Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A higher voltage Fe( II ) bipyridine complex for non-aqueous redox flow batteries

Non-aqueous redox flow batteries (RFBs) offer the possibility of higher voltage and a wider working temperature range than their aqueous counterpart. In this study, we optimize the established 2.26 V Fe(bpy) 3 (BF 4 ) 2 /Ni(bpy) 3 (BF 4 ) 2 asymmetric RFB to lessen capacity fade and improve energy efficiency over 20 cycles. We also prepared a family of substituted Fe(bpyR) 3 (BF 4 ) 2 complexes (R = –CF 3 , –CO 2 Me, –Br, –H, – t Bu, –Me, –OMe, –NH 2 ) to potentially achieve a higher voltage RFB by systematically tuning the redox potential of Fe(bpyR) 3 (BF 4 ) 2 , from 0.94 V vs. Ag/AgCl for R = OMe to 1.65 V vs. Ag/AgCl for R = CF 3 (ΔV = 0.7 V). A series of electronically diverse symmetric and asymmetric RFBs were compared and contrasted to study electroactive species stability and efficiency, in which the unsubstituted Fe(bpy) 3 (BF 4 ) 2 exhibited the highest stability as a catholyte in both symmetric and asymmetric cells with voltage and coulombic efficiencies of 94.0% and 96.5%, and 90.7% and 80.7%, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Voltage and Temperature Limits of Advanced Electrolytes for Lithium-Metal Batteries

Several advanced electrolytes (mainly ether-based) have recently demonstrated excellent electrochemical performance in high energy density lithium (Li)-metal batteries. However, the safety of these ether-based electrolytes is still unknown. This work evaluates the thermal stability of these new formulations to understand their safety limits of operation in comparison to carbonate electrolytes typically used in Li-ion batteries. Electrolyte stability is assessed in conjunction with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode and Li-metal anode at ultra-high voltages (≤ 4.8 V) and temperatures (≤ 300°C) to trigger thermal runaway, where onset and extent of heat release are monitored via isothermal microcalorimetry and differential scanning calorimetry Most ether-based electrolytes show improved thermal resilience over commercial carbonate formulations when heated up to 300°C. The thermal behavior in presence of charged cathode and Li-metal suggests that the new electrolytes may be better at stabilizing active material surfaces than carbonate electrolytes. Although extreme voltages severely destabilize the ether-based formulations, prompting thermal runaway, a phosphate based localized high concentration electrolyte exhibits superior stability over commercial carbonate electrolytes at all tested temperatures (32°C, 45°C, and 60°C). Although thermal analysis during the first charge process (as adopted in this preliminary study) may be insufficient to conclude the long-term advantages of these electrolytes, a more stable electrolyte identified under extreme voltage and temperature conditions will provide valuable guidance for the safety of future electrolyte designs.

25 ENERGY STORAGE↗

Performance, Facility Pressure Effects, and Stability Characterization Tests of NASA's Hall Effect Rocket with Magnetic Shielding Thruster

NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front magnetic pole cover thruster configuration with the thruster body electrically tied to cathode, and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68% and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the discharge current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability were mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 1×10-5 Torr-Xe (for thruster flow rates of 20.5 mg/s). Power spectral density analysis of the discharge current waveforms showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant breathing mode frequency. Finally, IVB maps of the TDU-1 thruster indicated that the discharge current became more oscillatory with higher discharge current peak-to-peak and RMS values with increased facility background pressure at lower thruster mass flow rates; thruster operation at higher flow rates resulted in less change to the thruster's IVB characteristics with elevated background pressure.

Electric Propulsion↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration: Preprint

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Fluorinated Rocksalt Cathode with Ultra-high Active Li Content for Lithium-ion Batteries

The key to increasing the energy density of lithium-ion batteries is to incorporate high contents of extractable Li into the cathode. Unfortunately, this triggers formidable challenges including structural instability and irreversible chemistry under operation. Here, we report a new kind of ultra-high Li compound: Li 4+x MoO 5 F x (1≤x≤3) for cathode with an unprecedented level of electrochemically active Li (>3 Li + per formula), delivering a reversible capacity up to 438 mAh g –1 . Unlike other reported Li-rich cathodes, Li 4+x MoO 5 F x presents distinguished structure stability to immunize against irreversible behaviors. In this work, through spectroscopic and electrochemical techniques, we find an anionic redox-dominated charge compensation with negligible oxygen release and voltage decay. Our theoretical analysis reveals a “reductive effect” of high-level fluorination stabilizes the anionic redox by reducing the oxygen ions in pure-Li conditions, enabling a facile, reversible, and high Li-portion cycling.

