Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORRECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Universality (beyond leading log) of soft radiative corrections to $\hat q$ in $p_\perp$ broadening and energy loss

It has been known for many years that soft radiation can give potentially large double-logarithm corrections to $p_\perp$ broadening of a high-energy particle traveling through QCD matter, but that this soft radiation correction can be absorbed into an effective value $\hat q_{eff}$ for the medium $p_\perp$-broadening parameter $\hat q$. Here ``soft'' means high energy compared to medium scales but soft compared to the original high-energy particle traveling through the medium. A similar situation arises in the case of soft corrections to hard splitting of a high-energy particle, such as hard g → gg, where double logarithms can also be absorbed using the same effective $\hat q_{eff}$. In this paper, I study whether the same holds true for potentially large, subleading, {\it single}-logarthim corrections. The correspondence is more indirect for single logarithms, but I show (in the large-$N_c$ limit) that single logarithms from soft radiation in the case of $p_\perp$ broadening also determine the single logarithms from soft radiative corrections to hard g → gg splitting. Along the way, there is an interesting variation of the original BDMPS-Z calculation of splitting rates in the q(hat) approximation. I also discuss how, for soft-radiative corrections to hard splitting processes, there are two different types of ''$\hat q_{eff}$'' that come into play, which differ by ''$i\pi$'' terms that multiply single logarithms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiative corrections relating leptoquark-fermion couplings probed at low and high energy

Scalar leptoquarks (LQ) with masses between 2 TeV and 50 TeV are prime candidates to explain deviations between measurements and Standard-Model predictions in decay observables of b-flavored hadrons (“flavor anomalies”). Explanations of low-energy data often involve $\mathcal{O}$ (1) LQ-quark-lepton Yukawa couplings, especially when collider bounds enforce a large LQ mass. This calls for the calculation of radiative corrections involving these couplings. Studying such corrections to LQ-mediated b → cτν and b → sℓ + ℓ − amplitudes, we find that they can be absorbed into finite renormalizations of the LQ Yukawa couplings. If one wants to use Yukawa couplings extracted from low-energy data for the prediction of on-shell LQ decay rates, one must convert the low-energy couplings to their high-energy counterparts, which subsume the corrections to the on-shell LQ-quark-lepton vertex. We present compact formulae for these correction factors and find that in scenarios with S 1 , R 2 , or S 3 LQ the high-energy coupling is always smaller than the low-energy one, which weakens the impact of collider data on the determination of the allowed parameter spaces. For the R 2 scenario addressing b → cτν, in which one of the two involved Yukawa coupling must be significantly larger than 1, we find this coupling reduced by 15% at high energy. If both S 1 and R 2 are present, the high-energy coupling can also be larger and the size of the correction is unbounded, because tree contribution and vertex corrections involve different couplings. We further present the conversion formula to the $\overline{MS}$ scheme for the Yukawa couplings of the S 3 scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new approach to cosmogenic corrections in 40 Ar/ 39 Ar chronometry: Implications for the ages of Martian meteorites

Anomalously old 40 Ar/ 39 Ar ages are commonly obtained from Shergottites and are generally attributed to uncertainties regarding the isotopic composition of the trapped component and/or the presence of excess 40 Ar. Old ages can also be obtained if inaccurate corrections for cosmogenic 36 Ar are applied. Current methods for making the cosmogenic correction require simplifying assumptions regarding the spatial homogeneity of target elements for cosmogenic production and the distribution of cosmogenic nuclides relative to trapped and reactor-derived Ar isotopes. To mitigate uncertainties arising from these assumptions, a new cosmogenic correction approach utilizing the exposure age determined on an un-irradiated aliquot and step-wise production rate estimates that account for spatial variations in Ca and K is described. Data obtained from NWA 4468 and an unofficial pairing of NWA 2975, which yield anomalously old ages when corrected for cosmogenic 36 Ar using conventional techniques, are used to illustrate the efficacy of this new approach. For these samples, anomalous age determinations are rectified solely by the improved cosmogenic correction technique described herein. Ages of 188 ± 17 and 184 ± 17 Ma are obtained for NWA 4468 and NWA 2975, respectively, both of which are indistinguishable from ages obtained by other radioisotopic systems. For other Shergottites that have multiple trapped components, have experienced diffusive loss of Ar, or contain excess Ar, more accurate cosmogenic corrections may aid in the interpretation of anomalous ages. In conclusion, the trapped 40 Ar/ 36 Ar ratios inferred from inverse isochron diagrams obtained from NWA 4468 and NWA 2975 are significantly lower than the Martian atmospheric value, and may represent upper mantle or crustal components.

