Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPUTER ANIMATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.

60 APPLIED LIFE SCIENCES↗

Mobility analysis, simulation, and scale model testing for the design of wheeled planetary rovers

The use of computer based techniques to model and simulate wheeled rovers on rough natural terrains is considered. Physical models of a prototype vehicle can be used to test the correlation of the simulations in scaled testing. The computer approaches include a quasi-static planar or two dimensional analysis and design tool based on the traction necessary for the vehicle to have imminent mobility. The computer program modeled a six by six wheel drive vehicle of original kinematic configuration, called the Rocker Bogie. The Rocker Bogie was optimized using the quasi-static software with respect to its articulation parameters prior to fabrication of a prototype. In another approach used, the dynamics of the Rocker Bogie vehicle in 3-D space was modeled on an engineering workstation using commercial software. The model included the complex and nonlinear interaction of the tire and terrain. The results of the investigation yielded numerical and graphical results of the rover traversing rough terrain on the earth, moon, and Mars. In addition, animations of the rover excursions were also generated. A prototype vehicle was then used in a series of testbed and field experiments. Correspondence was then established between the computer models and the physical model. The results indicated the utility of the quasi-static tool for configurational design, as well as the predictive ability of the 3-D simulation to model the dynamic behavior of the vehicle over short traverses.

Lindemann, Randel A.↗

Prospective Evaluation of Radiotherapy With Concurrent and Adjuvant Temozolomide in Children With Newly Diagnosed Diffuse Intrinsic Pontine Glioma

Purpose: To present outcome data in a prospective study of radiotherapy (RT) with concurrent and adjuvant temozolomide (TMZ) in children with diffuse intrinsic pontine gliomas (DIPGs). Methods and Materials: Pediatric patients with newly diagnosed DIPGs were prospectively treated with focal RT to a dose of 54 Gy in 30 fractions along with concurrent daily TMZ (75 mg/m{sup 2}, Days 1-42). Four weeks after completing the initial RT-TMZ schedule, adjuvant TMZ (200 mg/m{sup 2}, Days 1-5) was given every 28 days to a maximum of 12 cycles. Response was evaluated clinically and radiologically with magnetic resonance imaging and positron emission tomography scans. Results: Between March 2005 and November 2006, 20 children (mean age, 8.3 years) were accrued. Eighteen patients have died from disease progression, one patient is alive with progressive disease, and one patient is alive with stable disease. Median overall survival and progression-free survival were 9.15 months and 6.9 months, respectively. Grade III/IV toxicity during the concurrent RT-TMZ phase included thrombocytopenia in 3 patients, leucopenia in 2, and vomiting in 7. Transient Grade II skin toxicity developed in the irradiated fields in 18 patients. During the adjuvant TMZ phase, Grade III/IV leucopenia developed in 2 patients and Grade IV thrombocytopenia in 1 patient. Patients with magnetic resonance imaging diagnosis of a high-grade tumor had worse survival than those with a low-grade tumor (p = 0.001). Patients with neurologic improvement after RT-TMZ had significantly better survival than those who did not (p = 0.048). Conclusions: TMZ with RT has not yielded any improvement in the outcome of DIPG compared with RT alone. Further clinical trials should explore novel treatment modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of FMISO simulations with pimonidazole-stained tumor xenografts: A question of O{sub 2} consumption?

Purpose: To compare a dedicated simulation model for hypoxia PET against tumor microsections stained for different parameters of the tumor microenvironment. The model can readily be adapted to a variety of conditions, such as different human head and neck squamous cell carcinoma (HNSCC) xenograft tumors. Methods: Nine different HNSCC tumor models were transplanted subcutaneously into nude mice. Tumors were excised and immunoflourescently labeled with pimonidazole, Hoechst 33342, and CD31, providing information on hypoxia, perfusion, and vessel distribution, respectively. Hoechst and CD31 images were used to generate maps of perfused blood vessels on which tissue oxygenation and the accumulation of the hypoxia tracer FMISO were mathematically simulated. The model includes a Michaelis–Menten relation to describe the oxygen consumption inside tissue. The maximum oxygen consumption rate M{sub 0} was chosen as the parameter for a tumor-specific optimization as it strongly influences tracer distribution. M{sub 0} was optimized on each tumor slice to reach optimum correlations between FMISO concentration 4 h postinjection and pimonidazole staining intensity. Results: After optimization, high pixel-based correlations up to R{sup 2} = 0.85 were found for individual tissue sections. Experimental pimonidazole images and FMISO simulations showed good visual agreement, confirming the validity of the approach. Median correlations per tumor model varied significantly (p < 0.05), with R{sup 2} ranging from 0.20 to 0.54. The optimum maximum oxygen consumption rate M{sub 0} differed significantly (p < 0.05) between tumor models, ranging from 2.4 to 5.2 mm Hg/s. Conclusions: It is feasible to simulate FMISO distributions that match the pimonidazole retention patterns observed in vivo. Good agreement was obtained for multiple tumor models by optimizing the oxygen consumption rate, M{sub 0}, whose optimum value differed significantly between tumor models.

