Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOLOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

THIS: A Next Generation Tuneable Heterodyne Infrared Spectrometer for SOFIA

A new infrared heterodyne instrument has been developed which allows the use of both tuneable diode lasers (TDL) and quantum cascade lasers (QCL) as local oscillators (LO). The current frequency tuning range of our system extends from 900 to 1100/cm depending on the availability of lasers but is planned to be extended to 600/cm soon. The IF-bandwidth is 1.4 GHz using an acousto-optical spectrometer (AOS). The frequency resolution and stability of the system is approximately 10(exp 7). Currently, mercury-cadmium-telluride (MCT) detectors are used as mixers while new devices like quantum-well-infrared-photodetectors (QWIP) and hot-electron-bolometers (HEB) are investigated. The IF-bandwidth can be extended to about 3 GHz by using a new broadband acousto-optical spectrometer presently under development. The instrument is fully transportable and can be attached to any infrared or optical telescope. The semiconductor laser is stabilized to a Fabry-Perot ring-resonator, which is also used as an efficient diplexer to superimpose the local-oscillator and the signal radiation. As a first step measurements of trace gases in Earth's atmosphere and non-LTE emission from Venus' atmosphere were carried out as well as observations of molecular features in sunspots. Further astronomical observations from ground-based telescopes and the airborne observatory SOFIA are planned for the future. Of particular interest are molecules without a permanent dipole moment like H2, CH4, C2H2 etc.

Sonnabend, Guido↗

The Case for Space-Borne Far-Infrared Line Surveys

The combination of sensitive direct detectors and a cooled aperture promises orders of magnitude improvement in the sensitivity and survey time for far-infrared and submillimeter spectroscopy compared to existing or planned capabilities. Continuing advances in direct detector technology enable spectroscopy that approaches the background limit available only from space at these wavelengths. Because the spectral confusion limit is significantly lower than the more familiar spatial confusion limit encountered in imaging applications, spectroscopy can be carried out to comparable depth with a significantly smaller aperture. We are developing a novel waveguide-coupled grating spectrometer that disperses radiation into a wide instantaneous bandwidth with moderate resolution (R ~ 1000) in a compact 2-dimensional format. A line survey instrument coupled to a modest cooled single aperture provides an attractive scientific application for spectroscopy with direct detectors. Using a suite of waveguide spectrometers, we can obtain complete coverage over the entire far-infrared and sub-millimeter. This concept requires no moving parts to modulate the optical signal. Such an instrument would be able to conduct a far-infrared line survey 10 6 times faster than planned capabilities, assuming existing detector technology. However, if historical improvements in bolometer sensitivity continue, so that photon-limited sensitivity is obtained, the integration time can be further reduced by 2 to 4 orders of magnitude, depending on wavelength. The line flux sensitivity would be comparable to ALMA, but at shorter wavelengths and with the continuous coverage needed to extract line fluxes for sources at unknown redshifts. For example, this capability would break the current spectroscopic bottleneck in the study of far-infrared galaxies, the recently discovered, rapidly evolving objects abundant at cosmological distances.

Bock, J. J.↗

The Millimeter-Wave Bolometric Interferometer

The Millimeter-wave Bolometric Interferometer (MBI) is a proposed ground-based instrument designed for a wide range of cosmological and astrophysical observations including studies of the polarization of the cosmic microwave background (CMB). MBI combines the advantages of two well-developed technologies - interferometers and bolometric detectors. Interferometers have many advantages over .filled-aperture telescopes and are particularly suitable for high resolution imaging. Cooled bolometers are the highest sensitivity detectors at millimeter and sub-millimeter wavelengths. The combination of these two technologies results in an instrument with both high sensitivity and high angular resolution.

Ali, S.↗

BLAST: The Balloon-Borne Large Aperture Submillimeter Telescope

BLAST is the Balloon-borne Large-Aperture Sub-millimeter Telescope. It will fly from a Long Duration Balloon (LDB) platform from Antarctica. The telescope design incorporates a 2 m primary mirror with large-format bolometer arrays operating at 250, 350 and 500 microns. By providing the first sensitive large-area (10 sq. deg.) sub-mm surveys at these wavelengths, BLAST will address some of the most important galactic and cosmological questions regarding the formation and evolution of stars, galaxies and clusters. Galactic and extragalactic BLAST surveys will: (1) identify large numbers of high-redshift galaxies; (2) measure photometric redshifts, rest-frame FIR luminosities and star formation rates thereby constraining the evolutionary history of the galaxies that produce the FIR and sub-mm background; (3) measure cold pre-stellar sources associated with the earliest stages of star and planet formation; (4) make high-resolution maps of diffuse galactic emission over a wide range of galactic latitudes. In addition to achieving the above scientific goals, the exciting legacy of the BLAST LDB experiment will be a catalogue of 3000-5000 extragalactic sub-mm sources and a 100 sq. deg. sub-mm galactic plane survey. Multi-frequency follow-up observations from SIRTF, ASTRO-F, and Herschel, together with spectroscopic observations and sub-arcsecond imaging from ALMA are essential to understand the physical nature of the BLAST sources.

