression methods, and a hyper parameter auto-tuning and selection method that employs five regression estimators. These methods avoid the over-fitting observed in several ML classifiers, while providing the classification error nearly comparable to them based on independent test data. Their error is directly related to estimates of the inverse physical distance to source, and the precision of error determines the seperability property that determines the false alarm and missed detection rates. The property of monotonic decrease of the source strength with increasing detector distance combined with Poisson distribution of measurements is utilized to analytically validate these methods by deriving the generalization equations of underlying regression methods.

Rao, Nageswara↗

Triton: Igiugig Fish Video Analysis (Project Report)

This document summarizes the analysis of video data collected around the Ocean Renewable Power Company’s RivGen® device in the Kvichak River during July and August 2015. Human (manual) analysis of the data was undertaken and used to develop automated algorithms to detect fish in the frames and describe interaction behavior. In addition, a web application, EyeSea, was developed to combine manual and automated processing, so that ultimately the automated algorithms could be used to identify where human analysis was needed (i.e., when fish are present in video frames). The aim of the project was to develop algorithms that could identify video frames with fish present that could then be used to enable faster manual analysis. However, the project has also identified recommendations for future data collection, and research that could help analysis and interpretation. The manual analysis started to look at all data from the start of the deployment; this was to ensure rare events were seen, and initially focused on night-time data when more fish were present. This process highlighted the amount of time taken to identify fish, and ultimately only 42.33 hours of video were reviewed due to the time-consuming analysis. The data were classified as ‘Fish’, when the reviewer was confident it was a fish, and ‘Maybe’ fish, when it was difficult to distinguish. This was based on the movement, shape and color characteristics. ‘Fish’ were further classified as ‘adult’, ‘juvenile’, or ‘unidentifiable’. Behavioral attributes were noted, which were broadly divided into passive and avoidance activities. In over 42 hours data, there were only 20 potential contact interactions, of which 3 were ‘Maybe’ classifications, 12 were juveniles and 5 were adults; on only one occasion was an actual contact confirmed, and this was an adult fish with the camera, not the turbine itself. This also highlights the difficulties associated with confirming a strike or collision event as occurring or being a near-miss. More interactions were detected at night; this was probably biased by nighttime artificial light use, which may have attracted fish, but also could have increased detection probability as the light is reflected from the fish itself. For the algorithm development, background subtraction, optical flow, and deep learning techniques were considered. The deep learning approach was determined as needing too much training data for this application, and therefore was not continued. The optical flow analysis was considered promising, but did not give immediate results, so would need further investigation. Therefore, background subtraction was the main focus. Three methods of background subtraction were tried: Robust Principal Components Analysis (RPCA), Gaussian Mixture Model (GMM) and Video Background Extraction(ViBE). A classification technique was then applied to the foreground images to determine fish presence. Using this combination, it was found that fish could be accurately detected when occupying more pixels (>200 pixels, 98.2% correct; 100-200 pixels, 99.6% correct; 5-100 pixels, 85.4% correct; 2-5 pixels, 66.3% correct). In parallel, EyeSea was developed to convert the video data to a usable form and to enable manual and automated analysis of the data that would have a standardized output. Recommendations for further research, and standardized methods for data collection are given.

13 HYDRO ENERGY↗

Detection of Anomalous Gamma-Ray Spectra for On-Site Inspection

This work aims to solve some of the technical and logistical challenges inherent in performing On Site Inspection activities under the authority of the Comprehensive Nuclear-Test-Ban Treaty. Inspectors require equipment that can reliably identify the radionuclide signatures of nuclear test explosions amid a background of environmental contamination. Detection of these radiation anomalies by mobile search teams in the air or on the ground can narrow the search field and target specific areas for more detailed inspection or sampling. The need to protect confidential information of the inspected State Party, especially regarding past nuclear testing activities, suggests that full access to measured gamma-ray spectra should be limited. Spectral blinding techniques---in which only a fraction of the information derived from the spectra is displayed and stored---have the potential to meet the needs of both the OSI team and the State Party. In this paper, we describe one such algorithm that we have developed for identifying anomalous spectra from handheld, mobile, or aerial sensors. The algorithm avoids potential sensitivities by reducing the gamma-ray spectrum into a single number that is displayed and stored. A high value indicates that the spectrum is anomalous. The proposed technique does not rely on identifying specific radionuclides, operates well in the presence of high background variability, and can be configured to ignore specific spectral components. In previous work, the algorithm has proven very effective in classifying gamma-ray spectra as anomalous or not, even with poor statistical information. We performed a limited simulation of an airborne search scenario to demonstrate the potential algorithm for OSI missions. The technique successfully detected an injected source of interest whose count rate was an order of magnitude below background levels. We also configured the algorithm to ignore 137Cs as irrelevant to the mission. The resulting alarm metrics were unaffected by the presence of injected 137Cs contamination.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Remotely Sensed Datasets to Detect Changes in Waste Sites

