Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACTUATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Large-Eddy Simulation of a wind turbine using a Filtered Actuator Line Model

When dealing with multirotor devices such as quadcopters or wind farms, the cost of blade-resolved large-eddy simulation (LES) becomes prohibitive. Combining LES with a family of lower-fidelity models, called actuator line models (ALMs), has grown in popularity in the past decade. ALM replaces full blade resolution with an array of actuator points or lines parameterized by aerodynamic lift/drag polar plots along the blades. Body forces computed based on these actuator points are then projected onto the LES flow mesh, mimicking the effect of rotating blades on the flow. However, the optimal projection radius and the associated LES grid size is often too restrictive for multirotor simulations. Recently, a new tip-correction-based filtered ALM (F-ALM) was proposed by Martinez-Tossas and Meneveau (2019), which allows coarser-than-optimal grids by avoiding the associated overprediction of thrust. In this work, F-ALM is implemented into a high-order, in-house LES code to simulate National Renewable Energy Laboratory Phase VI wind turbine. It is then followed by a comparison between the baseline ALM and the newly implemented F-ALM in terms of instantaneous and time-averaged flow fields and blade loads, revealing the advantages of F-ALM in preventing the overprediction of power on coarse grids. Finally, this encourages accurate and affordable simulations of multirotor devices in the future.

17 WIND ENERGY↗

Dynamic Control of Photocatalytic Proton Reduction through the Mechanical Actuation of a Hydrogel Host Matrix

This paper describes a photocatalytic hydrogen evolution system that is dynamically and reversibly responsive to the pH of the surrounding solution through actuation of a micro-hydrogel (microgel) matrix that hosts the photocatalysts (CdSe/CdS nanorods). Here, the reversible actuation occurs within 0.7 s (swelling) and 1.7 s (contraction). A ΔpH of 0.01 relative to the pK a of the tertiary amine on the microgel polymer (7.27) results in a reversible change in the average diameter of the microgel hosts by a factor of 2.5 and a change in the photocatalytic turnover frequency (TOF) by a factor of five. Kinetic isotope effect and photoluminescence quenching experiments reveal that the scavenging of the photoexcited hole by sulfite ions is the rate-limiting step and leads to the observed response of the TOF to pH through actuation of the microgel. Molecular dynamics simulations quantify a greater local concentration of sulfite hole scavengers for pH < pK a .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photo-actuators via epitaxial growth of microcrystal arrays in polymer membranes

Photomechanical crystals composed of three-dimensionally ordered and densely packed photochromes hold promise for high-performance photochemical actuators. However, bulk crystals with high structural ordering are severely limited in their flexibility, resulting in poor processibility and a tendency to fragment upon light exposure, while previous nano- or microcrystalline composites have lacked global alignment. Here we demonstrate a photon-fuelled macroscopic actuator consisting of diarylethene microcrystals in a polyethylene terephthalate host matrix. These microcrystals survive large deformations and show a high degree of three-dimensional ordering dictated by the anisotropic polyethylene terephthalate, which critically also has a similar stiffness. Overall, these ordered and compliant composites exhibit rapid response times, sustain a performance of over at least hundreds of cycles and generate work densities exceeding those of single crystals. In conclusion, our composites represent the state-of-the-art for photochemical actuators and enable properties unattainable by single crystals, such as controllable, reversible and abrupt jumping (photosalient behaviour).

36 MATERIALS SCIENCE↗

Ionic electroactive polymer actuators as active microfluidic mixers

On-chip sample processing is integral to the continued development of lab-on-a-chip devices for various applications. An active microfluidic mixer prototype is proposed using ionic electroactive polymer actuators (IEAPAs) as artificial cilia. A proof-of-concept experiment was performed in which the actuators were shown to produce localized flow pattern disruptions in the laminar flow regime. Suggestions for further engineering and optimization of a scaled-down, complete device are provided. Furthermore, the device in its current state of development necessitates further engineering, the use of IEAPAs addresses issues currently associated with the use of electromechanical actuators as active microfluidic mixers and may prove to be a useful alternative to other similar materials.

36 MATERIALS SCIENCE↗

Advanced silicone materials for soft actuator applications

Soft actuators are at the forefront of the innovation tide in medicine, manufacturing, and aerospace because they are able to mimic the behavior of biological tissue and adapt to complex, unstructured environments. Of all the materials used, silicone-based elastomers have drawn enormous attention since they offer a superb combination of mechanical flexibility, biocompatibility, thermal stability, and long-term durability. In the past few years, there has also been a rapid pace of material evolution, additive manufacturing, and biointegration that has enhanced the performance and applications of silicone-based soft actuators. However, there is no focused and timely review compiling these advances. This review seeks to address that need by critically discussing recent advancements in advanced silicone materials, exploring new fabrication methodologies, and discussing emerging applications that range from wearable devices to implantable robotics. We also present suggestions for directions and the problems which must be addressed in order to further develop the performance and potential of silicone-based soft actuators, justifying the relevance and urgency of this effort.

