Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONE ALGORITHMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

WE-G-207-07: Iterative CT Shading Correction Method with No Prior Information

Purpose: Shading artifacts are caused by scatter contamination, beam hardening effects and other non-ideal imaging condition. Our Purpose is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT imaging (e.g., cone-beam CT, low-kVp CT) without relying on prior information. Methods: Our method applies general knowledge of the relatively uniform CT number distribution in one tissue component. Image segmentation is applied to construct template image where each structure is filled with the same CT number of that specific tissue. By subtracting the ideal template from CT image, the residual from various error sources are generated. Since the forward projection is an integration process, the non-continuous low-frequency shading artifacts in the image become continuous and low-frequency signals in the line integral. Residual image is thus forward projected and its line integral is filtered using Savitzky-Golay filter to estimate the error. A compensation map is reconstructed on the error using standard FDK algorithm and added to the original image to obtain the shading corrected one. Since the segmentation is not accurate on shaded CT image, the proposed scheme is iterated until the variation of residual image is minimized. Results: The proposed method is evaluated on a Catphan600 phantom, a pelvic patient and a CT angiography scan for carotid artery assessment. Compared to the one without correction, our method reduces the overall CT number error from >200 HU to be <35 HU and increases the spatial uniformity by a factor of 1.4. Conclusion: We propose an effective iterative algorithm for shading correction in CT imaging. Being different from existing algorithms, our method is only assisted by general anatomical and physical information in CT imaging without relying on prior knowledge. Our method is thus practical and attractive as a general solution to CT shading correction. This work is supported by the National Science Foundation of China (NSFC Grant No. 81201091), National High Technology Research and Development Program of China (863 program, Grant No. 2015AA020917), and Fund Project for Excellent Abroad Scholar Personnel in Science and Technology.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-02: An Electrostatic Model for Assessment of Joint Space Morphology in Cone-Beam CT

Purpose: High-resolution cone-beam CT (CBCT) of the extremities presents a potentially valuable basis for image-based biomarkers of arthritis, trauma, and risk of injury. We present a new method for 3D joint space analysis that exploits the high isotropic spatial resolution of CBCT and is sensitive to small changes in disease-related morphology. Methods: The approach uses an “electrostatic” model in which joint surfaces (e.g., distal femur and proximal tibia) are labeled as charge densities between which the electric field is solved by approximation to the Laplace equation. The method yields a unique solution determined by the field lines across the “capacitor” and is hypothesized to be more sensitive than conventional (Sharp) scores and immune to degeneracies that limit simple distance-along-axis or closest-point analysis. The algorithm was validated in CBCT phantom images and applied in two clinical scenarios: osteoarthritis (OA, change in loadbearing tibiofemoral joint space); and assessment of injury risk (correlation of 3D joint space to tibial slope). Results: Joint space maps computed from the electrostatic model were accurate to within the voxel size (0.26 mm). The method highlighted subtle regions of morphological change that would likely be missed by conventional scalar metrics. Regions of subtle cartilage erosion were well quantified, and the method confidently discriminated OA and non-OA cohorts. 3D joint space maps correlated well with tibial slope and provide a new basis for principal component analysis of loadbearing injury risk. Runtime was less than 5 min (235×235×121 voxel subvolume in Matlab). Conclusion: A new method for joint space assessment was reported as a possible image-based biomarker of subtle articular change. The algorithm yields accurate quantitation of the joint in a manner that is robust against operator and patient setup variation. The method shows promising initial results in ongoing trials of CBCT in osteoarthritis, rheumatoid arthritis, and injury risk assessment. Research supported by R01 and R21 grants from the National Institutes of Health, academic-industry partnership with Carestream Health, and a grant from the US Army Natick Soldier Research, Development and Engineering Center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging

