Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Conservation equations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

The Schwarz Alternating Method for the Seamless Coupling of Nonlinear Reduced Order Models and Full Order Models

Projection-based model order reduction allows for the parsimonious representation of full order models (FOMs), typically obtained through the discretization of a set of partial differential equations (PDEs) using conventional techniques (e.g., finite element, finite volume, finite difference methods) where the discretization may contain a very large number of degrees of freedom. As a result of this more compact representation, the resulting projection-based reduced order models (ROMs) can achieve considerable computational speedups, which are especially useful in real-time or multi-query analyses. One known deficiency of projection-based ROMs is that they can suffer from a lack of robustness, stability and accuracy, especially in the predictive regime, which ultimately limits their useful application. Another research gap that has prevented the widespread adoption of ROMs within the modeling and simulation community is the lack of theoretical and algorithmic foundations necessary for the “plug-and-play” integration of these models into existing multi-scale and multi-physics frameworks. This paper describes a new methodology that has the potential to address both of the aforementioned deficiencies by coupling projection-based ROMs with each other as well as with conventional FOMs by means of the Schwarz alternating method [41]. Leveraging recent work that adapted the Schwarz alternating method to enable consistent and concurrent multiscale coupling of finite element FOMs in solid mechanics [35, 36], we present a new extension of the Schwarz framework that enables FOM-ROM and ROM-ROM coupling, following a domain decomposition of the physical geometry on which a PDE is posed. In order to maintain efficiency and achieve computation speed-ups, we employ hyper-reduction via the Energy-Conserving Sampling and Weighting (ECSW) approach [13]. We evaluate the proposed coupling approach in the reproductive as well as in the predictive regime on a canonical test case that involves the dynamic propagation of a traveling wave in a nonlinear hyper-elastic material.

97 MATHEMATICS AND COMPUTING↗

Time reversal symmetry breaking and odd viscosity in active fluids: Green–Kubo and NEMD results

Active fluids, which are driven at the microscale by non-conservative forces, are known to exhibit novel transport phenomena due to the breaking of time reversal symmetry. Recently, Epstein and Mandadapu [arXiv:1907.10041 (2019)] obtained Green-Kubo relations for the full set of viscous coefficients governing isotropic chiral active fluids, including the so-called odd viscosity, invoking Onsager's regression hypothesis for the decay of fluctuations in active non-equilibrium steady states. In this Communication, we test these Green-Kubo relations using molecular dynamics simulations of a canonical model system consisting of actively torqued dumbbells. We find the resulting odd and shear viscosity values from the Green-Kubo relations to be in good agreement with values measured independently through non-equilibrium molecular dynamics flow simulations. This provides a test of the Green-Kubo relations and lends support to the application of the Onsager regression hypothesis in relation to viscous behaviors of active matter systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear dynamic analysis of solution multiplicity of buoyancy ventilation in a typical underground structure

Buoyancy ventilation is widely used in underground buildings, such as underground hydropower stations. Multiple solutions of buoyancy ventilation may exist in those underground structures. In this study, we developed a transient model comprising an ordinary differential equation system to describe buoyancy ventilation patterns in typical two-zone underground structures. Additionally, the accuracy of the model was validated. Nonlinear dynamical analysis was conducted to study multiple steady-state airflow. According to mathematical derivation, the configuration of one local heat source at the bottom corner introduces two stable solutions. The criterion to determine the stability and existence of solutions for more general scenarios was developed. Using this criterion, we obtained the multiple steady states of any two-zone underground buildings for different stack height ratios and the strength ratios of the heat sources. Furthermore, this criterion can be adopted for the design of buoyancy ventilation or natural smoke ventilation systems. Designers can change the height ratio of the stack or the heat ratio of two zones to induce the desired ventilation patterns. Finally, a case study was conducted with field measurements to demonstrate the use of the nonlinear dynamical analysis method to investigate the multiple steady states of buoyancy ventilation. Through the case study, we validated that the proposed criterion could produce the same result as the nonlinear dynamical analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Freundlich isotherm equation best represents phosphate sorption across soil orders and land use types in tropical soils of Puerto Rico

