Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFIER DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors

Active matrix, flat-panel imagers (AMFPIs) employing a 2D matrix of a-Si addressing TFTs have become ubiquitous in many x-ray imaging applications due to their numerous advantages. However, under conditions of low exposures and/or high spatial resolution, their signal-to-noise performance is constrained by the modest system gain relative to the electronic additive noise. In this article, a strategy for overcoming this limitation through the incorporation of in-pixel amplification circuits, referred to as active pixel (AP) architectures, using polycrystalline-silicon (poly-Si) TFTs is reported. Compared to a-Si, poly-Si offers substantially higher mobilities, enabling higher TFT currents and the possibility of sophisticated AP designs based on both n- and p-channel TFTs. Three prototype indirect detection arrays employing poly-Si TFTs and a continuous a-Si photodiode structure were characterized. The prototypes consist of an array (PSI-1) that employs a pixel architecture with a single TFT, as well as two arrays (PSI-2 and PSI-3) that employ AP architectures based on three and five TFTs, respectively. While PSI-1 serves as a reference with a design similar to that of conventional AMFPI arrays, PSI-2 and PSI-3 incorporate additional in-pixel amplification circuitry. Compared to PSI-1, results of x-ray sensitivity demonstrate signal gains of {approx}10.7 and 20.9 for PSI-2 and PSI-3, respectively. These values are in reasonable agreement with design expectations, demonstrating that poly-Si AP circuits can be tailored to provide a desired level of signal gain. PSI-2 exhibits the same high levels of charge trapping as those observed for PSI-1 and other conventional arrays employing a continuous photodiode structure. For PSI-3, charge trapping was found to be significantly lower and largely independent of the bias voltage applied across the photodiode. MTF results indicate that the use of a continuous photodiode structure in PSI-1, PSI-2, and PSI-3 results in optical fill factors that are close to unity. In addition, the greater complexity of PSI-2 and PSI-3 pixel circuits, compared to that of PSI-1, has no observable effect on spatial resolution. Both PSI-2 and PSI-3 exhibit high levels of additive noise, resulting in no net improvement in the signal-to-noise performance of these early prototypes compared to conventional AMFPIs. However, faster readout rates, coupled with implementation of multiple sampling protocols allowed by the nondestructive nature of pixel readout, resulted in a significantly lower noise level of {approx}560 e (rms) for PSI-3.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Program Analyzes Spacecraft/Ground Radio Links

A versatile computer program analyzes the link-design control table necessary for designing the telecommunication subsystem of a spacecraft in orbit around the Earth or on a deep-space mission. The program helps to calculate all the important parameter values for spacecraft-to-ground telemetry links and ground-to-spacecraft command links. The program also enables the design of turn-around ranging and one-way ranging links, which are very useful for determining the positions of spacecraft and for satisfying various other operational needs. The user can specify several aspects of spacecraft telecommunication-subsystem design, including the nature of the antenna (paraboloidal reflector, patch, dipole, etc.), the power-amplifier rating, and the link data rate. The program enables the use of comparative design procedures and includes an extensive database on the capabilities, attributes, and costs of commercially available telecommunications equipment. Hence, the program can also perform cost analyses. The software includes an extensive ground-station database, so that link design can be carried out using different ground stations in a comparative process in an effort to select the best design. The output of the program is in the form of graphs as well as numbers.

Lansing, Faiza↗

Progress on diamond amplified photo-cathode

Two years ago, we obtained an emission gain of 40 from the Diamond Amplifier Cathode (DAC) in our test system. In our current systematic study of hydrogenation, the highest gain we registered in emission scanning was 178. We proved that our treatments for improving the diamond amplifiers are reproducible. Upcoming tests planned include testing DAC in a RF cavity. Already, we have designed a system for these tests using our 112 MHz superconducting cavity, wherein we will measure DAC parameters, such as the limit, if any, on emission current density, the bunch charge, and the bunch length. The diamond-amplified photocathode, that promises to support a high average current, low emittance, and a highly stable electron beam with a long lifetime, is under development for an electron source. The diamond, functioning as a secondary emitter amplifies the primary current, with a few KeV energy, that comes from the traditional cathode. Earlier, our group recorded a maximum gain of 40 in the secondary electron emission from a diamond amplifier. In this article, we detail our optimization of the hydrogenation process for a diamond amplifier that resulted in a stable emission gain of 140. We proved that these characteristics are reproducible. We now are designing a system to test the diamond amplifier cathode using an 112MHz SRF gun to measure the limits of the emission current's density, and on the bunch charge and bunch length.

