Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Certified”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

6-Shogaol induces caspase-independent paraptosis in cancer cells via proteasomal inhibition

Highlights: • 6-Shogaol induced cytoplasmic vacuolation and death in breast and lung cancer cells. • Absence of caspase cleavage and DNA fragmentation proves its non-apoptotic nature. • Persistence of death in presence of autophagic inhibitors certifies it to be non-autophagic cell death. • It is found to inhibit the proteasome by binding to the β5 chymotrypsin subunit. • 6-Shogaol increases level of ER stress markers like Bip and CHOP in treated cancer cells. An α, β-unsaturated carbonyl compound of ginger, 6-Shogaol (6S), induced extensive cytoplasmic vacuolation and cell death in breast cancer cell (MDA-MB-231) and non-small lung cancer (A549) cells. In the presence of autophagic inhibitors the cells continued to exhibit cytoplasmic vacuolation and cell death clearly distinguishing it from the classic autophagic process. 6S induced death did not exhibit the characteristic apoptotic features like caspase cleavage, phosphatidyl serine exposure and DNA fragmentation. The immunofluorescence with the Endoplasmic Reticulum (ER) resident protein, calreticulin indicated that the vacuoles were of ER origin, typical of paraptosis. This was supported by the increase in level of microtubule associated protein light chain 3B (LC3 I and LC3 II) and polyubiquitin binding protein, p62. The level of ER stress markers like polyubiquitinated proteins, Bip and CHOP also consistently increased. We have found that 6S inhibits the 26S proteasome. The proteasomal inhibitory activity was elucidated by a) molecular docking of 6S onto the active site of β5 subunit and b) reduced fluorescence by the fluorogenic substrate of the chymotrypsin-like subunit. In conclusion these studies demonstrate for the first time that proteasomal inhibition by 6S induces cell death via paraptosis. So 6-shogaol may act as a template for anti-cancer lead discovery against the apoptosis resistant cancer cells.

60 APPLIED LIFE SCIENCES↗

ESR1 mediated circ{sub 0}004018 suppresses angiogenesis in hepatocellular carcinoma via recruiting FUS and stabilizing TIMP2 expression

Angiogenesis has been certified to account for tumor pathobiology. Circular RNAs (circRNAs) have been demonstrated to be involved in angiogenesis-related diseases, including hepatocellular carcinoma (HCC). Nevertheless, the regulatory roles of most circRNAs remain obscure. This study aims to uncover the function of hsa{sub c}irc{sub 0}004018 on angiogenesis in HCC. Firstly, quantitative real-time RT-PCR (RT-qPCR) analyzed that circ{sub 0}004018 was definitely down-regulated in HCC. Western blot analysis was conducted to detect the protein level of fused protein in sarcoma (FUS) and TIMP metallopeptidase inhibitor 2 (TIMP2). Functional assays were carried out to assess the impacts of circ{sub 0}004018 on HCC. From the experimental results, we found that overexpression of circ{sub 0}004018 significantly inhibited angiogenesis in HCC. The regulatory mechanism of circ{sub 0}004018 in HCC was determined by chromatin immunoprecipitation (ChIP), luciferase reporter assays and RNA immunoprecipitation (RIP) assay. Therefore, we proved that estrogen receptor 1 (ESR1) mediated circ{sub 0}004018 regulated TIMP2 by recruiting FUS. A series of rescue assays verified that circ{sub 0}004018 participated in angiogenesis in HCC via modulating TIMP2. In summary, this paper disclosed that ESR1 activated circ{sub 0}004018 inhibited angiogenesis in HCC via binding to FUS and stabilizing TIMP2 expression.

