Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

From amorphous to nanocrystalline: the effect of nanograins in amorphous matrix on the thermal conductivity of hot-wire chemical-vapor deposited silicon films

Here, we have measured the thermal conductivity of amorphous and nanocrystalline silicon films with varying crystalline content from 85K to room temperature. The films were prepared by the hot-wire chemical-vapor deposition, where the crystalline volume fraction is determined by the hydrogen (H2) dilution ratio to the processing silane gas (SiH4), R=H2/SiH4. We varied R from 1 to 10, where the films transform from amorphous for R < 3 to mostly nanocrystalline for larger R. Structural analyses show that the nanograins, averaging from 2 to 9nm in sizes with increasing R, are dispersed in the amorphous matrix. The crystalline volume fraction increases from 0 to 65% as R increases from 1 to 10. The thermal conductivities of the two amorphous silicon films are similar and consistent with the most previous reports with thicknesses no larger than a few um deposited by a variety of techniques. The thermal conductivities of the three nanocrystalline silicon films are also similar, but are about 50-70% higher than those of their amorphous counterparts. The heat conduction in nanocrystalline silicon films can be understood as the combined contribution in both amorphous and nanocrystalline phases, where increased conduction through improved nanocrystalline percolation path outweighs increased interface scattering between silicon nanocrystals and the amorphous matrix.

36 MATERIALS SCIENCE↗

Prediction of Performance Variation Caused by Manufacturing Tolerances and Defects in Gas Diffusion Electrodes of Phosphoric Acid (PA)–Doped Polybenzimidazole (PBI)-Based High-Temperature Proton Exchange Membrane Fuel Cells

The automated process of coating catalyst layers on gas diffusion electrodes (GDEs) for high-temperature proton exchange membrane fuel cells results inherently into a number of defects. These defects consist of agglomerates in which the platinum sites cannot be accessed by phosphoric acid and which are the consequence of an inconsistent coating, uncoated regions, scratches, knots, blemishes, folds, or attached fine particles—all ranging from μm to mm size. These electrochemically inactive spots cause a reduction of the effective catalyst area per unit volume (cm2/cm3) and determine a drop in fuel cell performance. A computational fluid dynamics (CFD) model is presented that predicts performance variation caused by manufacturing tolerances and defects of the GDE and which enables the creation of a six-sigma product specification for Advent phosphoric acid (PA)-doped polybenzimidazole (PBI)-based membrane electrode assemblies (MEAs). The model was used to predict the total volume of defects that would cause a 10% drop in performance. It was found that a 10% performance drop at the nominal operating regime would be caused by uniformly distributed defects totaling 39% of the catalyst layer volume (~0.5 defects/μm2). The study provides an upper bound for the estimation of the impact of the defect location on performance drop. It was found that the impact on the local current density is higher when the defect is located closer to the interface with the membrane. The local current density decays less than 2% in the presence of an isolated defect, regardless of its location along the active area of the catalyst layer.

Gurau, Vladimir (ORCID:0000000327429061)↗

Piezoelectrically actuated miniature peristaltic pump.

There is a range of NASA experiments, instruments and applications where miniature pumps are needed. To address such needs, a piezoelectrically actuated miniature pump is being developed. This pump employs a novel volume displacing mechanism using flexural traveling waves that acts peristaltically and eliminates the need for valves or physically moving parts. This pump is being developed for planetary instruments and space applications. Finite element model was developed using ANSYS for the purpose of prediction of the resonance frequency of the vibrating mode for the piezo-pump driving stator. The model allows determining simultaneously the mode shapes that are associated with the various resonance frequencies. This capability is essential for designing the pump size and geometry. To predict and optimize the pump efficiency that is determined by the volume of pumping chambers the model was modified to perform harmonic analysis.

Chang, Zensheu↗

Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment

A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.

Sullenberger, Ryan M.↗

Cost and price estimate of Brayton and Stirling engines in selected production volumes

The methods used to determine the production costs and required selling price of Brayton and Stirling engines modified for use in solar power conversion units are presented. Each engine part, component and assembly was examined and evaluated to determine the costs of its material and the method of manufacture based on specific annual production volumes. Cost estimates are presented for both the Stirling and Brayton engines in annual production volumes of 1,000, 25,000, 100,000 and 400,000. At annual production volumes above 50,000 units, the costs of both engines are similar, although the Stirling engine costs are somewhat lower. It is concluded that modifications to both the Brayton and Stirling engine designs could reduce the estimated costs.