43 PARTICLE ACCELERATORS↗

A G-band 160 GHz T/R Module Concept for Planetary Landing Radar

In this work, the concept of a G-band transmit/receive (T/R) module centered at 160 GHz was discussed. The design makes use of state-of-the-art G-band MMIC low noise amplifiers and power amplifiers, and a high speed SPDT InGaAs PIN diode switch. The paper reports on the designs, chip results, and the integration concept for a 160 GHz T/R module. The G-band T/R module has applications toward precision altimetry and velocimetry measurements in landing radar, such as in future planetary landers on the surface of Mars

power amplifier↗

A high-bandwidth amplitude estimation technique for dynamic mode atomic force microscopy

While often overlooked, one of the prerequisites for high-speed amplitude modulation atomic force microscopy is a high-bandwidth amplitude estimation technique. Conventional techniques, such as RMS to DC conversion and the lock-in amplifier, have proven useful, but offer limited measurement bandwidth and are not suitable for high-speed imaging. Several groups have developed techniques, but many of these are either difficult to implement or lack robustness. In this contribution, we briefly outline existing amplitude estimation methods and propose a new high-bandwidth estimation technique, inspired by techniques employed in microwave and RF circuit design, which utilizes phase cancellation to significantly improve the performance of the lock-in amplifier. We conclude with the design and implementation of a custom circuit to experimentally demonstrate the improvements and discuss its application in high-speed and multifrequency atomic force microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology

The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 Å at 293 K and 79 Å at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully-Depleted CCDs with Double-Gate MOSFETs

We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charge measurement. We have also demonstrated the non-destructive readout capability of the device. Achieving single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of a small number of samples. We have demonstrated fully-depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least six times the speed of floating gate amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detected noise levels guide radiometer design

A survey of component demands and design techniques for radiometers is presented. The design of a typical radiometer is traced from the antenna through the video and data-collection stages. Key design equations are given. An example is considered that shows how IF amplifier gain must be chosen to mask video noise. The influence of front-end losses on back-end design is studied.

Schuchardt, J. M.↗

High-efficiency solid state power amplifier

A high-efficiency solid state power amplifier (SSPA) for specific use in a spacecraft is provided. The SSPA has a mass of less than 850 g and includes two different X-band power amplifier sections, i.e., a lumped power amplifier with a single 11-W output and a distributed power amplifier with eight 2.75-W outputs. These two amplifier sections provide output power that is scalable from 11 to 15 watts without major design changes. Five different hybrid microcircuits, including high-efficiency Heterostructure Field Effect Transistor (HFET) amplifiers and Monolithic Microwave Integrated Circuit (MMIC) phase shifters have been developed for use within the SSPA. A highly efficient packaging approach enables the integration of a large number of hybrid circuits into the SSPA.

Wallis, Robert E.↗

Space Shuttle Orbiter oxygen partial pressure sensing and control system improvements

A program aimed at developing a new PPO2 oxygen sensor and a replacement amplifier for the Space Shuttle Orbiter is described. Experimental design methodologies used in the test and modeling process made it possible to enhance the effectiveness of the program and to reduce its cost. Significant cost savings are due to the increased lifetime of the basic sensor cell, the maximization of useful sensor life through an increased amplifier gain adjustment capability, the use of streamlined production processes for the manufacture of the assemblies, and the refurbishment capability of the replacement sensor.

Frampton, Robert F.↗

The HP 85192B EEFet3 GaAs FET Nonlinear Model Used in the High Efficiency Microwave Power Amplifier (HEMPA)

Most nonlinear circuit analysis programs that exist today were designed primarily for transient analysis. By incorporating more accurate models in simulation programs, accurate predictions of GaAs field effect transistors (FET) behavior can be accomplished. However, should the designer need to simulate GaAs FETs that operate at high DC-to-RF conversion efficiencies, a more sophisticated model is needed. A relevant and appropriate method is called harmonic-balance, as described by Quere et al.

Sims, William Herbert, III↗

Broadband power amplifier tube: Klystron tube 5K70SK-WBT and step tuner VA-1470S

The design concept, the fabrication, and the acceptance testing of a wide band Klystron tube and remotely controlled step tuner for channel selection are discussed. The equipment was developed for the modification of an existing 20 KW Power Amplifier System which was provided to the contractor as GFE. The replacement Klystron covers a total frequency range of 2025 to 2120 MHz and is tuneable to six (6) each channel with a band width of 22 MHz or greater per channel. A 5 MHz overlap is provided between channels. Channels are selected at the control panel located in the front of the Klystron magnet or from one of three remote control stations connected in parallel with the step tuner. Included in this final report are the results of acceptance tests conducted at the vendor's plant and of the integrated system tests.

