Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of separation.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-03: IMRT Dosimetry Differences in An Institution with Community and Academic Model

Purpose: Radiation outcome among institutions can be interpreted meaningfully if the dose delivery and prescription to the target volume is documented accurately and consistently. ICRU-83 recommended specific guidelines in IMRT for target volume definitions and dose reporting. This retrospective study evaluates the pattern of IMRT dose prescription and recording in an academic institution (AI) and a community hospital (CH) models in a single institution with reference to ICRU-83 recommendation. Materials & Methods: Dosimetric information of 625 (500 from academic and 125 from community) patients treated with IMRT was collected retrospectively from the AI and a CH. The dose-volume histogram (DVH) for the target volume of each patient was extracted. Standard dose parameters such as D2, D50, D95, D98, D100, as well as the homogeneity index (HI) defined as (D2-D98)/D50 and monitor units (MUs) were collected. Results: Significant dosimetric variations were observed in disease sites and between AI and CH. The variation in the mean value of D95 for AI is 98.48±4.12 and for CH is 96.41±4.13. A similar pattern was noticed for D50 (104.18±6.04 for AI and 101.05±3.49 for CH). Thus, nearly 95% of patients received dosage higher than 100% to the site viewed by D50 and varied between AI and CH models. The average variation of HI is found to be 0.12±0.08 and 0.11±0.08 for AI and CH model, showing better IMRT treatment plans for academic model compared to community. Conclusion: Even with the implementation of ICRU-83 guidelines, there is a large variation in dose prescription and delivery in IMRT. The variation is institution and site specific. For any meaningful comparison of the IMRT outcome, strict guidelines for dose reporting should be maintained in every institution.

60 APPLIED LIFE SCIENCES↗

Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring

Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy planning, delivery, and monitoring.

60 APPLIED LIFE SCIENCES↗

SU-C-204-01: A Dosimetric Investigation Into the Effects of Yttrium-90 Radioembolization On the GI Tract: In-Vivo and Histological Analysis in An Animal Model

Purpose: In Yttrium-90 (90Y) radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in ulceration, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. Methods: Under approval of the University of Tennessee IACUC, 6 female pigs were included in this study. Animals underwent transfemoral angiography and infusion of calibrated dosages of 90Y resin microspheres into arteries supplying part of the gastric wall. A 99mTc-MAA simulation study was performed first to determine perfused tissue volume for treatment planning along with contrast-enhanced CT. The pigs were monitored for side effects for 9 weeks, after which time they were euthanized and their upper gastrointestinal tracts were harvested for analysis. Results: 90Y radioembolization was infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1–2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastric wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microsphere deposition patterns confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a reasonable estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa may contribute to decreased toxicity of 90Y radioembolization compared to external-beam radiation therapy in gastrointestinal tissue. This project was supported by SIRTex Medical Ltd.

60 APPLIED LIFE SCIENCES↗

SU-C-204-07: Radiation Therapy as a Potential Treatment for Obesity: Initial Data from a Preclinical Investigation