60 APPLIED LIFE SCIENCES↗

Determination of halogens in coal after digestion using the microwave-induced combustion technique

The microwave-induced combustion (MIC) technique was applied for coal digestion and further determination of bromide, chloride, fluoride, and iodide by ion chromatography (IC). Samples (up to 500 mg) were combusted at 2 MPa of oxygen. Combustion was complete in less than 50 s, and analytes were absorbed in water or (NH{sub 4}){sub 2}CO{sub 3} solution. A reflux step was applied to improve analyte absorption. Accuracy was evaluated for Br, Cl, and F using certified reference coal and spiked samples for I. For Br, Cl, and F, the agreement was between 96 and 103% using 50 mmol L{sup -1} (NH{sub 4}){sub 2}CO{sub 3} as the absorbing solution and 5 min of reflux. With the use of the same conditions, the recoveries for I were better than 97%. Br, Cl, and I were also determined in MIC digests by inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, and F was determined by an ion-selective electrode with agreement better than 95% to the values obtained using IC. Temperature during combustion was higher than 1350 {sup o}C, and the residual carbon content was lower than 1%. With the use of the MIC technique, up to eight samples could be processed simultaneously, and a single absorbing solution was suitable for all analytes and determination techniques (limit of detection by IC was better than 3 {mu} g g{sup -1} for all halogens).

01 COAL, LIGNITE, AND PEAT↗

Multiple stirred-flow chamber assembly for simultaneous automatic fractionation of trace elements in fly ash samples using a multisyringe-based flow system

There is a current trend in automation of leaching tests for trace elements in solid matrixes by use of flow injection based column approaches. However, as a result of the downscaled dimensions of the analytical manifold and execution of a single extraction at a time, miniaturized flow-through column approaches have merely found applications for periodic investigations of trace element mobility in highly homogeneous environmental solids. A novel flow-based configuration capitalized on stirred-flow cell extraction is proposed in this work for simultaneous fractionation of trace elements in three solid wastes with no limitation of sample amount up to 1.0 g. A two-step sequential extraction scheme involving water and acetic acid (or acetic acid/acetate buffer) is utilized for accurate assessment of readily mobilizable fractions of trace elements in fly ash samples. The W automated extraction system features high tolerance to flow rates ({<=} 6 mL min{sup -1}) and, as opposed to operationally defined batchwise methods, the solid to liquid ratio is not a critical parameter for, determination of overall readily leachable trace elements provided that exhaustive extraction is ensured. Analytical performance of the dynamic extractor is evaluated for fractionation analysis of a real coal fly ash and BCR-176R fly ash certified reference material. No significant differences were found at the 0.05 significance level between summation of leached concentrations in each fraction plus residue and concentration values of BCR-176R, thus revealing the accuracy of the automated method. Overall extractable pools of trace metals in three samples are separated in less than 115 min, even for highly contaminated ashes, versus 18-24 h per fraction in equilibrium leaching tests. The multiple stirred-flow cell assembly is thus suitable for routine risk assessment studies of industrial solid byproduct.

01 COAL, LIGNITE, AND PEAT↗

Determination of elemental constituents in different matrix materials and flow injection studies by the electrolyte cathode glow discharge technique with a new design

An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is evaluated. The optimized molarity of the solution is 0.2 M. The analytical response curves for Ca, Cu, Cd, Pb, Hg, Fe, and Zn demonstrated good linearity. The limit of detections of Ca, Cu, Cd, Pb, Hg, Fe, and Zn are determined to be 17, 11, 5, 45, 15, 28, and 3 ng mL{sup -1}. At an integration time of 0.3 s, the relative standard deviation (RSD) values of the acid blank solutions are found to be less than 10% for the elements Ca, Cu, Cd, Hg, Fe, and Zn and 18% for Pb. The method is applied for the determination of the elemental constituents in different matrix materials such as tuna fish (IAEA-350), oyster tissue (NIST SRM 1566a), and coal fly ash (CFA SRM 1633b). The obtained results are in good agreement with the certified values. The accuracy is found to be between 7% and 0.6% for major to trace levels of constituent elements and the precision between 11% and 0.6%. For the injection of 100 {mu} L of 200 ng mL{sup -1} mercury solution at the flow rate of 0.8 mL/min, the flow injection studies resulted in the relative standard deviation (RSD) of 8%, concentration detection limit of 10 ng/mL, and mass detection limit of 1 ng for mercury.