Purpose: X-ray cone-beam CT (CBCT) is being increasingly used for various clinical applications, while its performance is still hindered by image artifacts. This work investigates a new source of reconstruction error, which is often overlooked in the current CBCT imaging. The authors find that the x-ray flat field intensity (I{sub 0}) varies significantly as the illumination volume size changes at different collimator settings. A wrong I{sub 0} value leads to inaccurate CT numbers of reconstructed images as well as wrong scatter measurements in the CBCT research. Methods: The authors argue that the finite size of x-ray focal spot together with the detector glare effect cause the I{sub 0} variation at different illumination sizes. Although the focal spot of commercial x-ray tubes typically has a nominal size of less than 1 mm, the off-focal-spot radiation covers an area of several millimeters on the tungsten target. Due to the large magnification factor from the field collimator to the detector, the penumbra effects of the collimator blades result in different I{sub 0} values for different illumination field sizes. Detector glare further increases the variation, since one pencil beam of incident x-ray is scattered into an area of several centimeters on the detector. In this paper, the authors study these two effects by measuring the focal spot distribution with a pinhole assembly and the detector point spread function (PSF) with an edge-spread function method. The authors then derive a formula to estimate the I{sub 0} value for different illumination field sizes, using the measured focal spot distribution and the detector PSF. Phantom studies are carried out to investigate the accuracy of scatter measurements and CT images with and without considering the I{sub 0} variation effects. Results: On our tabletop system with a Varian Paxscan 4030CB flat-panel detector and a Varian RAD-94 x-ray tube as used on a clinical CBCT system, the focal spot distribution has a measured full-width-at-half-maximum (FWHM) of around 0.4 mm, while non-negligible off-focal-spot radiation is observed at a distance of over 2 mm from the center. The measured detector PSF has an FWHM of 0.510 mm, with a shape close to Gaussian. From these two distributions, the author calculate the estimated I{sub 0} values at different collimator settings. The I{sub 0} variation mainly comes from the focal spot effect. The estimation matches well with the measurements at different collimator widths in both horizontal and vertical directions, with an average error of less than 3%. Our method improves the accuracy of conventional scatter measurements, where the scatter is measured as the difference between fan-beam and cone-beam projections. On a uniform water cylinder phantom, more accurate I{sub 0} suppresses the unfaithful high-frequency signals at the object boundaries of the measured scatter, and the SPR estimation error is reduced from 0.158 to 0.014. The proposed I{sub 0} estimation also reduces the reconstruction error from about 20 HU on the Catphan Copyright-Sign 600 phantom in the selected regions of interest to less than 4 HU. Conclusions: The I{sub 0} variation is identified as one additional error source in x-ray imaging. By measuring the focal-spot distribution and detector PSF, the authors propose an accurate method of estimating the I{sub 0} value for different illumination field sizes. The method obtains more accurate scatter measurements and therefore facilitates scatter correction algorithm designs. As correction methods for other CBCT artifacts become more successful, our research is significant in further improving the CBCT imaging accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-10: A Moving-Blocker-Based Strategy for Simultaneous Megavoltage and Kilovoltage Scatter Correction in Cone-Beam Computed Tomography Image Acquired During Volumetric Modulated Arc Therapy

Purpose: To evaluate a moving-blocker-based approach in estimating and correcting megavoltage (MV) and kilovoltage (kV) scatter contamination in kV cone-beam computed tomography (CBCT) acquired during volumetric modulated arc therapy (VMAT). Methods: XML code was generated to enable concurrent CBCT acquisition and VMAT delivery in Varian TrueBeam developer mode. A physical attenuator (i.e., “blocker”) consisting of equal spaced lead strips (3.2mm strip width and 3.2mm gap in between) was mounted between the x-ray source and patient at a source to blocker distance of 232mm. The blocker was simulated to be moving back and forth along the gantry rotation axis during the CBCT acquisition. Both MV and kV scatter signal were estimated simultaneously from the blocked regions of the imaging panel, and interpolated into the un-blocked regions. Scatter corrected CBCT was then reconstructed from un-blocked projections after scatter subtraction using an iterative image reconstruction algorithm based on constraint optimization. Experimental studies were performed on a Catphan 600 phantom and an anthropomorphic pelvis phantom to demonstrate the feasibility of using moving blocker for MV-kV scatter correction. Results: MV scatter greatly degrades the CBCT image quality by increasing the CT number inaccuracy and decreasing the image contrast, in addition to the shading artifacts caused by kV scatter. The artifacts were substantially reduced in the moving blocker corrected CBCT images in both Catphan and pelvis phantoms. Quantitatively, CT number error in selected regions of interest reduced from 377 in the kV-MV contaminated CBCT image to 38 for the Catphan phantom. Conclusions: The moving-blockerbased strategy can successfully correct MV and kV scatter simultaneously in CBCT projection data acquired with concurrent VMAT delivery. This work was supported in part by a grant from the Cancer Prevention and Research Institute of Texas (RP130109) and a grant from the American Cancer Society (RSG-13-326-01-CCE)

