Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Decoder”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

SU-C-BRD-03: Analysis of Accelerator Generated Text Logs for Preemptive Maintenance

Purpose: To develop a model to analyze medical accelerator generated parameter and performance data that will provide an early warning of performance degradation and impending component failure. Methods: A robust 6 MV VMAT quality assurance treatment delivery was used to test the constancy of accelerator performance. The generated text log files were decoded and analyzed using statistical process control (SPC) methodology. The text file data is a single snapshot of energy specific and overall systems parameters. A total of 36 system parameters were monitored which include RF generation, electron gun control, energy control, beam uniformity control, DC voltage generation, and cooling systems. The parameters were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and the parameter/system specification. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: the value of 1 standard deviation from the mean operating parameter of 483 TB systems, a small fraction (≤ 5%) of the operating range, or a fraction of the minor fault deviation. Results: There were 34 parameters in which synthetic errors were introduced. There were 2 parameters (radial position steering coil, and positive 24V DC) in which the errors did not exceed the limit of the I/MR chart. The I chart limit was exceeded for all of the remaining parameters (94.2%). The MR chart limit was exceeded in 29 of the 32 parameters (85.3%) in which the I chart limit was exceeded. Conclusion: Statistical process control I/MR evaluation of text log file parameters may be effective in providing an early warning of performance degradation or component failure for digital medical accelerator systems. Research is Supported by Varian Medical Systems, Inc.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-I-90: Characterizing Small Animal Lung Properties Using Speckle Observed with An In-Line X-Ray Phase Contrast Benchtop System

Purpose: We demonstrate a novel X-ray phase-contrast (XPC) method for lung imaging representing a paradigm shift in the way small animal functional imaging is performed. In our method, information regarding airway microstructure that is encoded within speckle texture of a single XPC radiograph is decoded to produce 2D parametric images that will spatially resolve changes in lung properties such as microstructure sizes and air volumes. Such information cannot be derived from conventional lung radiography or any other 2D imaging modality. By computing these images at different points within a breathing cycle, dynamic functional imaging will be readily achieved without the need for tomography. Methods: XPC mouse lung radiographs acquired in situ with an in-line X-ray phase contrast benchtop system. The lung air volume is varied and controlled with a small animal ventilator. XPC radiographs will be acquired for various lung air volume levels representing different phases of the respiratory cycle. Similar data will be acquired of microsphere-based lung phantoms containing hollow glass spheres with known distributions of diameters. Image texture analysis is applied to the data to investigate relationships between texture characteristics and airspace/microsphere physical properties. Results: Correlations between Fourier-based texture descriptors (FBTDs) and regional lung air volume indicate that the texture features in 2D radiographs reveal information on 3D properties of the lungs. For example, we find for a 350 × 350 πm2 lung ROI a linear relationship between injected air volume and FBTD value with slope and intercept of 8.9×10{sup 5} and 7.5, respectively. Conclusion: We demonstrate specific image texture measures related to lung speckle features are correlated with physical characteristics of refracting elements (i.e. lung air spaces). Furthermore, we present results indicating the feasibility of implementing the technique with a simple imaging system design, short exposures, and low dose which provides potential for widespread use in laboratory settings for in vivo studies. This research was supported in part by NSF Award CBET1263988.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

Lesion insertion in the projection domain: Methods and initial results

Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR phantom in terms of Hounsfield unit and high-contrast resolution. For the validation of the lesion realism, lesions of various types were successfully inserted, including well circumscribed and invasive lesions, homogeneous and heterogeneous lesions, high-contrast and low-contrast lesions, isolated and vessel-attached lesions, and small and large lesions. The two experienced radiologists who reviewed the original and inserted lesions could not identify the lesions that were inserted. The same lesion, when inserted into the projection domain and reconstructed with different parameters, demonstrated a parameter-dependent appearance. Conclusions: A framework has been developed for projection-domain insertion of lesions into commercial CT images, which can be potentially expanded to all geometries of CT scanners. Compared to conventional image-domain methods, the authors’ method reflected the impact of scan and reconstruction parameters on lesion appearance. Compared to prior projection-domain methods, the authors’ method has the potential to achieve higher anatomical complexity by employing clinical patient projections and real patient lesions.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-09: Predicting Accelerator Dysfunction