Fortgang, H. R.↗

Technical challenges of sparing infrahyoid swallowing organs at risk in oropharynx squamous cell cancer treated with IMRT

This study reports clinical performance in the sparing of infrahyoid swallowing organs at risk (SWOARs) in oropharynx cancer intensity-modulated radiation therapy (IMRT) plans. Rates of meeting dose-volume planning goals are reported and compared with geometry-based estimates of what is achievable. This study also develops 3 measures of target-SWOAR geometry and tests their usefulness in providing geometry-based dose-volume planning goals. A total of 50 oropharynx cancer IMRT plans were reviewed. Success rates in meeting institutional dose-volume goals were determined for the glottic larynx (G), postcricoid pharynx (P), and esophagus (E). The following 3 measures of target-SWOAR geometry were investigated as methods of identifying geometry-based planning goals: presence of gross disease in neck levels 3 to 4, target-SWOAR overlap, and a 3-dimensional (3D) measure of target-SWOAR geometry. Locally advanced disease was predominant in this patient population with target volumes overlapping SWOARs in 68% to 98% of cases. Clinical rates of success in meeting dose-volume goals varied by SWOAR (16% to 82%) but compared well with estimated potentially achievable rates in most cases (14% average difference between clinical and potential). Cases grouped by the presence of levels 3 to 4 neck nodes or target-SWOAR overlap did not have significantly different SWOAR doses. Cases grouped using a 3D measure of target-SWOAR geometry differed significantly, providing useful geometry-based planning goals (e.g., mean Glottis dose <45 Gy was achieved 19%, 44%, or 81% of the time in each of 3 groups). This study describes the technical challenge of sparing SWOARs and investigates several potential methods for grouping cases to assist with treatment plan evaluation. Quantifying the 3-D relationship between the targets and SWOARs is a promising way of approaching this complex problem. Data presented in this paper may be useful to evaluate treatment plans using objective geometry-based goals.

61 RADIATION PROTECTION AND DOSIMETRY↗

Changes in soil pore structure generated by the root systems of maize , sorghum and switchgrass affect in situ N 2 O emissions and bacterial denitrification

Due to the heterogeneous nature of soil pore structure, processes such as nitrification and denitrification can occur simultaneously at microscopic levels, making prediction of small-scale nitrous oxide (N 2 O) emissions in the field notoriously difficult. We assessed N 2 O+N 2 emissions from soils under maize (Zea mays L.), switchgrass (Panicum virgatum L.), and energy sorghum (Sorghum bicolor L.), three potential bioenergy crops in order to identify the importance of different N 2 O sources to microsite production, and relate N 2 O source differences to crop-associated differences in pore structure formation. The combination of isotopic surveys of N 2 O in the field during one growing season and X-ray computed tomography (CT) enabled us to link results from isotopic mappings to soil structural properties. Further, our methodology allowed us to evaluate the potential for in situ N 2 O suppression by biological nitrification inhibition (BNI) in energy sorghum. Our results demonstrated that the fraction of N 2 O originating from bacterial denitrification and reduction of N 2 O to N 2 is largely determined by the volume of particulate organic matter occluded within the soil matrix and the anaerobic soil volume. Bacterial denitrification was greater in switchgrass than in the annual crops, related to changes in pore structure caused by the coarse root system. This led to high N-loses through N 2 emissions in the switchgrass system throughout the season a novel finding given the lack of data in the literature for total denitrification. Isotopic mapping indicated no differences in N 2 O-fluxes or their source processes between maize and energy sorghum that could be associated with the release of BNI by the investigated sorghum variety. The results of this research show how differences in soil pore structures among cropping systems can determine both N 2 O production via denitrification and total denitrification N losses in situ.

59 BASIC BIOLOGICAL SCIENCES↗

18F-fluorodeoxyglucose Positron Emisson Tomography/Computed Tomography Guided Conformal Brachytherapy for Cervical Cancer

Purpose: To evaluate the feasibility of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT)-guided conformal brachytherapy treatment planning in patients with cervical cancer. Methods and Materials: Pretreatment FDG-PET/CT was performed for 12 patients with cervical cancer. Brachytherapy simulation was performed after an external-beam radiation therapy median dose of 4140 cGy. Patients underwent FDG-PET/CT scans with placement of tandem and ovoid applicators. The gross tumor volume (GTV) was determined by adjusting the window and level to a reasonable value and outlining the edge of the enhancing area, which was done in consultation with a nuclear medicine physician. A standardized uptake value profile of the tumor margin was taken for each patient relative to the maximum uptake value of each tumor and analyzed. The plan was designed to deliver 400 cGy to point A (point A plan) or to cover the clinical target volume (CTV) (PET/CT plan). Results: The median dose that encompassed 95% of the target volume (D95) of the CTV was 323.0 cGy for the point A plan vs 399.0 cGy for the PET/CT plan (P=.001). The maximum standardized uptake values (SUV{sub max}) of the tumors were reduced by a median of 57% (range, 13%-80%). All but 1 patient presented with discernable residual uptake within the tumors. The median value of the thresholds of the tumors contoured by simple visual analysis was 41% (range, 23%-71%). Conclusions: In this study, the PET/CT plan was better than the conventional point A plan in terms of target coverage without increasing the dose to the normal tissue, making optimized 3-dimensional brachytherapy treatment planning possible. In comparison with the previously reported study with PET or CT alone, we found that visual target localization was facilitated by PET fusion on indeterminate CT masses. Further studies are needed to characterize the metabolic activity detected during radiation therapy for more reliable targeting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-Scale Modeling of Swelling in Accident-Tolerant U 3 Si 2 Fuel

