Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Pondermotive versus mirror force in creation of the filamentary cavities in auroral plasma

Recently rocket observations on spikelets of lower-hybrid waves along with strong density cavities and transversely heated ions were reported. The observed thin filamentary cavities oriented along the magnetic field in the auroral plasma have density depletions up to several tens of percent. These observations have been interpreted in terms of a theory for lower-hybrid wave condensation and collapse. The modulational instability leading to the wave consensation of the lower-hybrid waves yields only weak density perturbations, which cannot explain the above strong density depletions. The wave collapse theory is based on the nonlinear pondermotive force in a homogeneous ambient plasma and the density depletion is determined by the balance between the wave pressure (pondermotive force) and the plasma pressure. In the auroral plasma, the balance is achieved in a time tau(sub wc) equal to or less than 1 ms. It is shown here that the mirror force, acting on the transversely heated ions at a relatively long time scale, is an effective mechanism for creating the strong plasma cavities. We suggest that the process of wave condensation, through the pondermotive force causing generation of short wavelength waves from relatively long wavelength waves, is a dominant process until the former waves evolve and become effective in the transverse heating of ions. As soon as this happens, mirror force on ions becomes an important factor in the creation of the density cavities, which may further trap and enhance the waves. Results from a model of cavity formation by transverse ion heating show that the observed depletions in the density cavities can be produced by the heating rates determined by the observed wave amplitudes near the lower-hybrid frequency. It is found that the creation of a strong density cavity takes a few minutes.

Singh, Nagendra↗

Aeropropulsion Technology (APT). Task 23 - Stator Seal Cavity Flow Investigation

The focus of NASA Contract NAS3-25950 Task 23 was to numerically investigate the flow through an axial compressor inner-banded stator seal cavity. The Allison/NASA developed ADPAC code was used to obtain all flow predictions. Flow through a labyrinth stator seal cavity of a high-speed compressor was modeled by coupling the cavity flow path and the main flow path of the compressor. A grid resolution study was performed to guarantee adequate grid spacing was used. Both unsteady rotor-stator-rotor interactions and steady-state isolated blade calculations were performed with and without the seal cavity present. A parameterized seal cavity study of the high-speed stator seal cavity collected a series of solutions for geometric variations. The parameter list included seal tooth gap, cavity depth, wheel speed, radial mismatch of hub flowpath, axial trench gap, hub corner treatments, and land edge treatments. Solution data presented includes radial and pitchwise distributions of flow variables and particle traces describing the flow character.

Heidegger, N. J.↗

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

Strayer, D. M.↗

Heat Shield Cavity Parametric Experimental Aeroheating for a Proposed Mars Smart Lander Aeroshell

The proposed Mars Smart Lander is to be attached through its aeroshell to the main spacecraft bus, thereby producing cavities in the heat shield. To study the effects these cavities will have on the heating levels experienced by the heat shield, an experimental aeroheating investigation was performed at the NASA Langley Research Center in the 20-Inch Mach 6 Air Tunnel. The effects of Reynolds number, angle-of-attack, and cavity size and location on aero-heating levels and distributions were determined and are presented. To aid the discussion on the effects of the cavities, laminar, thin-layer Navier-Stokes flow field solutions were post-processed to calculate relevant boundary layer properties such as boundary layer height and momentum thickness, edge Mach number, and streamwise pressure gradient. It was found that the effect of the cavities varies with angle-of-attack, freestream Reynolds number, and cavity size and location. The presence of a cavity raised the downstream heating rates by as much as 325% as a result of boundary layer transition.

Liechty, Derek S.↗

Experimental Feedback Control of Flow Induced Cavity Tones

Discrete-time, linear quadratic methods were used to design feedback controllers for reducing tones generated by flow over a cavity. The dynamics of a synthetic jet actuator mounted at the leading edge of the cavity as observed by two microphones in the cavity were modeled over a broad frequency range using state space models computed from experimental data. Variations in closed loop performance as a function of model order, control order, control bandwidth, and state estimator design were studied using a cavity in the Probe Calibration Tunnel at NASA Langley. The controller successfully reduced the levels of multiple cavity tones at the tested flow speeds of Mach 0.275, 0.35, and 0.45. In some cases, the closed loop results were limited by excitation of sidebands of the cavity tones, or the creation of new tones at frequencies away from the cavity tones. Nonetheless, the results validate the combination of optimal control and experimentally-generated state space models, and suggest this approach may be useful for other flow control problems. The models were not able to account for non-linear dynamics, such as interactions between tones at different frequencies.