60 APPLIED LIFE SCIENCES↗

SU-E-I-11: A New Cone-Beam CT System for Bedside Head Imaging

Purpose: To design and develop a new mobile cone-beam CT (CBCT) system for head imaging with good soft-tissue visibility, to be used bedside in ICU and neurosurgery department to monitor treatment and operation outcome in brain patients. Methods: The imaging chain consists of a 30cmx25cm amorphous silicon flat panel detector and a pulsed, stationary anode monoblock x-ray source of 100kVp at a maximal tube current of 10mA. The detector and source are supported on motorized mechanisms to provide detector lateral shift and source angular tilt, enabling a centered digital radiographic imaging mode and half-fan CBCT, while maximizing the use of the x-ray field and keep the source to detector distance short. A focused linear anti-scatter grid is mounted on the detector, and commercial software with scatter and other corrective algorithms is used for data processing and image reconstruction. The gantry rotates around a horizontal axis, and is able to adjust its height for different patient table positions. Cables are routed through a custom protective sleeve over a large bore with an in-plane twister band, facilitating single 360-degree rotation without a slip-ring at a speed up to 5 seconds per rotation. A UPS provides about 10 minutes of operation off the battery when unplugged. The gantry is on locked casters, whose brake is control by two push handles on both sides for easy reposition. The entire system is designed to have a light weight and a compact size for excellent maneuverability. Results: System design is complete and main imaging components are tested. Initial results will be presented and discussed later in the presentation. Conclusion: A new mobile CBCT system for head imaging is being developed. With its compact size, a large bore, and quality design, it is expected to be a useful imaging tool for bedside uses. The work is supported by a grant from Chinese Academy of Sciences.

60 APPLIED LIFE SCIENCES↗

Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: First patient studies

Purpose: Quantitative cone-beam CT (CBCT) imaging is on increasing demand for high-performance image guided radiation therapy (IGRT). However, the current CBCT has poor image qualities mainly due to scatter contamination. Its current clinical application is therefore limited to patient setup based on only bony structures. To improve CBCT imaging for quantitative use, we recently proposed a correction method using planning CT (pCT) as the prior knowledge. Promising phantom results have been obtained on a tabletop CBCT system, using a correction scheme with rigid registration and without iterations. More challenges arise in clinical implementations of our method, especially because patients have large organ deformation in different scans. In this paper, we propose an improved framework to extend our method from bench to bedside by including several new components. Methods: The basic principle of our correction algorithm is to estimate the primary signals of CBCT projections via forward projection on the pCT image, and then to obtain the low-frequency errors in CBCT raw projections by subtracting the estimated primary signals and low-pass filtering. We improve the algorithm by using deformable registration to minimize the geometry difference between the pCT and the CBCT images. Since the registration performance relies on the accuracy of the CBCT image, we design an optional iterative scheme to update the CBCT image used in the registration. Large correction errors result from the mismatched objects in the pCT and the CBCT scans. Another optional step of gas pocket and couch matching is added into the framework to reduce these effects. Results: The proposed method is evaluated on four prostate patients, of which two cases are presented in detail to investigate the method performance for a large variety of patient geometry in clinical practice. The first patient has small anatomical changes from the planning to the treatment room. Our algorithm works well even without the optional iterations and the gas pocket and couch matching. The image correction on the second patient is more challenging due to the effects of gas pockets and attenuating couch. The improved framework with all new components is used to fully evaluate the correction performance. The enhanced image quality has been evaluated using mean CT number and spatial nonuniformity (SNU) error as well as contrast improvement factor. If the pCT image is considered as the ground truth, on the four patients, the overall mean CT number error is reduced from over 300 HU to below 16 HU in the selected regions of interest (ROIs), and the SNU error is suppressed from over 18% to below 2%. The average soft-tissue contrast is improved by an average factor of 2.6. Conclusions: We further improve our pCT-based CBCT correction algorithm for clinical use. Superior correction performance has been demonstrated on four patient studies. By providing quantitative CBCT images, our approach significantly increases the accuracy of advanced CBCT-based clinical applications for IGRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-12A-01: An Inter-Projection Interpolation (IPI) Approach for the Synchronized Moving Grid (SMOG) to Reduce Dose in Cone Beam CT