Biomass production in the lowland wet tropical forest is greater than in any other biome, and it is typically limited by soil phosphorus (P) availability. However, the mechanisms involved in the P cycle remain poorly represented in Earth System Models (ESMs). Soil P sorption processes are key in the P cycle and for understanding the extent of P limitation for plant productivity. Currently, a few ESMs include isotherm equations to model these processes. Although the Langmuir equation is widely cited, other isotherm equations may better describe sorption in tropical soils. Here, we use a diverse range of soil samples from Puerto Rico to test the validity of the Langmuir, Freundlich, and Temkin equation. We found that across four soil orders (Inceptisols, Mollisols, Oxisols, Ultisols), and forested and cultivated land use types, the Freundlich equation best represented soil P sorption. Furthermore, the Langmuir and the Temkin equations poorly represent soil P adsorption, especially at low P concentrations. Specifically, the Langmuir equation underestimated soil P adsorption by 40% and the Temkin equation overestimated adsorption by 76%. We also found, as expected, that soil clay content and pH were the most important parameters explaining the variability of the Freundlich (K f ) constant. Greater clay content and lower pH, common in highly weathered Ultisols and Oxisols which are abundant in the tropics, led to greater K f values. Overall, our results suggest that a diversity of soils can prompt underestimation of P sorption when using the Langmuir isotherm, which leads to an overestimation of available P that can have repercussions on ESM predictions of the P cycle and tropical forest productivity.

Earth system models↗

A First Principles Approach to Spectral Phonon Transport in Heterostructures

Understanding thermal transport across interfaces which give rise to a thermal resistance (also known as Kapitza resistance) is a critical issue affecting the development of nanotechnologies. Much modern and emergent nanotechnology consist of adjacent materials, and phonon mediated heat transfer governs thermal behavior across internal interfaces in these devices. The physics of thermal transport in solids are governed both by phenomena occurring at the atomic scale and interactions with the material's microstructure. The forecasting of fundamental quantities such as temperature, heat flux and thermal conductivity typically employs the semi-classical Boltzmann transport equation to predict the macroscopic behavior of materials in terms of the microscopic dynamics of its heat carriers. Kapitza resistance was first discovered in liquid helium experiments and has led to a fundamental research thrust in micro and nano-scale heat transport, the behavior of thermal carriers across internal interfaces. Thermal interfacial resistance (TIR) is a widely studied phenomenon, first engaged by Swartz and Pohl through their development of the acoustic and diffuse mismatch methods, then continued through myriad efforts with varying methods and approaches in an attempt to resolve carrier behavior at thermal interfaces. Many of the fundamental approaches to TIR have been at the nanoscale, and research is conducted with molecular dynamics (MD) and density functional theory (DFT) methods. The limitations of these methods is system size; atomistic methods tend to be limited to system sizes of 100,000 atoms or less. Larger length-scale methods have also been pursued, based on the principles of acoustic or diffuse mismatch, but not all include simulation of TIR using a full phonon band spectrum, or temperature dependent methods. Our approach to enabling phonon transport in layered materials draws upon our previous work of demonstrating spectrally coupled phonon transport in homogeneous and heterogeneous materials. We use a semi-analytical approach in which the Bose-Einstein (B-E) statistics set the strength of the phonon radiance in a frequency group, but the B-E statistics are informed with information from the transport system. The B-E statistics in a single frequency group feels the influence of all the groups through the spatial temperature. We also include a new field term which is an indicator of the amount of non-equilibrium behavior of the phonon spectrum---this is added to the phonon source term in all groups to ensure closure and conservation of energy, as the phonon groups in the transport system and the analytical systems are coupled. This work builds upon our previous approach by adding a phonon coupling term at an internal interface, using the principles of the DMM through transmission and reflection coefficients. In this work, the coefficients are determined through computing a common temperature at the interface, influenced by the phonon band structure of both materials, in effect, providing mixing between the two material systems and using the common temperature to set the strength of the phonon radiance at the boundaries on either side of the interface. Our approach uses material properties computed along various crystallographic orientations, and while some isotropy is built into the interface condition, the material properties weight the phonon distributions in the proper crystalline direction. Greater resolution of phonon behavior in proximity to an interface, and more accurate predictions of TIR are obtained. While it is true the assumption of diffuse mismatch can yield inconsistent results compared to experiment especially at low temperatures, this work focuses on room temperature and beyond effects, for future applications in nuclear fuel, or thermoelectric devices; a modified mismatch approach may be feasible if applied properly. Additionally, our methods focus on bridging mesoscale to engineering scale

