Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

LV software for supersonic flow analysis

The NASA Lewis Research Center (LeRC) maintains a leadership position in research into advanced aerospace propulsion systems. For the next generation of aircraft, engine designs continue to involve complex, high-speed flows. Performing the detailed flow diagnostics to properly evaluate these designs requires advanced instrumentation to probe these highly turbulent flows. The hostile flow environment often requires nonintrusive measurement techniques such as the laser velocimeter (LV). Since the LV is a proven instrument for nonintrusive flow measurement, it can provide quantitative velocity data with minimal interference to the flow. Based on anticipated flow conditions, laser velocimeter systems were procured from TSI, Inc. The initial system utilized counter processor technology, but later procurements this past year include a more advanced, correlator-based processor, which significantly improves the overall LV performance. To meet the needs of advanced research into propulsion, this instrument must be integrated into an existing VAX/VMS computer system for data acquisition, processing, and presentation. The work done under this grant before this period concentrated on developing the software required to setup and acquire data from the TSI MI-990 multichannel interface, and the RMR 1989 rotating machinery resolver. With the basis established for controlling the operation of the LV system, software development this past year shifted in emphasis from instrumentation control and data acquisition to data analysis and presentation. The progress of the program is reported.

Bell, William A.↗

Novel Temperature Sensors and Wireless Telemetry for Active Condition Monitoring of Advanced Gas Turbines

The objective of the program is to develop and engine test hardware and software technologies that will enable active condition monitoring to be implemented on hot gas path turbine blades in large industrial gas turbines. The specific objectives are (1) to fabricate and install Smart Turbine Blades with thermally sprayed sensors and high temperature wireless telemetry systems in a gas turbine engine, (2) to integrate the component engine test data with remaining useful life (RUL) models and develop an approach for networking the component RUL data with Siemens' Power Diagnostics® engine monitoring system. These significant advances carried out in Phase 1 in temperature wide bandgap telemetry, along with new induced power driver and receiver geometry combined with an innovative approach to transmit digital data wirelessly will enable the opportunity to proceed with more technical innovation. The Phase 2 program focused on validation testing of sensor-wireless telemetry package in spin rig and advanced operation-based assessment (OBA) model utilizing artificial intelligence. Significant efforts were dedicated on the download of the technology onto components to be tested an actual gas turbine engine for full realization of active condition monitoring for Smart Turbine Blades.

03 NATURAL GAS↗

Performance of JT-60SA divertor Thomson scattering diagnostics

For the satellite tokamak JT-60 Super Advanced (JT-60SA), a divertor Thomson scattering measurement system is planning to be installed. In this study, we improved the design of the collection optics based on the previous one, in which it was found that the solid angle of the collection optics became very small, mainly because of poor accessibility to the measurement region. By improvement, the solid angle was increased by up to approximately five times. To accurately assess the measurement performance, background noise was assessed using the plasma parameters in two typical discharges in JT-60SA calculated from the SONIC code. Moreover, the influence of the reflection of bremsstrahlung radiation by the wall is simulated by using a ray tracing simulation. The errors in the temperature and the density are assessed based on the simulation results for three typical field of views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EMISSION SIGNATURES FROM SUB-PARSEC BINARY SUPERMASSIVE BLACK HOLES. I. DIAGNOSTIC POWER OF BROAD EMISSION LINES

Motivated by advances in observational searches for sub-parsec supermassive black hole binaries (SBHBs) made in the past few years, we develop a semi-analytic model to describe spectral emission-line signatures of these systems. The goal of this study is to aid the interpretation of spectroscopic searches for binaries and to help test one of the leading models of binary accretion flows in the literature: SBHB in a circumbinary disk. In this work, we present the methodology and a comparison of the preliminary model with the data. We model SBHB accretion flows as a set of three accretion disks: two mini-disks that are gravitationally bound to the individual black holes and a circumbinary disk. Given a physically motivated parameter space occupied by sub-parsec SBHBs, we calculate a synthetic database of nearly 15 million broad optical emission-line profiles and explore the dependence of the profile shapes on characteristic properties of SBHBs. We find that the modeled profiles show distinct statistical properties as a function of the semimajor axis, mass ratio, eccentricity of the binary, and the degree of alignment of the triple disk system. This suggests that the broad emission-line profiles from SBHB systems can in principle be used to infer the distribution of these parameters and as such merit further investigation. Calculated profiles are more morphologically heterogeneous than the broad emission lines in observed SBHB candidates and we discuss improved treatment of radiative transfer effects, which will allow a direct statistical comparison of the two groups.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional quantitative flow diagnostics