Purpose: Synchronized moving grid is a promising technique to reduce scatter and ghost artifacts in cone beam computed tomography (CBCT). However, it requires 2 projections in the same gantry angle to obtain full information due to signal blockage by the grid. We proposed an inter-projection interpolation (IPI) method to estimate blocked signals, which may reduce the scan time and the dose. This study aims to provide a framework to achieve a balance between speed, dose and image quality. Methods: The IPI method is based on the hypothesis that an abrupt signal in a projection can be well predicted by the information in the two immediate neighboring projections if the gantry angle step is small. The study was performed on a Catphan and a head phantom. The SMOG was simulated by erasing the information (filling with “0”) of the areas in each projection corresponding to the grid. An IPI algorithm was applied on each projection to recover the erased information. FDK algorithm was used to reconstruct CBCT images for the IPI-processed projections, and compared with the original image in term of signal to noise ratio (SNR) measured in the whole reconstruction image range. The effect of gantry angle step was investigated by comparing the CBCT images from projection sets of various gantry intervals, with IPI-predicted projections to fill the missing projection in the interval. Results: The IPI procession time was 1.79s±0.53s for each projection. SNR after IPI was 29.0db and 28.1db for the Catphan and head phantom, respectively, comparing to 15.3db and 22.7db for an inpainting based interpolation technique. SNR was 28.3, 28.3, 21.8, 19.3 and 17.3 db for gantry angle intervals of 1, 1.5, 2, 2.5 and 3 degrees, respectively. Conclusion: IPI is feasible to estimate the missing information, and achieve an reasonable CBCT image quality with reduced dose and scan time. This study is supported by NIH/NCI grant 1R01CA166948-01.

60 APPLIED LIFE SCIENCES↗

SU-F-J-41: Experimental Validation of a Cascaded Linear System Model for MVCBCT with a Multi-Layer EPID

Purpose: The purpose of this study was to validate the use of a cascaded linear system model for MV cone-beam CT (CBCT) using a multi-layer (MLI) electronic portal imaging device (EPID) and provide experimental insight into image formation. A validated 3D model provides insight into salient factors affecting reconstructed image quality, allowing potential for optimizing detector design for CBCT applications. Methods: A cascaded linear system model was developed to investigate the potential improvement in reconstructed image quality for MV CBCT using an MLI EPID. Inputs to the three-dimensional (3D) model include projection space MTF and NPS. Experimental validation was performed on a prototype MLI detector installed on the portal imaging arm of a Varian TrueBeam radiotherapy system. CBCT scans of up to 898 projections over 360 degrees were acquired at exposures of 16 and 64 MU. Image volumes were reconstructed using a Feldkamp-type (FDK) filtered backprojection (FBP) algorithm. Flat field images and scans of a Catphan model 604 phantom were acquired. The effect of 2×2 and 4×4 detector binning was also examined. Results: Using projection flat fields as an input, examination of the modeled and measured NPS in the axial plane exhibits good agreement. Binning projection images was shown to improve axial slice SDNR by a factor of approximately 1.4. This improvement is largely driven by a decrease in image noise of roughly 20%. However, this effect is accompanied by a subsequent loss in image resolution. Conclusion: The measured axial NPS shows good agreement with the theoretical calculation using a linear system model. Binning of projection images improves SNR of large objects on the Catphan phantom by decreasing noise. Specific imaging tasks will dictate the implementation image binning to two-dimensional projection images. The project was partially supported by a grant from Varian Medical Systems, Inc. and grant No. R01CA188446-01 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Dedicated breast CT: Fibroglandular volume measurements in a diagnostic population