60 APPLIED LIFE SCIENCES↗

TU-H-207A-03: CT Hounsfield Unit Accuracy: Effect of Beam Hardening On Phantom and Clinical Whole-Body CT Images

Purpose: To assess the effect of beam hardening on measured CT HU values. Methods: An anthropomorphic knee phantom was scanned with the CT component of a GE Discovery 690 PET/CT scanner (120kVp, 300mAs, 40?0.625mm collimation, pitch=0.984, FOV=500mm, matrix=512?512) with four different scan setups, each of which induces different degrees of beam hardening by introducing additional attenuation media into the field of view. Homogeneous voxels representing “soft tissue” and “bone” were segmented by HU thresholding followed by a 3D morphological erosion operation which removes the non-homogenous voxels located on the interface of thresholded tissue mask. HU values of segmented “soft tissue” and “bone” were compared.Additionally, whole-body CT data with coverage from the skull apex to the end of toes were retrospectively retrieved from seven PET/CT exams to evaluate the effect of beam hardening in vivo. Homogeneous bone voxels were segmented with the same method previously described. Total In-Slice Attenuation (TISA) for each CT slice, defined as the summation of HU values over all voxels within a CT slice, was calculated for all slices of the seven whole-body CT datasets and evaluated against the mean HU values of homogeneous bone voxels within that slice. Results: HU values measured from the phantom showed that while “soft tissue” HU values were unaffected, added attenuation within the FOV caused noticeable decreases in the measured HU values of “bone” voxels. A linear relationship was observed between bone HU and TISA for slices of the torso and legs, but not of the skull. Conclusion: Beam hardening effect is not an issue of concern for voxels with HU in the soft tissue range, but should not be neglected for bone voxels. A linear relationship exists between bone HU and the associated TISA in non-skull CT slices, which can be exploited to develop a correction strategy.

60 APPLIED LIFE SCIENCES↗

Ames Research Center SR&T program and earth observations

An overview is presented of the research activities in earth observations at Ames Research Center. Most of the tasks involve the use of research aircraft platforms. The program is also directed toward the use of the Illiac 4 computer for statistical analysis. Most tasks are weighted toward Pacific coast and Pacific basin problems with emphasis on water applications, air applications, animal migration studies, and geophysics.

Poppoff, I. G.↗

The cat vertebral column: stance configuration and range of motion

This study examined the configuration of the vertebral column of the cat during independent stance and in various flexed positions. The range of motion in the sagittal plane is similar across most thoracic and lumbar joints, with the exception of a lesser range at the transition region from thoracic-type to lumbar-type vertebrae. The upper thoracic column exhibits most of its range in dorsiflexion and the lower thoracic and lumbar in ventroflexion. Lateral flexion is limited to less than 5 degrees at all segments. The range in torsion is almost 180 degrees and occurs primarily in the midthoracic region, T4-T11. Contrary to the depiction in most atlases, the standing cat exhibits several curvatures, including a mild dorsiflexion in the lower lumbar segments, a marked ventroflexion in the lower thoracic and upper lumbar segments, and a profound dorsiflexion in the upper thoracic (above T9) and cervical segments. The curvatures are not significantly changed by altering stance distance but are affected by head posture. During stance, the top of the scapula lies well above the spines of the thoracic vertebrae, and the glenohumeral joint is just below the bodies of vertebrae T3-T5. Using a simple static model of the vertebral column in the sagittal plane, it was estimated that the bending moment due to gravity is bimodal with a dorsiflexion moment in the lower thoracic and lumbar region and a ventroflexion moment in the upper thoracic and cervical region. Given the bending moments and the position of the scapula during stance, it is proposed that two groups of scapular muscles provide the major antigravity support for the head and anterior trunk. Levator scapulae and serratus ventralis form the lateral group, inserting on the lateral processes of cervical vertebrae and on the ribs. The major and minor rhomboids form the medial group, inserting on the spinous tips of vertebrae from C4 to T4. It is also proposed that the hypaxial muscles, psoas major, minor, and quadratus lumborum could support the lumbar trunk during stance.