Cabell, Randolph H.↗

Piezo activated mode tracking system for widely tunable mode-hop-free external cavity mid-IR semiconductor lasers

A widely tunable, mode-hop-free semiconductor laser operating in the mid-IR comprises a QCL laser chip having an effective QCL cavity length, a diffraction grating defining a grating angle and an external cavity length with respect to said chip, and means for controlling the QCL cavity length, the external cavity length, and the grating angle. The laser of claim 1 wherein said chip may be tuned over a range of frequencies even in the absence of an anti-reflective coating. The diffraction grating is controllably pivotable and translatable relative to said chip and the effective QCL cavity length can be adjusted by varying the injection current to the chip. The laser can be used for high resolution spectroscopic applications and multi species trace-gas detection. Mode-hopping is avoided by controlling the effective QCL cavity length, the external cavity length, and the grating angle so as to replicate a virtual pivot point.

Wysocki, Gerard↗

Forward Modeling of a Coronal Cavity

We apply a forward model of emission from a coronal cavity in an effort to determine the temperature and density distribution in the cavity. Coronal cavities are long, low-density structures located over filament neutral lines and are often seen as dark elliptical features at the solar limb in white light, EUV and X-rays. When these structures erupt they form the cavity portions of CMEs The model consists of a coronal streamer model with a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel length. Temperature and density can be varied as a function of altitude both in the cavity and streamer. We apply this model to a cavity observed in Aug. 2007 by a wide array of instruments including Hinode/EIS, STEREO/EUVI and SOHO/EIT. Studies such as these will ultimately help us understand the the original structures which erupt to become CMEs and ICMES, one of the prime Solar Orbiter objectives.

Kucera, T. A.↗

Strong Magnetic Field Fluctuations within Filamentary Auroral Density Cavities Interpreted as VLF Saucer Sources

The Geoelectrodynamics and Electro-Optical Detection of Electron and SuprathermalIon Currents (GEODESIC) sounding rocket encountered more than 100 filamentary densitycavities associated with enhanced plasma waves at ELF (3 kHz) and VLF (310 kHz)frequencies and at altitudes of 800990 km during an auroral substorm. These cavities weresimilar in size (20 m diameter in most cases) to so-called lower-hybrid cavities (LHCs)observed by previous sounding rockets and satellites; however, in contrast, many of theGEODESIC cavities exhibited up to tenfold enhancements in magnetic wave powerthroughout the VLF band. GEODESIC also observed enhancements of ELF and VLFelectric fields both parallel and perpendicular to the geomagnetic field B0 within cavities,though the VLF E field increases were often not as large proportionally as seen in themagnetic fields. This behavior is opposite to that predicted by previously published theoriesof LHCs based on passive scattering of externally incident auroral hiss. We argue thatthe GEODESIC cavities are active wave generation sites capable of radiating VLF wavesinto the surrounding plasma and producing VLF saucers, with energy supplied by cold,upward flowing electron beams composing the auroral return current. This interpretation issupported by the observation that the most intense waves, both inside and outside cavities,occurred in regions where energetic electron precipitation was largely inhibited orabsent altogether. We suggest that the wave-enhanced cavities encountered by GEODESICwere qualitatively different from those observed by earlier spacecraft because of thefortuitous timing of the GEODESIC launch, which placed the payload at apogee within asubstorm-related return current during its most intense phase, lasting only a few minutes.

Knudsen, D. L.↗

The Formation and Maintenance of the Dominant Southern Polar Crown Cavity of Cycle 24

In this article, we report a study of the longest-lived polar crown cavity of Solar Cycle 24, using an observation from 2013, and propose a physical mechanism to explain its sustained existence. We used high temporal and spatial resolution observations from the Atmospheric Imaging Assembly (AIA) and the Helioseismic Magnetic Imager (HMI) instruments on board the Solar Dynamics Observatory (SDO) to explore the structure and evolution of the cavity. Although it existed for more than a year, we examined the circumpolar cavity in great detail from 2013 March 21 to 2013 October 31. Our study reinforces the existing theory of formation of polar crown filaments that involves two basic processes to form any polar crown cavity as well as the long-lived cavity that we studied here. First, the underlying polarity inversion line (PIL) of the circumpolar cavity is formed between (1) the trailing part of dozens of decayed active regions distributed in different longitudes and (2) the unipolar magnetic field in the polar coronal hole. Second, the long life of the cavity is sustained by the continuing flux cancellation along the PIL. The flux is persistently transported toward the polar region through surface meridional flow and diffusion. The continuing flux cancellation leads to the shrinking of the polar coronal hole.