Purpose: To develop an integrated statistical process control (SPC) framework using digital performance and component data accumulated within the accelerator system that can detect dysfunction prior to unscheduled downtime. Methods: Seven digital accelerators were monitored for twelve to 18 months. The accelerators were operated in a ‘run to failure mode’ with the individual institutions determining when service would be initiated. Institutions were required to submit detailed service reports. Trajectory and text log files resulting from a robust daily VMAT QA delivery were decoded and evaluated using Individual and Moving Range (I/MR) control charts. The SPC evaluation was presented in a customized dashboard interface that allows the user to review 525 monitored parameters (480 MLC parameters). Chart limits were calculated using a hybrid technique that includes the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. The individual (I) grand mean values and control limit ranges of the I/MR charts of all accelerators were compared using statistical (ranked analysis of variance (ANOVA)) and graphical analyses to determine consistency of operating parameters. Results: When an alarm or warning was directly connected to field service, process control charts predicted dysfunction consistently on beam generation related parameters (BGP)– RF Driver Voltage, Gun Grid Voltage, and Forward Power (W); beam uniformity parameters – angle and position steering coil currents; and Gantry position accuracy parameter: cross correlation max-value. Control charts for individual MLC – cross correlation max-value/position detected 50% to 60% of MLCs serviced prior to dysfunction or failure. In general, non-random changes were detected 5 to 80 days prior to a service intervention. The ANOVA comparison of BGP determined that each accelerator parameter operated at a distinct value. Conclusion: The SPC framework shows promise. Long term monitoring coordinated with service will be required to definitively determine the effectiveness of the model. Varian Medical System, Inc. provided funding in support of the research presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Regulation of translation by ribosomal RNA pseudouridylation

Pseudouridine is enriched in ribosomal, spliceosomal, transfer, and messenger RNA and thus integral to the central dogma. The chemical basis for how pseudouridine affects the molecular apparatus such as ribosome, however, remains elusive owing to the lack of structures without this natural modification. Here, we studied the translation of a hypopseudouridylated ribosome initiated by the internal ribosome entry site (IRES) elements. We analyzed eight cryo–electron microscopy structures of the ribosome bound with the Taura syndrome virus IRES in multiple functional states. We found widespread loss of pseudouridine-mediated interactions through water and long-range base pairings. In the presence of the translocase, eukaryotic elongation factor 2, and guanosine 5'-triphosphate hydrolysis, the hypopseudouridylated ribosome favors a rare unconducive conformation for decoding that is partially recouped in the ribosome population that remains modified at the P-site uridine. The structural principles learned establish the link between functional defects and modification loss and are likely applicable to other pseudouridine-associated processes.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration of Communication using Neutrinos

Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decoded data rate of 0.1 bits/sec with a bit error rate of 1% over a distance of 1.035 km, including 240 m of earth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of a Runtime Data Sharing Architecture over LTE for a Heterogeneous CAV Fleet

This paper describes a lightweight runtime architecture for telemetry, communication, and control of cars deployed with advanced driver assistance systems where a human is in the loop with the car, via an LTE connection. The system architecture supports both local control decisions based on car sensors and safety algorithms as well as high-level input from external systems that may provide insight into traffic state ahead of sensor data. Implementation of the architecture is done in ROS and depends on open-source software packages for runtime decoding of information from the vehicle’s controller area network (CAN) and integration of GPS data from accompanying sensors. The contribution of the paper is to describe the overall architecture, the data it can communicate to other systems, performance of the system at runtime, and challenges faced when deploying the architecture across a heterogeneous fleet. Preliminary results from analysis of test data will provide insights into whether the use of high-latency communication can be effective for societal-scale intelligent transportation systems when applied in future scenarios