biocompatibility↗

On the role of oxygen in dielectric barrier discharge actuation of aerodynamic flows

Phase-locked particle image velocimetry is used to study the mechanism of induced flow in the near field of a rf dielectric barrier discharge actuator mounted in the separated flow region of a bluff body. Flow actuation is found to be asymmetric, with suction toward the buried downstream electrode when it is biased positively relative to the upstream exposed electrode. Lesser flow is seen on the reverse voltage swing, where the buried electrode should attract positive ions. This phenomenon is enhanced when oxygen is added to the flow, suggesting that oxygen negative ions, possibly O{sub 2}{sup -}, play a dominant role in plasma actuation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Force approximation for a plasma actuator operating in atmospheric air

A plasma actuator has been studied using a self-consistent multibody system of quiescent air, plasma, and dielectric. Equations governing the motion of charged and neutral species have been solved with Poisson's equation. Based on first principles analysis, a functional relationship between electrodynamic force and electrical and physical control parameters has been approximated and numerically tested for air. The magnitude of approximated force increases with the fourth power of the amplitude of rf potential. Thus, the induced fluid velocity also increases. The induced velocity shows momentum injection very close to the actuator surface. There is, however, a very small increase in the induced velocity with the forcing frequency. For the specific range of operational parameters considered, the proposed force relation may help speed up the plasma actuator design process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Force generation due to three-dimensional plasma discharge on a conical forebody using pulsed direct current actuators

Understanding the behavior of three-dimensional plasmas around a pulsed dc actuator can be useful for its efficient operation in many applications. The effect of such actuators is studied using a self-consistent multibody system of neutral oxygen species and its plasma. The equations governing the motion of charged species are solved with the drift diffusion approximation. The electrostatic potential is computed from Poisson's equation. The electric field and ionization level are the highest close to the junction of electrodes and dielectric. The plasma body force thus generated also follows a similar characteristic. Results also show some dc corona instabilities. The temporal average of such force shows mostly acceleration from anode to cathode above the actuator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An experimental study of a plasma actuator in absence of free airflow: Ionic wind velocity profile

In this study, we are interested in the direct current electrical corona discharge created between two wire electrodes. The experimental results are related to some electroaerodynamic actuators based on the direct current corona discharge at the surface of a dielectric material. Several geometrical forms are selected for the dielectric surface, such as a plate, a cylinder, and a NACA 0015 aircraft wing. The current density-electric field characteristics are presented for different cases in order to determine the discharge regimes. The corona discharge produces nonthermal plasma, so it is called plasma discharge. Plasma discharge creates a tangential ionic wind above the surface at the vicinity of the wall. The ionic wind induced by the corona discharge is measured in absence of free external airflow. The ionic wind velocity profiles and the maximum induced tangential force are given for different surface forms, so it is possible to compare the actuators effect based on the span of the ionic wind velocity and thrust values. The higher ionic wind velocity is obtained with the NACA profile, which shows the effectiveness of this actuator for the airflow control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Seesaw actuation of atomic force microscope probes for improved imaging bandwidth and displacement range

The authors describe a method of actuation for atomic force microscope (AFM) probes to improve imaging speed and displacement range simultaneously. Unlike conventional piezoelectric tube actuation, the proposed method involves a lever and fulcrum ''seesaw'' like actuation mechanism that uses a small, fast piezoelectric transducer. The lever arm of the seesaw mechanism increases the apparent displacement range by an adjustable gain factor, overcoming the standard tradeoff between imaging speed and displacement range. Experimental characterization of a cantilever holder implementing the method is provided together with comparative line scans obtained with contact mode imaging. An imaging bandwidth of 30 kHz in air with the current setup was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airflow influence on the discharge performance of dielectric barrier discharge plasma actuators

In the present work, the effect of the airflow on the performance of dielectric barrier discharge plasma-actuators is investigated experimentally. In order to analyze the actuator's performance, luminosity measurements have been carried out simultaneously with the recording of the relevant electrical parameters. A performance drop of about 10% is observed for the entire measured parameter range at a flow speed of M = 0.145 (U{sub {infinity}}=50 m/s). This insight is of particular importance, since the plasma-actuator control authority is already significantly reduced at this modest speed level. The results at higher Mach numbers (0.4<M<0.8) reveal an even more pronounced reduction of about 30%. From the combined analysis, the conclusion is drawn that the decreasing electrical performance P{sub A} correlates closely with the decreasing luminosity peak intensity G-caret for increasing airflow velocities. Two non-dimensional scaling numbers are proposed to characterize and quantify the airflow influence. It is demonstrated that these numbers span a universal performance drop diagram for the entire range of investigated operating parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficiency of plasma actuator ionization in shock wave modification in a rarefied supersonic flow over a flat plate

