Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Development and Performance of Superconducting Undulators at the Advanced Photon Source

Several years ago, an article in SRN [1] with the same title as this article summarized the decade-long development of superconducting undulators (SCUs) at the Advanced Photon Source (APS). The article presented those developments leading to the point when the first prototype, called SCU0 and intended for installation at the APS, was under fabrication. SCU0 was built in 2012, its cryogenic performance has been extensively tested, and detailed magnet measurements of the device have been conducted. After verification that SCU0 met all of the technical requirements for APS insertion devices, it was installed in the APS storage ring in January 2013, commissioned in a record short time (two weeks), and became a routinely used source of hard X-rays at the APS Sector 6 ID beamline.

Gluskin, Efim↗

Data Management at the Advanced Photon Source

Data are crucial to the scientific discoveries enabled by experiments performed at the APS. Presently the APS generates approximately 10 PB of raw experimental data per year from its sixty-six operating beamlines that house over 100 unique instruments. This data is generated as a part of over 6,000 annual experiments performed by over 5,500 facility users each year. Similar to other synchrotrons, the amount of data generated at the APS continues to quickly increase due to beamline advances, such as new measurement techniques, technological advances in detectors, high-throughput instrumentation, multi-modal instruments that can acquire several measurements in a single experiment, and advanced data processing algorithms. This trend is expected to continue in the future. The revolutionized high-energy synchrotron facility proposed in the APS-U project will increase brightness and coherence, leading to further increases in data rates. Successful management of data is of vital importance to the current and future scientific productivity of the APS.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Opportunities of Soft Materials Research at Advanced Photon Source

The storage ring of the Advanced Photon Source (APS) will be upgraded to a fourth-generation ring after more than two decades of operation. During its operation as a 7 GeV ring, scattering beamlines have been built to support soft matter research programs to take advantage of the high flux and high energy beam provided by the ring. Further, the 6 GeV multi-bend achromat storage ring installed by the APS-Upgrade (APS-U) will provide new opportunities for the scattering beamlines. In this news, activities of those APS beamlines in conjunction with the APS-U will be briefly reviewed along with some recent technical highlights of their soft matter research programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high false positive rate for Kepler planetary candidates of giant stars using asterodensity profiling

Asterodensity profiling (AP) is a relatively new technique for studying transit light curves. By comparing the mean stellar density derived from the transit light curve to that found through an independent method, AP provides information on several useful properties such as orbital eccentricity and blended light. We present an AP survey of 41 Kepler Objects of Interest (KOIs), with a single transiting candidate, for which the target star's mean stellar density has been measured using asteroseismology. The ensemble distribution of the AP measurements for the 31 dwarf stars in our sample shows excellent agreement with the spread expected if the KOIs were genuine and have realistic eccentricities. In contrast, the same test for the 10 giants in our sample reveals significant incompatibility at >4σ confidence. While extreme eccentricities could be invoked, this hypothesis requires four of the KOIs to contact their host star at periastron passage, including the recently claimed confirmation of Kepler-91b. After carefully examining several hypotheses, we conclude that the most plausible explanation is that the transiting objects orbit a different star to that measured with asteroseismology—cases we define as false-positives. Based on the AP distribution, we estimate a false-positive rate (FPR) for Kepler's giant stars with a single transiting object of FPR ≅ 70% ± 30%.

79 ASTRONOMY AND ASTROPHYSICS↗

The structure of allophycocyanin B from Synechocystis PCC 6803 reveals the structural basis for the extreme redshift of the terminal emitter in phycobilisomes

Allophycocyanin B (AP-B) is one of the two terminal emitters in phycobilisomes, the unique light-harvesting complexes of cyanobacteria and red algae. Its low excitation-energy level and the correspondingly redshifted absorption and fluorescence emission play an important role in funnelling excitation energy from the hundreds of chromophores of the extramembraneous phycobilisome to the reaction centres within the photosynthetic membrane. In the absence of crystal structures of these low-abundance terminal emitters, the molecular basis for the extreme redshift and directional energy transfer is largely unknown. Here, the crystal structure of trimeric AP-B [(ApcD/ApcB) 3 ] from Synechocystis sp. PCC 6803 at 1.75 Å resolution is reported. In the crystal lattice, eight trimers of AP-B form a porous, spherical, 48-subunit assembly of 193 Å in diameter with an internal cavity of 1.1 × 10 6 Å 3 . While the overall structure of trimeric AP-B is similar to those reported for many other phycobiliprotein trimers, the chromophore pocket of the α-subunit, ApcD, has more bulky residues that tightly pack the phycocyanobilin (PCB). Ring D of the chromophores is further stabilized by close interactions with ApcB from the adjacent monomer. The combined contributions from both subunits render the conjugated rings B, C and D of the PCB in ApcD almost perfectly coplanar. Together with mutagenesis data, it is proposed that the enhanced planarity effectively extends the conjugation system of PCB and leads to the redshifted absorption (λ max = 669 nm) and fluorescence emission (679 nm) of the ApcD chromophore in AP-B, thereby enabling highly efficient energy transfer from the phycobilisome core to the reaction centres.

