Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

Dysfunctionality Hazard Curve: Risk-Based Tool to Support the Resilient Design of Systems Subjected to Multihazards

While resilience metrics have been proposed and studied given a functionality recovery curve, they have not emphasized enough on accounting for the uncertainties in the multihazard occurrences and intensities. Moreover, these resilience metrics are not risk-based (i.e., they do not express the system's resilience loss as a frequency of exceedance), leading to inconsistencies in system performance description when compared to performance-based engineering frameworks. A risk-based tool termed dysfunctionality hazard curve is proposed to assess the resilience of systems subjected to single hazards or multihazards with inter-event dependencies. Dysfunctionality hazard curve expresses system resilience performance as frequency of exceedance of time to full functionality. In doing so, it characterizes system recovery as a sequence of repair activities and also considers the uncertainties in the multihazard occurrences and intensities. Dysfunctionality hazard curve is demonstrated for a residential building susceptible to earthquake and hurricane hazards. Results indicate that Dysfunctionality hazard curve for earthquakes is greater than that for hurricane winds under single hazards. Under multihazards, considering inter-event dependencies during system recovery leads to larger dysfunctionality hazard curve than ignoring them. Finally, the concept of dysfunctionality hazard curve is also extended to a system-of-systems consisting of residential and commercial buildings.

42 ENGINEERING↗

HVAC Duct Pressure Optimization System

The US Department of Energy, the California Energy Commission, and other public and private entities including the venture capital community are seeking technical solutions that include “smart, grid-interactive, efficient buildings - to best serve the needs of building occupants and the grid while reducing energy consumption overall.” In this paper, a systems engineering approach is used to examine elements of a prior proof-of-concept project along with new ideas seeking to justify additional research funding to further advance the technology. With additional research and development funding, the technology described here has the potential to achieve success toward development of a commercially viable product. These types of projects provide financial and environmental benefit to American taxpayers and investors. Cost effectiveness and return on investment are key criteria for energy efficiency projects. By evaluating the end-to-end processes including manufacturing, installation, commissioning and comparing various options, we arrived at a proposed implementation concept of a HVAC Duct Pressure Optimization System that saves energy in commercial buildings and improves the return on investment by a factor of 6X compared to previous research projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tides on South Mill Apartment Complex

This dataset includes data from the building management system for a large multi-family rental property located in Tempe, Arizona. The name of this rental property is “Tides on South Mill” and it is owned by the FCP which is a real-estate investment company based in Maryland with a large portfolio of rental properties that spreads out throughout the U.S. FCP’s portfolio includes large multi-family housing and commercial buildings. The property is split into four quadrants. Each quadrant has roughly 130 apartments. The total floor area of each Quadrant is about 94,000 sq. ft. The campus of Solara spreads over 27 acres. The mechanical system consists of a 2-pipe system that runs chilled or hot water thru individual Fan Coil Units depending upon the season. The gas-fired boiler will supply hot water when seasonal change-over will take place. This dataset spans October to December 2021 and includes time-series measurements corresponding electricity meter data (Cooling Tower Fan, Pumps, Chillers,) with 1-minute resolution, chilled water temperature data and outside air data with 5-minute resolution etc. as CSV files. In addition to the measurements, a metadata .json file, and a .pdf dataset description file are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor and Actuator Attacks on Hierarchical Control Systems with Domain-Aware Operator Theory

Cyber-Physical Systems (CPSs) provide opportunities for cyber attacks to have physical impacts. Advanced Persistent Threats (APTs) are a subclass of cyber threats that act stealthily to avoid detection and enable long-term attacks. Here, we build on our past work in APT modelling to combine deception-based sensor bias attacks and direct actuator manipulations in attacks against a hierarchical control system. That past work used the Koopman operator to develop a data-driven, domain-aware, optimization-based attacker model. Using an expansion of this model, we compute several different attacks, including multiple simultaneous attacks, against a high-fidelity commercial building emulator and compare the impacts of those attacks to each other. One next step of interest is to construct a defender system, built on the same modelling approach, designed to detect and mitigate such attacks.

koopman operator, Cyber-Physical Security, machine↗

Design and Fabrication of Polyisocyanurate Foams toward Significantly Enhanced Thermal Resistivity