Purpose: To determine the mean and range of volumetric glandular fraction (VGF) of the breast in a diagnostic population using a high-resolution flat-panel cone-beam dedicated breast CT system. This information is important for Monte Carlo-based estimation of normalized glandular dose coefficients and for investigating the dependence of VGF on breast dimensions, race, and pathology. Methods: Image data from a clinical trial investigating the role of dedicated breast CT that enrolled 150 women were retrospectively analyzed to determine the VGF. The study was conducted in adherence to a protocol approved by the institutional human subjects review boards and written informed consent was obtained from all study participants. All participants in the study were assigned BI-RADS{sup Registered-Sign} 4 or 5 as per the American College of Radiology assessment categories after standard diagnostic work-up and underwent dedicated breast CT exam prior to biopsy. A Gaussian-kernel based fuzzy c-means algorithm was used to partition the breast CT images into adipose and fibroglandular tissue after segmenting the skin. Upon determination of the accuracy of the algorithm with a phantom, it was applied to 137 breast CT volumes from 136 women. VGF was determined for each breast and the mean and range were determined. Pathology results with classification as benign, malignant, and hyperplasia were available for 132 women, and were used to investigate if the distributions of VGF varied with pathology. Results: The algorithm was accurate to within {+-}1.9% in determining the volume of an irregular shaped phantom. The study mean ({+-} inter-breast SD) for the VGF was 0.172 {+-} 0.142 (range: 0.012-0.719). VGF was found to be negatively correlated with age, breast dimensions (chest-wall to nipple length, pectoralis to nipple length, and effective diameter at chest-wall), and total breast volume, and positively correlated with fibroglandular volume. Based on pathology, pairwise statistical analysis (Mann-Whitney test) indicated that at the 0.05 significance level, there was no significant difference in distributions of VGF without adjustment for age between malignant and nonmalignant breasts (p= 0.41). Pairwise comparisons of the distributions of VGF in increasing order of mammographic breast density indicated all comparisons were statistically significant (p < 0.002). Conclusions: This study used a different clinical prototype breast CT system than that in previous studies to image subjects from a different geographical region, and used a different algorithm for analysis of image data. The mean VGF estimated from this study is within the range reported in previous studies, indicating that the choice of 50% glandular weight fraction to represent an average breast for Monte Carlo-based estimation of normalized glandular dose coefficients in mammography needs revising. In the study, the distributions of VGF did not differ significantly with pathology.

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-05: Feasibility of Markerless Motion Tracking Using Dual Energy Cone Beam Computed Tomography (DE-CBCT) Projections

Purpose: To compare markerless template-based tracking of lung tumors using dual energy (DE) cone-beam computed tomography (CBCT) projections versus single energy (SE) CBCT projections. Methods: A RANDO chest phantom with a simulated tumor in the upper right lung was used to investigate the effectiveness of tumor tracking using DE and SE CBCT projections. Planar kV projections from CBCT acquisitions were captured at 60 kVp (4 mAs) and 120 kVp (1 mAs) using the Varian TrueBeam and non-commercial iTools Capture software. Projections were taken at approximately every 0.53° while the gantry rotated. Due to limitations of the phantom, angles for which the shoulders blocked the tumor were excluded from tracking analysis. DE images were constructed using a weighted logarithmic subtraction that removed bony anatomy while preserving soft tissue structures. The tumors were tracked separately on DE and SE (120 kVp) images using a template-based tracking algorithm. The tracking results were compared to ground truth coordinates designated by a physician. Matches with a distance of greater than 3 mm from ground truth were designated as failing to track. Results: 363 frames were analyzed. The algorithm successfully tracked the tumor on 89.8% (326/363) of DE frames compared to 54.3% (197/363) of SE frames (p<0.0001). Average distance between tracking and ground truth coordinates was 1.27 +/− 0.67 mm for DE versus 1.83+/−0.74 mm for SE (p<0.0001). Conclusion: This study demonstrates the effectiveness of markerless template-based tracking using DE CBCT. DE imaging resulted in better detectability with more accurate localization on average versus SE. Supported by a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

A New Statistical Estimate of the Radar Coverage of the Low Earth Orbit Debris Environment

