Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONNECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Floating device aligns blind connections

Panel-mounted connectors overcome the misalignment of blind connectors in electronic rack mounted equipment. The connector is free to move in the vertical direction by the action of a parallelogram mount. This freedom of motion maintains the guide pin hole centerline parallel to the guide pin centerline at all times.

Resel, J. E.↗

Contact-resistance test probes: A concept

Devices are used in inspection of contact resistance in plated connectors after assembly into cables. System permits rapid inspection of connectors when mating connectors or special apparatus are not available, and enables source of excessive resistance to be precisely determined.

Brooks, C. H.↗

A simple, efficient resistance soldering apparatus

Multiple resistance soldering device for attaching electric leads to multiple terminal block connectors uses power source with one terminal connected to working probe, and other terminal attached to connector carrying common pins for lead insertion. Mating of male and female connectors solders each lead to individual cup pin.

Vermillion, C. M.↗

Leak detection with expandable coatings

Developed and evaluated is a system for leak detection that can be easily applied over separable connectors and that expands into a bubble or balloon if a leak is present. This objective is accomplished by using thin films of Parafilm tape wrapped over connectors, which are then overcoated with a special formulation. The low yield strength and the high elongation of the envelope permit bubble formation if leakage occurs. This system is appropriate for welds and other hardware besides separable connectors. The practical limit of this system appears to be for leaks exceeding 0.000001 cc/sec. If this envelope is used to trap gases for mass spectrometer inspection, leaks in the range of ten to the minus 8th power cc/sec. may be detectable.

Source record↗

Plug-in integrated/hybrid circuit

Hybrid circuitry can be installed into standard round bayonet connectors, to eliminate wiring from connector to circuit. Circuits can be connected directly into either section of connector pair, eliminating need for hard wiring to that section.

Stringer, E. J.↗

Optical digital techniques

Optical interface losses between transmitter-to-fiber interface, connector-to-connector interface, and fiber-to-receiver interface were studied. System effects such as pulse dispersion, risetimes of the sources and detectors, type of fibers used, output power of the sources, and detector sensitivity were considered. Data bus systems such as TEE, Star, and Hybrid were analyzed. The matter of single fiber versus bundle technologies for future avionics systems was considered. The existing data bus system on Space Shuttle was examined and an optical analog was derived for a fiber bundle system, along with the associated power margin. System tests were performed on a feasibility model of a 9-port Star data bus system including BER, star losses, connector losses, etc. The same system was subjected to EMI between the range of 200 Hz to 10 GHz at 20V/m levels. A lightning test was also performed which simulated the conditions similar to those on Space Shuttle. The data bus system was found to be EMI and lightning hard. It is concluded that an optical data bus system is feasible for shuttle orbiter type vehicles.

Source record↗

Apparatus for adapting an end effector device remotely controlled manipulator arm

Apparatus for adapting a general purpose and effector device to a special purpose and effector is disclosed which includes an adapter bracket assembly which provides a mechanical and electrical interface between the end effector devices. The adapter bracket assembly includes an adapter connector post which interlocks with a diamond shaped gripping channel formed in closed jaws of the general purpose end effector. The angularly intersecting surfaces of the connector post and gripping channel prevent any relative movement there between. Containment webs constrain the outer finger plates of the general purpose jaws to prevent pitch motion. Electrical interface is provided by conical, self aligning electrical connector components carried by respective ones of said end effectors.

Clark, K. H.↗

Reliable Wiring Harness

New harness for electrical wiring includes plugs that do not loosen from vibration. Ground braids prevented from detaching from connectors and constrained so braids do not open into swollen "birdcage" sections. Spring of stainless steel encircles ground braid. Self-locking connector contains ratchet not only preventing connector from opening, but tightens when vibrated.

Gaspar, Kenneth C.↗

The mission configuration process for the Spartan attitude control system

The Spartan attitude control system (ACS) control electronics assembly cold plate has a standard connector interface to the rest of the Spartan payload and ground equipment. The connectors carry gyro signals, optical sensor signals, the experiment interface, the gas command decoder interface, and a pneumatics interface. Different flights can employ different optical sensor complements; the ACS engineer must accordingly connect the sensor error signals to the proper pins and connectors on the ACS electronics.

Stone, R. W.↗

Connection space reduction mechanism

A connector assembly comprised of two halves, each respectively including a shell type connector subassembly, one being an active half and the other being a passive half is described. The active half includes an alignment cusp that causes a coupling motion in response to coming in contact with the outer portion of the other half, which causes the respective connectors within the two subassemblies to move toward each other into coupling relationship at twice the rate at which the two subassemblies come together. Both halves are adapted to rotate about and translate along respective mutually orthogonal axes to facilitate an interconnection.

Milam, Malcolm Bruce↗

Performance experiments with alternative advanced teleoperator control modes for a simulated solar maximum satellite repair

Experiments are described which were conducted at the JPL Advanced Teleoperator Lab to demonstrate and evaluate the effectiveness of various teleoperator control modes in the performance of a simulated Solar Max Satellite Repair (SMSR) task. THe SMSR was selected as a test because it is very rich in performance capability requirements and it actually has been performed by two EVA astronauts in the Space Shuttle Bay in 1984. The main subtasks are: thermal blanket removal; installation of a hinge attachment for electrical panel opening; opening of electrical panel; removal of electrical connectors; relining of cable bundles; replacement of electrical panel; securing parts and cables; re-mate electrical connectors; closing of electrical panel; and reinstating thermal blanket. The current performance experiments are limited to thermal blanket cutting, electrical panel unbolting and handling electrical bundles and connectors. In one formal experiment even different control modes were applied to the unbolting and reinsertion of electrical panel screws subtasks. The seven control modes are alternative combinations of manual position and rate control with force feedback and remote compliance referenced to force-torque sensor information. Force-torque sensor and end effector position data and task completion times were recorded for analysis and quantification of operator performance.