Karna, N.↗

Effects of Cavity Diameter on Acoustic Impedance in a Complex Acoustic Environment

This paper investigates the effects of cavity diameter on the acoustic performance of conventional perforate-over-honeycomb liners. This investigation is a follow up to a previous study where it was demonstrated that the cavity diameter has a relatively small effect on the acoustic impedance for core cavity diameters up to 2.0 inches. In the current study, liner concepts are exposed to a complex acoustic environment, where higher-order modes are present. Four liner configurations are explored in this investigation, which include two cavity cores of different cavity diameters combined with two facesheets. These configurations are tested in the Grazing Flow Impedance Tube (GFIT) at Mach 0.0, 0.3, and 0.5 at a source sound pressure level of 150 dB. A comparison of the acoustic performance of these samples suggests that the cavity diameter has a relatively small effect on the acoustic impedance for core cavity diameters up to 2.0 inches at these conditions. These configurations are exposed to a more complex acoustic environment (e.g., higher-order modes) in the Curved Duct Test Rig (CDTR) at Mach 0.0 and 0.3.

Brown, M. C.↗

Novel Geometries for the LHC Crab Cavity

The planned luminosity upgrade to LHC is likely to necessitate a large crossing angle and a local crab crossing scheme. For this scheme crab cavities align bunches prior to collision. The scheme requires at least four such cavities, a pair on each beam line either side of the interaction point (IP). Upstream cavities initiate rotation and downstream cavities cancel rotation. Cancellation is usually done at a location where the optics has re-aligned the bunch. The beam line separation near the IP necessitates a more compact design than is possible with elliptical cavities such as those used at KEK. The reduction in size must be achieved without an increase in the operational frequency to maintain compatibility with the long bunch length of the LHC. This paper proposes a suitable superconducting variant of a four rod coaxial deflecting cavity (to be phased as a crab cavity), and presents analytical models and simulations of suitable designs.

43 PARTICLE ACCELERATORS↗

Q0 Improvement of Large-Grain Multi-Cell Cavities by Using JLab's Standard ILC EP Processing

As reported previously at the Berlin workshop, applying the JLab standard ILC electropolishing (EP) recipe on previously buffered chemical polishing (BCP) etched fine-grain multi-cell cavities results in improvement both in gradient and Q{sub 0}. We recently had the opportunity to experiment with two 1300 MHz 9-cell large-gain niobium cavities manufactured by JLab and Peking University. Both cavities were initially BCP etched and further processed by using JLab's standard ILC EP recipe. Due to fabrication defects, these two cavities only reached a gradient in the range of 20-30 MV/m. Interestingly both cavities demonstrated significant Q{sub 0} improvement in the gradient range of 15-20 MV/m. At 2K, a Q{sub 0} value of 2E10 is achieved at 20 MV/m. At a reduced temperature of 1.8K, a Q{sub 0} value of 3E10 is achieved at 20 MV/m. These results suggest that a possible path for obtaining higher Q{sub 0} in the medium gradient range is to use the large-grain material for cavity fabrication and EP and low temperature bake for cavity processing.

43 PARTICLE ACCELERATORS↗

Improving gradient and Q performance of BCP etched multi-cell cavities by applying a light EP

We have electropolishing (EP) processed several multi-cell cavities previously heavy buffered chemical polishing (BCP) etched. With a surprisingly light EP removal of less than 50 micron, all cavities have shown significant gradient and Q improvement. So far three cavities including two fine-grain niobium 7-cell CEBAF upgrade prototype cavities and one large-grain niobium 9-cell ILC cavities have been treated and tested. The two 7-cell cavities reached a quench limit (without field emission) of 35 MV/m and 25 MV/m, respectively. Another 7-cell cavity has been treated and is under RF test. We give a summary of the test results.