Peng, Pan-Pan↗

CNN-Based Phase Fault Classification in Real and Simulated Power Systems Data

This study proposes a convolutional neural network (CNN)–based two-step phase fault detection and identification method to classify anomalies in the power grid signal. Specifically, the first step checks the fault’s existence and determines the need for the second step. Subsequently, in the case of anomalies in the power grid signal, the second step identifies the type of fault, including line-to-line, single-line-to-ground, double-line-to-ground, and triple-line. Accordingly, the CNN architecture is both designed for the classification layers and trained with simulated data. To provide maximum prediction accuracy with minimum processing time, this study investigates the combinations of various feature extraction (FE) techniques, such as fast Fourier transform (FFT), amplitude and phase (AP), auto-correlation function, power spectral density, and wavelet transform (WT). Consequently, simulated and real-world results demonstrate that the proposed two-step method outperforms conventional one-step techniques, with the best performance obtained by using the combination of AP-AP, AP-WT, FFT-AP, and FFT-WT–based FE methods.

Alaca, Ozgur↗

The Effect of Coating Composition and Geometry on Thermal Barrier Coatings Lifetime

Several factors are being investigated that affect the performance of thermal barrier coatings (TBC) for use in land-based gas turbines where coatings are mainly thermally sprayed. This study examined high velocity oxygen fuel (HVOF), air plasma-sprayed (APS), and vacuum plasma-sprayed (VPS) MCrAlYHfSi bond coatings with APS YSZ top coatings at 900–1100 °C. For superalloy 247 substrates and VPS coatings tested in 1 h cycles at 1100 °C, removing 0.6 wt %Si had no effect on average lifetime in 1 h cycles at 1100 °C, but adding 0.3%Ti had a negative effect. Rod specimens were coated with APS, HVOF, and HVOF with an outer APS layer bond coating and tested in 100 h cycles in air + 10%H 2 O at 1100 °C. With an HVOF bond coating, initial results indicate that 12.5 mm diameter rod specimens have much shorter 100 h cycle lifetimes than disk specimens. Furthermore, much longer lifetimes were obtained when the bond coating had an inner HVOF layer and outer APS layer.

36 MATERIALS SCIENCE↗

SU-E-J-103: Setup Errors Analysis by Cone-Beam CT (CBCT)-Based Imaged-Guided Intensity Modulated Radiotherapy for Esophageal Cancer

Purpose: To quantify setup errors by pretreatment kilovolt cone-beam computed tomography(KV-CBCT) scans for middle or distal esophageal carcinoma patients. Methods: Fifty-two consecutive middle or distal esophageal carcinoma patients who underwent IMRT were included this study. A planning CT scan using a big-bore CT simulator was performed in the treatment position and was used as the reference scan for image registration with CBCT. CBCT scans(On-Board Imaging v1. 5 system, Varian Medical Systems) were acquired daily during the first treatment week. A total of 260 CBCT scans was assessed with a registration clip box defined around the PTV-thorax in the reference scan based on(nine CBCTs per patient) bony anatomy using Offline Review software v10.0(Varian Medical Systems). The anterior-posterior(AP), left-right(LR), superiorinferior( SI) corrections were recorded. The systematic and random errors were calculated. The CTV-to-PTV margins in each CBCT frequency was based on the Van Herk formula (2.5Σ+0.7σ). Results: The SD of systematic error (Σ) was 2.0mm, 2.3mm, 3.8mm in the AP, LR and SI directions, respectively. The average random error (σ) was 1.6mm, 2.4mm, 4.1mm in the AP, LR and SI directions, respectively. The CTV-to-PTV safety margin was 6.1mm, 7.5mm, 12.3mm in the AP, LR and SI directions based on van Herk formula. Conclusion: Our data recommend the use of 6 mm, 8mm, and 12 mm for esophageal carcinoma patient setup in AP, LR, SI directions, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗

SU-E-P-57: Radiation Doses Assessment to Paediatric Patients for Some Digital Diagnostic Radiology Examination in Emergency Department in Qatar

