Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Measured Dynamic Aperture and Detuning of Nonlinear Integrable Optics

One of the most promising advantages of nonlinear integrable optics is strong amplitude dependent tune shift without degrading the dynamic aperture. The integrable optics test accelerator (IOTA) at Fermilab is constructed around nonlinear lattice elements of the elliptical type as described by Danilov and Nagaitsev. Detuning and dynamic aperture scans in IOTA were performed using a fast dipole kicker and a low emittance electron beam. The evolution of the dynamic aperture and detuning for different configurations of the integrable optics lattice are presented.

43 PARTICLE ACCELERATORS↗

EXPERIMENTS ON ELECTRON COOLING AND INTENSE SPACE-CHARGE AT IOTA

The Integrable Optics Test Accelerator at Fermilab will explore beam dynamics in a ring with intense space-charge using 2.5 MeV proton beams with an incoherent tune shift approaching -0.5. We will use this machine to explore the interplay between electron cooling, intense space-charge, and coherent instabilities. In this contribution, we describe the machine setup including the design of the electron cooler and the lattice, list specific experiments and discuss the results of numerical simulations which include the effects of electron cooling and transverse space-charge forces.

Banerjee, N.↗

Field Aging of Photovoltaic Module Packaging Materials: DuraMAT Field Module Library

To understand and develop models for silicon photovoltaic module degradation, accelerated testing is often used, however, outdoor field testing is necessary for validation. Outdoor field testing publications are often limited by the lack of a pristine, control module to compare the fielded module to. In this work, commercially available modules were purchased from seven different manufacturers for outdoor fielding then destructive characterization to investigate packaging material degradation on

14 SOLAR ENERGY↗

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

NASA Facility for the Study of Space Radiation Effects

Space particulate radiation from the Van Allen belts, solar flares, galactic cosmic, and manmade sources have energies and fluxes which are capable of producing damage in space mission payloads. NASA - Langley Research Center, Hampton, Virginia, has initiated the construction of a ground-based Space Radiation Effects Laboratory which simulates most of the space particulate energy spectrum and which can be used in a radiation research program for minimizing or eliminating deleterious radiation effects. A 600-megaelectronvolt synchrocyclotron of variable energy and electron accelerators from 1 to 10 megaelectronvolts will be included in the laboratory for accelerated testing. The plan of the proposed test areas reflects the latest advances in the state of the art as it pertains to the engineering and basic experimental requirements in flexibility, radiation background levels, shielding, and isolation. The laboratory operational plan permits three Virginia institutions of higher learning to cooperate with the Langley Research Center in carrying out radiation programs.

RADIATION EFFECT↗

Peak acceleration limiter

Device is described that limits accelerations by shutting off shaker table power very rapidly in acceleration tests. Absolute value of accelerometer signal is used to trigger electronic switch which terminates test and sounds alarm.

Chapman, C. P.↗

Long life assurance study for manned spacecraft long life hardware. Volume 4: Special long life assurance studies

Guidelines for the selection of equipment to be used for manned spacecraft in order to assure a five year maintenance-free service life were developed. A special study was conducted to determine the adequacy of the procedures used to determine the quality and effectiveness of various components. The subjects examined are: (1) temperature cycling for acceptance of electronic assemblies; (2) accelerated testing techniques; (3) electronic part screening techniques; (4) electronic part derating practices; (5) vibration life extension of printed circuit board assemblies; and (6) tolerance funnelling and test requirements.

Source record↗

Effects of simulated space environment on Skylab parasol material

A material consisting of ripstop nylon bonded to the Mylar side of aluminized Mylar film was used to construct the first Skylab parasol. The mechanical properties of elongation and tensile strength and the radiative properties of solar absorptance and thermal emittance were measured before and after exposure to simulated solar radiation at intensities of 1.0 and 3.5 solar constants for exposure times as long as 947 hours or 3316 equivalent solar hours. The accelerated testing indicated more severe degradation than was experienced in the real-time test (1 solar constant). The results predicted that this material could have given satisfactory performance throughout the planned lifetime of the Skylab workshop.