Richardson, Alex↗

Demonstrating Cross-Facility Data Processing at Scale with Laue Microdiffraction

In February and April 2023 live, at-scale data processing demonstrations were conducted between the Advanced Photon Source (APS), a synchrotron light source, and the Argonne Leadership Computing Facility (ALCF). These tests were run as part of a novel beamline technique: coded aperture laue micro-diffraction. This technique requires a significant amount of compute to decode appeture patterns embedded in the detector stream. An autonomous system was able to send data to ALCF during an experiment, utilize 50 nodes of the Polaris supercomputer to process 6-12 hour scans, and return the data back to the APS within 12-15 minutes behind the detector. With scan points arriving every 72 seconds, the system kept up with the beamline, potentially enabling in-experiment analysis. The data processing system utilizes Globus infrastructure and an on-demand queue to dynamically acquire nodes on Polaris. The underlying reconstruction algorithms were parallelized via MPI and accelerated with custom CUDA kernels.

Prince, Michael↗

Fast 2D Bicephalous Convolutional Autoencoder for Compressing 3D Time Projection Chamber Data

High-energy large-scale particle colliders produce data at high speed in the order of 1 terabytes per second in nuclear physics and petabytes per second in high energy physics. Developing real-time data compression algorithms to reduce such data at high throughput to fit permanent storage has drawn increasing attention. Specifically, at the newly constructed sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC), a time projection chamber is used as the main tracking detector, which records particle trajectories in a volume of three-dimensional (3D) cylinder. The resulting data are usually very sparse with occupancy around 10.8%. Such sparsity presents a challenge to conventional learning-free lossy compression algorithms, such as SZ, ZFP, and MGARD. The 3D convolutional neural network (CNN)-based approach, Bicephalous Convolutional Autoencoder (BCAE), outperforms traditional methods both in compression rate and reconstruction accuracy. BCAE can also utilize the computation power of graphical processing units suitable for deployment in a modern heterogeneous highperformance computing environment. This work introduces two BCAE variants: BCAE++ and BCAE-2D. BCAE++ achieves a 15% better compression ratio and a 77% better reconstruction accuracy measured in mean absolute error compared with BCAE. BCAE-2D treats the radial direction as the channel dimension of an image, resulting in a 3× speedup in compression throughput. In addition, we demonstrate an unbalanced autoencoder with a larger decoder can improve reconstruction accuracy without significantly sacrificing throughput. Lastly, we observe both the BCAE++ and BCAE-2D can benefit more from using half-precision mode in throughput (76 - 79% increase) without loss in reconstruction accuracy. The source code and links to data and pretrained models can be found at https://github.com/BNL-DAQ-LDRD/NeuralCompression_v2

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Emerging Flexible Designs for Geospatial Multimodal Foundation Models

Foundation models are rapidly transforming Earth observation by enabling scalable pretraining across diverse unlabeled geospatial modalities. However, their architectural diversity—ranging from encoder-only to encoder-decoder and masked autoencoding paradigms—makes it challenging to assess performance trade-offs in a consistent manner. In this work, we present an apples-to-apples comparison of leading FM architectures designed for geospatial multimodal reasoning, with a particular focus on flexibility across varied spectral band configurations. We standardize pretraining using identical self-supervised learning objectives and training datasets, and evaluate all models under consistent parameterization on the GEOBench benchmark across classification and segmentation tasks. Our results offer new insights into the design trade-offs between model flexibility, modality alignment, and downstream task performance. By highlighting architectural strengths and limitations under controlled conditions, this study provides practical guidance for building next-generation geospatial foundation models capable of robust multimodal reasoning.