36 MATERIALS SCIENCE↗

High salinity seawater boiling point elevation: Experimental verification

Boiling point elevation (BPE) for high salinity solutions is a crucial parameter that significantly affects the overall thermal efficiency of desalination, water treatment, and many other industrial processing systems, especially when minimum or zero liquid discharge is a key requirement. This paper addresses the discrepancies among the empirical correlations reported in the literature that were commonly used to determine BPE for seawater solutions. An evaluation of the experimental data with low solution concentration reveals that the data cannot be extrapolated to determine the BPE at high concentration (X > 140 ppt or g/kg). Besides, disparities are established within different equations used to determine the BPE for high salinity seawater. As a result of the minimal availability of experimental data of BPE for X > 140 ppt and the need to eliminate the discrepancies, an experimental setup was built, which can produce reliable and repeatable BPE data for any solution concentration. Boiling points were obtained experimentally for seawater solutions with a wide range of salinity (X between 20 and 280 ppt) and brine solution temperature (t b between 20 and 80°C). The experimental results of boiling point elevations for seawater are further compared with the experimental data and analytical results reported in the literature. The newly obtained experimental results show that the minimum and maximum BPE values for the brine solutions tested are 0.175°C at t b = 80°C and X = 20 ppt, and 11.6°C at t b = 80°C and X = 280 ppt, respectively. Furthermore, the measured BPE data for seawater concentration over 80 ppt are fitted and presented using an appropriate fitting model. The new correlation can accurately predict the BPE for high salinity seawater brines and thus should be very helpful in the design of high-energy-efficient evaporation systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

Disentangling natural and anthropogenic effects on benthic macroinvertebrate assemblages in western US streams

Abstract Stream macroinvertebrate assemblages are shaped by natural and human‐related factors that operate through complex hierarchical pathways. Quantifying these relationships can provide additional insights into stream ecological assessment. We applied a structural equation modeling framework to evaluate hypothesized pathways by which watershed, riparian, and in‐stream factors affect benthic macroinvertebrate condition in the Western Mountains (WMT) and Xeric (XER) ecoregions in the United States. We developed a conceptual model grounded in theory, empirical evidence, and expert opinion to evaluate the following hypotheses: (1) macroinvertebrate assemblages are primarily driven by proximal, in‐stream factors (e.g., water quality and physical habitat); (2) anthropogenic land uses affect macroinvertebrates indirectly by altering in‐stream characteristics; and (3) riparian vegetation cover attenuates land use effects. We tested our model separately on three measures of benthic macroinvertebrate assemblage condition: ratio of observed‐to‐expected taxonomic richness (O/E); a multimetric index (MMI); and richness of Ephemeroptera, Plecoptera, and Trichoptera taxa (EPT). In the WMT, site‐level riparian cover, in‐stream physical habitat (relative bed stability), and water chemistry (total nitrogen) were the top three predictors of macroinvertebrate assemblages, each having over two times the magnitude of effect on macroinvertebrates compared with watershed‐level predictors. In the arid XER, annual precipitation and stream flow characteristics were top predictors of macroinvertebrate assemblages and had similar magnitudes of effect as in‐stream water chemistry. Path analyses revealed that land use activities in the watershed and at the stream site degraded macroinvertebrate assemblages indirectly by altering relative bed stability, water quality, and riparian cover/complexity. Increased riparian cover was associated with greater macroinvertebrate condition by reducing land use impacts on stream flow, streambed substrate, and water quality, but the pathways differed among ecoregions. In the WMT, site‐level riparian cover affected macroinvertebrate assemblages partly through indirect pathways associated with greater streambed stability and reduced total nitrogen concentrations. In contrast, in the XER, watershed‐level riparian cover affected macroinvertebrate assemblages through greater specific stream power. Identifying the relative effects of and pathways by which natural and anthropogenic factors affect macroinvertebrates can serve as a framework for prioritizing management and conservation efforts.