Purpose: To evaluate the feasibility of Yttrium-90 (90Y) radionuclide therapy as a potential treatment for obesity in a porcine model. As the only appetite-stimulating hormone, localized targeting of ghrelin-producing X/A cells in the fundus of the stomach using 90Y may reduce serum ghrelin levels and decrease hunger. Methods: Under approval of the University of Tennessee IACUC, 8 young female pigs aged 12–13 weeks and weighing 21.8–28.1 Kg were included in this study. Six animals underwent transfemoral angiography as part of a two-day procedure involving: (1) infusion of 99mTc-MAA, followed by nuclear scintigraphy and contrast-enhanced CT for treatment-planning and (2) administration of resin 90Y microspheres into the stomach fundus. Calibrated 90Y activities were infused into the main left gastric and the gastric artery arising from the splenic to yield predetermined fundal absorbed doses. Control animals underwent a sham procedure with saline and contrast. Weekly animal weight and serum ghrelin were measured along with post-euthanasia histologic analyses of mucosal integrity and ghrelin immunoreactive cell-density. Results: 90Y radioembolization was administered to six pigs in dosages from 46.3 to 105.1 MBq resulting in average fundal absorbed doses between 35.5 and 91.9 Gy. No animal showed any signs of pain or GI complication through the duration of the study. Ghrelin immunoreactive cell-density was significantly lower in treated vs. control animals in both the stomach fundus (13.5 vs 34.8, P < 0.05) and body (11.2 vs 19.8, P < 0.05). A trend towards decreased weight gain in treated animals as well as a decrease in explanted stomach volume was also noted. Conclusion: The safety and technical feasibility of radiation therapy using 90Y radioembolization as a potential treatment for obesity has been demonstrated at fundal absorbed doses over 90 Gy. Preliminary data is suggestive of short-term safety and potential efficacy, however, further animal studies are required. Project was funded by SIRTex medical ltd.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-02: Automatic Planning as a Potential Strategy for Dose Escalation for Pancreas SBRT?

Purpose: Stereotactic body radiation therapy (SBRT) has been suggested to provide high rates of local control for locally advanced pancreatic cancer. However, the close proximity of highly radiosensitive normal tissues usually causes the labor-intensive planning process, and may impede further escalation of the prescription dose. The present study evaluates the potential of an automatic planning system as a dose escalation strategy. Methods: Ten pancreatic cancer patients treated with SBRT were studied retrospectively. SBRT was delivered over 5 consecutive fractions with 6 ∼ 8Gy/fraction. Two plans were generated by Pinnacle Auto-Planning with the original prescription and escalated prescription, respectively. Escalated prescription adds 1 Gy/fraction to the original prescription. Manually-created planning volumes were excluded in the optimization goals in order to assess the planning efficiency and quality simultaneously. Critical organs with closest proximity were used to determine the plan normalization to ensure the OAR sparing. Dosimetric parameters including D100, and conformity index (CI) were assessed. Results: Auto-plans directly generate acceptable plans for 70% of the cases without necessity of further improvement, and two more iterations at most are necessary for the rest of the cases. For the pancreas SBRT plans with the original prescription, autoplans resulted in favorable target coverage and PTV conformity (D100 = 96.3% ± 1.48%; CI = 0.88 ± 0.06). For the plans with the escalated prescriptions, no significant target under-dosage was observed, and PTV conformity remains reasonable (D100 = 93.3% ± 3.8%, and CI = 0.84 ± 0.05). Conclusion: Automatic planning, without substantial human-intervention process, results in reasonable PTV coverage and PTV conformity on the premise of adequate OAR sparing for the pancreas SBRT plans with escalated prescription. The results highlight the potential of autoplanning as a dose escalation strategy for pancreas SBRT treatment planning. Further investigations with a larger number of patients are necessary. The project is partially supported by Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-99: Dose Accumulation and Evaluation in Lung SBRT Among All Phases of Respiration

Purpose: To calculate the total planning dose on lung tumors (GTV) by accumulating the dose received in all respiration phases. Methods: A patient 4D planning CT (phase-binned, from a Siemens Somatom CT) was used to locate the GTV of a lung tumor in all respiratory phases with Pinnacle (v9.10). GTV contours defined in all phases were projected to the reference phase, where the ITV was defined. Centroids were calculated for all the GTV projections. No deformation or rotation was taken into account. The only GTV contour as defined in the reference phase was voxelized to track each voxel individually. We accumulated the absorbed dose in different phases on each voxel. A 3DCRT and a VMAT plan were designed on the reference phase fulfilling the ITV dosimetric requirements, using the 10MV FFF photon model from an Elekta Versa linac. ITV-to-PTV margins were set to 5mm. In-house developed MATLAB code was used for tumor voxeling and dose accumulation, assuming that the dose distribution planned in the reference phase behaved as a “dose-cloud” during patient breathing. Results: We tested the method on a patient 4DCT set of images exhibiting limited tumor motion (<5mm). For the 3DCRT plan, D95 was calculated for the GTV with motion and for the ITV, showing an agreement of 0.04%. For the VMAT plan, we calculated the D95 for every phase as if the GTV in that phase had received the whole treatment. Differences in D95 for all phases are within 1%, and estimate the potential interplay effect during delivery. Conclusion: A method for dose accumulation and assessment was developed that can compare GTV motion with ITV dosage, and estimate the potential interplay effect for VMAT plans. Work in progress includes the incorporation of deformable image registration and 4D CBCT dose calculation for dose reconstruction and assessment during treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-28: Evaluation of BEBIG HDR Co-60 After-Loading System for Skin Cancer Treatment Using Conical Surface Applicator