Cox, H. R.↗

Development of a High Min-Entropy Quantum Random Number Generator Based on Amplified Spontaneous Emission

We present the theory, architecture, and performance characteristics of a quantum random number generator (QRNG) which operates in a PCI express form factor-compatible plug-and-play design. The QRNG relies on a thermal light source (in this case, amplified spontaneous emission), which exhibits photon bunching according to the Bose–Einstein (BE) statistics. We demonstrate that 98.7% of the unprocessed random bit stream min-entropy is traceable to the BE (quantum) signal. The classical component is then removed using a non-reuse shift-XOR protocol, and the final random numbers are generated at a 200 Mbps rate and shown to pass the statistical randomness test suites FIPS 140-2, Alphabit, SmallCrush, DIEHARD, and Rabbit of the TestU01 library.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Submillimeter-Wave Amplifier Module with Integrated Waveguide Transitions

To increase the usefulness of monolithic millimeter-wave integrated circuit (MMIC) components at submillimeter-wave frequencies, a chip has been designed that incorporates two integrated, radial E-plane probes with an MMIC amplifier in between, thus creating a fully integrated waveguide module. The integrated amplifier chip has been fabricated in 35-nm gate length InP high-electron-mobility-transistor (HEMT) technology. The radial probes were mated to grounded coplanar waveguide input and output lines in the internal amplifier. The total length of the internal HEMT amplifier is 550 m, while the total integrated chip length is 1,085 m. The chip thickness is 50 m with the chip width being 320 m. The internal MMIC amplifier is biased through wire-bond connections to the gates and drains of the chip. The chip has 3 stages, employing 35-nm gate length transistors in each stage. Wire bonds from the DC drain and gate pads are connected to off-chip shunt 51-pF capacitors, and additional off-chip capacitors and resistors are added to the gate and drain bias lines for low-frequency stability of the amplifier. Additionally, bond wires to the grounded coplanar waveguide pads at the RF input and output of the internal amplifier are added to ensure good ground connections to the waveguide package. The S-parameters of the module, not corrected for input or output waveguide loss, are measured at the waveguide flange edges. The amplifier module has over 10 dB of gain from 290 to 330 GHz, with a peak gain of over 14 dB at 307 GHz. The WR2.2 waveguide cutoff is again observed at 268 GHz. The module is biased at a drain current of 27 mA, a drain voltage of 1.24 V, and a gate voltage of +0.21 V. Return loss of the module is very good between 5 to 25 dB. This result illustrates the usefulness of the integrated radial probe transition, and the wide (over 10-percent) bandwidth that one can expect for amplifier modules with integrated radial probes in the submillimeter-regime (>300 GHz).

Samoska, Lorene↗

Solar power satellite microwave power transmission and reception system

The microwave power transmission and reception system of the Satellite Power System (SPS) has been intensively reviewed and assessed in a three-year concept development and evaluation program. This paper will review some concepts of SPS with particular emphasis on the design of the microwave power transmission and reception system. Technology requirements and proposals for meeting them will be discussed for various parts of the microwave system and to some degree for critical components such as power amplifiers. Specific subjects to be discussed are SPS concepts, antenna design, phase control, rectenna, and technology.

Finnell, W.↗

Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

The design and test results of a novel waveguide multimode directional coupler for a CW millimeter-wave satellite beacon source are presented. The coupler separates the second harmonic power from the fundamental output power of a traveling-wave tube amplifier. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37 to 42 GHz) and VW-band (71 to 76 GHz) satellite-to-ground signals.

Telecommunications↗

Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

This paper presents the design and test results of a CW millimeter-wave satellite beacon source, based on the second harmonic from a traveling-wave tube amplifier and utilizes a novel waveguide multimode directional coupler. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37 to 42 GHz) and V/W-band (71 to 76 GHz) satellite-to-ground signals.

Simons, Rainee N.↗

Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

This paper presents the design and test results of a CW millimeter-wave satellite beacon source, based on the second harmonic from a traveling-wave tube amplifier and utilizes a novel waveguide multimode directional coupler. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37-42 GHz) and V/W-band (71- 76 GHz) satellite-to-ground signals.

Simons, Rainee N.↗