Environmental Sciences & Ecology↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local analysis of fast magnetic reconnection

Fast magnetic reconnection is defined by the topology of the magnetic field lines changing on a timescale that is approximately an order of magnitude longer than the topology-conserving ideal-evolution timescale. Fast reconnection is an intrinsic property of Faraday's law when the evolving magnetic field depends non-trivially on all three spatial coordinates and is commonly observed—even when the effects that allow topology breaking are arbitrarily small. The associated current density need only be enhanced by a factor of approximately ten and flows in thin but broad ribbons along the magnetic field. These results follow from the variation in the separation of neighboring pairs of magnetic field lines, which in an ideal evolution typically increases exponentially with time, and the existence of a spatial scale below which magnetic field lines freely change their identities due to non-ideal effects, such as resistivity. Traditional reconnection theory ignores exponentially large variations and relies on the current density reaching a magnitude that is exponentially larger than is actually required. Here, an analysis of the behavior of magnetic field lines in the neighborhood of an arbitrarily chosen line is used to obtain more precise and rigorous results on intrinsic reconnection. The maximum parallel kinetic energy of collisionless charged particles is shown to have an exponential increase in time during a generic magnetic evolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Steam generator model design parameter sensitivity study for small modular reactor system

Here, this study focuses on design parameter sensitivity studies pertaining to several Once-Through Steam Generator (OTSG) model cases both with and without a riser using python and advanced risk assessment and optimization tool, i.e. Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), to support a Small Modular Reactor (SMR) system. The presented Steam Generator (SG) python-based model is a mathematical representation of a steam-generating unit for a Pressurized Water Reactor (PWR)-type SMR system, including fluid flow and heat transfer equations, models, and correlations. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system, such as the Heat Transfer Coefficient (HTC), Reynolds number, Nusselt number, and heat transfer performance. Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in the input parameters. By using RAVEN, detailed design parametric sensitivity studies. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10 % relative changes) for 600 samples. The analysis results give valuable insights into SG system performance, and provide justification for further research and development such as optimized sensor placement, design verification, validation, and optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Predicting U.S. federal fleet electric vehicle charging patterns using internal combustion engine vehicle fueling transaction statistics

Utilizing fueling transactions from internal combustion engine vehicles (ICEVs), the authors estimated how frequently midday public charging would be required for U.S. federal fleet battery electric vehicles (BEVs). Fueling transaction summary statistics are more widely available than trip-level telematics data, making this methodology more accessible and transferable to other researchers and fleet managers considering BEV replacements. For example, readers can easily apply a linear model using only the count of back-to-back fueling events at gas stations over 57 straight-line miles apart to predict days exceeding range. This linear regression predicted binned days exceeding 250 miles at 80% accuracy on a hold-out test set from the same fleet as the training data and 66 % accuracy on a new fleet displaying different driving behaviors. The authors additionally provide linear equations for days exceeding 200 and 300 miles as alternative range estimates to account for differences in BEV range and temperature impacts. Beyond the single-feature linear models which readers can apply, the authors tuned and trained other machine learning models on a variety of fueling transaction statistics including consecutive transaction distances, transaction distance from garage, estimated miles traveled from fuel economy and fuel quantity, and transaction periodicity. Utilizing a subset of 1678 light-duty federal fleet vehicles which contained daily vehicle miles traveled (VMT) in addition to fueling statistics, the authors determined which fueling transaction statistics were most relevant in predicting driving days exceeding 250 miles (an approximation of BEV rated driving range). In support of the U.S. federal fleet transition to zero-emission vehicles (ZEVs), the authors used these statistics and machine learning models to predict the frequency of BEV midday charging. After training models on the subset with VMT, the authors predicted days exceeding rated range for 112,902 light-duty vehicles operating in similar circumstances in the federal fleet using a Support Vector Regressor (SVR). In conclusion, they then used the projections as part of the ZEV Planning and Charging (ZPAC) tool to identify optimal candidates for BEVs for the federal fleet. An anonymized version of ZPAC is included in the supplementary materials.