The principles, capabilities, and practical implementation of advanced measurement techniques for the quantitative characterization of three-dimensional flows are reviewed. Consideration is given to particle, Rayleigh, and Raman scattering; fluorescence; flow marking by H2 bubbles, photochromism, photodissociation, and vibrationally excited molecules; light-sheet volume imaging; and stereo imaging. Also discussed are stereo schlieren methods, holographic particle imaging, optical tomography, acoustic and magnetic-resonance imaging, and the display of space-filling data. Extensive diagrams, graphs, photographs, sample images, and tables of numerical data are provided.

Miles, Richard B.↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

Correlation function metrology for warm dense matter: Recent developments and practical guidelines

X-ray Thomson scattering (XRTS) has emerged as a valuable diagnostic for matter under extreme conditions, as it captures the intricate many-body physics of the probed sample. Recent advances, such as the model-free temperature diagnostic of Dornheim et al. [Nat. Commun. 13 , 7911 (2022)], have demonstrated how much information can be extracted directly within the imaginary-time formalism. However, since the imaginary-time formalism is a concept often difficult to grasp, we provide here a systematic overview of its theoretical foundations and explicitly demonstrate its practical applications to temperature inference, including relevant subtleties. Furthermore, we present recent developments that enable the determination of the absolute normalization, Rayleigh weight, and density from XRTS measurements without reliance on uncontrolled model assumptions. Finally, we outline a unified workflow that guides the extraction of these key observables, offering a practical framework for applying the method to interpret experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy of Fukuoka and American Gastroenterological Association Guidelines for Predicting Advanced Neoplasia in Pancreatic Cyst Neoplasm: A Meta-Analysis

Background: A differential diagnosis of advanced pancreatic cystic neoplasms (PCNs) is critical to determine optimal treatment. The Fukuoka and American Gastroenterological Association (AGA) guidelines are the most widely accepted criteria for the management of PCNs. Objective: This study aimed to evaluate the diagnostic value of these guidelines in predicting advanced neoplasia (AN). Methods: A comprehensive electronic search of the PubMed, EMBASE, Web of Science, Cochrane Library, and Scopus databases was conducted to identify all relevant studies evaluating the Fukuoka and AGA guidelines in surgically resected and histologically confirmed PCNs. Pooled sensitivity, specificity, and diagnostic odds ratios (DORs) were calculated as compound measures of diagnostic accuracy using the random-effects model. Summary of receiver operating characteristic (SROC) curves and the area under the curve (AUC) were also performed. Results: A total of 21 studies with 3723 patients were included in this meta-analysis. Of these studies, 15, 4, and 2 evaluated the Fukuoka guidelines, the AGA guidelines, and both guidelines, respectively. For AN prediction, the Fukuoka guidelines had a pooled sensitivity of 0.67 (95% confidence interval [CI] 0.64–0.70), pooled specificity of 0.64 (95% CI 0.62–0.66), and pooled DOR of 6.28 (95% CI 4.38–9.01), with an AUC of the SROC of 0.78. AGA guidelines showed a pooled sensitivity of 0.59 (95% CI 0.52–0.65), pooled specificity of 0.77 (95% CI 0.74–0.80), and pooled DOR of 5.84 (95% CI 2.60–13.15), with an AUC of 0.79 (95% CI 0.70–0.88). Conclusion: When used alone, the Fukuoka and AGA guidelines showed similar but unsatisfactory diagnostic accuracy in the risk stratification of malignant potential of PCN. Thus, we recommend that they be applied only as a broad framework in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic anatomy recognition in whole-body PET/CT images

Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process, to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards Real Time Diagnostics of Hybrid Welding Laser/GMAW

Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

36 MATERIALS SCIENCE↗

Future projection of mean and variability of the Asian Summer Monsoon and Indian Ocean Climate systems