36 MATERIALS SCIENCE↗

Promoting Atomically Dispersed MnN 4 Sites via Sulfur Doping for Oxygen Reduction: Unveiling Intrinsic Activity and Degradation in Fuel Cells

Carbon supported and nitrogen coordinated single Mn site catalysts (Mn-N-C) catalysts are the most desirable platinum group metal (PGM)-free cathode catalysts for proton exchange membrane fuel cells (PEMFCs) due to their insignificant Fenton reactions (vs. Fe), earth abundances (vs. Co) and encouraging activity and stability. However, current Mn-N-C catalysts suffer from high over-potential due to low intrinsic activity and less dense MnN 4 sites. Herein, we present sulfur-doped Mn-N-C catalyst (Mn-N-C-S) synthesized through an effective adsorption-pyrolysis process. Using electron microscopy and X-ray absorption spectroscopy (XAS) techniques, we verify the uniform dispersion of MnN 4 sites and confirm the effect of S doping on the Mn-N coordination. The Mn-N-C-S catalyst exhibits a favorable oxygen reduction reaction (ORR) activity in acidic media relative to the S-free Mn-N-C catalyst. The corresponding membrane electrode assembly (MEA) generated a remarkable performance with a peak power density of 500 mW cm -2 under a realistic H 2 /air environment. The constant voltage tests of fuel cells confirm the much-enhanced stability of the Mn-N-C-S catalyst compared to the Fe-N-C and Fe-N-C-S catalysts. The electron microscopy and Fourier transform XAS analysis provide insights into catalyst degradation associated with Mn oxidation and agglomeration. The theoretical calculation elucidates that the promoted ORR activity is mainly attributed to the spatial effect stemmed from the repulsive interaction between the ORR intermediates and adjacent S do-pants.

25 ENERGY STORAGE↗

Fluorine-Substituted Lithium Chloride Solid Electrolytes for High-Voltage All-Solid-State Lithium-Ion Batteries

Lithium ternary halides are promising solid electrolytes, owing to their high ionic conductivity and reasonably high oxidative and chemical stability. Recently, fluorine substitution in Li 3 MCl 6 has been suggested as a promising approach for further enhancing oxidation stability. Accordingly, this study outlines a material design strategy for F-substituted Li 3 MCl 6 through systematic theoretical analyses. Calculations reveal that the mixing limit of F in Li 3 MCl 6–x F x is in the range of 0.5–1.5, and the resulting Li 3 MCl 6–x F x phases can retain ionic conductivity above 1 mS/cm up to x = 1.0. Additionally, the calculations also predict that the formation of F-containing passivating phases could increase the oxidation potential for Li3MCl5F to ~6.3 V. The proposed material design strategy is validated through the synthesis of Li 3 YCl 5 F, which is confirmed to show both high ionic conductivity and enhanced oxidation stability. The design guidelines presented herein can accelerate the potential use of halide-based electrolyte chemistries in high-voltage all-solid-state batteries.

25 ENERGY STORAGE↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Heteroatom anchoring to enhance electrochemical reversibility for high-voltage P2-type oxide cathodes of sodium-ion batteries

P2-type cathode has received extensive attention due to its faster Na+ diffusion and a high theoretical capacity in sodium-ion batteries (SIBs). However, undesirable phase transformations have induced dramatic capacity decay of SIBs during the cycling process. In this study, heteroatom anchoring through Cu/Mg dual doping is introduced into P2-type Na 0.67 Ni 0.33 Mn 0.67 O 2 cathode to enhance high-voltage electrochemical reversibility and modulate interfacial Na + kinetics. Further, the as-prepared Na 0.67 Ni 0.23 Mg 0.05 Cu 0.05 Mn 0.67 O 2 exhibits an outstanding capacity retention (83.4% after 2000 cycles at 10C) and rate performance (73 mAh g -1 at 10C, accounting for 58.7% of that at 0.1 C) over the voltage range of 2.5–4.4 V. Intensive explorations further manifest that the modified mechanism of dual-ion doping strategy is attributed to the synergistic coupling effect of a substantial change in Na occupancy distribution and an increase in oxygen vacancy buffer. Thus, the optimized cathode expedites Na + diffusion and reduces detrimental phase transformation, which favors high-rate performance and long-term cycling stability. This study develops a route to rationally design high-voltage cathode materials for SIBs.