25 ENERGY STORAGE↗

A NICER View of the Massive Pulsar PSR J0740+6620 Informed by Radio Timing and XMM-Newton Spectroscopy

We report on Bayesian estimation of the radius, mass, and hot surface regions of the massive millisecond pulsar PSR J0740+6620, conditional on pulse-profile modeling of Neutron Star Interior Composition Explorer X-ray Timing Instrument event data. We condition on informative pulsar mass, distance, and orbital inclination priors derived from the joint North American Nanohertz Observatory for Gravitational Waves and Canadian Hydrogen Intensity Mapping Experiment/Pulsar wideband radio timing measurements of Fonseca et al. We use XMM-Newton European Photon Imaging Camera spectroscopic event data to inform our X-ray likelihood function. The prior support of the pulsar radius is truncated at 16 km to ensure coverage of current dense matter models. We assume conservative priors on instrument calibration uncertainty. We constrain the equatorial radius and mass of PSR J0740+6620 to be ${12.39}_{-0.98}^{+1.30}$ km and ${2.072}_{-0.066}^{+0.067}$ M ⊙ respectively, each reported as the posterior credible interval bounded by the 16% and 84% quantiles, conditional on surface hot regions that are non-overlapping spherical caps of fully ionized hydrogen atmosphere with uniform effective temperature; a posteriori, the temperature is ${\mathrm{log}}_{10}(T\,[{\rm{K}}])={5.99}_{-0.06}^{+0.05}$ for each hot region. All software for the X-ray modeling framework is open-source and all data, model, and sample information is publicly available, including analysis notebooks and model modules in the Python language. Furthermore, our marginal likelihood function of mass and equatorial radius is proportional to the marginal joint posterior density of those parameters (within the prior support) and can thus be computed from the posterior samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum kinetic modeling of KEEN waves in a warm-dense regime

We report the first fully kinetic, quantum study of kinetic electrostatic electron nonlinear (KEEN) waves, showing that quantum diffraction systematically erodes the classical trapping mechanism, narrows harmonic locking to the fundamental, and hastens post-drive decay. Electrons are evolved with a second-order Strang-split 1D1V Wigner–Poisson solver that couples conservative semi-Lagrangian WENO advection to an analytic Fourier space update for the non-local Wigner term, while ions remain classical. We focus on collisionless dynamics in a weakly coupled regime, providing a controlled baseline before collisional extensions. Short, frequency-tuned ponderomotive pulses drive KEEN formation in a uniform Maxwellian plasma; as the dimensionless quantum parameter H rises from the classical limit to values relevant to warm-dense matter, doped semiconductors, and 2D electron systems, the drive threshold increases, higher harmonics are damped, trapped electron vortices diffuse, and the subplasma electrostatic energy relaxes to a lower stationary level, as confirmed by continuous wavelet analysis. These microscopic changes carry macroscopic weight. Ignition-scale capsules now compress matter to regimes where the electron de Broglie wavelength rivals the Debye length, making classical kinetic descriptions insufficient. By extending KEEN physics into this quantum domain, our results offer a potential diagnostic of non-equilibrium electron dynamics for next-generation inertial-confinement designs and high-energy-density platforms, indicating that predictive fusion modeling may benefit from the integration of kinetic fidelity with quantum effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terrain-Influenced Winds and Fire-Fire Interactions in Wildland Fire Simulations [Dissertation]