This work evaluated various indirect remote techniques for detecting surficial changes and structural land deformation at the Hanford site. Given the partial collapse of the PUREX tunnel, and possible surface subsidence at other burial sites containing radioactive waste and contaminated equipment, timely alert and knowledge related to land surface elevation changes has emerged as a management priority. Findings of this study suggests that space borne RADAR and multispectral based-analysis would be of significant value in detecting changes in surficial and structural land features that may be otherwise undetectable or unnoticed from field observations alone. A continuous, and potentially semi-automated, monitoring program would add critical insight to recovering from, and predicting episodic type events, such as the tunnel collapse. Furthermore, an indirect approach ultimately saves resources and time, and avoids unnecessary risk associated with ground-based monitoring. Various options for supporting such an effort are described in the final section of this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probing the Intergalactic Medium with Ly α and 21 cm Fluctuations

We study 21 cm and Ly α fluctuations, as well as H α , while distinguishing between Ly α emission of galactic, diffuse, and scattered intergalactic medium (IGM) origin. Cross-correlation information about the state of the IGM is obtained, testing neutral versus ionized medium cases with different tracers in a seminumerical simulation setup. In order to pave the way toward constraints on reionization history and modeling beyond power spectrum information, we explore parameter dependencies of the cross-power signal between 21 cm and Ly α , which displays a characteristic morphology and a turnover from negative to positive correlation at scales of a couple Mpc{sup −1}. In a proof of concept for the extraction of further information on the state of the IGM using different tracers, we demonstrate the use of the 21 cm and H α cross-correlation signal to determine the relative strength of galactic and IGM emission in Ly α . We conclude by showing the detectability of the 21 cm and Ly α cross-correlation signal over more than one decade in scale at high signal-to-noise ratio for upcoming probes like SKA and the proposed all-sky intensity mapping satellites SPHEREx and CDIM, while also including the Ly α damping tail and 21 cm foreground avoidance in the modeling.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine-learning identification of the variability of mean velocity and turbulence intensity for wakes generated by onshore wind turbines: Cluster analysis of wind LiDAR measurements

Light detection and ranging (LiDAR) measurements of isolated wakes generated by wind turbines installed at an onshore wind farm are leveraged to characterize the variability of the wake mean velocity and turbulence intensity during typical operations, which encompass a breadth of atmospheric stability regimes and rotor thrust coefficients. The LiDAR measurements are clustered through the k-means algorithm, which enables identifying the most representative realizations of wind turbine wakes while avoiding the imposition of thresholds for the various wind and turbine parameters. Considering the large number of LiDAR samples collected to probe the wake velocity field, the dimensionality of the experimental dataset is reduced by projecting the LiDAR data on an intelligently truncated basis obtained with the proper orthogonal decomposition (POD). The coefficients of only five physics-informed POD modes are then injected in the k-means algorithm for clustering the LiDAR dataset. The analysis of the clustered LiDAR data and the associated supervisory control and data acquisition and meteorological data enables the study of the variability of the wake velocity deficit, wake extent, and wake-added turbulence intensity for different thrust coefficients of the turbine rotor and regimes of atmospheric stability. Furthermore, the cluster analysis of the LiDAR data allows for the identification of systematic off-design operations with a certain yaw misalignment of the turbine rotor with the mean wind direction.

17 WIND ENERGY↗

VERSION 1 OF THE HUBBLE SOURCE CATALOG

The Hubble Source Catalog is designed to help optimize science from the Hubble Space Telescope (HST) by combining the tens of thousands of visit-based source lists in the Hubble Legacy Archive (HLA) into a single master catalog. Version 1 of the Hubble Source Catalog includes WFPC2, ACS/WFC, WFC3/UVIS, and WFC3/IR photometric data generated using SExtractor software to produce the individual source lists. The catalog includes roughly 80 million detections of 30 million objects involving 112 different detector/filter combinations, and about 160,000 HST exposures. Source lists from Data Release 8 of the HLA are matched using an algorithm developed by Budavári and Lubow. The mean photometric accuracy for the catalog as a whole is better than 0.10 mag, with relative accuracy as good as 0.02 mag in certain circumstances (e.g., bright isolated stars). The relative astrometric residuals are typically within 10 mas, with a value for the mode (i.e., most common value) of 2.3 mas. The absolute astrometric accuracy is better than 0{sup ″} .1 for most sources, but can be much larger for a fraction of fields that could not be matched to the PanSTARRS, SDSS, or 2MASS reference systems. In this paper we describe the database design with emphasis on those aspects that enable the users to fully exploit the catalog while avoiding common misunderstandings and potential pitfalls. We provide usage examples to illustrate some of the science capabilities and data quality characteristics, and briefly discuss plans for future improvements to the Hubble Source Catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic cache bypassing

A processing system fills a memory access request for data from a processor core by bypassing a cache when a write congestion condition is detected, and when transferring the data to the cache would cause eviction of a dirty cache line. The cache is bypassed by transferring the requested data to the processor core or to a different cache. Accordingly, the processing system can temporarily bypass the cache storing the dirty cache line when filling a memory access request, thereby avoiding the eviction and write back to main memory of a dirty cache line when a write congestion condition exists.