U 3 Si 2 is a promising candidate for use as an accident-tolerant fuel for light water reactors. A multi-scale computational approach was used to calculate swelling in pellet-form U 3 Si 2 fuel. Swelling was assumed to be equal to the volume fraction of fission gas bubbles in the fuel, and the evolution of bubble volume fraction was determined from phase-field simulations. To parameterize the phase-field model, density-functional theory and molecular dynamics simulations were performed. To enable molecular dynamics simulations, a new interatomic potential for the U-Si system was developed based on the modified embedded atom method. A new phase-field model based on a grand-potential functional was also developed. The model is applicable to both intergranular and intragranular bubbles. To calculate the volume fraction of bubbles, the microstructure was decomposed into regions consisting of only intragranular or intergranular bubbles based on a truncated octahedral grain structure, and growth of the bubbles in the two regions was simulated separately. The total swelling was then calculated based on a a weighted average of bubble volume fraction in the two regions. Total swelling was of the same order of magnitude, but larger than that predicted by the existing empirical swelling model used in BISON and a rate-theory based model. Limitations of the present approach and suggestions for improvement are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour the target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose uniformity.

60 APPLIED LIFE SCIENCES↗

Incorporating DD π effects and left-hand cuts in lattice QCD studies of the T cc (3875) +

We generalize the relativistic field-theoretic three-particle finite-volume scattering formalism to describe generic DDπ systems in the charm C = 2 sector. This includes the isospin-0 channel, in which the recently discovered doubly-charmed tetraquark T cc (3875) + is expected to manifest as a pole in the DDπ → DDπ scattering amplitude. The formalism presented here can also be applied to lattice QCD settings in which the D * is bound and, in particular, remains valid below the left-hand cut in DD * scattering, thus resolving an issue in previous analyses of lattice-determined finite-volume energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time three-dimensional echocardiographic study of left ventricular function after infarct exclusion surgery for ischemic cardiomyopathy

BACKGROUND: Infarct exclusion (IE) surgery, a technique of left ventricular (LV) reconstruction for dyskinetic or akinetic LV segments in patients with ischemic cardiomyopathy, requires accurate volume quantification to determine the impact of surgery due to complicated geometric changes. METHODS AND RESULTS: Thirty patients who underwent IE (mean age 61+/-8 years, 73% men) had epicardial real-time 3-dimensional echocardiographic (RT3DE) studies performed before and after IE. RT3DE follow-up was performed transthoracically 42+/-67 days after surgery in 22 patients. Repeated measures ANOVA was used to compare the values before and after IE surgery and at follow-up. Significant decreases in LV end-diastolic (EDVI) and end-systolic (ESVI) volume indices were apparent immediately after IE and in follow-up (EDVI 99+/-40, 67+/-26, and 71+/-31 mL/m(2), respectively; ESVI 72+/-37, 40+/-21, and 42+/-22 mL/m(2), respectively; P:<0.05). LV ejection fraction increased significantly and remained higher (0.29+/-0.11, 0.43+/-0.13, and 0.42+/-0.09, respectively, P:<0.05). Forward stroke volume in 16 patients with preoperative mitral regurgitation significantly improved after IE and in follow-up (22+/-12, 53+/-24, and 58+/-21 mL, respectively, P:<0.005). New York Heart Association functional class at an average 285+/-144 days of clinical follow-up significantly improved from 3.0+/-0.8 to 1.8+/-0.8 (P:<0.0001). Smaller end-diastolic and end-systolic volumes measured with RT3DE immediately after IE were closely related to improvement in New York Heart Association functional class at clinical follow-up (Spearman's rho=0.58 and 0.60, respectively). CONCLUSIONS: RT3DE can be used to quantitatively assess changes in LV volume and function after complicated LV reconstruction. Decreased LV volume and increased ejection fraction imply a reduction in LV wall stress after IE surgery and are predictive of symptomatic improvement.