For over three decades, the NASA Orbital Debris Program Office (ODPO) has used the Goldstone Orbital Debris Radar, Haystack Ultrawideband Satellite Imaging Radar (HUSIR), and Haystack Auxiliary (HAX) radar assets to collect data on the low Earth orbit (LEO) debris environment. Each radar, with its unique beamwidth, altitude and inclination coverage, and limiting size threshold, operates in a beam park mode to statistically sample the orbital debris population in LEO. Provided that these assets are shared with other users, the orbital debris data collection is not continuous; rather, intermittent data collects are acquired and sent to the NASA ODPO. To understand the sampling process conducted by each radar over time and any related observational biases, a Statistical Confirmation of Radar Uniformity or Bias (SCRUB) code has been implemented to model the coverage of these assets for informing future operations, as well as usage of the data collected from these ground-based sensors. For this analysis, Right Ascension of the Ascending Node (RAAN) is used as a metric to measure statistical coverage. A complete survey of the LEO environment is understood to be measurements that sufficiently sample all values of RAAN for each altitude-inclination pair visible from the radar asset. Regions of incompleteness or statistical bias can help inform future observation campaigns. The SCRUB tool evaluates the coverage of the LEO environment, not by examining individual objects that may pass through a sensor’s field of view (FOV), but by determining which orbit planes pass through the FOV. Once a pointing geometry for a radar site, observation time, and range extent are configured by the user, SCRUB computes the inclinations and altitudes that are visible by the sensor. For each inclination-altitude pair, there is a distinct pair of possible RAAN values, corresponding to the ascending and descending orbit passing through that point in the sensor cone. Repeating this process for all points in the beam, and for multiple time periods during an observation window, creates a matrix of all inclination-altitude-RAAN combinations that are visible during a sensor run. This process can then be repeated for all observations within a year (for an annual survey), propagating all the RAAN values to a common epoch, typically the start of a calendar year, and combining the observations to assemble a full estimate of the RAAN coverage of the LEO environment. This RAAN coverage can then be analyzed for uniformity of sampling, within a certain inclination-altitude pair, or between larger regions of the space environment. This paper provides a general overview of the radar assets utilized by ODPO, typical analysis data products assuming circular orbits, and a discussion of the algorithms that feed between modeling and measurement operations. Following the description of the algorithm, estimates of coverage using HUSIR radar data collected from multiple years are developed and compared.

Chris L Ostrom↗

Video guidance sensor

A Martin-Marietta study comparing the application of laser, video, or RF sensors was conducted in 1982. The study concluded that video was the most attractive sensor (the video also could be used for operator monitoring). The Retro-Reflector field Tracker from the Solar Array Flight Experiment was chosen as a 'first generation' sensor and integrated with guidance algorithms for evaluation on the air-bearing vehicle. Results indicated that this sensor was not applicable for the noise environment posed by the multi-layer insulation used on most spacecraft. A 'second generation' sensor was developed to be used with a modified RMS target. This sensor utilized two sets of laser diodes to acquire three optically filtered targets. The targets were illuminated first with a 780 nanometer diode, followed by illumination with a 830 nm diode. The second digitized picture was subtracted from the first to get a low-noise image. The centroids of the retroreflectors were used then to uniquely derive target attitude and range. The sensor presently operates to 80 feet and within +/- 40 degrees in pitch and yaw. Sensor operability is a concern if the sun is within a +/- 40 degree cone angle to the target. The present sensor performance characteristics are less than 1 percent range error and less than 1 degree angle error. Future sensor development is anticipated to extend the operating range to 150 feet and reduce the cone angle of sensor inoperability to within +/- 10 degrees of direct sunlight. Performance improvements also are anticipated. TRW currently is developing a system that utilizes dual cameras with simultaneous diode illumination. Although further development is being pursued, the basic system has proven sound, and the sensor is essentially ready for application.

Howard, Richard↗

Measurements of jet quenching with semi-inclusive hadron+jet distributions in Au + Au collisions at s N N = 200 GeV

Here, the STAR Collaboration reports the measurement of semi-inclusive distributions of charged-particle jets recoiling from a high transverse momentum hadron trigger, in central and peripheral Au+Au collisions at √ s NN = 200 GeV. Charged jets are reconstructed with the anti-k T algorithm for jet radii R between 0.2 and 0.5 and with low infrared cutoff of track constituents (p T > 0.2 GeV/c). A novel mixed-event technique is used to correct the large uncorrelated background present in heavy ion collisions. Corrected recoil jet distributions are reported at midrapidity, for charged-jet transverse momentum p ch T,jet < 30 GeV/c. Comparison is made to similar measurements for Pb+Pb collisions at √s = 2.76 TeV, to calculations for p+p collisions at √s = 200 GeV based on the pythia Monte Carlo generator and on a next-to-leading order perturbative QCD approach, and to theoretical calculations incorporating jet quenching. The recoil jet yield is suppressed in central relative to peripheral collisions, with the magnitude of the suppression corresponding to medium-induced charged energy transport out of the jet cone of 2.8 ± 0.2(stat) ± 1.5(sys) GeV/c, for 10 < p ch T,jet < 20 GeV/c and R = 0.5. No medium-induced change in jet shape is observed for R < 0.5. The azimuthal distribution of low-p ch T,jet recoil jets may be enhanced at large azimuthal angles to the trigger axis, due to scattering off quasiparticles in the hot QCD medium. As a result, measurement of this distribution gives a 90% statistical confidence upper limit to the yield enhancement at large deflection angles in central Au + Au collisions of 50 ± 30(sys)% of the large-angle yield in p+p collisions predicted by pythia.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An accuracy assessment of different rigid body image registration methods and robotic couch positional corrections using a novel phantom

