Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A CCD comparison of outer Jovian satellites and Trojan asteroids

The eight small outer Jovian satellites are not as well known as the brighter, more illustrious Galilean satellites. They are divided into two groups, each containing four satellites; the inner group travels in prograde orbits while the outer group travels in retrograde orbits. From the distinct orbital characteristics of the two groups, most of the theories of their origin involve the capture and breakup of two planetesimals upon entry into the atmosphere of proto-Jupiter. Their proximity to the Trojans asteroids has led to conjectures of a link between them and the Trojans. However, Tholen and Zellner (1984) found no red spectrum among six of the satellites and postulated that they were all C-type objects; therefore, they were unlikely to be derivatives of the Trojan population. Charge-coupled device (CCD) photometry and spectroscopy of the eight outer Jovian satellites obtained from 1987 to 1989 and a comparison between these eight satellites and the Trojan asteroids are presented.

Luu, Jane X.↗

Significant reduction in arc frequency biased solar cells: Observations, diagnostics, and mitigation technique(s)

A variety of experiments were performed which identify key factors contributing to the arcing of negatively biased high voltage solar cells. These efforts have led to reduction of greater than a factor of 100 in the arc frequency of a single cell following proper remediation procedures. Experiments naturally lead to and focussed on the adhesive/encapsulant that is used to bond the protective cover slip to the solar cell. An image-intensified charge coupled device (CCD) camera system recorded UV emission from arc events which occurred exclusively along the interfacial edge between the cover slip and the solar cell. Microscopic inspection of this interfacial region showed a bead of encapsulant along this entire edge. Elimination of this encapsulant bead reduced the arc frequency by two orders of magnitude. Water contamination was also identified as a key contributor which enhances arcing of the encapsulant bead along the solar cell edge. Spectrally resolved measurements of the observable UV light shows a feature assignable to OH(A-X) electronic emission, which is common for water contaminated discharges. Experiments in which the solar cell temperature was raised to 85 C showed a reduced arcing frequency, suggesting desorption of H2O. Exposing the solar cell to water vapor was shown to increase the arcing frequency. Clean dry gases such as O2, N2, and Ar show no enhancement of the arcing rate. Elimination of the exposed encapsulant eliminates any measurable sensitivity to H2O vapor.

Upschulte, B. L.↗

Advanced CCD imager technology for use from 1 to 10,000 A

A low-noise, high-sensitivity charge-coupled-device (CCD) technology for imaging applications extending from the soft X-ray (1 A) to the near-infrared (10,000 A) regimes was developed together with a fabrication technology for making back-illuminated versions of these devices with quantum efficiencies as high as 90 percent from 5000 to 7000 A. The efforts have focused on two devices, a 64 x 64 pixel back-illuminated imager with two output ports that operates at 2000 frames per second with 23 electrons read noise, and a larger device, with 420 x 420 pixel format, designed for lower frame rates with noise as low as 1.5 electrons and used at visible, UV, and X-ray wavelengths. Applications to plasma diagnostics include Thomson scattering and high-frame-rate imaging in the visible, as well as X-ray imaging and bolometry.

Twichell, J. C.↗

Luminescent barometry in wind tunnels

A flexible and relatively inexpensive method and apparatus are described for continuous pressure mapping of aerodynamic surfaces using photoluminescence and imaging techniques. Platinum octaethylporphyrin (PtOEP) has a phosphorescence known to be quenched by oxygen. When dissolved in a silicone matrix, PtOEP may be distributed over a surface as a thin, uniform film. When the film is irradiated with ultraviolet light, the luminescence intensity provides a readily detectable, qualitative surface flow visualization. Moreover, since the luminescence intensity is found to be inversely proportional to the partial pressure of oxygen, a quantitative measure of pressure change may be obtained using a silicon target vidicon or a charge-coupled device video sensor to measure intensity. Luminescent images are captured by a commercial frame buffer board. Images taken in wind tunnels during airflow are ratioed to images taken under ambient 'wind-off' conditions. The resulting intensity ratio information is converted to pressure using calibration curves of I0/I vs p/p0, where I0 is the intensity at ambient pressure p0 and I is the intensity at any other pressure p.