40Ar/39Ar↗

Viscosity Measurements at High Pressures: A Critical Appraisal of Corrections to Stokes' Law

Abstract Fluids and melts in planetary interiors significantly influence geodynamic processes from volcanism to global‐scale differentiation. The roles of these geofluids depend on their viscosities ( η ). Constraining geofluid η at relevant pressures and temperatures relies on laboratory‐based measurements and is most widely done using Stokes' Law viscometry with falling spheres. Yet small sample chambers required by high‐pressure experiments introduce significant drag on the spheres. Several correction schemes are available for Stokes' Law but there is no consensus on the best scheme(s) for high‐pressure experiments. We completed high‐pressure experiments to test the effects of (a) the relative size of the sphere diameter to the chamber diameter and (b) the top and bottom of the chamber, that is, the ends, on the sphere velocities. We examined the influence of current correction schemes on the estimated viscosity using Monte Carlo simulations. We also compared previous viscometry work on various geofluids in different experimental setups/geometries. We find the common schemes for Stokes' Law produce statistically distinct values of η . When inertia of the sphere is negligible, the most appropriate scheme may be the Faxén correction for the chamber walls. Correction for drag due to the chamber ends depends on the precision in the sinking distance and may be ineffective with decreasing sphere size. Combining the wall and end corrections may overcorrect η . We also suggest the uncertainty in η is best captured by the correction rather than propagated errors from experimental parameters. We develop an overlying view of Stokes' Law viscometry at high pressures.

Geochemistry & Geophysics↗

Experimental demonstration of continuous quantum error correction

The storage and processing of quantum information are susceptible to external noise, resulting in computational errors. A powerful method to suppress these effects is quantum error correction. Typically, quantum error correction is executed in discrete rounds, using entangling gates and projective measurement on ancillary qubits to complete each round of error correction. Here we use direct parity measurements to implement a continuous quantum bit-flip correction code in a resource-efficient manner, eliminating entangling gates, ancillary qubits, and their associated errors. An FPGA controller actively corrects errors as they are detected, achieving an average bit-flip detection efficiency of up to 91%. Furthermore, the protocol increases the relaxation time of the protected logical qubit by a factor of 2.7 over the relaxation times of the bare comprising qubits. Our results showcase resource-efficient stabilizer measurements in a multi-qubit architecture and demonstrate how continuous error correction codes can address challenges in realizing a fault-tolerant system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BeyondPlanck X. Bandpass and beam leakage corrections

We discuss the treatment of bandpass and beam leakage corrections in the Bayesian BeyondPlanck CMB analysis pipeline as applied to the Planck LFI measurements. As a preparatory step, we first apply three corrections to the nominal LFI bandpass profiles including removal of a known systematic effect in the ground measuring equipment at 61 GHz; smoothing of standing wave ripples; and edge regularization. The main net impact of these modifications is an overall shift in the 70 GHz bandpass of +0.6 GHz; we argue that any analysis of LFI data products, either from Planck or BeyondPlanck, should use these new bandpasses. In addition, we fit a single free bandpass parameter for each radiometer of the form Δ i = Δ 0 + $δ$ i , where Δ 0 represents an absolute frequency shift per frequency band and $δ$i is a relative shift per detector. The absolute correction is only fitted at 30 GHz with a full $\chi$ 2 -based likelihood, resulting in a correction of Δ 30 = 0.24 ± 0.03 GHz. The relative corrections are fitted using a spurious map approach, fundamentally similar to the method pioneered by the WMAP team, but without introducing many additional degrees of freedom. All bandpass parameters are sampled using a standard Metropolis sampler within the main BeyondPlanck Gibbs chain, and bandpass uncertainties are thus propagated to all other data products in the analysis. In total, we find that our bandpass model significantly reduces leakage effects. For beam leakage corrections, we adopt the official Planck LFI beam estimates without additional degrees of freedom, and only marginalize over the underlying sky model. We note that this is the first-time leakage from beam mismatch has been included for Planck LFI maps.