97 MATHEMATICS AND COMPUTING↗

AN observational detection of the bridge effect of void filaments

The bridge effect of void filaments is a phrase coined by Park and Lee to explain the correlations found in a numerical experiment between the luminosity of the void galaxies and the degree of straightness of their host filaments. Their numerical finding implies that a straight void filament provides a narrow channel for the efficient transportation of gas and matter particles from the surroundings into void galaxies. Analyzing the Sloan void catalog constructed by Pan et al., we identify the filamentary structures in void regions and determine the specific size of each void filament as a measure of its straightness. To avoid possible spurious signals caused by Malmquist bias, we consider only those void filaments whose redshifts are in the range 0⩽z⩽0.02 and find a clear tendency that the void galaxies located in the straighter filaments are on average more luminous, which is in qualitative agreement with the numerical prediction. It is also shown that the strength of correlation increases with the number of member galaxies in the void filaments, which can be understood physically on the grounds that the more stretched filaments can connect the dense surroundings even to galaxies located deep in the central parts of the voids. This observational evidence may provide a key clue to the puzzling issue of why the void galaxies have higher specific star formation rates and bluer colors than their wall counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inference of the optical depth to reionization τ from Planck CMB maps with convolutional neural networks

The optical depth to reionization, τ, is the least constrained parameter of the cosmological Λ cold dark matter (ΛCDM) model. To date, its most precise value is inferred from large-scale polarized cosmic microwave background (CMB) power spectra from the High Frequency Instrument (HFI) aboard the Planck satellite. These maps are known to contain significant contamination by residual non-Gaussian systematic effects, which are hard to model analytically. Therefore, robust constraints on τ are currently obtained through an empirical cross-spectrum likelihood built from simulations. In this paper, we present a likelihood-free inference of τ from polarized Planck HFI maps which, for the first time, is fully based on neural networks (NNs). NNs have the advantage of not requiring an analytical description of the data and can be trained on state-of-the-art simulations, combining the information from multiple channels. By using Gaussian sky simulations and Planck SRoll2 simulations, including CMB, noise, and residual instrumental systematic effects, we trained, tested, and validated NN models considering different setups. We inferred the value of τ directly from Stokes Q and U maps at ~4° pixel resolution, without computing angular power spectra. On Planck data, we obtained τ NN = 0.0579 ± 0.0082, which is compatible with current EE cross-spectrum results but with a ~30% larger uncertainty, which can be assigned to the inherent nonoptimality of our estimator and to the retraining procedure applied to avoid biases. While this paper does not improve on current cosmological constraints on τ, our analysis represents a first robust application of NN-based inference on real data, and highlights its potential as a promising tool for complementary analysis of near-future CMB experiments, also in view of the ongoing challenge to achieve the first detection of primordial gravitational waves.

79 ASTRONOMY AND ASTROPHYSICS↗

New PVLAS results and limits on magnetically induced optical rotation and ellipticity in vacuum

In 2006 the PVLAS collaboration reported the observation of an optical rotation generated in vacuum by a magnetic field. To further check against possible instrumental artifacts, several upgrades to the PVLAS apparatus have been made during the past year. Two data taking runs, at the wavelength of 1064 nm, have been performed in the new configuration with magnetic field strengths of 2.3 and 5 T. The 2.3 T field value was chosen in order to avoid stray fields. The new observations do not show the presence of a rotation signal down to the levels of 1.2x10{sup -8} rad at 5 T and 1.0x10{sup -8} rad at 2.3 T (at 95% C.L.) with 45 000 passes in the magnetic field zone. In the same conditions no ellipticity signal was detected down to 1.4x10{sup -8} at 2.3 T (at 95% C.L.), whereas at 5 T a signal is still present. The physical nature of this ellipticity as due to an effect depending on B{sup 2} can be excluded by the measurement at 2.3 T. These new results completely exclude the previously published magnetically induced vacuum dichroism results, indicating that they were instrumental artifacts. These new results therefore also exclude the particle interpretation of the previous PVLAS results as due to a spin-zero boson. The background ellipticity at 2.3 T can be used to determine a new limit on the total photon-photon scattering cross section of {sigma}{sub {gamma}}{sub {gamma}}<4.5x10{sup -34} barn at 95% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

An integrated lateral flow test strip with electrochemical sensor (LFTSES) device with rapid, selective and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of post-exposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with detection limit of 0.02 nM. Based on this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values, but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.