The overall goal of this project is to assess the ability of the CMIP3/5 models to simulate the Indian-Ocean monsoon systems. The PI along with post-docs investigated research issues ranging from synoptic systems to long-term trends over the Asian monsoon region. The PI applied diagnostic tools such as moist static energy (MSE) to isolate: the moist and radiative processes responsible for extended monsoon breaks over South Asia, precursors in the ENSO-monsoon association, reasons for the drying tendency over South Asia and the possible effect on tropical Indian Ocean climate anomalies influencing certain aspects of ENSO characteristics. By diagnosing various observations and coupled model simulations, we developed working hypothesis and tested them by carrying out sensitivity experiments with both linear and nonlinear models. Possible physical and dynamical reasons for model sensitivities were deduced. On the teleconnection front, the ability of CMIP5 models in representing the monsoon-desert mechanism was examined recently. Further more, we have applied a suite of diagnostics and have performed an in depth analysis on CMIP5 integrations to isolate the possible reasons for the ENSO-monsoon linkage or lack thereof. The PI has collaborated with Dr. K.R. Sperber of PCMDI and other CLIVAR Asian-Australian monsoon panel members in understanding the ability of CMIP3/5 models in capturing monsoon and its spectrum of variability. The objective and process-based diagnostics aided in selecting models that best represent the present-day monsoon and its variability that are then employed for future projections. Two major highlights were an invitation to write a review on present understanding monsoons in a changing climate in Nature Climate Change, and identification of an east-west shift in observed monsoon rainfall (more rainfall over tropical western Pacific and drying tendency over South Asia) in the last six decades and attributing that shift to SST rise over the tropical western Pacific. On the training of post-doctoral scientists: the PI spent considerable amount of time and efforts in introducing the post-docs into climate modeling and designing the numerical experiments. With training provided and knowledge gained, post-docs worked in the project obtained long term positions elsewhere. The PI also enjoyed the experience in managing the works and educating work ethics to the younger generation. Based on the research achievements and publications, the PI gave invited talks in major international monsoon conferences/workshops, and gave lectures in various research organizations in the last six years. Finally, during the project period, the PI attended all the DOE organized PIs meeting and presented the major results. Some of the major implications of the project include: (i) Sustained observational efforts are necessary to monitor the three-dimensional moisture distribution over the Asian monsoon region that would aid in better understanding, modeling and predicting severe monsoons well in advance and (ii) process-based diagnostics lead pathways for model improvements.

54 ENVIRONMENTAL SCIENCES↗

Light output function and assembly of the time-of-flight enhanced diagnostics neutron spectrometer plastic scintillators for background reduction by double kinematic selection at EAST

The 2.5 MeV neutron spectrometer TOFED (Time-Of-Flight Enhanced Diagnostics) has been constructed to perform advanced neutron emission spectroscopy diagnosis of deuterium plasmas on EAST. The instrument has a double-ring structure which, in combination with pulse shape digitization, allows for a dual kinematic selection in the time-of-flight/recoil proton energy (tof/E{sub p}) space, thus improving the spectrometer capability to resolve fast ion signatures in the neutron spectrum, in principle up to a factor ≈100. The identification and separation of features from the energetic ions in the neutron spectrum depends on the detailed knowledge of the instrument response function, both in terms of the light output function of the scintillators and the effect of undesired multiple neutron scatterings in the instrument. This work presents the determination of the light output function of the TOFED plastic scintillator detectors and their geometrical assembly. Results from dedicated experiments with γ-ray sources and quasi-monoenergetic neutron beams are presented. Implications on the instrument capability to perform background suppression based on double kinematic selection are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing Diagnosis through AI-driven Analysis of Reflectance Confocal Microscopy

Reflectance Confocal Microscopy (RCM) is a non-invasive imaging technique used in biomedical research and clinical dermatology. It provides virtual high-resolution images of the skin and superficial tissues, reducing the need for physical biopsies. RCM employs a laser light source to illuminate the tissue, capturing the reflected light to generate detailed images of microscopic structures at various depths. Recent studies explored AI and machine learning, particularly CNNs, for analyzing RCM images. Our study proposes a segmentation strategy based on textural features to identify clinically significant regions, empowering dermatologists in effective image interpretation and boosting diagnostic confidence. This approach promises to advance dermatological diagnosis and treatment.