Devlin, Mark↗

Slit Function Measurement of An Imaging Spectrograph Using Fourier Transform Techniques

Knowledge of a spectrograph slit function is necessary to interpret the unresolved lines in an observed spectrum. A theoretical slit function can be calculated from the sizes of the entrance slit, the detector aperture when it functions as an exit slit, the dispersion characteristic of the disperser, and the point spread function of the spectrograph. A measured slit function is preferred to the theoretical one for the correct interpretation of the spectral data. In a scanning spectrometer with a single exit slit, the slit function is easily measured. In a fixed grating/or disperser spectrograph, illuminating the entrance slit with a near monochromatic light from a pre-monochrmator or a tunable laser and varying the wavelength of the incident light can measure the slit function. Even though the latter technique had been used successfully for the slit function measurements, it had been very laborious and it would be prohibitive to an imaging spectrograph or a multi-object spectrograph that has a large field of view. We explore an alternative technique that is manageable for the measurements. In the proposed technique, the imaging spectrograph is used as a detector of a Fourier transform spectrometer. This method can be applied not only to an IR spectrograph but also has a potential to a visible/UV spectrograph including a wedge filter spectrograph. This technique will require a blackbody source of known temperature and a bolometer to characterize the interferometer part of the Fourier Transform spectrometer. This pa?er will describe the alternative slit function measurement technique using a Fourier transform spectrometer.

Park, Hongwoo↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗

Wide Operational Range Thermal Sensor

Bolometer system and method for detecting, at BLIP levels, presence of radiation over a broad range of wavelengths in an infrared spectrum and in a temperature range from 20 K to as high as room temperature. The radiation is received by a Si crystal having a region that is doped with one or more of In, Ga, S, Se, Te, B, Al, P, As and Sb in a concentration ratio in a range such as 5 x 10(exp -11) to 5 x 10(exp -6). Change in electrical resistance delta R due to receipt of the radiation is measured through a change in voltage difference or current within the crystal, and the quantity delta R is converted to an estimate of the amount of radiation received. Optionally, incident radiation having an energy high enough to promote photoconductivity is removed before detection.

John H Goebel↗

Evaluation of Microbolometer-Based Thermography for Gossamer Space Structures

In August 2003, NASA's In-Space Propulsion Program contracted with our team to develop a prototype on-board Optical Diagnostics System (ODS) for solar sail flight tests. The ODS is intended to monitor sail deployment as well as structural and thermal behavior, and to validate computational models for use in designing future solar sail missions. This paper focuses on the thermography aspects of the ODS. A thermal model was developed to predict local sail temperature variations as a function of sail tilt to the sun, billow depth, and spectral optical properties of front and back sail surfaces. Temperature variations as small as 0.5 C can induce significant thermal strains that compare in magnitude to mechanical strains. These thermally induced strains may result in changes in shape and dynamics. The model also gave insight into the range and sensitivity required for in-flight thermal measurements and supported the development of an ABAQUS-coupled thermo-structural model. The paper also discusses three kinds of tests conducted to 1) determine the optical properties of candidate materials; 2) evaluate uncooled microbolometer-type infrared imagers; and 3) operate a prototype imager with the ODS baseline configuration. (Uncooled bolometers are less sensitive than cooled ones, but may be necessary because of restrictive ODS mass and power limits.) The team measured the spectral properties of several coated polymer samples at various angles of incidence. Two commercially available uncooled microbolometer imagers were compared, and it was found that reliable temperature measurements are feasible for both coated and uncoated sides of typical sail membrane materials.

Miles, Jonathan J.↗

Spectrometer Technology Development for Far-Infrared Line Surveys

The objective of this proposal was to build and demonstrate a new direct-detection diffraction grating concept and couple it to an array of bolometers. The spectrometer was to be built around a parallel-plate waveguide diffraction grating, WaFIRS: Waveguide Far-InfraRed Spectrometer. The grating is two dimensional in nature, which provides a compact configuration to suit NASA s needs for cryogenic spectrometers for future opportunities, such as infrared/submillimeter spectrometers for a suborbital balloon platform, for SOFIA, for SPICA (a Japanese satellite), and for SAFIR. Our goal was to build a spectrometer (Z-Spec) for 1.0 - 1.5 mm and demonstrate spectral resolution, throughput, and background-limited performance. This grant would partially cover the expenses and we were subsequently awarded a second grant, NAGS-12788, to complete the project. We have one-year received a no-cost extension on NAG.5-12788, to be completed in 3/31/06.

Glenn, Jason↗

Improved equivalent circuit for twin slot terahertz receivers

Series-fed coplanar waveguide embedding circuits are being developed for terahertz mixers using, in particular, submicron-sized superconducting devices, such as hot electron bolometers as the nonlinear element. Although these mixers show promising performance, they usually also show a considerable downward shift in the center frequency, when compared with simulations obtained by using simplified models. This makes it very difficult to design low-noise mixers for a given THz frequency. This shiftis principally caused by parasitics due to the extremely small details (in terms of wavelength) of the device, and by the electrical properties of the RF choke filter in the DC/IF line. In this paper, we present an improved equivalent network model of such mixer circuits which agrees with measured results at THz frequencies and we propose a new set of THz bolometric mixers that have been fabricated and are currently being tested.