NASA Discipline Neuroscience↗

National Virtual Biotechnology Laboratory: Report on Rapid R&D Solutions to the COVID-19 Crisis

With funding from the CARES Act, the U.S Department of Energy (DOE) established the National Virtual Biotechnology Laboratory (NVBL) in March 2020 to address key challenges associated with the COVID-19 crisis. NVBL brought together the broad scientific and technical expertise and resources of DOE’s 17 national laboratories to help tackle medical supply short ages, discover potential drugs to fight the virus, develop and validate COVID-19 testing methods, model disease spread and impact across the nation, and understand virus transport in buildings and the environment. National laboratory resources leveraged for this effort include a suite of world-leading user facilities broadly available to the research community, such as light and neutron sources, nanoscale science research centers, sequencing and biocharacterization facilities, and high-performance computing facilities. Within months, NVBL teams produced innovations in materials and advanced manufacturing that mitigated shortages in test kits and personal protective equipment (PPE), creating nearly 1,000 new jobs. They used DOE’s high-performance computers and light and neutron sources to identify promising candidates for antibodies and antivirals that universities and drug companies are now evaluating. NVBL researchers also developed new diagnostic targets and sample collection approaches, and supported U.S. Food and Drug Administration (FDA), Centers for Disease Control and Prevention (CDC), and U.S. Department of Defense (DoD) efforts to establish national guidelines used in administering millions of tests. Researchers used artificial intelligence and high-performance computing to produce near-real-time data analysis to forecast disease transmission, stress on public health infrastructure, and economic impact, which supported decision-makers at the local, state, and national levels. NVBL teams also studied how to control indoor virus movement to minimize uptake and protect human health. NVBL’s accomplishments demonstrate not only the powerful resource represented by DOE’s national laboratories working together to meet national needs, but also the effectiveness of the integrated NVBL framework for rapidly responding to emergencies with research and development (R&D) solutions. As the fight against COVID continues, sustained efforts are needed to confront this pandemic as well as future threats. Examples include: 1) Establishing “supply chains on demand” to meet emergency production needs by leveraging the materials and manufacturing expertise of DOE national laboratories and developing advances in electronics, sensing, robotics, and automation capabilities; 2) Improving the speed and robustness of drug discovery by integrating experimental platforms with DOE’s computational and experimental user facilities, which provide unique resources to support the discovery of high-potential therapeutic agents; 3) Protecting public, environmental, and animal health by developing new testing protocols and instrumentation adaptable to diverse sample types (both physiological and environmental) to quickly detect a wide range of pathogens and monitor other biorisks; 4) Supporting near-real-time data needs of decision-makers at the local, regional, state, and national levels by advancing data curation, analysis, and modeling using artificial intelligence and new data science tools for managing and evaluating large diverse datasets; 5) Harnessing DOE’s expertise in environmental modeling to design rooms and air handling for offices, classrooms, restaurants, and other structures to minimize biorisk transmissions. Going forward, NVBL is poised to apply the unique capabilities and expertise of the national laboratory complex to future national and international emergencies, both natural and engineered. Through this framework, the Office of Science will continue to be an integral component of agency wide efforts to prepare for and respond to biorisks and other crises.

42 ENGINEERING↗

Generalized interactions using virtual tools within the spring framework: cutting

We present schemes for real-time generalized mesh cutting. Starting with the a basic example, we describe the details of implementing cutting on single and multiple surface objects as well as hybrid and volumetric meshes using virtual tools with single and multiple cutting surfaces. These methods have been implemented in a robust surgical simulation environment allowing us to model procedures ranging from animal dissection to cleft lip correction.