01 COAL, LIGNITE, AND PEAT↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry

A fully automated method for the separation of low-concentration uranium from plutonium in environmental swipe samples has been developed. The offline chromatography system features renewable 1 mL Eichrom TEVA and UTEVA column generation from bulk resin slurry. Discrete fractions of the separated actinides are delivered into user defined vials for future analysis. Clean room background levels were achieved outside of a cleanroom environment with this method. Purification of uranium and plutonium from various sample matrixes and at various concentrations was successful. Major and minor isotope ratios for both elements were measured via multiple collector inductively coupled plasma mass spectrometry and were in good agreement with certified reference values. Lastly, validation of the separation method was conducted on archived environmental samples and agreed with values previously reported using standard column chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relationship between the Chemiluminescence Intensity Ratio of C 2 * and CH*, Charge Pressure, and Equivalence Ratio for Gasoline

This work presents the results of an intensity-based fuel–air calibration for a range of charge pressures for gasoline fuel. The radical intensity ratio of diatomic carbon (C 2 *) to methylidene (CH*) was acquired through line-of-sight chemiluminescence imaging at pressures up to 10 bar. Certified gasoline (99% iso-octane, 0.9% n-heptane, and 0.1% other additives) and air are injected into an optically accessible pressure vessel capable of handling pressures up to 200 bar and ignited with an automotive spark plug. Line-of-sight images of C 2 * and CH* are recorded simultaneously on a single image sensor utilizing an intensifier, a high-speed camera, and various optical components to split the light signals associated with C 2 * and CH* (centered at 513 and 427 nm, respectively). The ratio of the signals (C 2 */CH*) are acquired and compared to the measured equivalence ratio of the exhaust gases and charge pressure. The approach allowed for characterization of the behavior of the intensity ratio at various charge pressures for gasoline. Here, the comparison of the intensity ratio (C 2 */CH*), equivalence ratio, and charge pressure resulted in the generation of a correlation map that can be used to calculate equivalence ratio if intensity ratio and charge pressure are known.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Analytical Methods for the Determination of Uranium in Seawater Using Inductively Coupled Plasma Mass Spectrometry

Trace element determinations in seawater by inductively coupled plasma mass spectrometry are analytically challenging due to the typically very low concentrations of the trace elements and the potential interference of the salt matrix. In this study, we did a comparison for uranium analysis using inductively coupled plasma mass spectrometry (ICP-MS) of Sequim Bay seawater samples and three seawater certified reference materials (SLEW-3, CASS-5 and NASS-6) using seven different analytical approaches. The methods evaluated include: direct analysis, Fe/Pd reductive precipitation, standard addition calibration, online automated dilution using an external calibration with and without matrix matching, and online automated pre-concentration. The method which produced the most accurate results was the method of standard addition calibration, recovering uranium from a Sequim Bay seawater sample at 101 ± 1.2%. The on-line preconcentration method and the automated dilution with matrix-matched calibration method also performed well. The two least effective methods were the direct analysis and the Fe/Pd reductive precipitation using sodium borohydride

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emergent Electronic and Dielectric Properties of Interacting Nanoparticles at Finite Temperature

Lead chalcogenide nanoparticle solids have been successfully integrated into certified solar cells and represent promising platforms for the design of novel photoabsorbers for photoelectrochemical cells. While much attention has been drawn to improving efficiency and device performance through altering the character of the individual nanoparticles, the role of interactions between nanoparticles is not yet well-understood. Using first-principles molecular dynamics and electronic structure calculations, we investigated the combined effect of temperature and interaction on functionalized lead chalcogenide nanoparticles (NPs). Here, we show that at finite temperature, interacting NPs are dynamical dipolar systems, with the average values of dipole moments and polarizabilities substantially increased with respect to those of the isolated building blocks. In addition, we show that the interacting NPs exhibit slightly smaller fundamental gaps that decrease as a function of temperature and that the radiative lifetimes of both the isolated NPs and the solids are greatly reduced at finite temperature compared to T = 0. Lastly, we present a critical discussion of various results reported in the literature for the values of dipole moments of nanoparticles.