79 ASTRONOMY AND ASTROPHYSICS↗

A step in the direction of resolving the paradox of Perdew–Zunger self-interaction correction. II. Gauge consistency of the energy density at three levels of approximation

The Perdew-Zunger(PZ) self-interaction correction (SIC) was designed to correct the one-electron limit of any approximate density functional for the exchange-correlation (xc) energy, while yielding no correction to the exact functional. Unfortunately, it spoils the slowly-varying-in-space limits of the uncorrected approximate functionals, where those functionals are right by construction. The right limits can be restored by locally scaling down the energy density of the PZ SIC in many-electron regions, but then a spurious correction to the exact functional would be found unless the self-Hartree and exact self-xc terms of the PZ SIC energy density were expressed in the same gauge. Only the local density approximation satisfies the same-gauge condition for the energy density, which explains why the recent local-scaling SIC (LSIC) is found here to work excellently for atoms and molecules only with this basic approximation, and not with the more advanced generalized gradient approximations (GGAs) and meta-GGAs, which lose the Hartree gauge via simplifying integrations by parts. The transformation of energy density that achieves the Hartree gauge for the exact xc functional can also be applied to approximate functionals. Doing so leads to a simple scaled-down self-interaction (sdSIC) correction that is typically much more accurate than PZ SIC in tests for many molecular properties (including equilibrium bond lengths). The present work shows unambiguously that the largest errors of PZ SIC applied to standard functionals at three levels of approximation can be removed by restoring their correct slowlyvarying- density limits. Here, it also confirms the relevance of these limits to atoms and molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EMISSION CORRECTIONS FOR HYDROGEN FEATURES OF THE GRAVES ET AL. SLOAN DIGITAL SKY SURVEY AVERAGES OF EARLY-TYPE, NON-LINER GALAXIES

For purposes of recovering correct absorption line strengths for stellar population analysis, emission corrections for Balmer series indices on the Lick index system in Sloan Digital Sky Survey (SDSS) stacked quiescent galaxy spectra are derived as a function of the Mg b index strength. These corrections are obtained by comparing the observed Lick index measurements of the SDSS composite spectra with new observed measurements of 13 Virgo Cluster galaxies, and checked with model grids. From the H{alpha}-Mg b diagram, a linear correction for the observed measurement is constructed using best-fit trend lines. Corrections for H{beta}, H{gamma}, and H{delta} are constructed using stellar population models to predict continuum shape changes as a function of Mg b plus Balmer series emission intensities typical of H II regions. The corrections themselves are fairly secure, but the interpretation for H{delta} and H{gamma} indices is complicated by the fact that the H{delta} and H{gamma} indices are sensitive to elemental abundances other than hydrogen.

79 ASTRONOMY AND ASTROPHYSICS↗

Corrected entropy of Friedmann-Robertson-Walker universe in tunneling method

In this paper, we study the thermodynamic quantities of Friedmann-Robertson-Walker (FRW) universe by using the tunneling formalism beyond semiclassical approximation developed by Banerjee and Majhi [25]. For this we first calculate the corrected Hawking-like temperature on apparent horizon by considering both scalar particle and fermion tunneling. With this corrected Hawking-like temperature, the explicit expressions of the corrected entropy of apparent horizon for various gravity theories including Einstein gravity, Gauss-Bonnet gravity, Lovelock gravity, f(R) gravity and scalar-tensor gravity, are computed. Our results show that the corrected entropy formula for different gravity theories can be written into a general expression (4.39) of a same form. It is also shown that this expression is also valid for black holes. This might imply that the expression for the corrected entropy derived from tunneling method is independent of gravity theory, spacetime and dimension of the spacetime. Moreover, it is concluded that the basic thermodynamical property that the corrected entropy on apparent horizon is a state function is satisfied by the FRW universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Importance of finite-size corrections for accurate ab initio modeling of carrier capture at semiconductor defects: A case study of substitutional C N in GaN