Purpose: Image guided radiotherapy (IGRT) using cone beam computed tomography (CBCT) images greatly reduces interfractional patient positional uncertainties. An understanding of uncertainties in the IGRT process itself is essential to ensure appropriate use of this technology. The purpose of this study was to develop a phantom capable of assessing the accuracy of IGRT hardware and software including a 6 degrees of freedom patient positioning system and to investigate the accuracy of the Elekta XVI system in combination with the HexaPOD robotic treatment couch top. Methods: The constructed phantom enabled verification of the three automatic rigid body registrations (gray value, bone, seed) available in the Elekta XVI software and includes an adjustable mount that introduces known rotational offsets to the phantom from its reference position. Repeated positioning of the phantom was undertaken to assess phantom rotational accuracy. Using this phantom the accuracy of the XVI registration algorithms was assessed considering CBCT hardware factors and image resolution together with the residual error in the overall image guidance process when positional corrections were performed through the HexaPOD couch system. Results: The phantom positioning was found to be within 0.04 ({sigma}= 0.12) Degree-Sign , 0.02 ({sigma}= 0.13) Degree-Sign , and -0.03 ({sigma}= 0.06) Degree-Sign in X, Y, and Z directions, respectively, enabling assessment of IGRT with a 6 degrees of freedom patient positioning system. The gray value registration algorithm showed the least error in calculated offsets with maximum mean difference of -0.2({sigma}= 0.4) mm in translational and -0.1({sigma}= 0.1) Degree-Sign in rotational directions for all image resolutions. Bone and seed registration were found to be sensitive to CBCT image resolution. Seed registration was found to be most sensitive demonstrating a maximum mean error of -0.3({sigma}= 0.9) mm and -1.4({sigma}= 1.7) Degree-Sign in translational and rotational directions over low resolution images, and this is reduced to -0.1({sigma}= 0.2) mm and -0.1({sigma}= 0.79) Degree-Sign using high resolution images. Conclusions: The phantom, capable of rotating independently about three orthogonal axes was successfully used to assess the accuracy of an IGRT system considering 6 degrees of freedom. The overall residual error in the image guidance process of XVI in combination with the HexaPOD couch was demonstrated to be less than 0.3 mm and 0.3 Degree-Sign in translational and rotational directions when using the gray value registration with high resolution CBCT images. However, the residual error, especially in rotational directions, may increase when the seed registration is used with low resolution images.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-04: Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation

Purpose: Scatter artifacts severely degrade image quality of cone-beam CT (CBCT). We present an ultrafast scatter correction framework by using GPU-based Monte Carlo (MC) simulation and prior patient CT image, aiming at automatically finish the whole process including both scatter correction and reconstructions within 30 seconds. Methods: The method consists of six steps: 1) FDK reconstruction using raw projection data; 2) Rigid Registration of planning CT to the FDK results; 3) MC scatter calculation at sparse view angles using the planning CT; 4) Interpolation of the calculated scatter signals to other angles; 5) Removal of scatter from the raw projections; 6) FDK reconstruction using the scatter-corrected projections. In addition to using GPU to accelerate MC photon simulations, we also use a small number of photons and a down-sampled CT image in simulation to further reduce computation time. A novel denoising algorithm is used to eliminate MC scatter noise caused by low photon numbers. The method is validated on head-and-neck cases with simulated and clinical data. Results: We have studied impacts of photo histories, volume down sampling factors on the accuracy of scatter estimation. The Fourier analysis was conducted to show that scatter images calculated at 31 angles are sufficient to restore those at all angles with <0.1% error. For the simulated case with a resolution of 512×512×100, we simulated 10M photons per angle. The total computation time is 23.77 seconds on a Nvidia GTX Titan GPU. The scatter-induced shading/cupping artifacts are substantially reduced, and the average HU error of a region-of-interest is reduced from 75.9 to 19.0 HU. Similar results were found for a real patient case. Conclusion: A practical ultrafast MC-based CBCT scatter correction scheme is developed. The whole process of scatter correction and reconstruction is accomplished within 30 seconds. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China (2011A081402003)