Feedback↗

The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization

Purpose: We previously developed a set of highly detailed 4D reference pediatric extended cardiac-torso (XCAT) phantoms at ages of newborn, 1, 5, 10, and 15 yr with organ and tissue masses matched to ICRP Publication 89 values. In this work, we extended this reference set to a series of 64 pediatric phantoms of varying age and height and body mass percentiles representative of the public at large. The models will provide a library of pediatric phantoms for optimizing pediatric imaging protocols. Methods: High resolution positron emission tomography-computed tomography data obtained from the Duke University database were reviewed by a practicing experienced radiologist for anatomic regularity. The CT portion of the data was then segmented with manual and semiautomatic methods to form a target model defined using nonuniform rational B-spline surfaces. A multichannel large deformation diffeomorphic metric mapping algorithm was used to calculate the transform from the best age matching pediatric XCAT reference phantom to the patient target. The transform was used to complete the target, filling in the nonsegmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. The mass for each major tissue was calculated and compared to linearly interpolated ICRP values for different ages. Results: Sixty four new pediatric phantoms were created in this manner. Each model contains the same level of detail as the original XCAT reference phantoms and also includes parameterized models for the cardiac and respiratory motions. For the phantoms that were 10 yr old and younger, we included both sets of reproductive organs. This gave them the capability to simulate both male and female anatomy. With this, the population can be expanded to 92. Wide anatomical variation was clearly seen amongst the phantom models, both in organ shape and size, even for models of the same age and sex. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: This work provides a large cohort of highly detailed pediatric phantoms with 4D capabilities of varying age, height, and body mass. The population of phantoms will provide a vital tool with which to optimize 3D and 4D pediatric imaging devices and techniques in terms of image quality and radiation-absorbed dose.

60 APPLIED LIFE SCIENCES↗

A three-dimensional model of terrain-induced updrafts for movement ecology studies

Abstract Background Spatially explicit simulation models of animal movements through the atmosphere necessarily require a representation of the spatial and temporal variation of atmospheric conditions. In particular, for movements of soaring birds that rely extensively on vertical updrafts to avoid flapping flight, accurate and reliable estimation of the vertical component of wind is critical. The interaction between wind and complex terrain shapes both the horizontal and vertical wind fields, highlighting the need to model the coupling between local terrain features and atmospheric conditions at scales relevant to animal movement. Methods In this work, we propose a new empirical model for estimating the orographic updraft field. The model is developed using computational fluid dynamics simulations of canonical atmospheric conditions over moderately complex terrain. To isolate buoyancy and thermal effects, and focus on terrain-induced effects, we use only simulations of a neutrally stratified atmosphere to develop the model. The model, which we name Engineering Vertical Velocity Estimator (EVVE), is simple to implement and is a function of the underlying terrain elevation map, the desired height above ground level (AGL), and wind conditions at a reference height (80 m). We validate the model with data from the Alaiz mountain (Spain) field campaign. Results Compared to observations, the proposed improved model estimates the updrafts at 120 m AGL with a mean error of 0.11 m/s ( $$\sigma =0.28$$ σ = 0.28 m/s), compared to 0.85 m/s ( $$\sigma =0.58$$ σ = 0.58 m/s) for its baseline. For typical land-based wind turbine hub heights of 80 m AGL, the proposed model has a mean error of 0.04 m/s ( $$\sigma =0.25$$ σ = 0.25 m/s), compared to baseline 0.54 m/s ( $$\sigma =0.45$$ σ = 0.45 m/s) estimations. We illustrate an application of the model in movement ecology by comparing simulated tracks and presence maps of golden eagles ( Aquila chrysaetos ) moving across two distinct landscapes. The tracks and presence maps are obtained using a simple heuristic-based movement model, with the updraft field given by the proposed model and a wind vector-based estimation approach that is currently in wide use in movement ecology studies of raptors and other soaring birds. Conclusions We highlight that movement model results can be sensitive to the underlying orographic updraft model, especially in studies of fine-scale movements in regions of complex topography. We suggest adopting the proposed model rather than the wind vector estimation method for studies of soaring bird movements.