Developing high-performance thermal insulation is vital for addressing the ongoing global demand for reduced energy costs. Polyisocyanurate (PIR) foams are commonly used in residential and commercial buildings and in various industrial applications owing to their relatively high thermal insulation properties and fire resistivity. Here, this study aims to further improve the thermal resistivity of PIR foams by (1) incorporating low thermal conductivity blowing agents; (2) tailoring the anisotropy of their cells; (3) tuning polymeric isocyanate quantities; and (4) incorporating a facer barrier, while using steps that easily integrate into current manufacturing processes for PIR foams. The resulting PIR foams exhibit a significant enhancement in thermal resistivity, achieving initial values as high as 8.3 h·ft 2 ·°F/Btu/in., commonly abbreviated as R-8.3/in., which is a 20% improvement compared with that of commercially used PIR foams that achieve approximately R-7/in. The detailed analysis of thermal conductivity measurements, mechanical testing, and morphological characterization elucidates the structure–property relationships. The developed high-performance PIR foams provide a critical pillar for next-generation high-performance insulation, offering promising thermal insulation for buildings and many other applications that have a significant effect on global energy costs.

Anisotropic pores↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Semantic Interoperability to Enable Smart, Grid-Interactive Efficient Buildings

Achieving a widespread transition to grid-interactive, efficient buildings (GEBs) depends critically on there being sufficient interoperability among connected building systems. While many critical elements already exist at the technical interoperability level (TCP/IP, BACnet, etc.), a lack of interoperability in the semantic level hinders streamlined integration of interdependent applications. Semantics refers to expressing information about “things” in a way that can be consistently understood by applications. Key components of formalized semantics include identifying what a “thing” is (its “type”), defining general information about that “thing” (its characteristics or properties), and defining the appropriate relationships of that “thing” to other “things” (its function or role in a larger system). Although this might seem initially trivial, the success of smart building applications is highly dependent on maintaining consistent notions of the “things” being self-descriptive. Without semantic interoperability, it is technically difficult, labor-intensive, and cost-prohibitive to enable three key objectives of GEBs: optimizing performance, identifying faults, and delivering grid services. Industry, academia, and standards bodies have invested effort in developing information models to facilitate semantic interoperability, however, they have not been widely adopted across the U.S. commercial building portfolio. This paper will present a pathway to drive semantic interoperability through a three-pronged approach to be led by the DOE Building Technologies Office in partnership with NIST and multiple national laboratories comprising: 1) industry engagement and coordination across existing efforts; 2) a semantic interoperability standard that empowers building owners to identify and require interoperable attributes when procuring equipment and applications; 3) tools to assist in implementation and a test framework that can verify compliance of products with semantic interoperability specifications. This strategic approach is designed to accelerate the timeline for adoption of semantic interoperability standards. The intent is to reduce soft costs associated with implementing advanced controls, fault detection and diagnostics, and other smart building technologies as a necessary step in achieving an energy efficient smart grid future.

semantic interoperability, Semantic modeling, inte↗

Semantic Interoperability to Enable Smart, Grid-Interactive Efficient Buildings

Achieving a widespread transition to grid-interactive, efficient buildings (GEBs) depends critically on there being sufficient interoperability among connected building systems. While many critical elements already exist at the technical interoperability level (TCP/IP, BACnet, etc.), a lack of interoperability in the semantic level hinders streamlined integration of interdependent applications. Semantics refers to expressing information about “things” in a way that can be consistently understood by applications. Key components of formalized semantics include identifying what a “thing” is (its “type”), defining general information about that “thing” (its characteristics or properties), and defining the appropriate relationships of that “thing” to other “things” (its function or role in a larger system). Although this might seem initially trivial, the success of smart building applications is highly dependent on maintaining consistent self-descriptive notions of the “things”. Without semantic interoperability, it is technically difficult, labor-intensive, and cost-prohibitive to enable three key objectives of GEBs: optimizing performance, automatically identifying and diagnosing faults, and delivering grid services. Industry, academia, and standards bodies have invested effort in developing information models to facilitate semantic interoperability, however, they have not been widely adopted across the U.S. commercial building portfolio. This paper will present a pathway to drive semantic interoperability through a three-pronged approach to be led by the DOE Building Technologies Office in partnership with NIST and multiple national laboratories comprising: 1) industry engagement and coordination across existing efforts; 2) a semantic interoperability standard that empowers building owners to identify and require interoperable attributes when procuring equipment and applications; 3) tools to assist in implementation and a test framework to verify compliance of products with semantic interoperability specifications. This approach is designed to accelerate the timeline for adoption of semantic interoperability specifications. The intent is to reduce soft costs associated with implementing advanced controls, fault detection and diagnostics, and other smart building technologies and use cases as a necessary step in achieving an energy efficient smart grid future.