Yoon, Hong-Jun↗

TH-A-BRF-11: Image Intensity Non-Uniformities Between MRI Simulation and Diagnostic MRI

Purpose: MRI simulation for MRI-based radiotherapy demands that patients be setup in treatment position, which frequently involves use of alternative radiofrequency (RF) coil configurations to accommodate immobilized patients. However, alternative RF coil geometries may exacerbate image intensity non-uniformities (IINU) beyond those observed in diagnostic MRI, which may challenge image segmentation and registration accuracy as well as confound studies assessing radiotherapy response when MR simulation images are used as baselines for evaluation. The goal of this work was to determine whether differences in IINU exist between MR simulation and diagnostic MR images. Methods: ACR-MRI phantom images were acquired at 3T using a spin-echo sequence (TE/TR:20/500ms, rBW:62.5kHz, TH/skip:5/5mm). MR simulation images were obtained by wrapping two flexible phased-array RF coils around the phantom. Diagnostic MR images were obtained by placing the phantom into a commercial phased-array head coil. Pre-scan normalization was enabled in both cases. Images were transferred offline and corrected for IINU using the MNI N3 algorithm. Coefficients of variation (CV=σ/μ) were calculated for each slice. Wilcoxon matched-pairs and Mann-Whitney tests compared CV values between original and N3 images and between MR simulation and diagnostic MR images. Results: Significant differences in CV were detected between original and N3 images in both MRI simulation and diagnostic MRI groups (p=0.010, p=0.010). In addition, significant differences in CV were detected between original MR simulation and original and N3 diagnostic MR images (p=0.0256, p=0.0016). However, no significant differences in CV were detected between N3 MR simulation images and original or N3 diagnostic MR images, demonstrating the importance of correcting MR simulation images beyond pre-scan normalization prior to use in radiotherapy. Conclusions: Alternative RF coil configurations used in MRI simulation can Result in significant IINU differences compared to diagnostic MR images. The MNI N3 algorithm reduced MR simulation IINU to levels observed in diagnostic MR images. Funding provided by Advancing a Healthier Wisconsin.

60 APPLIED LIFE SCIENCES↗

Design of a Large Diffraction Grating Optical Assembly

The Advanced Radiographic Capability (ARC) is a diagnostic system in the National Ignition Facility (NIF) that will enable high-speed imaging of imploding targets in the NIF Target Chamber. NIF is a multi-billion dollar project to focus 192 laser beams onto a small target (approximately the size of a pencil eraser) to generate nuclear fusion. The complete ARC system is composed of approximately 80 modular large optical assemblies known as Line Replaceable Units (LRUs). The total estimated weight of the ARC optics alone is 16,000 lbs, with an average optic weight of 200 lbs. Key to the function and performance of ARC is an optical compressor, which uses diffraction gratings known as Grating LRUs to temporally compress a total of 8 laser beams. The resulting high-power beams are focused onto a back-lighter target to create high-energy xrays for imaging. These Grating LRUs are housed inside vacuum vessels called Compressor Vessels (Figures 1-5). There are a total of 32 Grating LRUs, 16 in each Compressor Vessel.

42 ENGINEERING↗

Consensus DOE Advanced Fuels Campaign TREAT/SATS Test Plan [Slides]

This record is comprised of summary slides of the Combined TREAT-LOC & SATS Integral LOCA Experiment Plan. The experimental program has been developed to specifically address data gaps and opportunities identified through detailed review of the existing public knowledgebase on LOCA FFRD and specific experimental development for prototypic LOCA conditions for LWR systems. The test program relies on a unique combination of in-pile and out-of-pile experimental approaches to (1) provide clear tieback to the existing integral and semi-integral LOCA experiment database using state-of-the-art facilities. More importantly, this program will systematically investigate the impacts of: (2) prototypic HBu fuel and cladding thermomechanical behaviors under postulated LWR LOCA conditions never fully investigated before. These conditions correspond with prototypic decay-energy heat up (DEH) and stored-energy heat up (SEH) conditions. Unique TREAT capability will provide first evaluation of SEH conditions on HBu fuels. The test program includes an emphasis on developing improved mechanistic understanding of key phenomena through independent experimental systems, development of a database to support fuel performance modeling tools, world leading advanced materials characterization, and the most advanced approach to in-situ diagnostics ever deployed to evaluate FFRD. The results will represent a significant leap forward in the evaluation of prototypic conditions and novel data to support modeling development and validation, as well as to inform the technical basis of LOCA-induced FFRD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring and Control of the Hybrid Laser-Gas Metal-Arc Welding Process

Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

36 MATERIALS SCIENCE↗