Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The recent discovery of high temperature ceramic superconductors with transition temperatures above 90 K has opened the possibilities for new space applications. One application is the fabrication of an electrically conducting and thermally isolating electronic link to connect IR detectors to data acquisition electronics on remote sensing platforms. The Spectroscopy of the Atmosphere using Far Infra-Red Emission (SAFIRE) mission is an example of a platform which employs hybrid dewars and combines both mechanical and cryogenic liquid cooling. This new technology is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). This link must be made of material that has high electrical conductivity and high thermal resistance. The YBa2Cu3O(x) superconductor with a transition temperature, T(sub c), of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. A reduction of the thermal load due to the link by a factor of four will increase the lifetime of a seven year mission by about one year.

Selim, Raouf L.↗

Status of direct detector and array development

Programs are now underway to develop and demonstrate the detector/array technology needed for the Space Infrared Telescope Facility (SIRTF), Large Deployable Reflector (LDR), and other future NASA missions. The development goal is to achieve focal plane sensitivities, at extended integration times over the 2 to 700 microns range, limited only by the low astrophysical backgrounds encountered in cryogenic telescopes such as SIRTF. Dramatic progress has been made in the last 2 to 3 years in integrated array and detector systems for low background astronomical applications. With the broadly based developments and lab characterizations now underway for SIRTF and similar space applications, coupled with the rapidly expanding art and science of ground based astronomical imagery with arrays, the potential for effective utilization of arrays with LDR appears to be very good.

Mccreight, Craig R.↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

DarkSide-20k (DS-20k) is a dark matter detection experimentunder construction at the Laboratori Nazionali del Gran Sasso (LNGS)in Italy. It utilises ∼ 100 t of low radioactivity argon from anunderground source (UAr) in its inner detector, with half serving astarget in a dual-phase time projection chamber (TPC). The UArcryogenics system must maintain stable thermodynamic conditionsthroughout the experiment's lifetime of over10 years. Continuous removal ofimpurities and radon from the UAr is essential for maximising signalyield and mitigating background. We are developing an efficient andpowerful cryogenics system with a gas purification loop with atarget circulation rate of1000 slpm. Central to itsdesign is a condenser operated with liquid nitrogen which is pairedwith a gas heat exchanger cascade, delivering a combined coolingpower of more than 8 kW. Here wepresent the design choices in view of the DS-20k requirements, inparticular the condenser's working principle and the coolingcontrol, and we show test results obtained with a dedicatedbenchmarking platform at CERN and LNGS. We find that the thermalefficiency of the recirculation loop, defined in terms of nitrogenconsumption per argon flow rate, is95 % and the pressure in the testcryostat can be maintained within±(0.1–0.2) mbar. Wefurther detail a 5-day cool-down procedure of the test cryostat,maintaining a cooling rate typically within-2 K/h, as required for theDS-20k inner detector. Additionally, we assess the circuit's flowresistance, and the heat transfer capabilities of two heat exchangergeometries for argon phase change, used to provide gas forrecirculation. We conclude by discussing how our findings influencethe finalisation of the system design, including necessarymodifications to meet requirements and ongoing testing activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

TES Detector Noise Limited Readout Using SQUID Multiplexers

The availability of superconducting Transition Edge Sensors (TES) with large numbers of individual detector pixels requires multiplexers for efficient readout. The use of multiplexers reduces the number of wires needed between the cryogenic electronics and the room temperature electronics and cuts the number of required cryogenic amplifiers. We are using an 8 channel SQUID multiplexer to read out one-dimensional TES arrays which are used for submillimeter astronomical observations. We present results from test measurements which show that the low noise level of the SQUID multiplexers allows accurate measurements of the TES Johnson noise, and that in operation, the readout noise is dominated by the detector noise. Multiplexers for large number of channels require a large bandwidth for the multiplexed readout signal. We discuss the resulting implications for the noise performance of these multiplexers which will be used for the readout of two dimensional TES arrays in next generation instruments.

Staguhn, J. G.↗

Implementation of a Time-domain Cosmic-Ray-Muon Tagger for the NEXUS Low-background Cryogenic Facility

Quantifying the effects of radiation on the operation of qubits both as quantum information systems as well as particle detectors has emerged as a pressing issue in quantum science in recent years. We present an overview of the design, operation, and deployment of a 90-$\mathrm{in}^2$ three-panel muon detector for use in the NEXUS experimental facility at Fermilab to temporally isolate correlated errors in qubits and determine if they possess an astrophysical origin. Constructed with three scintillator-attached PMTs read out with NIM modules in a triply-coincident logic scheme, we measure a surface-level muon luminosity of 9.7425 muons per second---consistent with an average surface-level cosmic-ray flux of approximately one muon per square centimeter per minute. Integrating the NIM modules with an MCC 128 DAQ HAT and Raspberry Pi, a Python script records exactly when a muon struck the detector and writes a timestamp to a log file for follow-up cross referencing. This experiment will broadly contribute to further studies aimed at understanding the source and mitigation of information loss in qubits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementation of a Time-domain Cosmic-ray-muon Tagger for the NEXUS Low-background Cryogenic Facility