Das, H.↗

Multiconductor Short/Open Cable Tester

Frequent or regular testing of multiconductor cables terminated in multipin conductors tedious, if not impossible, task. This inexpensive circuit simplifies open/short testing and is amenable to automation. In operation, pair of connectors selected to match pair of connectors installed on each of cables to be tested. As many connectors accommodated as required, and each can have as many conductors as required. Testing technique implemented with this circuit automated easily with electronic controls and computer interface. Printout provides status of each conductor in cable, indicating which, if any, of conductors has open or short circuit.

Eichenberg, Dennis↗

System for the installation and replacement of components in hostile environments

Service equipment for use in hostile environments is presented. The equipment includes a detachable service unit secured to a stationary service unit. The detachable service unit includes a housing with an exterior plate, a power control interface for connection to an exterior power source, locating pins located in said exterior plate, an electrical connector in the exterior plate electrically coupled to said power control interface, and a pair of clamping receptacles formed in the exterior plate and located on adjacent opposite edges of the exterior plate. The stationary unit includes an electrical connector for connection to the electrical connector of the detachable service unit, a clamping apparatus for clamping and unclamping the detachable service unit from the stationary unit, a base clamp assembly for mounting the clamping apparatus onto the stationary unit, and locating pin holes for receiving the locating pins and aligning the detachable service unit onto the stationary unit. The detachable service unit have mating scalloped faces which aid in alignment and provide a mechanism for heat dissipation.

Gordan, Andrew L.↗

Service equipment for use in hostile environments

Service equipment for use in hostile environments includes a detachable service unit secured to a stationary service unit. The detachable service unit includes a housing with an exterior plate, a power control interface for connection to an exterior power source, locating pins located in said exterior plate, an electrical connector in the exterior plate electrically coupled to said power control interface, and a pair of clamping receptacles formed in the exterior plate and located on adjacent opposite edges of the exterior plate. The stationary unit includes an electrical connector for connection to the electrical connector of the detachable service unit, a clamping apparatus for clamping and unclamping the detachable service unit from the stationary unit, a base clamp assembly for mounting the clamping apparatus onto the stationary unit, and locating pin holes for receiving the locating pins and aligning the detachable service unit onto the stationary unit. The detachable service unit and stationary unit have mating scalloped faces which aid in alignment and provide a mechanism for heat dissipation.

Dolce, James L.↗

Preload-Release Mechanism For Mounting Electronics Boxes

Proposed mechanism applies spring preload to electrical connector only while needed during insertion of electronics box into supporting frame. Once connector fully mated, mechanism relieves preload. As result, supporting structure sized to handle only individual load applied briefly by each connector on box during insertion.

Generoli, Robert M.↗

Method and Apparatus for Obtaining a Precision Thickness in Semiconductor and Other Wafers

A method and apparatus for processing a wafer comprising a material selected from an electrical semiconducting material and an electrical insulating material is presented. The wafer has opposed generally planar front and rear sides and a peripheral edge, wherein said wafer is pressed against a pad in the presence of a slurry to reduce its thickness. The thickness of the wafer is controlled by first forming a recess such as a dimple on the rear side of the wafer. A first electrical conducting strip extends from a first electrical connection means to the base surface of the recess to the second electrical connector. The first electrical conducting strip overlies the base surface of the recess. There is also a second electrical conductor with an electrical potential source between the first electrical connector and the second electrical connector to form. In combination with the first electrical conducting strip, the second electrical conductor forms a closed electrical circuit, and an electrical current flows through the closed electrical circuit. From the front side of the wafer the initial thickness of the wafer is reduced by lapping until the base surface of the recess is reached. The conductive strip is at least partially removed from the base surface to automatically stop the lapping procedure and thereby achieve the desired thickness.

Okojie, Robert S.↗

"Fly-by-Wireless": A Revolution in Aerospace Vehicle Architecture for Instrumentation and Control

Aerospace vehicle programs have always counted on the cables and connectors to provide power, grounding, data and time synchronization throughout a vehicle's life-cycle. Even with numerous improvements, wiring and connector problems and sensors continue to be key failure points, causing many hours of troubleshooting and replacement. Costly flight delays have been precipitated by the need to troubleshoot cables/connections, and/or repair a sensor. Wiring continues to be too expensive to remove once it is installed, even with the weight penalties. Miles of test instrumentation and low flight sensor wires still plague the aerospace industry. New technology options for data connectivity, processing and micro/nano manufacturing are making it possible to retrofit existing vehicles, like the Space Shuttle. New vehicles can now develop architectures that provide for and take advantage of alternatives to wired connectivity. This project motivates the aerospace industry and technology providers to establish: (1) A new emphasis for system engineering approaches to reduce cables and connectors. (2) Provisions for modularity and accessibility in the vehicle architecture. (3) A set of technologies that support alternatives to wired connectivity.

Studor, George↗