Purpose: To evaluate the possibility of utilizing the BEBIG HDR 60Co remote after-loading system for malignant skin surface treatment using Monte Carlo (MC) simulation technique. Methods: First TG-43 parameters of BEBIG-Co-60 and Nucletron Ir-192-mHDR-V2 brachytherapy sources were simulated using MCNP6 code to benchmark the sources against the literature. Second a conical tungsten-alloy with 3-cm diameter of Planning-Target-Volume (PTV) at surface for use with a single stepping HDR source is designed. The HDR source is modeled parallel to treatment plane at the center of the conical applicator with a source surface distance (SSD) of 1.5-cm and a removable plastic end-cap with a 1-mm thickness. Third, MC calculated dose distributions from HDR Co-60 for conical surface applicator were compared with the simulated data using HDR Ir-192 source. The initial calculations were made with the same conical surface applicator (standard-applicator) dimensions as the ones used with the Ir-192 system. Fourth, the applicator wall-thickness for the Co-60 system was increased (doubled) to diminish leakage dose to levels received when using the Ir-192 system. With this geometry, percentage depth dose (PDD), and relative 2D-dose profiles in transverse/coronal planes were normalized at 3-mm prescription-depth evaluated along the central axis. Results: PDD for Ir-192 and Co-60 were similar with standard and thick-walled applicator. 2D-relative dose distribution of Co-60, inside the standard-conical-applicator, generated higher penumbra (7.6%). For thick-walled applicator, it created smaller penumbra (<4%) compared to Ir-192 source in the standard-conicalapplicator. Dose leakage outside of thick-walled applicator with Co-60 source was approximately equal (≤3%) with standard applicator using Ir-192 source. Conclusion: Skin cancer treatment with equal quality can be performed with Co-60 source and thick-walled conical applicators instead of Ir-192 with standard applicators. These conical surface applicator must be used with a protective plastic end-cap to eliminate electron contamination and over-dosage of the skin.

60 APPLIED LIFE SCIENCES↗

SU-F-T-136: Breath Hold Lung Phantom Study in Using CT Density Versus Relative Stopping Power Ratio for Proton Pencil Beam Scanning System

Purpose: To evaluate mass density effects of CT conversion table and its variation in current treatment planning system of spot scanning proton beam using an IROC proton lung phantom for this study. Methods: A proton lung phantom study was acquired to Imaging and Radiation Oncology Core Houston (IROC) Quality Assurance Center. Inside the lung phantom, GAF Chromic films and couples of thermal luminescent dosimeter (TLD) capsules embedded in specified PTV and adjacent structures to monitor delivered dosage and 3D dose distribution profiles. Various material such as cork (Lung), blue water (heart), Techron HPV (ribs) and organic material of balsa wood and cork as dosimetry inserts within phantom of solid water (soft tissue). Relative stopping power (RLSP) values were provided. Our treatment planning system (TPS) doesn’t require SP instead relative density was converted relative to water. However lung phantom was irradiated by planning with density override and the results were compared with IROC measurements. The second attempt was conducted without density override and compared with IROC’s. Results: The higher passing rate of imaging and measurement results of the lung phantom irradiation met the criteria by IROC without density override. The film at coronal plane was found to be shift due to inclined cylinder insertion. The converted CT density worked as expected to correlate relative stopping power. Conclusion: The proton lung phantom provided by IROC is a useful tool to qualify our commissioned proton pencil beam delivery with TPS within reliable confidence. The relative mass stopping power ratios of materials were converted from the relative physical density relative to water and the results were satisfied.