In ab initio studies of carrier-capture processes in defective semiconductor materials, the single-effective-mode formalism and the static-coupling approximation have become the predominant theoretical approaches for determining carrier-capture coefficients. The single-mode formalism relies on accurate nonequilibrium defect energies obtained from density-functional theory (DFT), where required inputs are a series of configurationally displaced, defect-containing supercells obtained using an interpolative ansatz, and where the DFT outputs are corresponding total energies that have traditionally been postprocessed using a long-established ground-state formulation of finite-size corrections and defect-formation energies. This formulation remains commonly used even though the defects that form a configuration-coordinate (CC) diagram typically exist as structures that are displaced from the ground state. To remedy this inconsistency, Kumagai has recently proposed novel methods for implementing finite-size corrections specifically intended for DFT calculations of the defect energies used to construct CC diagrams and implement the single-mode formalism [Y. Kumagai, Phys. Rev. B 107, L220101 (2023)]. Kumagai's approach builds on the latest finite-size-correction methods introduced to describe vertical charge-state transitions for charge-localizing point defects in semiconductors and insulators [T. Gake et al., Phys. Rev. B 101, 020102 (2020); S. Falletta et al., Phys. Rev. B 102, 041115 (2020)]. The newly identified finite-size artifact treated in these studies is the polarization charge induced on a configurationally frozen defect and its subsequent interaction with a vertical transition in charge state. In this work, we evaluate Kumagai's proposed methodology by applying it in a high-precision DFT study of carrier capture by substitutional C N in GaN, a well-characterized and technologically relevant defect and material. We have rigorously calculated C N defect energies across various supercell sizes for each defect configuration and charge state on the hole-capture CC diagram of C N (𝑞=−1), enabling a direct comparison of the slopes of the defect energies versus inverse cell size with those predicted by Kumagai. The most consequential prediction of Kumagai's method is that these slopes distinctly vary as the square of the linear-interpolation parameter used to construct the nonequilibrium defect configurations. Our results quantitatively support this prediction. Moreover, with these new finite-size corrections and multiple-cell-size DFT calculations in place, we find that the classical energy barrier for hole capture by C N (𝑞=−1) in GaN decreases to 0.092–0.127 eV. This finding confirms the recent ≈ 0.1 eV prediction of Reshchikov based on the weak temperature dependence for hole capture observed in photoluminescence experiments [M. A. Reshchikov, J. Appl. Phys. 129, 121101 (2021)]. These results stand in stark contrast to previously calculated barriers of 0.486 and 0.73 eV, which also used the single-mode formalism but were obtained by instead using ground-state-based finite-size corrections. Our reduced classical barrier for capture increases the temperature-dependent hole-capture coefficient of a C N (𝑞=−1) defect by more than two to four orders of magnitude for temperatures of 100–600 K, compared to the previous 0.486 eV results. While other defects may not be as dramatically affected as here, we suggest that incorporating proper finite-size corrections for the vertical-transition-like states embedded within CC diagrams is an essential, yet previously unrecognized, component of accurate modeling of carrier-capture when using the single-effective-mode formalism.

dielectric properties↗

Better band gaps with asymptotically corrected local exchange potentials

In this study, we formulate a spin-polarized van Leeuwen and Baerends (vLB) correction to the local density approximation (LDA) exchange potential [R. van Leeuwen and E. J. Baerends, Phys. Rev. A 49, 2421 (1994)] that enforces the ionization potential (IP) theorem following T. Stein et al. [Phys. Rev. Lett. 105, 266802 (2010)]. For electronic-structure problems, the vLB correction replicates the behavior of exact-exchange potentials, with improved scaling and well-behaved asymptotics, but with the computational cost of semilocal functionals. The vLB + IP correction produces a large improvement in the eigenvalues over those from the LDA due to correct asymptotic behavior and atomic shell structures, as shown in rare-gas, alkaline-earth, zinc-based oxides, alkali halides, sulfides, and nitrides. In half-Heusler alloys, this asymptotically corrected LDA reproduces the spin-polarized properties correctly, including magnetism and half-metallicity. We also consider finite-sized systems [e.g., ringed boron nitride (B 12 N 12 ) and graphene (C 24 )] to emphasize the wide applicability of the method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Classical field approximation of ultralight dark matter: Quantum break times, corrections, and decoherence

The classical field approximation is widely used to better understand the predictions of ultralight dark matter. Here, in this work, we use the truncated Wigner approximation method to test the classical field approximation of ultralight dark matter. This method approximates a quantum state as an ensemble of independently evolving realizations drawn from its Wigner function. The method is highly parallelizable and allows the direct simulation of quantum corrections and decoherence times in systems many times larger than have been previously studied in reference to ultralight dark matter. Our study involves simulation of systems in 1, 2, and 3 spatial dimensions. We simulate three systems, the condensation of a Gaussian random field in three spatial dimensions, a stable collapsed object in three spatial dimensions, and the merging of two stable objects in two spatial dimensions. We study the quantum corrections to the classical field theory in each case. We find that quantum corrections grow exponentially during nonlinear growth with the timescale being approximately equal to the system dynamical time. In stable systems the corrections grow quadratically. We also find that the primary effect of quantum corrections is to reduce the amplitude of fluctuations on the de Broglie scale in the spatial density. Finally, we find that the timescale associated with decoherence due to gravitational coupling to baryonic matter is at least as fast as the quantum corrections due to gravitational interactions. These results are consistent with the predictions of the classical field theory being accurate.