Bergmann, Harry↗

Semantic Interoperability to Enable Smart, Grid-Interactive Efficient Buildings

Achieving a widespread transition to grid-interactive, efficient buildings (GEBs) depends critically on there being sufficient interoperability among connected building systems. While many critical elements already exist at the technical interoperability level (TCP/IP, BACnet, etc.), a lack of interoperability in the semantic level hinders streamlined integration of interdependent applications. Semantics refers to expressing information about “things” in a way that can be consistently understood by applications. Key components of formalized semantics include identifying what a “thing” is (its “type”), defining general information about that “thing” (its characteristics or properties), and defining the appropriate relationships of that “thing” to other “things” (its function or role in a larger system). Although this might seem initially trivial, the success of smart building applications is highly dependent on maintaining consistent self-descriptive notions of the “things”. Without semantic interoperability, it is technically difficult, labor-intensive, and cost-prohibitive to enable three key objectives of GEBs: optimizing performance, automatically identifying and diagnosing faults, and delivering grid services. Industry, academia, and standards bodies have invested effort in developing information models to facilitate semantic interoperability, however, they have not been widely adopted across the U.S. commercial building portfolio. This paper will present a pathway to drive semantic interoperability through a three-pronged approach to be led by the DOE Building Technologies Office in partnership with NIST and multiple national laboratories comprising: 1) industry engagement and coordination across existing efforts; 2) a semantic interoperability standard that empowers building owners to identify and require interoperable attributes when procuring equipment and applications; 3) tools to assist in implementation and a test framework to verify compliance of products with semantic interoperability specifications. This approach is designed to accelerate the timeline for adoption of semantic interoperability specifications. The intent is to reduce soft costs associated with implementing advanced controls, fault detection and diagnostics, and other smart building technologies and use cases as a necessary step in achieving an energy efficient smart grid future.

30 DIRECT ENERGY CONVERSION↗

Photovoltaic device innovation for a solar future

Photovoltaics (PV), also known as solar cells, are now found everywhere - in utility plants; on roofs of homes and commercial buildings; on platforms at sea; in agricultural fields; on vehicles, buildings, drones, and backpacks; and, in their longest running application, providing power in space. Continuous device innovation has led to increased efficiency and improved reliability for multiple PV technologies. Confronted with an urgent need to deploy PV at multiterawatt (TW) scale over the next two decades to mitigate greenhouse gas emissions, PV device innovation takes on new urgency and impact. This perspective reviews recent progress in device design and performance for PV technologies that are currently in commercial production at greater than 1 GW/year or enabling significant space-based power generation - Si, CdTe, CIGS, and multijunction III-V - and looks ahead to the next 5 years. In conclusion, we also identify device-related topics requiring cross-cutting research and innovation.

14 SOLAR ENERGY↗

RENEWABLE MARINE-SOURCE INTEGRATED HEAT PUMP FOR SPACE CONDITIONING, WATER HEATING, AND FRESH WATER HARVESTING IN REMOTE COASTAL AND ISLAND COMMUNITIES

US coastal and island communities have vulnerable energy infrastructure and high energy costs, which are exacerbated by climate change. A unique opportunity exists to use thermal energy from year-round mild temperature variations to satisfy the broad energy needs of these communities. The US Department of Energy’s Oak Ridge National Laboratory designed a small-scale marine-source integrated heat pump (MS-IHP) that, as a single appliance, combines space conditioning, dehumidification (including fresh water harvesting from humid air), and water heating for home and commercial building applications in remote coastal and island communities. The unique, innovative features of the MS-IHP offer improved efficiency and substantially reduced costs for space conditioning, dehumidification, and water heating by seamlessly integrating a heat pump, heat pump water heater, and dehumidifier by using a single compressor; optimal year-round space cooling and heating, dehumidification, water harvesting, and water heating; and improved thermal comfort and reliable operation without frosting and defrosting because of the ocean’s warm temperatures and high heat capacity. Preliminary testing was conducted by retrofitting a commercial heat pump, demonstrating an outperformed performance compared with traditional air-source heat pumps. The MS-IHP technology can help decarbonize energy systems in remote coastal and island communities.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Transfer-Learnt Energy Models for Predicting Electricity Consumption in Buildings with Limited and Sparse Field Data

