Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Enhancement of phase change material hysteresis model: A case study of modeling building envelope in EnergyPlus

Nowadays, buildings are expected to offer demand side services to the power grid to enhance the electrical load flexibility, which leads to the concepts of grid-interactive efficient buildings (GEBs). Phase change material (PCM)-based thermal energy storage has seen increasing attention in recent years for peak load shifting of grid-interactive efficient buildings (GEBs). Numerical models are critical tools for design and evaluation of PCM-integrated systems. Most industrial-grade PCMs are reported to melt/freeze over a temperature range instead of at a unique temperature. Such thermal hysteresis effect significantly affects the reliability of simulation results because not only the heat transfer process depends on melting and freezing temperatures, the PCM thermal properties change significantly during the phase change process as well. This study is aimed to develop a model for the PCMs used in the building envelope with the capability to accurately simulate hysteretic behaviors. Further, this model is based on a two-phase assumption and is implemented in a whole building energy performance simulation program (i.e., EnergyPlus). A comparison between numerical results and experimental data shows that during a complete phase transition, the two-phase model could achieve a good agreement with the experimental data. During a partial phase transition, the two-phase model could lead to significant improvements compared to other alternative PCM models, including the existing PCM model in EnergyPlus. Last, whole building simulations were performed to study this model's performance regarding heating/cooling loads and zone mean air temperature of a given building. The results show that the difference in hourly heating/cooling loads introduced by the models was less than 1% in design conditions, while significant changes were observed in both hourly heating/cooling loads and zone mean air temperature when the PCM envelope underwent partial phase transition processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Chicago microclimate and building energy use data

These data comprise three elements: - High resolution, 90 m simulated weather data for 1 year at 15 min. intervals (with known gaps toward the end of each month). These files are in .csv format. - A mapping of individual buildings with individual IDs, their latitude/longitude location, and height. (Excel file) - Energy simulation output of these individual buildings, at 15 min. intervals for a whole year. (.json and other files)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Chicago microclimate and building energy use data

These data comprise three elements: - High resolution, 90 m simulated weather data for 1 year at 15 min. intervals (with known gaps toward the end of each month). These files are in .csv format. - A mapping of individual buildings with individual IDs, their latitude/longitude location, and height. (Excel file) - Energy simulation output of these individual buildings, at 15 min. intervals for a whole year. (.json and other files)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Machine-learning modeling of magnetization dynamics in quasi-equilibrium and driven metallic spin systems

Here, we present a perspective on recent progress in machine-learning (ML) force-field approaches for large-scale Landau–Lifshitz–Gilbert (LLG) simulations of metallic spin systems. Building on a generalization of the Behler–Parrinello (BP) architecture originally developed for quantum molecular dynamics, we develop scalable and transferable ML models that faithfully capture the complex, environment-dependent electron-mediated exchange fields characteristic of itinerant magnets. A central ingredient of this framework is the implementation of symmetry-aware magnetic descriptors based on group-theoretical bispectrum formalisms. Leveraging these ML force fields, LLG simulations faithfully reproduce hallmark non-collinear magnetic orders—such as the 120° and tetrahedral states—on the triangular lattice, and successfully capture the complex spin textures emerging in the mixed-phase states of a square-lattice double-exchange model under thermal quench. We further discuss a generalized potential theory that extends the BP formalism to incorporate both conservative and nonconservative electronic torques, thereby enabling ML models to learn nonequilibrium exchange fields from computationally demanding microscopic approaches such as nonequilibrium Green’s-function techniques. This extension yields quantitatively accurate predictions of voltage-driven domain-wall motion and establishes a foundation for quantum-accurate, multiscale modeling of nonequilibrium spin dynamics and spintronic functionalities.

Descriptors↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Capabilities of Behind-the-Meter Solar-plus-Storage for Providing Backup Power during Long-Duration Power Interruptions [Slides]

The study estimates the performance of behind-the-meter solar PV-plus-energy-storage-systems (PVESS) in providing critical-load or whole-building backup across a wide range of geographies, building types, and power interruption conditions. The study also considers a set of 10 historical long-duration power outage events and evaluates how PVESS could have performed in providing backup power during those specific events. The analysis is the first in what will be a series of studies by Berkeley Lab, in collaboration with the National Renewable Energy Laboratory, on the use of PVESS for backup power. This initial study, which relies on simulated end-use level building loads, solar generation, and storage dispatch, is intended to provide a baseline set of performance estimates and to illustrate key performance drivers.