Ensemble-based approaches to prescribed fire planning cannot be supported by computational fluid dynamics based models like FIRETEC and the Wildland-Urban Interface Fire Dynamics Simulator (WFDS) because they are too computationally expensive and cannot leverage large eddy simulation approaches like CAWFE and WRF-SFIRE because they have too coarse of resolution. QUIC-Fire was developed to fill this gap but it cannot currently address complex terrain, that is typical for instance in the Western United States. This dissertation describes a variety of improvements made to QUIC-Fire and its various incorporated algorithms in an effort to make it a viable tool in simulating wildland and prescribed fires on terrain. The modifications made to QUIC-Fire are described in three chapters. The first chapter describes the extension of the diagnostic wind model QUIC-URB, the wind engine of QUIC-Fire, to a terrain-following coordinate system. The terraininfluenced winds it generates are analyzed and compared. In particular, this chapter presents the mathematical derivation of the wind solver leading to a linear system of equations that are solved through the successive over-relaxation method. The model is validated against a standard test used in previous works (the Askervein Hill) and against a new dataset from measurements in the Socorro Mountains, New Mexico. The terrain-following implementation captures the correct phenomenology for the isolated Askervein Hill, with a wind speed up at the top of the hill. The model agrees well with measurements on the upwind side of the peak, but overestimates speed-up on the downwind side of the hill. This is due to the inability of the model to generate flow separation and wake-eddy dynamics. On a common laptop, the divergence-free wind field is obtained in 6 s, making the solver appealing for coupled fire-atmosphere simulations. The Socorro Mountain is highly complex, with many cliff faces, peaks, and valleys. Although the model captures the magnitude and direction of inlet and outlet areas of the domain, it performs rather poorly in the valley region and in the regions near the steep cliffs. Hence, the model shows good agreement with data in areas of open sloped terrain but lacks in areas where flow separation and thermally driven effects may be present (neither effect is addressed in this work). In the second chapter the implementation of the terrain-following version of QUIC-URB into QUIC-Fire, and the necessary changes needed to include terrain are described. No changes to the underlying fire spread algorithm are made other than what is required to correctly account for the inclusion of terrain. Previously published FIRETEC results that use five different topographies that share the same centerline profile are compared to simulation results from the modified QUIC-Fire that use the same topographies and fuels. QUIC-Fire results show overall similar behaviors in terms of how the topographies affect fire shapes and trends in spread rates. Due to the terrain-following version of QUIC-URB being unable to generate flow separations at the crest of hills, fire spread rates in these regions across all topographies are over-predicted when compared to FIRETEC. Lateral fire growth shows similar trends with FIRETEC between topographies but does not capture the increase in spread due to a diagonal interface between grassland and forested fuel region of the domain. These results suggest that there are three algorithms within QUIC-Fire that could use improvement: how flame tilt angle is accounted for, the incorporation of non-local drag effects, and the inclusion of the wake-eddy parameterizations that are used in QUIC-URB. Lastly, the third chapter describes a modification to the initial guess used for the calculation of the QUIC-URB mass-conserved wind solution during fire simulations. The modification is aimed at improving fire-fire interactions in QUIC-Fire simulations. The modification consists of using the solution from the previous timestep as the starting point for the calculation of the solution for the next timestep. Fire-fire interactions is greatly improved by the change but a new source of error is introduced. Due to how plumes are modelled in QUIC-Fire the new solution contains errors where gaps in the plume structure are present. However, these errors are mostly limited to the upper atmosphere, where they do not affect fire behavior at the surface, and their magnitude isn’t significant enough to discount the amount of new fire phenomenology now captured in QUIC-Fire with the change.

58 GEOSCIENCES↗