60 APPLIED LIFE SCIENCES↗

SU-F-T-384: Step and Shoot IMRT, VMAT and Autoplan VMAT Nasopharnyx Plan Robustness to Linear Accelerator Delivery Errors

Purpose: To identify the robustness of different treatment techniques in respect to simulated linac errors on the dose distribution to the target volume and organs at risk for step and shoot IMRT (ssIMRT), VMAT and Autoplan generated VMAT nasopharynx plans. Methods: A nasopharynx patient dataset was retrospectively replanned with three different techniques: 7 beam ssIMRT, one arc manual generated VMAT and one arc automatically generated VMAT. Treatment simulated uncertainties: gantry, collimator, MLC field size and MLC shifts, were introduced into these plans at increments of 5,2,1,−1,−2 and −5 (degrees or mm) and recalculated in Pinnacle. The mean and maximum doses were calculated for the high dose PTV, parotids, brainstem, and spinal cord and then compared to the original baseline plan. Results: Simulated gantry angle errors have <1% effect on the PTV, ssIMRT is most sensitive. The small collimator errors (±1 and ±2 degrees) impacted the mean PTV dose by <2% for all techniques, however for the ±5 degree errors mean target varied by up to 7% for the Autoplan VMAT and 10% for the max dose to the spinal cord and brain stem, seen in all techniques. The simulated MLC shifts introduced the largest errors for the Autoplan VMAT, with the larger MLC modulation presumably being the cause. The most critical error observed, was the MLC field size error, where even small errors of 1 mm, caused significant changes to both the PTV and the OAR. The ssIMRT is the least sensitive and the Autoplan the most sensitive, with target errors of up to 20% over and under dosages observed. Conclusion: For a nasopharynx patient the plan robustness observed is highest for the ssIMRT plan and lowest for the Autoplan generated VMAT plan. This could be caused by the more complex MLC modulation seen for the VMAT plans. This project is supported by a grant from NSW Cancer Council.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement

Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic a human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

Lithographic crystallinity regulation in additive fabrication of thermoplastics (CRAFT)

For semicrystalline polyolefin thermoplastics, the balance between interconnected ordered crystalline and disordered amorphous regions is paramount to their performance and processability. However, contemporary manufacturing strategies, from injection molding to three-dimensional (3D) printing, result in monolithic objects, unable to spatially encode crystallinity. We develop a light-based approach for fabricating mechanically robust polyolefin thermoplastics with microscopic control over crystallinity in 3D space. Light dosage governs polymer stereochemistry giving access to a continuum of materials, from strong rigid plastics, such as high-density polyethylene, to more extensible materials akin to low-density polyethylene, all at the flick of a switch. Leveraging this finding in lithographic grayscale 3D printing enables rapid multimaterial fabrication with voxel-level control over optical and mechanical properties, opening avenues in information storage, soft robotics, and energy damping.

36 MATERIALS SCIENCE↗

Potent targeted activator of cell kill molecules eliminate cells expressing HIV-1

Antiretroviral therapy inhibits HIV-1 replication but is not curative due to establishment of a persistent reservoir after virus integration into the host genome. Reservoir reduction is therefore an important HIV-1 cure strategy. Some HIV-1 nonnucleoside reverse transcriptase inhibitors induce HIV-1 selective cytotoxicity in vitro but require concentrations far exceeding approved dosages. Focusing on this secondary activity, we found bifunctional compounds with HIV-1–infected cell kill potency at clinically achievable concentrations. These targeted activator of cell kill (TACK) molecules bind the reverse transcriptase–p66 domain of monomeric Gag-Pol and act as allosteric modulators to accelerate dimerization, resulting in HIV-1 + cell death through premature intracellular viral protease activation. TACK molecules retain potent antiviral activity and selectively eliminate infected CD4 + T cells isolated from people living with HIV-1, supporting an immune-independent clearance strategy.