Non-NASA Center↗

Multi-Scale Modeling of Cross-Linked Nanotube Materials

The effect of cross-linking single-walled carbon nanotubes on the Young's modulus of a nanotube-reinforced composite is modeled with a multi-scale method. The Young's modulus is predicted as a function of nanotube volume fraction and cross-link density. In this method, the constitutive properties of molecular representative volume elements are determined using molecular dynamics simulation and equivalent-continuum modeling. The Young's modulus is subsequently calculated for cross-linked nanotubes in a matrix which consists of the unreacted cross-linking agent. Two different cross-linking agents are used in this study, one that is short and rigid (Molecule A), and one that is long and flexible (Molecule B). Direct comparisons between the predicted elastic constants are made for the models in which the nanotubes are either covalently bonded or not chemically bonded to the cross-linking agent. At a nanotube volume fraction of 10%, the Young's modulus of Material A is not affected by nanotube crosslinking, while the Young's modulus of Material B is reduced by 64% when the nanotubes are cross-linked relative to the non-cross-linked material with the same matrix.

Frankland, S. J. V.↗

Planning Target Margin Calculations for Prostate Radiotherapy Based on Intrafraction and Interfraction Motion Using Four Localization Methods

Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization protocol using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the four daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new approach to study adsorption on shales and other microporous solids via the thermogravimetric analysis (TGA) technique

Measuring the adsorption of gases in microporous solids like the shales requires accurate knowledge of the solid’s skeletal volume. Helium (He) is commonly used to determine the sample’s skeletal volume based on the assumption that it does not adsorb in these porous media. The validity of such an assumption for microporous solids has been questioned in recent years, and in this study, we show that it is not applicable for the shale sample studied. We present a new method to measure the adsorption of shale-gas components in shales, which does not require the use of He to measure the solid’s skeletal volume. Since the proposed analysis method relies on the use of dynamic adsorption data, we also propose here a new zero-point correction method for the magnetic suspension balance, which is better suited for the analysis of such data. Here, we employ the new technique to the study of Argon adsorption in Marcellus Shales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic MRI Analysis of Tumor and Organ Motion During Rest and Deglutition and Margin Assessment for Radiotherapy of Head-and-Neck Cancer

Purpose: To quantify swallowing frequency and tumor and normal structure displacements during deglutition using dynamic magnetic resonance imaging (MRI) and to determine planning target volume (PTV) margins to account for resting and deglutition-induced displacements in patients with head-and-neck cancer (HNC). Methods and Materials: Twenty-two patients with HNC were imaged in the treatment position using dynamic MRI. Sagittal images were acquired. Two-dimensional displacement was analyzed using contours of normal structures and GTV drawn for one swallowing event. Deglutition-induced displacements were quantified based on position change during deglutition relative to preswallow structure location for anterior (A), posterior (P), superior (S), and inferior (I) directions. Additional long-time MRI series were obtained from a subset of 11 patients while they were resting in order to determine swallowing frequency and duration. PTV margins to account for setup error, frequency and duration of deglutition, and resting and deglutition-induced GTV motion were calculated. Results: Mean maximum resting displacements ranged from 1.5 to 3.1 mm for combined GTV subsites. Mean maximum swallowing GTV displacement for combined subsites ranged from 4.0 to 11.6 mm. Swallowing was nonperiodic, with a frequency ranging from 0 to 19 swallows over 12.8 min and mean swallow duration of 3.5 s. Based on the average swallowing characteristics in this cohort, the average PTV margins to account for setup error and tumor motion are estimated to be 4.7 mm anteriorly, 4.2 mm posteriorly, 4.7 mm inferiorly, and 6.0 mm superiorly. Conclusions: The measurable mean maximum resting displacement for the GTV indicates that tumor motion occurs even when the patient is not swallowing. Nonuniform margins should be used as a standard PTV margin that accounts for setup error and tumor motion in radiotherapy of HNC unless adaptive radiotherapy with respect to intrafraction tumor motion is performed. The PTV margin can be individualized to a single patient's swallowing characteristics or calculated as an average based on the swallowing data from the cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic properties, elasticity, and equation of state of glycerol under pressure

Herein we employed high-pressure Brillouin scattering to study the pressure dependencies of acoustic modes of glycerol up to 14 GPa at 300 K. We observed longitudinal acoustic velocities and transverse acoustic velocities for the first time from 5 to 14 GPa. The results allow the determination of a complete set of elastic properties and an accurate determination of the pressure–volume (P–V) equation of state (EOS). EOS parameters, K 0 = 14.9 ± 1.8 GPa and K' 0 = 5.6 ± 0.5, were determined from fits to the data from ambient pressure to 14 GPa. Direct volume measurements of the P–V EOS are consistent with those determined by Brillouin scattering. A deviation from a Cauchy-like relationship for elastic properties was observed, and the pressure dependencies of the photoelastic constants and relaxation times were documented from 5 to 14 GPa. These results have broad implications for glass-forming liquids, viscoelastic theory, and mode coupling theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