36 MATERIALS SCIENCE↗

HIGH POWER RF DISTRIBUTION AND CONTROL FOR MULTI-CAVITY CRYOMODULE TESTING

Qualification of the superconducting radio-frequency (SRF) cavities in the cryomodules for the accelerating performance needs to be done through high power processing. A four-way waveguide power distribution system with independent control of power outputs has been being developed for testing the multi-cavity cryomodules for the SNS linac. SNS is employing two types of cryomodules: one type with three medium beta six-cell cavities and the other with four high beta six-cell cavities. The cryomodule that is being manufactured as a spare and the new crymodules for the future power upgrade project (PUP) of SNS will be high beta types. The four-way power distribution with independently controlled power outputs was considered useful for powering all cavities at the same time with a klystron amplifier since the SNS test facility was configured for a single klystron operation. Since certain interaction between the cavities under severe field emission was suspected in existing cryomodules, this type of high power test can be valuable for characterization of SRF cavities. By implementing a vector modulator at each arm of the splitting system, the amplitudes and the phases of RF outputs can be controlled independently. This paper discusses the present status of the development.

Cryomodule↗

Cavity Design, Fabrication and Commission Performance of a 750MHz, 4-rod Separator for CEBAF 4-Hall Beam Delivery System

A short version of the original CEBAF normal conducting 4-rod separator cavity has been developed into a 750MHz one * since the concept of simultaneous 4-hall operation for CEBAF is introduced **. This work has been advanced further based on the EM design optimization, bench measurement and by conducting RF-thermal coupled simulation using CST and ANSYS to confirm the cavity tuning and thermal performance. The cavity fabrication used matured technology like copper plating and machining. The cavity flanges, couplers, tuners and cooling channels adopted consistent/compatible hardware with the existing 500MHz cavities. The electromagnetic and thermal design simulations have greatly reduced the prototyping and bench tuning time of the first prototype. Four production cavities have reached a typical 1.94MV kick voltage or 3.0kW wall loss on each cavity after a minor multipactoring or no processing, 7.5% overhead power than the design specification.

Wang, Haipeng↗

Multiphysics Analysis of Frequency Detuning in Superconducting RF Cavities for Proton Particle Accelerators

Multiphysics analyses for superconducting cavities are essential in the course of cavity design to meet stringent requirements on cavity frequency detuning. Superconducting RF cavities are the core accelerating elements in modern particle accelerators whether it is proton or electron machine, as they offer extremely high quality factors thus reducing the RF losses per cavity. However, the superior quality factor comes with the challenge of controlling the resonance frequency of the cavity within few tens of hertz bandwidth. In this paper, we investigate how the multiphysics analysis plays a major role in proactively minimizing sources of frequency detuning, specifically; microphonics and Lorentz Force Detuning (LFD) in the stage of RF design of the cavity and mechanical design of the niobium shell and the helium vessel.

43 PARTICLE ACCELERATORS↗

Radio frequency plasma method for uniform surface processing of RF cavities and other three-dimensional structures

A method for efficient plasma etching of surfaces inside three-dimensional structures can include positioning an inner electrode within the chamber cavity; evacuating the chamber cavity; adding a first inert gas to the chamber cavity; regulating the pressure in the chamber; generating a plasma sheath along the inner wall of the chamber cavity; adjusting a positive D.C. bias on the inner electrode to establish an effective plasma sheath voltage; adding a first electronegative gas to the chamber cavity; optionally readjusting the positive D.C. bias on the inner electrode reestablish the effective plasma sheath voltage at the chamber cavity; etching the inner wall of the chamber cavity; and polishing the inner wall to a desired surface roughness.

36 MATERIALS SCIENCE↗

Resonator modes and mode dynamics for an external cavity-coupled laser array

Employing a Fox-Li approach, we derived the cold-cavity mode structure and a coupled mode theory for a phased array of N single-transverse-mode active waveguides with feedback from an external cavity. We applied the analysis to a system with arbitrary laser lengths, external cavity design and coupling strengths to the external cavity. The entire system was treated as a single resonator. The effect of the external cavity was modeled by a set of boundary conditions expressed by an N-by-N frequency-dependent matrix relation between incident and reflected fields at the interface with the external cavity. The coupled mode theory can be adapted to various types of gain media and internal and external cavity designs.

Nair, Niketh S.↗