60 APPLIED LIFE SCIENCES↗

A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view

Purpose: Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method to increase the FOV for current on-board CBCT systems. Methods: When a large patient is scanned with CBCT, any region outside the FOV is only partially sampled within a short range of projection angles, and at other angles no x-ray beams may pass through that region. To increase the sampling rate for the region outside the FOV, we have designed a new source trajectory by shifting the center of rotation during a CBCT scan. This resulted in a reduced sampling rate at the central area and increased sampling rate at the edges. The tradeoff led to a more balanced sampling for an enlarged FOV. An iterative algorithm was also developed to reconstruct the CT image under the new sampling scheme using a compressed sensing technique. Results: The method was validated by numerical simulations mimicking a Varian Trilogy CBCT system, and it was found that artifact-free images could be obtained with the FOV as large as 80 cm. Conclusions: The new CT scanning trajectory can be easily realized under current clinical setup with little modification of the control system, and this can be useful for treating obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-207B-12: Scatter Correction for Dedicated Cone Beam Breast CT Based On a Forward Projection Model

Purpose: The image quality of dedicated cone-beam breast CT (CBBCT) is fundamentally limited by substantial x-ray scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose to suppress x-ray scatter in CBBCT images using a deterministic forward projection model. Method: We first use the 1st-pass FDK-reconstructed CBBCT images to segment fibroglandular and adipose tissue. Attenuation coefficients are assigned to the two tissues based on the x-ray spectrum used for imaging acquisition, and is forward projected to simulate scatter-free primary projections. We estimate the scatter by subtracting the simulated primary projection from the measured projection, and then the resultant scatter map is further refined by a Fourier-domain fitting algorithm after discarding untrusted scatter information. The final scatter estimate is subtracted from the measured projection for effective scatter correction. In our implementation, the proposed scatter correction takes 0.5 seconds for each projection. The method was evaluated using the overall image spatial non-uniformity (SNU) metric and the contrast-to-noise ratio (CNR) with 5 clinical datasets of BI-RADS 4/5 subjects. Results: For the 5 clinical datasets, our method reduced the SNU from 7.79% to 1.68% in coronal view and from 6.71% to 3.20% in sagittal view. The average CNR is improved by a factor of 1.38 in coronal view and 1.26 in sagittal view. Conclusion: The proposed scatter correction approach requires no additional scans or prior images and uses a deterministic model for efficient calculation. Evaluation with clinical datasets demonstrates the feasibility and stability of the method. These features are attractive for clinical CBBCT and make our method distinct from other approaches. Supported partly by NIH R21EB019597, R21CA134128 and R01CA195512.The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Human Factors Evaluation of Conflict Detection Tool for Terminal Area

A conflict detection and resolution tool, Terminal-area Tactical Separation-Assured Flight Environment (T-TSAFE), is being developed to improve the timeliness and accuracy of alerts and reduce the false alert rate observed with the currently deployed technology. The legacy system in use today, Conflict Alert, relies primarily on a dead reckoning algorithm, whereas T-TSAFE uses intent information to augment dead reckoning. In previous experiments, T-TSAFE was found to reduce the rate of false alerts and increase time between the alert to the controller and a loss of separation over the legacy system. In the present study, T-TSAFE was tested under two meteorological conditions, 1) all aircraft operated under instrument flight regimen, and 2) some aircraft operated under mixed operating conditions. The tool was used to visually alert controllers to predicted Losses of separation throughout the terminal airspace, and show compression errors, on final approach. The performance of T-TSAFE on final approach was compared with Automated Terminal Proximity Alert (ATPA), a tool recently deployed by the FAA. Results show that controllers did not report differences in workload or situational awareness between the T-TSAFE and ATPA cones but did prefer T-TSAFE features over ATPA functionality. T-TSAFE will provide one tool that shows alerts in the data blocks and compression errors via cones on the final approach, implementing all tactical conflict detection and alerting via one tool in TRACON airspace.

Verma, Savita Arora↗