Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Cardiac Metastasis from Invasive Thymoma Via the Superior Vena Cava: Cardiac MRI Findings

Cardiac tumors are rare, and metastatic deposits are more common than primary cardiac tumors. We present cardiac magnetic resonance imaging (MRI) findings of a 50-year-old woman with invasive thymoma. Cardiac MRI revealed a heterogeneous, lobulated anterior mediastinal mass invading the superior vena cava and extending to the right atrium. In cine images there was no invasion to the right atrial wall.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Traumatic Inferior Gluteal Artery Pseudoaneurysm and Arteriovenous Fistula Managed with Emergency Transcatheter Embolization

We present a case of blunt trauma to the buttock resulting in an inferior gluteal artery pseudoaneurysm and arteriovenous fistula. The characteristic diagnostic features on CT angiography and digital subtraction angiography (DSA), along with the emergency percutaneous management of this traumatic vascular injury, are described. A review of the literature demonstrates inferior gluteal artery pseudoaneurysm is a rare condition, while successful treatment with glue embolization is previously unreported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution

A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infective organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Right Renal Vein Aplasia Associated With Diverted Renal Venous Drainage Through Lower Pole

We report a unique anomalous renal venous drainage on a 25-year-old man who had congenital absence of the right renal vein and an aberrant venous drainage through the lower pole of the kidney into the inferior vena cava. To our knowledge, this anomaly has not been previously reported in the peer-reviewed literature. State-of-the-art imaging findings are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Primary Iliac-Cecal Fistula Presenting with Gastrointestinal Hemorrhage

We report a case of an arterio-enteric fistula between an external iliac artery aneurysm and otherwise healthy cecum, presenting with torrential hemorrhage per rectum in an 85-year-old patient. Whilst fistulization to the aorta and common iliac arteries has been reported, to our knowledge no previous cases of primary fistulization between an external iliac aneurysm and normal cecum have been. Successful endovascular exclusion of the aneurysm was undertaken with a Wallgraft covered stent and the patient remains well at 1 year.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Error During Deployment Leads to Vena Cava Filter Migration and Massive Pulmonary Embolism

The Guenther Tulip vena cava filter is a safe, effective, well-established device for pulmonary embolism prophylaxis. We report a patient in whom there was migration of the filter to the right atrium, 2 weeks after insertion, caused by a technical error during deployment. An attempt to retrieve the filter percutaneously failed, necessitating removal at open-heart surgery. The potential causes of migration are described and the lessons learned from this unusual case are outlined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Common Iliac Occlusion in the Presence of Persistent Sciatic Artery

Persistent sciatic artery is a rare congenital anomaly. It is associated with increased incidence of aneurysmal dilatation, thrombosis, distal embolization, and atherosclerotic change. We describe the case of a patient with persistent sciatic artery who presented with a critically ischemic left leg as a result of an occluded left common iliac artery, which was treated by angioplasty and stenting, and discuss the endovascular iliac recanalization in the presence of a persistent sciatic artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crossing Ureteric Strictures: Microcatheters to the Rescue When Conventional Methods Fail

Tight distal ureteric strictures can be most challenging to traverse both from above, by interventional radiologists, and below, by urologists. Despite the advent of numerous guidewires, manufactured from different materials, often ureteric strictures are too tight to allow conventional guidewires to pass through. We describe an alternative approach to cross tight ureteric strictures, using a microguidewire and microcatheter combination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inferior Vena Cava Filter from Left-Sided Superior Vena Cava

We describe the unusual case of a 71-year-old male with a history of deep vein thrombosis and recurrent multiple pulmonary embolism (PE) despite adequate anticoagulation. Computed tomography (CT) and brachiocephalic venography revealed a left-sided superior vena cava. We describe successful placement of an inferior vena cava filter via a left-sided superior vena cava.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Management of Massive Hemothorax Due to Inadvertent Puncture of an Aberrant Right Subclavian Artery

We report a case of massive hemothorax due to inadvertent puncture of an aberrant right subclavian artery during central venous access. Iatrogenic laceration at the origin of the right internal thoracic artery was successfully treated with coil embolization of the internal thoracic artery followed by stent-graft placement into the subclavian artery. Due to its elongated and abnormal course, an aberrant right subclavian artery may predispose to inadvertent puncture during vein catheterization and should be recognized as a potential threat for such procedures. Our case emphasizes that ultrasound guidance should be used routinely for central venous lines wherever possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Appropriateness of Renal Angioplasty. The ANPARIA Software: A Multidisciplinary Expert Panel Approach

Percutaneous transluminal renal angioplasty (PTRA) is an invasive technique that is costly and involves the risk of complications and renal failure. The ability of PTRA to reduce the administration of antihypertensive drugs has been demonstrated. A potentially greater benefit, which nevertheless remains to be proven, is the deferral of the need for chronic dialysis. The aim of the study (ANPARIA) was to assess the appropriateness of PTRA to impact on the evolution of renal function. A standardized expert panel method was used to assess the appropriateness of medical treatment alone or medical treatment with revascularization in various clinical situations. The choice of revascularization by either PTRA or surgery was examined for each clinical situation. Analysis was based on a detailed literature review and on systematically elicited expert opinion, which were obtained during a two-round modified Delphi process. The study provides detailed responses on the appropriateness of PTRA for 1848 distinct clinical scenarios. Depending on the major clinical presentation, appropriateness of revascularization varied from 32% to 75% for individual scenarios (overal 48%). Uncertainty as to revascularization was 41% overall. When revascularization was appropriate, PTRA was favored over surgery in 94% of the scenarios, except in certain cases of aortic atheroma where sugery was the preferred choice. Kidney size >7 cm, absence of coexisting disease, acute renal failure, a high degree of stenosis ({>=}70%), and absence of multiple arteries were identified as predictive variables of favorable appropriateness ratings. Situations such as cardiac failure with pulmonary edema or acute thrombosis of the renal artery were defined as indications for PTRA. This study identified clinical situations in which PTRA or surgery are appropriate for renal artery disease. We built a decision tree which can be used via Internet: the ANPARIA software (http://www.chu-clermontferrand.fr/anpariahttp://www.chu-clermontferrand.fr/anparia/). In numerous clinical situations uncertainty remains as to whether PTRA prevents deterioration of renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonary embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In conclusion, there was an increase in the use of retrievable filters over the study period and an overall increase in the total number of filters implanted. The increased use of these filters appeared to be due to expanded indications predicated by their retrievability. Placement and retrieval of these filters have a low risk of complications, and retrievable filters appeared effective, as there was low rate of clinically significant pulmonary embolism associated with these filters during their indwelling time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent-Graft for the Management of Hepatic Artery Rupture Subsequent to Transcatheter Thrombolysis and Angioplasty in a Liver Transplant Recipient

Arterial rupture subsequent to angioplasty occurs in about 5% of cases. Thrombolysis with re-establishment of flow without resolving underlying anatomic defects such as hepatic arterial stenosis leads to re-thrombosis. We present a case of arterial anastomotic rupture after thrombolysis and angioplasty of an underlying anastomotic hepatic arterial stenosis. Both the underlying anatomic defect and the rupture were resolved successfully with placement of a stent-graft, with a resultant patent artery for 1 year after the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