This paper describes experimental and numerical investigations focused on the shock wave modification, induced by a dc glow discharge, of a Mach 2 flow under rarefied regime. The model under investigation is a flat plate equipped with a plasma actuator composed of two electrodes. The glow discharge is generated by applying a negative potential to the upstream electrode, enabling the creation of a weakly ionized plasma. The natural flow (i.e. without the plasma) exhibits a thick laminar boundary layer and a shock wave with a hyperbolic shape. Images of the flow obtained with an ICCD camera revealed that the plasma discharge induces an increase in the shock wave angle. Thermal effects (volumetric, and at the surface) and plasma effects (ionization, and thermal non-equilibrium) are the most relevant processes explaining the observed modifications. The effect induced by the heating of the flat plate surface is studied experimentally by replacing the upstream electrode by a heating element, and numerically by modifying the thermal boundary condition of the model surface. The results show that for a similar temperature distribution over the plate surface, modifications induced by the heating element are lower than those produced by the plasma. This difference shows that other effects than purely thermal effects are involved with the plasma actuator. Measurements of the electron density with a Langmuir probe highlight the fact that the ionization degree plays an important role into the modification of the flow. The gas properties, especially the isentropic exponent, are indeed modified by the plasma above the actuator and upstream the flat plate. This leads to a local modification of the flow conditions, inducing an increase in the shock wave angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of static and dynamic behavior of functionally graded piezoelectric actuated Poly-Si micro cantilever probe

In the present paper a novel functionally graded piezoelectric (FGP) actuated Poly-Si micro cantilever probe is proposed for atomic force microscope. The shear piezoelectric coefficient d{sub 15} has much higher value than coupling coefficients d{sub 31} and d{sub 33}, hence in the present work the micro cantilever beam actuated by d{sub 15} effect is utilized. The material properties are graded in the thickness direction of actuator by a simple power law. A three dimensional finite element analysis has been performed using COMSOL Multiphysics® (version 4.2) software. Tip deflection and free vibration analysis for the micro cantilever probe has been done. The results presented in the paper shall be useful in the design of micro cantilever probe and their subsequent utilization in atomic force microscopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flexible magnetic composites for light-controlled actuation and interfaces

The interaction between light and matter has been long explored, leading to insights based on the modulation and control of electrons and/or photons within a material. An opportunity exists in optomechanics, where the conversion of radiation into material strain and actuation is currently induced at the molecular level in liquid crystal systems, or at the microelectromechanical systems (MEMS) device scale, producing limited potential strain energy (or force) in light-driven systems. We present flexible material composites that, when illuminated, are capable of macroscale motion, through the interplay of optically absorptive elements and low Curie temperature magnetic materials. These composites can be formed into films, sponges, monoliths, and hydrogels, and can be actuated with light at desired locations. Finally, light-actuated elastomeric composites for gripping and releasing, heliotactic motion, light-driven propulsion, and rotation are demonstrated as examples of the versatility of this approach.

42 ENGINEERING↗

Cavity optoelectromechanical system combining strong electrical actuation with ultrasensitive transduction

A cavity optoelectromechanical system is reported which combines the ultrasensitive transduction of cavity optomechanical systems with the electrical actuation of nanoelectromechanical systems. Ultrasensitive mechanical transduction is achieved via optomechanical coupling. Electrical gradient forces as large as 0.40 {mu}N are realized, facilitating strong actuation with ultralow dissipation. A scanning probe microscope is implemented, capable of characterizing the mechanical modes. The integration of electrical actuation into optomechanical devices is an enabling step toward the regime of quantum nonlinear dynamics and provides capabilities for quantum control of mechanical motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robotic Arm Actuated by Electroactie Polymers

Actuators are used for many planetary and space applications. To meet the NASA goal to reduce the actuators size, mass, cost and power consumption, electroactie polymers (EAP) are being developed to induce large bending and longitudinal actuation strains.

Robotics electroactive polymers hand simulation ac↗

Computation of Static Shapes and Voltages for Micromachined Deformable Mirrors with Nonlinear Electostatic Actuators

In modeling micromachined deformable mirrors with electrostatic actuators whose gap spacings are of the same order of magnitude as that of the surface deformations, it is neccessary to use nonlinear models for the actuators. In this paper, we consider micromachined deformable mirrors modeled by a membrane or plate equation with nonlinear electrostatic actuator characteristics.

deformations optical systems adaptive optical syst↗

Detailed Design of a Magnetically-Geared Actuator for Use in Extremely Cold Lunar Environments

A magnetically-geared actuator is being developed for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. This paper describes the detailed design of this actuator, including the impactful requirements, thermal analysis, bearing loads, electromagnetic analysis and the impact of tolerance stack up, and structural analysis.

space mechanisms↗