Quantifying the effects of radiation on the operation of qubits both as quantum information systems as well as particle detectors has emerged as a pressing issue in quantum science in recent years. We present an overview of the design, operation, and deployment of a 90-$\mathrm{in}^2$ three-panel muon detector for use in the NEXUS experimental facility at Fermilab to temporally isolate correlated errors in qubits and determine if they possess an astrophysical origin. Constructed with three scintillator-attached PMTs read out with NIM modules in a triply-coincident logic scheme, we measure a surface-level muon luminosity of 9.7425 muons per second---consistent with an average surface-level cosmic-ray flux of approximately one muon per square centimeter per minute. Integrating the NIM modules with an MCC 128 DAQ HAT and Raspberry Pi, a Python script records exactly when a muon struck the detector and writes a timestamp to a log file for follow-up cross referencing. This experiment will broadly contribute to further studies aimed at understanding the source and mitigation of information loss in qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for neutrinoless β-plus-EC decay of 120 Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale cryogenic experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130 Te. In this work we describe a search for neutrinoless positron-emitting electron capture (β + EC ) decay in 120 Te with a total TeO 2 exposure of 355.7 kg yr, corresponding to 0.2405 kg yr of 120 Te. Albeit 0νββ with two final-state electrons represents the most promising channel, the emission of a positron and two 511-keV γ 's make 0νβ + EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4 × 10 22 yr at 90% credibility interval (C.I.). After unblinding we find no evidence of 0νβ + EC signal and set a 90% C.I. Bayesian lower limit of 2.9 × 10 22 yr on 120 Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A progress report on using bolometers cooled by adiabatic demagnetization refrigeration

For sensitive detection of astronomical continuum radiation in the 200 micron to 3 mm wavelength range, bolometers are presently the detectors of choice. In order to approach the limits imposed by photon noise in a cryogenically cooled telescope in space, bolometers must be operated at temperatures near 0.1 K. Researchers report progress in building and using bolometers that operate at these temperatures. The most sensitive bolometer had an estimated noise equivalent power (NEP) of 7 x 10(exp 017) W Hz(exp -1/2). Researchers also briefly discuss the durability of paramagnetic salts used to cool the bolometers.

Lesyna, L.↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗

Design Overview of the DM Radio Pathfinder Experiment

We introduce the DM Radio, a dual search for axion and hidden photon dark matter using a tunable superconducting lumped-element resonator. We discuss the prototype DM Radio Pathfinder experiment, which will probe hidden photons in the 500 peV (100 kHz)-50 neV (10 MHz) mass range. We detail the design of the various components: the LC resonant detector, the resonant frequency tuning procedure, the differential SQUID readout circuit, the shielding, and the cryogenic mounting structure. We present the current status of the pathfinder experiment and illustrate it's potential science reach in the context of the larger experimental program.

axion↗

Aerogel Scattering Filters for Cosmic Microwave Background Observations

We present the design and performance of broadband and tunable infrared-blocking filters for millimeter and sub-millimeter astronomy composed of small scattering particles embedded in an aerogel substrate. The ultra-low-density (< 100 mg/cu cm) aerogel substrate provides an index of refraction as low as 1.05, removing the need for anti-reflection coatings and allowing for broadband operation from DC to above 1 THz. The size distribution of the scattering particles can be tuned to provide a variable cutoff frequency. Aerogel filters with embedded high-resistivity silicon powder are being produced at 40-cm diameter to enable large-aperture cryogenic receivers for cosmic microwave background polarimeters, which require large arrays of sub-Kelvin detectors in their search for the signature of an inflationary gravitational-wave background.

Essinger-Hileman, Thomas↗

Aerogel Scattering Filters for Cosmic Microwave Background Observations

We present the design and performance of broadband and tunable infrared-blocking filters for millimeter and submillimeter astronomy composed of small scattering particles embedded in an aerogel substrate. The ultralow-density (typically<150 mg/cm3) aerogel substrate provides an index of refraction as low as 1.05, removing the need for antireflection coatings and allowing for broadband operation from DC to above 1 THz. The size distribution of the scattering particles can be tuned to provide a variable cutoff frequency. Aerogel filters with embedded high-resistivity silicon powder are being produced at 40 cm diameter to enable large-aperture cryogenic receivers for cosmic microwave background polarimeters, which require large arrays of sub-Kelvin detectors in their search for the signature of an inflationary gravitational-wave background.

Thomas Essinger-Hileman↗

Development of an Ultra-Low-Temperature 5-Stage Continuous Adiabatic Demagnetization Refrigerator That Provides Cooling at Two Unique Temperatures

The cryogenics group at NASA-Goddard has built several adiabatic demagnetization refrigerators (ADRs) for cooling detectors to sub-Kelvin temperatures in a lab, balloon, or space environment. The effort presented here describes the development of a new 5-stage adiabatic demagnetization refrigerator capable of providing continuous cooling at 35 mK with a cooling power double that previously demonstrated at this temperature. It will also provide a separate continuous temperature platform near 1 K. This system will be qualified using flight-like conditions, culminating in an ADR that is ready for the rigors of spaceflight by the end of the effort.

ADR↗