25 ENERGY STORAGE↗

Neural Networks-Based Inverter Control: Modeling and Adaptive Optimization for Smart Distribution Networks

The optimal voltage control of inverter-based resources, especially under the high penetration of solar photovoltaics, is critical to the stability of the distribution power system. However, the computational complexity as well as the coordinated operation performance of the voltage control optimization in the distribution power system limits the real-time applications. To mitigate this issue, a model-free based adaptive optimal control scheme for the smart inverter is proposed to maximize the active power generation, minimize the power loss, and maintain the bus voltages in smart distribution networks. An inverter-based optimization model for coordinated operation is first established, considering the uncertainties of renewable power generation. Subsequently, by collecting the data and control strategies, the neural networks (NNs) based algorithm is proposed to efficiently predict the best possible control strategy. The main objective of this scheme is to accurately predict candidate optimal solutions with near-negligible feasibility and optimization gaps, with the advantage of avoiding complicated iteration-based numerical algorithms. Thereafter, the co-simulation among OpenDSS, MATLAB, and Python is set up to fully take advantage of the three individual software. Experiments are conducted based on different control parameter characteristics and structures of NNs. Finally, the results reveal that an average mean squared error of 0.013 and 1 ms response time are achieved, which is lower than some state-of-the-art methods.

42 ENGINEERING↗

Modulating physicochemical interfaces enables li-rich oxides based ceramic solid-state li batteries under ambient conditions

Li-rich layered oxides exhibit promising potential applications in high-energy-density solid-state lithium metal batteries. Nevertheless, the strong oxidative oxygen species generate at high voltage, which poses great challenges to positive electrode-side interface stability. Herein, a robust in-situ polymerization gel polymer electrolyte with bifunctional additives is designed for interface modification. These additives, include lithium difluoro(oxalate) borate and LiPO 2 F 2 , regulate the Li + chemical environment in gel polymer electrolyte to enhance crosslink density without residual oligomer, which reduce gas generation and suppress contact loss, thus avoiding interfacial impedance divergence. Concurrently, the designed gel polymer electrolyte enables a wide electrochemical stability window (up to 4.7 V) and a high Li + transference number (0.82). Additionally, the additives induced F- and B-rich inorganic cathode-electrolyte interphase inhibits side reactions and oxygen/transition metal loss effectively, stabilizing the chemical interface. The as-constructed Li-rich layered oxides-based ceramic solid-state lithium metal batteries with gel polymer electrolyte interface modification exert a high discharge capacity of 276.5 mAh g -1 at 30 °C without external pressure, delivering a retention of 81.7% after 100 cycles at 25 mA g -1 during 2.0-4.7 V. This work provides a guideline for developing high-voltage solid-state lithium metal batteries via interfacial design.

Hu, Xinchao [Xiamen University (China)]↗

Local spring effect in titanium-based layered oxides

Titanium-based layered oxides (TLOs) are one of the most promising electrode material families for sodium-ion batteries (NIBs) due to their smooth charge/discharge profiles and excellent cycle performance. However, the reaction mechanism of these materials, especially the reason for the disappearance of multiple voltage plateaus, is still not clear. Herein, two representative TLOs (Na 2/3 Ni 1/3 Ti 2/3 O 2 and Na 2/3 Co 1/3 Ti 2/3 O 2 ) with the same P2 crystal structure have been studied to scrutinize those unexplained issues. In situ synchrotron high-energy X-ray diffraction revealed a solid solution reaction mechanism for both, suggesting the absence of rigid phase transitions upon electrochemical cycling. An interesting “spring effect” of the TiO 6 octahedron, i.e., the reversible vibration of the central Ti atom inside the local octahedron upon electrochemical redox, was demonstrated by advanced X-ray absorption spectroscopy and theoretical calculations. Such an effect could suppress the rigid phase transitions, and result in smooth charge/discharge profiles and enhanced cycle stability. Finally, this work not only accounts for the disappearance of multiple voltage plateaus of TLOs for NIBs, but also provides an effective local-structure viewpoint to increase the cycle stability of electrode materials for other advanced battery systems.

25 ENERGY STORAGE↗