36 MATERIALS SCIENCE↗

Package Development for Reliability Testing of Perovskites

Metal halide perovskite solar cells have reached a critical point in their development. At a current certified record efficiency of 25.7% for a single-junction, research-scale cell, they now garner serious attention from the solar cell industry as a promising route to widespread, low-cost photovoltaics in single- or tandem-junction configurations. However, more work to demonstrate their durability under real-world outdoor test conditions is necessary to ensure the long-term success and deployment of the technology. Differences in chemistry, processes, and their combination result in unique performance limiters for both efficiency and stability. Further, as many active formulations and layer/cell stack combinations are sensitive to temperature, air, and moisture, it is important to separate intrinsic limitations to stability relative to these extrinsic sources. This presents a particular need for the development of an appropriate and reliable package for environmental (i.e., accelerated and outdoor) testing that will permit these different factors to be evaluated and understood.

14 SOLAR ENERGY↗

High-Performance CuInS 2 Quantum Dot Laminated Glass Luminescent Solar Concentrators for Windows

Building-integrated sunlight harvesting utilizing laminated glass luminescent solar concentrators (LSCs) is proposed. By incorporating high quantum yield (>90%), NIR-emitting CuInS 2 /ZnS quantum dots into the polymer interlayer between two sheets of low-iron float glass, a record optical efficiency of 8.1% is demonstrated for a 10 cm x 10 cm device that transmits ~44% visible light. After completing prototypes by attaching silicon solar cells along the perimeter of the device, the electrical power conversion efficiency was certified at 2.2% with a black background and at 2.9% using a reflective substrate. This 'drop-in' LSC solution is particularly attractive because it fits within the existing glazing industry value chain with only modest changes to typical glazing products. Performance modeling predicts >1 GWh annual electricity production for a typical urban skyscraper in most major U.S. cities, enabling significant energy cost savings and potentially 'net-zero' buildings.

14 SOLAR ENERGY↗

Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45 min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

59 BASIC BIOLOGICAL SCIENCES↗

Constraining a Historical Black Carbon Emission Inventory of the United States for 1960–2000

Abstract We present an observationally constrained United States black carbon emission inventory with explicit representation of activity and technology between 1960 and 2000. We compare measured coefficient of haze data in California and New Jersey between 1965 and 2000 with predicted concentration trends and attribute discrepancies between observations and predicted concentrations among several sources based on seasonal and weekly patterns in observations. Emission factors for sources with distinct fuel trends are then estimated by comparing fuel and concentration trends and further substantiated by in‐depth examination of emission measurements. We recommend (1) increasing emission factors for preregulation vehicles by 80–250%; (2) increasing emission factors for residential heating stoves and boilers by 70% to 200% for 1980s and before; (3) explicitly representing naturally aspired off‐road engines for 1980s and before; and (4) explicitly representing certified wood stoves after 1985. We also evaluate other possible sources for discrepancy between model and measurement, including bias in modeled meteorology, subgrid spatial heterogeneity of concentrations, and inconsistencies in reported fuel consumption. The updated U.S. emissions are higher than the a priori estimate by 80% between 1960 and 1980, totaling 690 Gg/year in 1960 and 620 Gg/year in 1970 (excluding open burning). The revised inventory shows a strongly decreasing trend that was present in the observations but missing in the a priori inventory.

Sun, T.↗

Photo-induced halide redistribution in organic–inorganic perovskite films

Organic-inorganic perovskites such as CH 3 NH 3 PbI 3 are promising materials for a variety of optoelectronic applications, with certified power conversion efficiencies in solar cells already exceeding 21%. Nevertheless, state-of-the-art films still contain performance-limiting non-radiative recombination sites and exhibit a range of complex dynamic phenomena under illumination that remain poorly understood. Here we use a unique combination of confocal photoluminescence (PL) microscopy and chemical imaging to correlate the local changes in photophysics with composition in CH 3 NH 3 PbI 3 films under illumination. We demonstrate that the photo-induced 'brightening' of the perovskite PL can be attributed to an order-of-magnitude reduction in trap state density. By imaging the same regions with time-of-flight secondary-ion-mass spectrometry, we correlate this photobrightening with a net migration of iodine. In conclusion, our work provides visual evidence for photo-induced halide migration in triiodide perovskites and reveals the complex interplay between charge carrier populations, electronic traps and mobile halides that collectively impact optoelectronic performance.

36 MATERIALS SCIENCE↗