79 ASTRONOMY AND ASTROPHYSICS↗

Interplay of threshold resummation and hadron mass corrections in deep inelastic processes

We discuss hadron mass corrections and threshold resummation for deep-inelastic scattering lN-->l'X and semi-inclusive annihilation e + e - → hX processes, and provide a prescription how to consistently combine these two corrections respecting all kinematic thresholds. We find an interesting interplay between threshold resummation and target mass corrections for deep-inelastic scattering at large values of Bjorken x B . In semi-inclusive annihilation, on the contrary, the two considered corrections are relevant in different kinematic regions and do not affect each other. A detailed analysis is nonetheless of interest in the light of recent high precision data from BaBar and Belle on pion and kaon production, with which we compare our calculations. For both deep inelastic scattering and single inclusive annihilation, the size of the combined corrections compared to the precision of world data is shown to be large. Therefore, we conclude that these theoretical corrections are relevant for global QCD fits in order to extract precise parton distributions at large Bjorken x B , and fragmentation functions over the whole kinematic range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signs of nonmonotonic finite-volume corrections to 𝑔 𝐴

We study finite-volume (FV) corrections to determinations of 𝑔 𝐴 via lattice quantum chromodynamics (QCD) using analytic results and numerical analysis. We observe that 𝑆⁢𝑈⁡(2) heavy Baryon chiral perturbation theory does not provide an unambiguous prediction for the sign of the FV correction, which is not surprising when one also considers large-𝑁 𝑐 constraints on the axial couplings. We further show that nonmonotonic FV corrections are naturally allowed when one considers either including explicit Δ-resonance degrees of freedom or one works to higher orders in the chiral expansion. We investigate the potential impact of these FV corrections with a precision study of 𝑔 𝐴 using models of FV corrections that are monotonic and nonmonotonic. Using lattice QCD data that is approximately at the 1% level of precision, we do not see significant evidence of nonmonotonic corrections. Looking forward to the next phase of lattice QCD calculations, we estimate that calculations that are between the 0.1% and 1% level of precision may be sensitive to these FV artifacts. Finally, we present an update of the CalLat prediction of 𝑔 𝐴 in the isospin limit with subpercent precision, 𝑔$^{QCD}_{𝐴}$ = 1.2674⁢(96).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections

Abstract Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH 4 ) and nitrous oxide (N 2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N 2 O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N 2 O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N 2 O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N 2 O sensor was tested at a corn ( Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N 2 O EC fluxes showed excellent agreement with those made with static chambers ( m = 1.0 ± 0.3; r 2 = .96). More generally, we identified absorption lines for CO 2 and CH 4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.

47 OTHER INSTRUMENTATION↗

A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution: A cardiac phantom study

Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative method which corrects for the influences of these parameters using a linear moving cardiac phantom. Methods: On a robotic arm with artificial arteries with four calcifications of increasing density, a linear movement was applied between 0 and 120 mm/s (step of 10 mm/s). The phantom was scanned five times on 64-slice MDCT, DSCT, and EBT using a standard acquisition protocol. The average Agatston, volume, and mass scores were determined for each velocity, calcification, and scanner. Susceptibility to motion was quantified using a cardiac motion susceptibility (CMS) index. Resemblance to EBT and physical volume and mass was quantified using a {Delta} index. Results: Increasing motion artifacts were observed at increasing velocities on all scanners, with increasing severity from EBT to DSCT to 64-slice MDCT. The calcium score showed a linear dependency on motion from which a correction factor could be derived. This correction factor showed a linear dependency on the mean calcification density with a good fit for all three scoring methods and all three scanners (0.73{<=}R{sup 2}{<=}0.95). The slope and offset of this correction factor showed a linear dependency on temporal resolution with a good fit for all three scoring methods and all three scanners (0.83{<=}R{sup 2}{<=}0.98). CMS was minimal for EBT and increasing values were observed for DSCT and highest values for 64-slice MDCT. CMS was minimal for mass score and increasing values were observed for volume score and highest values for Agatston score. For all densities and scoring methods DSCT showed on average the closest resemblance to EBT calcium scores. When using the correction factor, CMS index decreased on average by 15% and {Delta} index decreased by 35%. Conclusions: Calcium scores determined on DSCT and 64-slice MDCT are highly susceptible to motion as compared to EBT. The mass score is less susceptible to motion compared to volume and Agatston score. Calcium scores determined on DSCT bear a closer resemblance to EBT obtained calcium scores than 64-slice MDCT. In addition, the calcium score is highly dependent on the average density of individual calcifications and the dependency of the calcium score on motion showed a linear behavior on calcification density. From these relations, a quantitative method could be derived which corrects the measured calcium score for the influence of linear motion, mean calcification density, and temporal resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scatter correction method for x-ray CT using primary modulation: Phantom studies