14 SOLAR ENERGY↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Failure investigation of nuclear grade POCO graphite target in high energy neutrino physics through numerical simulation

In many high energy physics neutrino beamlines, targets are made up of isotropic POCO graphite grade for production of neutrinos for high energy particle physics research and are bombarded with highly energetic pulsed proton beam. The pulsed proton beam with a small beam size creates thermal stress waves as well as radiation damage such as displacement damage, void formation, swelling, and gas formation amongst others. As a result, after a few years of operation one of the longest operated targets appears to have undergone bulk swelling and fractured along the beam centerline. A complex interaction of dynamic loading due to beam, material degradation due to irradiation are thought to have caused such a failure. Here, we present a numerical simulation to capture the combined effects of swelling and the dynamic effect of thermal stress waves due to beam heating, to explain the failure of target. An empirical formula has been developed to take into account swelling as a function of temperature and proton fluence and has been implemented in a commercial finite element code. Extensive X-ray diffraction (XRD) were performed on graphite samples from the failed target to understand the lattice parameter changes due to irradiation and build a valid empirical model. Simulation results show that swelling plays a major role in elevating the stress state in the material exceeding the failure strength while the pulsed beam heating also introduces fatigue loading that would explain brittle fracture emanating from inside of the material and propagating outward. Such empirical formulations will help in identifying the threshold values of critical parameters to extend the service life of future multi-megawatt neutrino targets and targets in other accelerator environments.

43 PARTICLE ACCELERATORS↗

Evaluating Energy Savings Measures for Building Retrofits in an Interactive Workshop Environment

As part of the Better Buildings Summit 2025, a workshop was developed to simulate the decision process for implementing a set of energy savings measures on an existing building. As part of the workshop a "game" was created around energy savings strategies, and workshop participants selected renovation cards that provided data around the impacts of that renovation choice. Participants then were able to calculate overall savings and payback from the selected retrofit opportunities. This publication has been produced to package the resources used in the activity in an organized document so that the materials can be distributed and reused more broadly. It provides a comprehensive framework for replicating the workshop, including step-by-step instructions, retrofit "game cards" with data points, and facilitation guidance. By using these materials, readers can conduct their own version of this interactive workshop with stakeholders in their networks, such as building owners, energy managers, or policy makers. The goal is to empower users to simulate the decision-making processes for energy projects, foster collaboration, and drive meaningful discussions around cost-effective retrofit opportunities and goal-oriented outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Ensemble Generation for Improved Characterization of Representing Geologic Variability in a Reservoir: IBDP Case Study for SMART Initiative

This document is a poster covering the findings from activities on training data generation, specifically geologic ensemble generation. The generated geologic realizations captured the range of possible permeability distributions of the subsurface at the Illinois Basin - Decatur Project (IBDP) site, based on available well log variabilities. The percentages of reservoirs and baffles in the injection zone and a truncation of baffle permeability led to more variance in the simulations. This will be used to build forward modeling, history matching, and optimization workflows. The geologic realizations were also ranked according to dynamic measures of hydraulic diffusivity, and simulations confirm a greater contrast between the reservoir and the baffles during injection.

stochastic ensemble generation↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning in Buildings: Implicit Assumptions and their Impact

As deep reinforcement learning (DRL) continues to gain interest in the smart building research community, there is a transition from simulation-based evaluations to deploying DRL control strategies in actual buildings. While the efficacy of a solution could depend on a particular implementation, there are common obstacles that developers have to overcome to deliver an effective controller. Additionally, a deployment in a physical building can invalidate some of the assumptions made during the controller development. Assumptions on the sensor placement or on the equipment behavior can quickly come undone. This paper presents some of the significant assumptions made during the development of DRL based controllers that could affect their operations in a physical building. Furthermore, a preliminary evaluation revealed that controllers developed with some of these assumptions can incur twice the expected costs when they are deployed in a building.

Prakash, Anand Krishnan↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

pnnl/simple-building-calculator

The Simple Building Calculator is a web application that estimates annual energy use using regression models that have been fit to simulation results for the DOE Commercial Prototype Building Models. The tool is a single-page application that will allow a user to rapidly analyze the impact of energy efficiency measures and design options on building performance. As it uses linear regression models rather than more complicated machine learning models or physics based simulation, the tool can deploy easily and run client-side.

Xu, Weili↗