17 WIND ENERGY↗

Bioaccumulation Factor for Radium in Rio Grande Biota

The Los Alamos National Laboratory (LANL or Laboratory) Environmental Protection and Compliance Division’s Environmental Stewardship Group (EPC-ES) performs the radiological analysis portion of biota dose assessments using the computer program RESRAD-Biota (DOE 2004, DOE 2020). RESRAD-Biota uses a default bioaccumulation factor, B iv , for radium in aquatic animals. This bioaccumulation factor, also listed in Department of Energy (DOE) Standard, DOE-STD-1153-2019, is the ratio of a radionuclide concentration in fresh weight biota to the environment in which it resides, which for aquatic animals is water. DOE-STD-1153-2019 offers conservative values for these ratios that are specific to the radiological contaminant, the biota, and the environment. The B iv in RESRAD-Biota can be used for general screening (Level 1 screening). If the factor proves to be too conservative, then a site-specific B iv may be used. The biota dose assessment of fish from the northern New Mexico region of the Rio Grande fail the general screen, which indicates that further analysis is necessary. Level 2 analysis is site-specific but still has conservative limitations. Level 3 analysis is a more realistic and representative, sitespecific analysis. The purpose of this paper is to use data specific to the Rio Grande to calculate a new aquatic animal radium B iv . This B iv can then be used for Level 3 analysis of aquatic animals specifically in the northern New Mexico region of the Rio Grande. The calculated radium B iv is a useful value for performing detailed, accurate biota dose assessments and calculating dose to fish using RESRAD-Biota when only sediment data are available.

54 ENVIRONMENTAL SCIENCES↗

Material processing of convection-driven flow field and temperature distribution under oblique gravity

A set of mathematical formulation is adopted to study vapor deposition from source materials driven by heat transfer process under normal and oblique directions of gravitational acceleration with extremely low pressure environment of 10(exp -2) mm Hg. A series of time animation of the initiation and development of flow and temperature profiles during the course of vapor deposition has been obtained through the numerical computation. Computations show that the process of vapor deposition has been accomplished by the transfer of vapor through a fairly complicated flow pattern of recirculation under normal direction gravitational acceleration. It is obvious that there is no way to produce a homogeneous thin crystalline films with fine grains under such a complicated flow pattern of recirculation with a non-uniform temperature distribution under normal direction gravitational acceleration. There is no vapor deposition due to a stably stratified medium without convection for reverse normal direction gravitational acceleration. Vapor deposition under oblique direction gravitational acceleration introduces a reduced gravitational acceleration in vertical direction which is favorable to produce a homogeneous thin crystalline films. However, oblique direction gravitational acceleration also induces an unfavorable gravitational acceleration along horizontal direction which is responsible to initiate a complicated flow pattern of recirculation. In other words, it is necessary to carry out vapor deposition under a reduced gravity in the future space shuttle experiments with extremely low pressure environment to process vapor deposition with a homogeneous crystalline films with fine grains. Fluid mechanics simulation can be used as a tool to suggest most optimistic way of experiment with best setup to achieve the goal of processing best nonlinear optical materials.

Hung, R. J.↗

Use of Human Modeling Simulation Software in the Task Analysis of the Environmental Control and Life Support System Component Installation Procedures

Virtual reality and simulation applications are becoming widespread in human task analysis. These programs have many benefits for the Human Factors Engineering field. Not only do creating and using virtual environments for human engineering analyses save money and time, this approach also promotes user experimentation and provides increased quality of analyses. This paper explains the human engineering task analysis performed on the Environmental Control and Life Support System (ECLSS) space station rack and its Distillation Assembly (DA) subsystem using EAI's human modeling simulation software, Jack. When installed on the International Space Station (ISS), ECLSS will provide the life and environment support needed to adequately sustain crew life. The DA is an Orbital Replaceable Unit (ORU) that provides means of wastewater (primarily urine from flight crew and experimental animals) reclamation. Jack was used to create a model of the weightless environment of the ISS Node 3, where the ECLSS is housed. Computer aided drawings of the ECLSS rack and DA system were also brought into the environment. Anthropometric models of a 95th percentile male and 5th percentile female were used to examine the human interfaces encountered during various ECLSS and DA tasks. The results of the task analyses were used in suggesting modifications to hardware and crew task procedures to improve accessibility, conserve crew time, and add convenience for the crew. This paper will address some of those suggested modifications and the method of presenting final analyses for requirements verification.