Kavandi, Janet↗

Surface temperature/heat transfer measurement using a quantitative phosphor thermography system

A relative-intensity phosphor thermography technique developed for surface heating studies in hypersonic wind tunnels is described. A direct relationship between relative emission intensity and phosphor temperature is used for quantitative surface temperature measurements in time. The technique provides global surface temperature-time histories using a 3-CCD (Charge Coupled Device) video camera and digital recording system. A current history of technique development at Langley is discussed. Latest developments include a phosphor mixture for a greater range of temperature sensitivity and use of castable ceramics for inexpensive test models. A method of calculating surface heat-transfer from thermal image data in blowdown wind tunnels is included in an appendix, with an analysis of material thermal heat-transfer properties. Results from tests in the Langley 31-Inch Mach 10 Tunnel are presented for a ceramic orbiter configuration and a four-inch diameter hemisphere model. Data include windward heating for bow-shock/wing-shock interactions on the orbiter wing surface, and a comparison with prediction for hemisphere heating distribution.

Buck, G. M.↗

GaAs CCD readout for engineered bandgap detectors

GaAs and related heterostructure charge-coupled devices (CCDs) for detector array readout multiplexer applications are described. Features of resistive-gate CCDs are compared with capacitive-gate CCDs for this application. Design examples of GaAs CCD readouts for linear and two-dimensional detector arrays with different detection methods and signal coupling schemes are described. Recent progress in two-dimensional electron gas (2DEG) Al(0.3)Ga(0.7)As/GaAs resistive-gate CCDs is also presented. The 2DEG resistive-gate CCD conventional buried-channel GaAs CCD.

Song, J.-I.↗

Effects of transistor geometry on CCD output sensitivity

This paper discusses recent progress in the understanding of the fabrication of low noise floating diffusion output amplifiers for special purpose charge-coupled devices. Emphasis has been given to reducing the total node capacitance and increasing the output sensitivity. Measurements of noise on experimental devices has yielded noise less than 3 electrons rms at 50 kpixel data rate.

Kim, H.↗

Microcontrollers Generate Timing Signals For CCD Arrays

Microcontrollers generate timing signals for charge-coupled-device array detectors in electronic system developed to test such detectors. With microcontroller, one changes timing signals via software, without changes in wiring. Approach more flexible, timing signals changed easier and quicker.

Hostetter, Marilyn K.↗

Gain, Level, And Exposure Control For A Television Camera

Automatic-level-control/automatic-gain-control (ALC/AGC) system for charge-coupled-device (CCD) color television camera prevents over-loading in bright scenes using technique for measuring brightness of scene from red, green, and blue output signals and processing these into adjustments of video amplifiers and iris on camera lens. System faster, does not distort video brightness signals, and built with smaller components.

Major, Geoffrey J.↗

Cameras Would Withstand High Accelerations

Very rugged cameras with all-reflective optics proposed for use in presence of high accelerations. Optics consist of four coaxial focusing mirrors in Cassegrain configuration. Mirrors are conics or aspherics. Optics achromatic,and imaging system overall passes light from extreme ultraviolet to far infrared. Charge-coupled-device video camera, film camera, or array of photodetectors placed at focal plane. Useful as portable imagers subject to rough handling, or instrumentation cameras mounted on severely vibrating or accelerating vehicles.

Meinel, Aden B.↗

Compact Visible And Infrared Spectrometer

New compact spectrometers operate over broad wavelength ranges with moderate spectral resolution. Prototype measures spectral intensity simultaneously at all wavelengths from 3,700 to 11,700 Angstrom, with resolution of 12 Angstrom. Spectrum imaged onto strips on photocathode, then coupled via fiber-optic taper onto charge-coupled-device imager. Suitable for observation of weak phenomena as nocturnal airglow, and for observation of bright auroras and dayglow.

Torr, Marsha R.↗

Tracking Comb Filter Suppresses Welder Harmonics

Tracking comb filter includes charge-coupled-device delay line and phase-locked loop. Filter removes harmonics of frequency of repetition of welding-current pulses from acoustic-emission signal. Spurious signals reduced almost to fundamental limit.

Delcher, Ray C.↗

Cometary spectroscopy and imaging

The objective is to investigate the spectroscopic and morphological characteristics of comets and selected minor planets over a wide range of heliocentric distances as they may suggest or constrain models of cometary processes, their formation environments and evolution. Direct images of all observable comets and 300-800 nm spectra of the brighter ones are obtained on a monthly basis with a charge coupled device spectrograph-camera. The direct images may be used for astrometry, photometry, and studies of coma and tail morphology. In some cases, anisotropic dust emission can provide information on the nucleus spin vector. Spectra may provide data on strengths of the principle emission for comparison of gas/dust ratios of a large sample of comets. Long integrations of minor planets in comet-like and nearby orbits are made to search for faint comae.