Purpose: The aim of this study was to evaluate radiation doses to pediatric patients undergoing standard radiographic examinations using Direct Digital Radiography (DDR) in Paediatric emergency center of Hamad General Hospital (HGH) in state of Qatar and compared with regional and international Dose Reference Levels (DRLs). Methods: Entrance Skin Dose (ESD) was measured for 2739 patients for two common X-ray examinations namely: Chest AP/PA, Abdomen. Exposure factors such as kV, mAs and Focal to Skin Distance (FSD) were recorded for each patient. Tube Output was measured for a range of selected kV values. ESD for each individual patient was calculated using the tube output and the technical exposure factors for each examination. The ESD values were compared with the some international Dose Reference Levels (DRL) for all types of examinations. Results: The most performed procedure during the time of this study was chest PA/PA (85%). The mean ESD values obtained from AP chest, PA chest and AP abdomen ranged 91–120, 80–84 and 209 – 659 µGy per radiograph for different age’s groups respectively. Two protocols have been used for chest AP and PA using different radiological parameters, and the different of ESD values for chest PA and were 41% for 1 years old child, 57% for 5 years old for chest AP. Conclusion: The mean ESD were compared with those found in literature and were found to be comparable. The radiation dose can be reduced more for Chest AP and PA examination by optimization of each investigation and hence more studies are required for this task. The results presented will serve as a baseline data needed for deriving local reference doses for pediatric X-ray examinations in this local department and hence it can be applied in the whole Qatar.

60 APPLIED LIFE SCIENCES↗

SU-E-T-325: Dosimetric Impact Due to FlexiShield in Electronic Brachytherapy (eBx) of Breast IORT: A Phantom Study

Purpose: To evaluate dosimetric change of eBx plan due to Flexishield. Methods: To simulate a clinically difficult case (skin spacing < 1 cm and touching chest wall), prostheses breast tissue phantom overlaid Xoft spherical balloon applicator. To minimize significant metal streak artifact, megavoltage CT (MVCT) scan was acquired using helical TomoTherapy HiART. Two sets of MVCT images were taken with/without FlexiShield for 15 cases: 4 for small (3–4 cm), 4 for medium (4–5 cm) and 7 for large (5–6 cm) balloon. Total 30 MVCT scans were obtained with 50 % contrast to improve image contrast of balloon relative to breast tissue phantom. Balloon deformation was measured in anterior-posterior (AP) and lateral (LAT) dimensions in the middle of balloon. Skin spacing was also evaluated. Treatment plan was made based on each MVCT scan and two balloon surface doses (AP and LAT directions) and skin dose were compared between plans with/without FlexiShield. Results: The balloon was deformed due to pressure from both FlexiShield (skin side) and FlexiShield mini (chest wall side). Mean ± standard deviation (maximum) value was 1.5 ± 1.0 mm (3.3 mm) for AP compression and 0.4 ± 0.3 mm (1.1 mm) for LAT expansion. Balloon surface dose was increased by 1.8 ± 1.2 Gy (4.9 Gy) at AP point and decreased by 0.4 ± 0.4 Gy (1.3 Gy) at LAT point. Skin spacing was constantly reduced by 1.1 ± 0.8 mm (3 mm). Skin surface dose was increased by 1.5 ± 0.8 Gy (3.3 Gy) and its relative increase was 17.9 ± 9.3% (39.6%). Conclusion: FlexiShield deforms the balloon and reduces skin spacing, thereby resulting in higher dose in AP direction, lower dose in LAT direction, and elevated skin dose compared to the plan without FlexiShield. In the clinic, this balloon deformation and corresponding dose variation should be considered.

60 APPLIED LIFE SCIENCES↗

SU-G-206-11: The Effect of Table Height On CTDIvol and SSDE in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and calculation of the Size Specific Dose Estimate (SSDE). Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). Consequently, variations in scanner table height may affect both CTDIvol and the calculated size-corrected dose index (SSDE). This study sought to characterize these effects. Methods: An anthropomorphic phantom was imaged using an AP localizer, followed by a diagnostic scan using ATCM and our institution’s routine abdomen protocol. This was repeated at various scanner table heights, recording the scanner-reported CTDIvol for each diagnostic scan. The width of the phantom was measured from the localizer and diagnostic images using in-house software. The measured phantom width and scanner-reported CTDIvol were used to calculate SSDE. This was repeated using PA localizers followed by diagnostic scans. Results: 1) The localizer-based phantom width varied by up to 54% of the nominal phantom width between minimum and maximum table heights. 2) Changing the table height caused a variation in scanner-reported CTDIvol of a factor greater than 4.6 when using a PA localizer and almost 2 when using an AP localizer. 3) SSDE, calculated from measured phantom size and scanner-reported CTDIvol, varied by a factor of more than 2.8 when using a PA localizer and almost 1.5 when using an AP localizer. Conclusion: Our study demonstrates that off-center patient positioning affects the efficacy of ATCM, more severely when localizers are acquired in the PA rather than AP projection. Further, patient positioning errors can cause a large variation in the calculated SSDE. This hinders interpretation of SSDE for individual patients and aggregate SSDE data when evaluating CT protocols and clinical practices.