59 BASIC BIOLOGICAL SCIENCES↗

Estimating the density of states of frustrated spin systems

Abstract Estimating the density of states (DOS) of systems with rugged free energy landscapes is a notoriously difficult task of the utmost importance in many areas of physics ranging from spin glasses to biopolymers. DOS estimation has also recently become an indispensable tool for the benchmarking of quantum annealers when these function as samplers. Some of the standard approaches suffer from a spurious convergence of the estimates to metastable minima, and these cases are particularly hard to detect. Here, we introduce a sampling technique based on population annealing enhanced with a multi-histogram analysis and report on its performance for spin glasses. We demonstrate its ability to overcome the pitfalls of other entropic samplers, resulting in some cases in large scaling advantages that can lead to the uncovering of new physics. The new technique avoids some inherent difficulties in established approaches and can be applied to a wide range of systems without relevant tailoring requirements. Benchmarking of the studied techniques is facilitated by the introduction of several schemes that allow us to achieve exact counts of the degeneracies of the tested instances.

Barash, Lev (ORCID:000000022298785X)↗

Efficient Detection of Emission-line Galaxies in the Cl0016+1609 and MACSJ1621.4+3810 Supercluster Filaments Using SITELLE

We observe a system of filaments and clusters around Cl0016+1609 and MACSJ1621.4+3810 using the SITELLE Fourier transform spectrograph at the Canada–France–Hawaii Telescope. For Cl0016+1609 (z = 0.546), the observations span an 11.8 Mpc × 4.3 Mpc region along an eastern filament that covers the main cluster core, as well as two 4.3 Mpc × 4.3 Mpc regions that each cover southern subclumps. For MACSJ1621.4+3810 (z = 0.465), 3.9 Mpc × 3.9 Mpc around the main cluster core is covered. We present the frequency and location of the emission-line galaxies and their emission-line images, and calculate the star formation rates, specific star formation rates, and merger statistics. In Cl0016+1609, we find 13 [O ii] 3727 Å emitting galaxies with star formation rates between 0.2 and 14.0 M {sub ⊙} yr{sup −1}. Of these, 91{sub −10}{sup +3}% are found in regions with moderate local galaxy density, avoiding the dense cluster cores. These galaxies follow the main filament of the superstructure and are mostly blue and disky, with several showing close companions and merging morphologies. In MACSJ1621.4+3810, we find 10 emission-line sources. All are blue (100{sub −15}{sup +0}%), with 40{sub −12}{sup +16}% classified as disky and 60{sub −16}{sup +12}% as merging systems. Eight avoid the cluster core (80{sub −17}{sup +7}%), but two (20{sub −7}{sup +17}%) are found near high-density regions, including the brightest cluster galaxy (BCG). These observations push the spectroscopic study of galaxies in filaments beyond z ∼ 0.3 to z ∼ 0.5. Their efficient confirmation is paramount to their usefulness as more galaxy surveys come online.

47 OTHER INSTRUMENTATION↗

A comparison of pulsed and continuous lasers for high-temperature Raman measurements of anhydrite

Oxygen carrier particles (OCPs) serve as fuel oxidant in emerging chemical looping combustion systems. However, chemical looping combustion process optimization is hindered by the lack of online sensors for measurements of OCP oxidation states at temperatures up to 1,000 °C and pressures up to 10 atm. We are investigating Raman spectroscopy as a potential solution, as this technique is known for its ability to provide noninvasive, molecularly specific information in real time in a wide variety of applications. As a case study, Raman spectra from high–temperature (>1,000 °C) anhydrite, a potential OCP, are presented using pulsed and continuous wave excitation at 532 nm. When pulsed excitation is coupled with time–gated detection, background signal from thermal radiation can be significantly reduced from single pulse spectra, outperforming results using an ungated detector. Also, laser heating of the sample is not observed but laser–induced breakdown spectra increasingly appear with increasing temperature and pulse intensity. Compared with pulsed excitation, continuous wave excitation with longer acquisition time, offers higher signal to noise and avoids the risk for laser–induced breakdown spectra but demonstrates minor sample heating. Finally, the data demonstrate practical utility by (a) providing a calibration of anhydrite's ν 1 (1,017 cm –1 ) Raman temperature–dependent band position and by (b) providing estimates of temperature using the ratios of the Stokes/anti–Stokes ν 1 integrated intensities. Furthermore, these results demonstrate the first high–temperature, pulsed Raman spectra from anhydrite while evaluating challenges associated with high–temperature, Raman measurements of OCP materials in general.

20 FOSSIL-FUELED POWER PLANTS↗