Estes, Samantha↗

Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications

Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-hold CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum Computation and Visualization of Carbon Single and Double Nano-Rings

This paper concentrates on computational nanoscience to better understand the properties of different materials of interest. In particular, the material graphene has many interesting properties with promising applications. This project will focus on different carbon nanostructures, including the hexagonal honeycomb lattices of a single graphene sheet. Using visualization, animation, and simulation, the thermodynamic properties and energy spectrum of the different carbon nanostructures, mainly carbon nano-ring of different geometries were investigated. The tight-binding model for interacting and non-interacting systems of bosons and fermions was implemented on Mathematica and IBM-Q's quantum computing platform QISkit for a thorough understanding of these atomic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the Feasibility of Isolated Pancreatic Perfusion for Chemotherapy Using Computed Tomography: An Experimental Study in Pig Models

PurposePercutaneous isolated pancreatic perfusion (PIPP) is performed along with interventional radiology techniques to obtain high drug concentration by occluding the arterial inlet and venous outlet of the pancreas. The experimental study aimed to evaluate the contrast distribution in PIPP under different flow rates with or without anterior mesenteric artery (AMA) occlusion.Materials and MethodsThis study was approved by a local animal experiment ethics committee. Nine pigs were divided into Groups 1, 2, and 3, by infusion rates of 12, 24, and 36 mL/min. Groups 4 and 5 (3 pigs each) and Group 6 (2 pigs) underwent PIPP at the same respective infusion rates with and without AMA occlusion. Computed tomography (CT) arteriography was performed during PIPP with nonionic contrast media. The enhanced volume was calculated by adding the enhanced area in each slice using 1.25-mm axial images. The percent enhanced volume to the whole pancreas (%eV) was used to simulate drug distribution; the result was compared among groups.ResultsWithout AMA occlusion, a larger %eV was obtained with high infusion rates (P = 0.039). The median %eV in Groups 1, 2, and 3 were 57.7, 74.2, and 90.5%, respectively. With AMA occlusion, CT demonstrated duodenal enhancement at an infusion rate of 36 mL/min, and the median %eV in Groups 4, 5, and 6 were 92.8, 95.4, and 98.5%, respectively. A significantly larger %eV was obtained after AMA occlusion (P = 0.031).ConclusionA higher infusion rate or AMA occlusion increases the enhanced volume in PIPP in pig models. Level of evidence: No level of evidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applying a Hypoxia-Incorporating TCP Model to Experimental Data on Rat Sarcoma

Purpose: To verify whether a tumor control probability (TCP) model which mechanistically incorporates acute and chronic hypoxia is able to describe animal in vivo dose-response data, exhibiting tumor reoxygenation. Methods and Materials: The investigated TCP model accounts for tumor repopulation, reoxygenation of chronic hypoxia, and fluctuating oxygenation of acute hypoxia. Using the maximum likelihood method, the model is fitted to Fischer-Moulder data on Wag/Rij rats, inoculated with rat rhabdomyosarcoma BA1112, and irradiated in vivo using different fractionation schemes. This data set is chosen because two of the experimental dose-response curves exhibit an inverse dose behavior, which is interpreted as due to reoxygenation. The tested TCP model is complex, and therefore, in vivo cell survival data on the same BA1112 cell line from Reinhold were added to Fischer-Moulder data and fitted simultaneously with a corresponding cell survival function. Results: The obtained fit to the combined Fischer-Moulder-Reinhold data was statistically acceptable. The best-fit values of the model parameters for which information exists were in the range of published values. The cell survival curves of well-oxygenated and hypoxic cells, computed using the best-fit values of the radiosensitivities and the initial number of clonogens, were in good agreement with the corresponding in vitro and in situ experiments of Reinhold. The best-fit values of most of the hypoxia-related parameters were used to recompute the TCP for non-small cell lung cancer patients as a function of the number of fractions, TCP(n). Conclusions: The investigated TCP model adequately describes animal in vivo data exhibiting tumor reoxygenation. The TCP(n) curve computed for non-small cell lung cancer patients with the best-fit values of most of the hypoxia-related parameters confirms previously obtained abrupt reduction in TCP for n < 10, thus warning against the adoption of severely hypofractionated schedules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