Modeling energy consumption is critical for energy-efficient utilization of the electric appliances in a building, smart grid programs (like demand-response), and many other smart home applications. State-of-the-art energy modeling techniques either rely on theoretical models, or extensive instrumentation of the building envelope to gather ``big" data to train a deep neural network. While theoretical models are often limited by their estimation accuracy, it is not always feasible to gather a significant amount of field data. In this paper, we explore transfer learning-based strategies to train much more accurate model for energy estimation when using a sparse field data. We transferred knowledge, in the form of data and parameters, from the simulation framework to the field data. We evaluated the efficacy of our approach on field data collected from six commercial buildings and our results indicate that transfer learning-based models trained over one month data can perform comparative (and in some cases better) than the state-of-the-art machine learning and deep learning solutions.

Jain, Milan↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Simplified Building Modeling Approach for Identifying Whole Building Retrofits

Building Energy Modeling (BEM) is an effective strategy for optimizing new and retrofit building design, evaluating its energy savings potential and rating its energy performance. However, because of the complexity and expense of modeling, only a small percentage of buildings are simulated. Over 80% of buildings are <25,000 ft2, and the cost associated with BEM can be a big deterrent for reaching this subsector, which usually ends up complying with energy codes and qualifying for incentives using prescriptive measures or generalized design guides. Similarly, efficiency considerations for small building retrofits are often identified through deemed measures or Technical Reference Manuals, which though a scalable and convenient approach, can limit innovation in design and optimization of measures. Simplification of the modeling process, where appropriate, can lead to increased energy savings and more informed decision making. This paper will discuss the development of a ruleset for a simplified approach based on the Performance Rating Method (PRM) contained in ASHRAE Standard 90.1. The approach aims to simplify and lower the cost of the energy modeling process in a controlled and documented manner. An anticipated outcome is an increased use of BEM and its effectiveness in the design, retrofit and operation of commercial buildings. In addition, simplification of the modeling process will result in fewer errors from misinterpretations of both program requirements and program intent in simulation software. The paper will discuss the need and advantages of a simplified modeling approach for whole building retrofits and the technical process for achieving the same.

Goel, Supriya↗

Two-Stage Reinforcement Learning Policy Search for Grid-Interactive Building Control

This paper develops an intelligent grid-interactive building controller, which optimizes building operation during both normal hours and demand response (DR) events. To avoid costly on-demand computation and to adapt to non-linear building models, the controller utilizes reinforcement learning (RL) and makes real-time decisions based on a near-optimal control policy. Learning such a policy typically amounts to solving a hard non-convex optimization problem. We propose to address this problem with a novel global-local policy search method. In the first stage, an RL algorithm based on zero-order gradient estimation is leveraged to search for the optimal policy globally, due to its scalability and the potential to escape some poor performing local optima. The obtained policy is then fine-tuned locally to bring the first-stage solution closer to that of the original unsmoothed problem. Experiments on a simulated five-zone commercial building demonstrate the advantages of the proposed method over existing learning approaches. They also show that the learned control policy outperforms a pragmatic linear model predictive controller (MPC) and approaches the performance of an oracle MPC in testing scenarios. Using a state-of-the-art advanced computing system, we demonstrate that the controller can be learned and deployed within hours of training.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop Unit (RTU) Maintenance Guide

The commercial buildings industry has long emphasized affordability, energy efficiency, and useful service life in rooftop unit (RTU) equipment. The trade-offs between these characteristics can impact decisions about the initial cost of equipment and ongoing operating costs. Often, the desire for lower initial costs leads to adoption of low-efficiency systems or neglect of proper maintenance in the interest of short-term cost savings. Maintenance of these systems is a critical step to ensure system efficiency and reliability, low operating costs, and a reasonable payback period. This guide is intended for facility managers who own or are interested in purchasing and installing RTUs and need to familiarize themselves with the maintenance requirements. This resource contains best practices, important considerations, and additional information related to commercial RTU equipment, but does not replace manufacturer-specific instructions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