Slemp, W. S.↗

Measurement of separate electron and positron spectra in the primary cosmic rays from 5 to 50 GeV

A magnetic spectrometer and lead-plate spark chamber have been used to measure separate primary cosmic-ray electrons and positrons up to 50 GeV. Separation of these particles from the background was accomplished with a new technique combining both selective trigger and observation, in the lead-plate chamber, of bremsstrahlung photons that were created in a thin radiator placed above the spectrometer. The results of efficiency and rejection calibrations with accelerator tests and Monte Carlo calculations are presented, as well as preliminary data from a balloon-flight exposure of the apparatus.

Buffington, A.↗

Advance prototype silver ion water bactericide system

An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.

Jasionowski, W. J.↗

Electrolyte concentration changes during operation of the nickel cadmium cell

The concentration and distribution of aqueous potassium hydroxide (KOH) electrolyte in a sealed nickel cadmium cell is considered. The reactions at both electrodes during charge and discharge involve the production or utilization of hydroxyl ion (OH) or water (H2O) which directly affects concentration. Changes in electrolyte concentration relative to the individual electrode reactions is discussed. Quantitative values are provided for the changes in concentration for 6, 12, and 20 ah cells with accepted quantities of precharge and accepted initial quantity of 31% aqueous KOH. Consideration is given to a more correct equation which includes net changes in hydroxyl concentration in addition to water. Also, expected concentrations of electrolyte in cells in the fully charged, 75% charged, 50% charged, 25% charged and discharged condition are calculated. The expected concentration changes for cells in the accelerated tests are also tabulated and compared with measured values. All calculations are made on the assumption that there are no side reactions. Various properties which depend on KOH concentration are listed. The variables include O2, H2, and Cd(OH)2 solubilities in addition to viscosity and conductivity.

Halpert, G.↗

Individual differences in susceptibility to motion sickness among six Skylab astronauts

Motion sickness was studied in Skylab crewmen. By mission-day 8 (MD 8), astronauts were virtually free of motion sickness symptoms after rotation and linear acceleration tests. None of the Skylab-II astronauts (crewmen 1-3) was motion sick aloft, but astronaut 6 of the Skylab-III crew experienced motion sickness within an hour after transition into orbit. All three astronauts (4-6) of Skylab-III experienced motion sickness in the workshop, where astronaut 6 was most susceptible and astronaut 4 least susceptible. The higher susceptibility of SL-III crewmen in the workshop, as compared with SL-II crewmen, may be attributable to the fact that they were based in the command module (CM) less than one-third as long as were SL-II astronauts. I.e., the unnatural movements permitted in the open spaces of the workshop entrained more complex interactions of unusual vestibular and visual stimuli than did those in the CM. The observed reduced liability to kinetosis relative to earth may be due to absence of the gravity stimulus to the otolith organs.

Graybiel, A.↗

Recent developments in photovoltaic energy by ERDA/NASA-LeRC

Application development activities were designed to stimulate the market for photovoltaics so that as costs are reduced there will be an increasing market demand to encourage the expansion of industrial solar array production capacity. Supporting these application development activities are tasks concerned with: (1) establishing standards and methodology for terrestrial solar cell calibration; (2) conducting standard and diagnostic measurements on solar cells and modules; and (3) conducting real time and accelerated testing of solar cell modules and materials of construction under outdoor sunlight conditions.

Deyo, J. N.↗

Study of changes in properties of solar sail materials from radiation exposure

Techniques for monitoring changes in preparation of solar sail materials resulting from space radiation simulation, stressing (e.g., thermal, mechanical) and exposure to terrestrial environments are developed. The properties of interest are: metallic coating deterioration, polymeric film deterioration, interfacial debonding and possible metallic coating diffusion into the polymeric film. Four accelerated tests were devised to simulate the possible degradation processes mentioned above. These four tests are: a thermal shock test to simulate the wide variation of temperature expected in space (260 C to -100 C), a cyclic temperature test to stimulate the 6 minute temperature cycle anticipated in space, a mechanical vibration test to simulate mechanical bonding, folding and handling, and a humidity test to simulate terrestrial environment effects. The techniques for monitoring property changes are: visual and microscopic examination, ellipsometry, surface potential difference (SPD), photoelectron emission (PEE), and water contact angles.

Smith, T.↗