Ambrozio Dias, Philipe [ORNL] (ORCID:0000000194277↗

Combined Mixed Potential Electrochemical Sensors and Artificial Neural Networks for the Quantificationand Identification of Methane in Natural Gas Emissions Monitoring

Sensors capable of quantifying methane concentration and discriminating between possible sources are needed for natural gas leak detection where multiple spatially overlapping sources including wetlands and agriculture may be present. We report on the fabrication by an additive manufacturing process of a four electrode La 0.87 Sr 0.13 CrO 3 , Indium Tin Oxide (In 2 O 3 90 wt%, SnO 2 10 wt%), Au, Pt mixed potential electrochemical sensor using yttria-stabilized zirconia (YSZ) as a solid electrolyte to natural gas detection. Artificial neural networks (ANNs) are used to automatically decode the possible source and concentration of methane. The ANNs trained on sensor data are capable of correctly discriminating between three sources of methane emissions from simulated mixtures of emissions from cattle, wetlands, or natural gas with >98% accuracy. Quantification error for methane in mixtures of CH 4 in air, CH 4 + NH3 in air, and simulated natural gas is less than 1.5% ppm when a two-temperature dataset is employed.

03 NATURAL GAS↗

ZFP Hardware Implementation

ZFP is a floating-point compression format gaining traction in high-performance computing applications. A software implementation has demonstrated the ability to reduce data movement across communication channels and to reduce the footprint of floating-point arrays in memory. Nevertheless, any benefit in performance is limited to the spare compute cycles available before reaching bandwidth limitations. A hardware implementation of ZFP has the potential to substantially improve HPC application performance. Hardware compression speedup over software alone on a single CPU core ranges from 15x for 1-D arrays to over 200x for 3-D arrays. The implementation of ZFP is sourced in SystemC to facilitate its evaluation in various architectures. The encode pipeline consists of several modules. Uncompressed blocks of floating-point numbers in IEEE format flow into the pipeline in a stream and a compressed bitstream flows out from the pipeline. The decode pipeline is the inverse of the encode pipeline. A modular design enables formats other than IEEE (such as posits) to be considered with minor adaptations. Best performance will be realized from the hardware ZFP unit when batches of blocks are processed at a time. The implementation supports 1-D, 2- D and 3-D blocks of floating-point numbers. The hardware implementation of ZFP has been validated with the software implementation of ZFP. C++ template parameters are used to specify the bit width of floating-point numbers and the array dimension of the encoder. A test bench program has been created with several test cases, some with continuous data that is ideal for ZFP, and others with extreme cases containing numbers near or at the maximum or minimum values supported by the number format.

Lloyd, GS↗

InterSpec v. 1.0.8

SAND2021-4823 O InterSpec decodes and displays gamma radiation data from a variety of handheld, laboratory, and fixed installation detector types. Once loaded, InterSpec provides a means to interactively analyze the data via a peak-based methodology. InterSpec assists with isotope identification and determines the source strength and shielding characteristics of the measured item. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, William↗

SpaceWire Light

SpaceWire Light is a SpaceWire encoder-decoder. It is synthesizable for FPGA targets (up to 200 Mbit on Spartan-3). Application interfaces include a simple FIFO interface, as well as an AMBA bus interface for LEON3 system-on-chip designs.

Ruckman, Larry↗

labquake_future_prediction

The labquake_future_prediction code is a collection of python modules and scripts that serves as supporting information for the article “Predicting future laboratory fault friction through deep learning” for publication in the journal of “Geophysical Research Letters”. It is designed to predict laboratory fault slips in the immediate future by scanning continuous acoustic emission (AE) waveforms recorded in laboratory biaxial shear experiments. The predictions are made with a deep learning model based on convolutional encoder-decoder (CED) models and the Transformer model primarily developed for Natural Language Processing (NLP). The deep learning model is trained with the tensorflow package using publicly available laboratory data sets in standard binary file format in numpy. The utility functions for reading data files, configuring model hyperparameters, constructing the CED and Transformer models, training and testing of the models are defined in python module files. The workflow of training the models for labquake future predictions and the multiple GPU’s rapid model hyperparameter optimization as described in the journal article, are demonstrated in accompanying python script files and Jupyter notebooks.

Wang, Kun↗

InversionNet

InversionNet is a software to solve subsurface imaging problems. It leverages a convolutional neural network with an encoder-decoder structure to model the correspondence from seismic data to subsurface velocity structures.

Lin, Youzuo↗