Cell Biology↗

Engineered cerium oxide nanoparticles: Effects on bacterial growth and viability

Interest in engineered nanostructures has risen in recent years due to their use in energy conservation strategies and biomedicine. To ensure prudent development and use of nanomaterials, the fate and effects of such engineered structures on the environment should be understood. Interactions of nanomaterials with environmental microorganisms are inevitable, but the general consequences of such interactions remain unclear. Further, standardized methods for assessing such interactions are lacking. Therefore, we have initiated a multianalytical approach to understand the interactions of synthesized nanoparticles with bacterial systems. These efforts are focused initially on cerium oxide nanoparticles and model bacteria in order to evaluate characterization procedures and the possible fate of such materials in the environment. In this study the effects of cerium oxide nanoparticles on the growth and viability of Gram-negative Escherichia coli and Shewanella oneidensis, a metal-reducing bacteria, and Gram-positive Bacillus subtilis were examined relative to particle size, growth media, pH, and dosage. A hydrothermal based synthesis procedure was used to prepare cerium oxide nanoparticles of defined sizes in order to eliminate complications originating from the use of organic solvents and surfactants. Bactericidal effects were determined by minimum inhibitory concentration, colony forming units, disc diffusion tests and Live/Dead assays. In growth inhibition experiments involving E. coli and B. subtilis, a clear strain and size-dependent inhibition was observed. S. oneidensis appeared to be unaffected by the cerium oxide nanoparticles. Transmission electron microscopy along with microarray-based transcriptional profiling have been used to understand the response mechanism of the bacteria. The use of multiple analytical approaches adds confidence to toxicity assessments while the use of different bacterial systems highlights the potential wide-ranging effects of nanomaterial interactions in the environment.

59 BASIC BIOLOGICAL SCIENCES↗

Design Considerations for a Portable Raman Probe Spectrometer for Field Forensics

Raman spectroscopy has been shown to be a viable method for explosives detection. Currently most forensic Raman systems are either large, powerful instruments for laboratory experiments or handheld instruments for in situ point detection. We have chosen to examine the performance of certain benchtop Raman probe systems with the goal of developing an inexpensive, portable system that could be used to operate in a field forensics laboratory to examine explosives-related residues or samples. To this end, a rugged, low distortion line imaging dispersive Raman spectrograph was configured to work at 830 nm laser excitation and was used to determine whether the composition of thin films of plastic explosives or small (e.g., ≤10 μ m) particles of RDX or other explosives or oxidizers can be detected, identified, and quantified in the field. With 300 mW excitation energy, concentrations of RDX and PETN can be detected and reconstructed in the case of thin Semtex smears, but further work is needed to push detection limits of areal dosages to the ~1 μ g/cm 2 level. We describe the performance of several probe/spectrograph combinations and show preliminary data for particle detection, calibration and detection linearity for mixed compounds, and so forth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differential expression of small RNAs from Burkholderia thailandensis in response to varying environmental and stress conditions

Background: Bacterial small RNAs (sRNAs) regulate gene expression by base-pairing with downstream target mRNAs to attenuate translation of mRNA into protein at the post-transcriptional level. In response to specific environmental changes, sRNAs can modulate the expression levels of target genes, thus enabling adaptation of cellular physiology. Results: We profiled sRNA expression in the Gram-negative bacteria Burkholderia thailandensis cultured under 54 distinct growth conditions using a Burkholderia-specific microarray that contains probe sets to all intergenic regions greater than 90 bases. We identified 38 novel sRNAs and performed experimental validation on five sRNAs that play a role in adaptation of Burkholderia to cell stressors. In particular, the trans-encoded BTH_s1 and s39 exhibited differential expression profiles dependent on growth phase and cell stimuli, such as antibiotics and serum. Furthermore, knockdown of the highly-expressed BTH_s39 by antisense transcripts reduced B. thailandensis cell growth and attenuated host immune response upon infection, indicating that BTH_s39 functions in bacterial metabolism and adaptation to the host. In addition, expression of cis-encoded BTH_s13 and s19 found in the 5' untranslated regions of their cognate genes correlated with tight regulation of gene transcript levels. This sRNA-mediated downregulation of gene expression may be a conserved mechanism of post-transcriptional gene dosage control. Conclusions: These studies provide a broad analysis of differential Burkholderia sRNA expression profiles and illustrate the complexity of bacterial gene regulation in response to different environmental stress conditions.