Purpose: Scatter correction is a major challenge in x-ray imaging using large area detectors. Recently, the authors proposed a promising scatter correction method for x-ray computed tomography (CT) using primary modulation. Proof of concept was previously illustrated by Monte Carlo simulations and physical experiments on a small phantom with a simple geometry. In this work, the authors provide a quantitative evaluation of the primary modulation technique and demonstrate its performance in applications where scatter correction is more challenging. Methods: The authors first analyze the potential errors of the estimated scatter in the primary modulation method. On two tabletop CT systems, the method is investigated using three phantoms: A Catphan(c)600 phantom, an anthropomorphic chest phantom, and the Catphan(c)600 phantom with two annuli. Two different primary modulators are also designed to show the impact of the modulator parameters on the scatter correction efficiency. The first is an aluminum modulator with a weak modulation and a low modulation frequency, and the second is a copper modulator with a strong modulation and a high modulation frequency. Results: On the Catphan(c)600 phantom in the first study, the method reduces the error of the CT number in the selected regions of interest (ROIs) from 371.4 to 21.9 Hounsfield units (HU); the contrast to noise ratio also increases from 10.9 to 19.2. On the anthropomorphic chest phantom in the second study, which represents a more difficult case due to the high scatter signals and object heterogeneity, the method reduces the error of the CT number from 327 to 19 HU in the selected ROIs and from 31.4% to 5.7% on the overall average. The third study is to investigate the impact of object size on the efficiency of our method. The scatter-to-primary ratio estimation error on the Catphan(c)600 phantom without any annulus (20 cm in diameter) is at the level of 0.04, it rises to 0.07 and 0.1 on the phantom with an elliptical annulus (30 cm in the minor axis and 38 cm in the major axis) and with a circular annulus (38 cm in diameter). Conclusions: On the three phantom studies, good scatter correction performance of the proposed method has been demonstrated using both image comparisons and quantitative analysis. The theory and experiments demonstrate that a strong primary modulation that possesses a low transmission factor and a high modulation frequency is preferred for high scatter correction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward correcting drift in target position during radiotherapy via computer-controlled couch adjustments on a programmable Linac

Purpose: Real-time tracking of respiratory target motion during radiation therapy is technically challenging, owing to rapid and possibly irregular breathing variations. The authors report on a method to predict and correct respiration-averaged drift in target position by means of couch adjustments on an accelerator equipped with such capability. Methods: Dose delivery is broken up into a sequence of 10 s field segments, each followed by a couch adjustment based on analysis of breathing motion from an external monitor as a surrogate of internal target motion. Signal averaging over three respiratory cycles yields a baseline representing target drift. A Kalman filter predicts the baseline position 5 s in advance, for determination of the couch correction. The method's feasibility is tested with a motion phantom programmed according to previously recorded patient signals. Computed couch corrections are preprogrammed into a research mode of an accelerator capable of computer-controlled couch translations synchronized with the motion phantom. The method's performance is evaluated with five cases recorded during hypofractionated treatment and five from respiration-correlated CT simulation, using a root-mean-squared deviation (RMSD) of the baseline from the treatment planned position. Results: RMSD is reduced in all 10 cases, from a mean of 4.9 mm (range 2.7-9.4 mm) before correction to 1.7 mm (range 0.7-2.3 mm) after correction. Treatment time is increased {approx}5% relative to that for no corrections. Conclusions: This work illustrates the potential for reduction in baseline respiratory drift with periodic adjustments in couch position during treatment. Future treatment machine capabilities will enable the use of 'on-the-fly' couch adjustments during treatment.

60 APPLIED LIFE SCIENCES↗