Larson, Stephen M.↗

Astrometric observations of comets and asteroids and subsequent orbital investigations

The transformation of the Oak Ridge astrometry from a photographic program to a charge coupled device (CCD) program can now be considered complete, and the number of observations being made is now approaching an order of magnitude greater than in the old photographic program. Astrometric observations with the 1.5-m reflector were made at the Oak Ridge Observatory, and the progress, accomplishments, and projected accomplishments are presented.

Marsden, B. G.↗

Observational evidence of aging processes in comets

Emphasis was on searching for systematic differences among two groups of comets: periodic comets which spend most of their time in the vicinity of the inner Solar System and the new comets which are believed to be passing through the inner Solar System for the first time. Such differences are expected, but have never been observed, in part because there has never been a systematic observational program aimed at addressing this question. Understanding possible physical and compositional differences between these two groups will lead to a better understanding of the cometary formation conditions in the early Solar System. The employed method studies the activity in the comets as a function of distance by obtaining charge coupled device (CCD) observations of the comets at frequent intervals on both the pre- and post-perihelion legs of their orbits in order to ascertain the distances at the onset and turn-off of activity through comparison with sublimation models.

Meech, Karen J.↗

Physical processes in comets

Post-Halley comets are known to be irregular objects with most nucleus activity very localized and with the dust coma capable of fragmentation and apparently being a source of gas. Older, 1-D strategies which assume steady isotropic outflow of material can give poor time-and-space averaged results, at best. With 2-D data, images through interference filters, it is hoped that: dust structures can be seen that give evidence of the proper geometry for data reduction; gradients along the axes of symmetry and evidence of fragmentation can be studied; and that evidence for gas abundance gradients associated with the dust can be found. High quality data from brighter comets can then be used to suggest improved data reduction procedures for fainter ones. To obtain such data, large image-quality interference filters were procured for use with a charge coupled device (CCD) camera at Lick Observatory, where the scale of the 1 m Nickel reflector is ideal for brighter comets. Whenever possible, data is taken simultaneously with other telescopes and equipment, especially spectroscopy at the Lick 3 m or infrared photometry at the Infrared Telescope Facility (IRTF) on Mauna Kea.

Newburn, Ray L., Jr.↗

Imaging studies of comets

The Joint Observatory for Cometary Research's (JOCR) historical mission has been to provide understanding of large-scale interactions between bright comets and solar wind using wide-angle (Schmidt) imagery and spacecraft data; in this pursuit the JOCR has excelled. The 16 inch Newtonian/Cassegrain telescope was upgraded to permit filtered, narrow-field charge coupled device (CCD) imaging of both bright and faint comets. Thus, the goal of obtaining narrow-band imagery of the near-nuclear region of bright comets was added to JOCR's original mission with emphasis on ionization processes and total gas production. A 300 mm lens/CCD system exists with 3 degree field of view (FOV) which uses comet filters; this system bridges the gap between the wide-field (8 x 10 deg) Schmidt plates and the several-arcmin. field of the 16 inch telescope. JOCR is located under dark skies on South Baldy Mountain (el. 10,600 ft.) near Socorro, NM, and is one of the last truly dark sites in the continental U.S.

Niedner, Malcolm B., Jr.↗

Ground-based observations of comets, the Jupiter plasma Torus, and Io

Aspects of cometary and magnetospheric physics were investigated by means of ground-based astronomical spectroscopy. High-throughput, dual-etalon Fabry-Perot spectrometers were used to obtain very high resolution spectra of atomic, molecular, and ionic emission lines from the diffuse gases and plasmas associated with comets and the Jupiter plasma torus. The Fabry-Perot spectrometers were also used with a charge coupled device (CCD) camera to obtain images of these extended emission sources in individual spectral lines at high spectral resolution. A new program using the McMath solar-stellar spectrograph to observe emission lines from Io was recently initiated. The McMath spectrograph has a high resolution mode which allows the detection of narrow, relatively faint emission lines superimposed on Io's reflected solar spectrum.

Scherb, Frank↗