HEB slot antennas CPW↗

10-30 micrometer Maps of the Central 5 parsecs of the Galaxy: Heating of the Cavity and Neutral-Gas Disk

Maps are presented for 10, 20, and 30 micrometers of the central 60' X 90' (RA X Dec) of the galaxy made at approximately 4' resolution with the MSFC bolometer array. The maps are the first to show the thermal emission from dust particles in both the ionized cavity and the neutral-gas ring with high sensitivity and an angular resolution as good as several arcsec.

galaxies galaxy center infrared astronomy↗

1400-1900 GHz local oscillators for the Herschel Space Observatory

JPL continues to develop robust planar, all solid-state sources to cover the 1414 to 1908 GHz band. These sources will be used as local oscillators to drive hot electron bolometer (HEB) heterodyne mixers on the Herschel Space Observatory to observe high resolution spectra in the interstellar medium. We report our current progress and present recent results.

Schottky diode frequency multiplier THz local osci↗

Tunable All-Solid-State Local Oscillators to 1900 GHz

We present a status report of an ongoing effort to develop robust tunable all-solid-state sources up to 1900 GHz for the Heterodyne Instrument for the Far Infrared (HIFI) on the Herschel Space Observatory. GaAs based multi-chip power amplifier modules at W-band are used to drive cascaded chains of multipliers. We have demonstrated performance from chains comprised of four doublers up to 1600 GHz as well as from a x2x3x3 chain to 1900 GHz. Measured peak output power of 23 (micro)W at 1782 GHz and 2.6 (micro)W at 1900 GHz has been achieved when the multipliers are cooled to 120K. The 1900 GHz tripler was pumped with a four anode tripler that produces a peak of 4 mW at 630 GHz when cooled to 120 K. We believe that these sources can now be used to pump hot electron bolometer (HEB) heterodyne mixers.ter (HEB) heterodyne mixers.

local oscillator↗

The QUaD (QUEST at DASI) Experiment

The QUaD (QUEST at DASI) experiment is a millimeter-wave polarimeter designed to probe the cosmic microwave background (CMB) polarization over a multipole range of 100 to 2500. QUaD observes the CMB with an array of 3 1 polarization-sensitive bolometers split between two frequency bands centered at 100 and 150-GHz. The telescope is a 2.6 m on-axis Cassegrain design with beam sizes of 6.3' and 4.2' at the two respective observing frequencies. QUaD was commissioned at the South Pole in the Austral summer of 2004/2005. It has since completed two full seasons of observations with a third season underway. I will report on the status of QUaD observations and analysis. QUaD is a collaboration between institutions in the US, the UK and Ireland and is funded by the NSF, PPARC and Enterprise Ireland.

Hinderks, James↗

Fabrication of a Thermally Isolated and Pre-amplified Transistor Module with Polyimide Micro-wires for Cryogenic Detectors

For use in cryogenic applications such as bolometer and x-ray microcalorimeter arrays, pre-amplifying Junction Field Effect Transistors (JFETs) are often required for the readout electronics. The optimum operating temperature of the JFETs is 130 Kelvin while the cryogenic detectors operate in the milli-Kelvin range. Thus, the JFETs must be heated up but thermally isolated from the surrounding cryogenic instruments. In the past, the thermal isolation was accomplished by suspending the JFETs with low conductance wires such as manganium or stainless steel on a Kevlar support platform [I]. This also achieved electrical connections. However, this assembly required manual soldering work, which could raise a reliability issue for the cryogenic applications. In order to eliminate the manual work, polyimide micro-wires were developed [2]. The wires must be of sufficient length to decrease the heat load and in tension to prevent microphonic noise from vibration of the wires: the polyimide wires were patterned into llS"shaped curves over a thin metal wires such as aluminum, titanium, or niobium. The bilayer of the films were then suspended by etching silicon substrate thus to make freestanding air bridges (enough explanation?). In this paper, we present a method to fabricate micromachined JFET mechanical modules suspended by polyimide Pyraline micro-wires and heated up with built-in aluminum micro-heaters.

Oh, L. H.↗

THz Local Oscillator Technology

The last decade has seen a number of technological advancements that have now made it possible to implement fully solid state local oscillator chains up to 2 THz. These chains are composed of cascaded planar multiplier stages that are pumped with W-band high power sources. The high power W-band sources are achieved by power combining MMIC amplifiers and can provide in access of 150 mW with about 10% bandwidth. Planar diode technology has also enabled novel circuit topologies that can take advantage of the high input power and demonstrate significant efficiencies well into the THz range. Cascaded chains to 1.9 THz have now been demonstrated with enough output power to successfully pump hot-electron bolometer mixers in this frequency range. An overview of the current State-of-the-Art of the local oscillator technology will be presented along with highlighting future trends and challenges.

multipliers↗