59 BASIC BIOLOGICAL SCIENCES↗

A framework for inferring and analyzing pharmacotherapy treatment patterns

Background: To discover pharmacotherapy prescription patterns and their statistical associations with outcomes through a clinical pathway inference framework applied to real-world data. Methods: We apply machine learning steps in our framework using a 2006 to 2020 cohort of veterans with major depressive disorder (MDD). Outpatient antidepressant pharmacy fills, dispensed inpatient antidepressant medications, emergency department visits, self-harm, and all-cause mortality data were extracted from the Department of Veterans Affairs Corporate Data Warehouse. Results: Our MDD cohort consisted of 252,179 individuals. During the study period there were 98,417 emergency department visits, 1,016 cases of self-harm, and 1,507 deaths from all causes. The top ten prescription patterns accounted for 69.3% of the data for individuals starting antidepressants at the fluoxetine equivalent of 20-39 mg. Additionally, we found associations between outcomes and dosage change. Conclusions: For 252,179 Veterans who served in Iraq and Afghanistan with subsequent MDD noted in their electronic medical records, we documented and described the major pharmacotherapy prescription patterns implemented by Veterans Health Administration providers. Ten patterns accounted for almost 70% of the data. Associations between antidepressant usage and outcomes in observational data may be confounded. The low numbers of adverse events, especially those associated with all-cause mortality, make our calculations imprecise. Furthermore, our outcomes are also indications for both disease and treatment. Despite these limitations, we demonstrate the usefulness of our framework in providing operational insight into clinical practice, and our results underscore the need for increased monitoring during critical points of treatment.

60 APPLIED LIFE SCIENCES↗

TagDigger: user-friendly extraction of read counts from GBS and RAD-seq data

In genotyping-by-sequencing (GBS) and restriction site-associated DNA sequencing (RAD-seq), read depth is important for assessing the quality of genotype calls and estimating allele dosage in polyploids. However, existing pipelines for GBS and RAD-seq do not provide read counts in formats that are both accurate and easy to access. Additionally, although existing pipelines allow previously-mined SNPs to be genotyped on new samples, they do not allow the user to manually specify a subset of loci to examine. Pipelines that do not use a reference genome assign arbitrary names to SNPs, making meta-analysis across projects difficult. We created the software TagDigger, which includes three programs for analyzing GBS and RAD-seq data. The first script, tagdigger_interactive.py, rapidly extracts read counts and genotypes from FASTQ files using user supplied sets of barcodes and tags. Input and output is in CSV format so that it can be opened by spreadsheet software. Tag sequences can also be imported from the Stacks, TASSEL-GBSv2, TASSEL-UNEAK, or pyRAD pipelines, and a separate file can be imported listing the names of markers to retain. A second script, tag_manager.py, consolidates marker names and sequences across multiple projects. A third script, barcode_splitter.py, assists with preparing FASTQ data for deposit in a public archive by splitting FASTQ files by barcode and generating MD5 checksums for the resulting files. TagDigger is open-source and freely available software written in Python 3. It uses a scalable, rapid search algorithm that can process over 100 million FASTQ reads per hour. TagDigger will run on a laptop with any operating system, does not consume hard drive space with intermediate files, and does not require programming skill to use.

59 BASIC BIOLOGICAL SCIENCES↗