60 APPLIED LIFE SCIENCES↗

Helical allophycocyanin nanotubes absorb far-red light in a thermophilic cyanobacterium

To compete in certain low-light environments, some cyanobacteria express a paralog of the light-harvesting phycobiliprotein, allophycocyanin (AP), that strongly absorbs far-red light (FRL). Using cryo–electron microscopy and time-resolved absorption spectroscopy, we reveal the structure-function relationship of this FRL-absorbing AP complex (FRL-AP) that is expressed during acclimation to low light and that likely associates with chlorophyll a–containing photosystem I. FRL-AP assembles as helical nanotubes rather than typical toroids due to alterations of the domain geometry within each subunit. Spectroscopic characterization suggests that FRL-AP nanotubes are somewhat inefficient antenna; however, the enhanced ability to harvest FRL when visible light is severely attenuated represents a beneficial trade-off. The results expand the known diversity of light-harvesting proteins in nature and exemplify how biological plasticity is achieved by balancing resource accessibility with efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

Empowering Scientific Discovery Through Computing at the Advanced Photon Source

This paper explores the challenges and solutions for managing and processing the vast amount of data generated by the Advanced Photon Source (APS), a synchrotron light source facility producing ultra-bright x-rays for diverse scientific domains. With 68 experimental beamlines covering materials research, biology, and more, the APS serves a wide user base across academia, government, and industry. The ongoing upgrade of the APS storage ring and installation of new instruments will amplify data generation and processing demands. This paper discusses the approach to address these demands through automated data processing using standardized workflows that produce faster scientific insights. The APS Data Management System coordinates various data related tasks to manage storage, data transfer, metadata cataloging, data processing, and interfaces with tools provided by Globus. Through integration with the Argonne Leadership Computing Facility (ALCF), APS users can efficiently access high-performance computing resources. Standardized workflows have led to reduced computational burdens on scientists and greater accessibility of high performance computing resources. We demonstrate how standardization and collaboration enable scientists to rapidly convert raw data into meaningful scientific results, establishing a streamlined path from data collection to analysis and ultimately to publication.

Parraga, Hannah↗

FY23 Status Report of the Activated Materials Laboratory at the Advanced Photon Source

The Activated Materials Laboratory (AML) is a new radiological facility located at the Advanced Photon Source (APS) in Argonne National Laboratory (ANL), adjacent to the high-energy x-ray microscopy (HEXM) beamline in the long beamline building (LBB) constructed under the APS-upgrade (APS-U) project. The AML is a centralized facility to facilitate the safe conduct of experiments on activated materials at the APS. This report provides an overview of the status of the AML as a Nuclear Science User Facilities (NSUF) partner user facility in preparation for the general user access in 2024 upon the commissioning of the APS-U beamlines. Specifically, details are provided regarding the laboratory's scope, functionality, components, operational blueprint, and data management approach. The plans on augmenting the instrumentation, refining operational procedures and developing a robust data management strategy for FY24 and beyond are also discussed.

43 PARTICLE ACCELERATORS↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

A survey of the selenochemistry of major, minor and trace elements.

Average data for igneous and/or metaigneous rocks and soils from seven lunar sites are presented. There are compositional similarities between Apollo 11 and Luna 16 eastern maria, Ap 12 and 15 western maria, and between Ap 16 and L 20 highlands. Subtle differences do exist between the paired mare sites and the two highland sites and striking differences between the eastern and western maria. Chondritic normalized REE (rare earth element) patterns for igneous rocks and soils from all sites range from 7-350 generally with negative Eu anomalies. Anorthositic gabbroes to anorthosites, presumably highland material, exhibit a positive Eu anomaly. The REE patterns or Sr isotopic ratios suggest two lava flows each for the L 16 and Ap 14 sites, at least four lava flows for the Ap 11 and 12 site and about six for the Ap 15 site.

Schmitt, R. A.↗

Apollo 15 mission report. Supplement 3: Ascent propulsion system final flight evaluation

Results from the postflight analysis of the ascent propulsion system (APS) performance during the Apollo 15 mission are presented. The duty cycle for the LM-10 APS consisted of two firings, and ascent stage liftoff from the lunar surface and the terminal phase ignition (TPI) burn. An evaluation was made of APS performance for the first firing and found to be satisfactory. No propulsion data was received from the second APS burn; however, all indications were that the burn was nominal. All performance parameters were well within their LM-10 3-sigma limits. Calculated throat erosion at engine cutoff for the LM-10 APS was approximately 3 percent greater than predicted.

Griffin, W. G.↗