Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage indices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

NASA's Evolutionary Xenon Thruster (NEXT) Component Verification Testing

Component testing is a critical facet of the comprehensive thruster life validation strategy devised by the NASA s Evolutionary Xenon Thruster (NEXT) program. Component testing to-date has consisted of long-duration high voltage propellant isolator and high-cycle heater life validation testing. The high voltage propellant isolator, a heritage design, will be operated under different environmental condition in the NEXT ion thruster requiring verification testing. The life test of two NEXT isolators was initiated with comparable voltage and pressure conditions with a higher temperature than measured for the NEXT prototype-model thruster. To date the NEXT isolators have accumulated 18,300 h of operation. Measurements indicate a negligible increase in leakage current over the testing duration to date. NEXT 1/2 in. heaters, whose manufacturing and control processes have heritage, were selected for verification testing based upon the change in physical dimensions resulting in a higher operating voltage as well as potential differences in thermal environment. The heater fabrication processes, developed for the International Space Station (ISS) plasma contactor hollow cathode assembly, were utilized with modification of heater dimensions to accommodate a larger cathode. Cyclic testing of five 1/22 in. diameter heaters was initiated to validate these modified fabrication processes while retaining high reliability heaters. To date two of the heaters have been cycled to 10,000 cycles and suspended to preserve hardware. Three of the heaters have been cycled to failure giving a B10 life of 12,615 cycles, approximately 6,000 more cycles than the established qualification B10 life of the ISS plasma contactor heaters.

Herman, Daniel A.↗

Stabilized Lithium, Manganese-Rich Layered Cathode Materials Enabled by Integrating Co-Doping and Nanocoating

While lithium, manganese-rich (LMR) layered oxide cathode materials offer high energy density (>900 Wh kg –1 ) and low cost, LMR is susceptible to continuous capacity and voltage decay from the oxygen migration and side reaction with aqueous electrolyte at high voltage. Herein, the integration of Na/F co-doping (CD) and AlF 3 coating on LMR is achieved without the need of complex atomic layer deposition. Akin to pristine and CD samples, CD with 1 wt % AlF 3 (CD-1.0 wt %) shows excellent electrochemical performance with the capacity and voltage retentions of 93 and 91% after 150 cycles at 0.5C, respectively, and increased ionic conductivity. Spectroscopic analysis indicates that the coating mainly influences the Co distribution, where Co is enriched on the surface, and partial diffusion of Al 3+ ions toward the bulk, leading to a slight change of transition-metal (TM) valence states at the nanometer scale and the formation of a stable Li x (CoAl)O y phase. Post-cycling analysis reveals that CD-1.0 wt % can alleviate the formation of rock-salt structure and Mn dissolution. Besides, little to no metal segregation is detected for the cycled CD-1.0 wt % sample. This finding presents the first instance to apply co-doping and AlF 3 coating as a new strategy to enhance the structural homogeneity and takes another step toward their commercial viability.

25 ENERGY STORAGE↗

Single-hole couplings in GaAs/AlGaAs double dots probed with transport and EDSR spectroscopy

Here, we report a detailed study of the tunnel barriers within a single-hole GaAs/AlGaAs double quantum dot device (DQD). For quantum information applications as well as fundamental studies, careful tuning and reliable measurements of the barriers are important requirements. In order to tune a DQD device adequately into the single-hole electric dipole spin resonance regime, one has to employ a variety of techniques to cover the extended range of tunnel couplings. In this work, we demonstrate four separate techniques, based upon charge sensing, quantum transport, time-resolved pulsing, and electron dipole spin resonance spectroscopy to determine the couplings as a function of relevant gate voltages and magnetic field. Measurements were performed under conditions of both symmetric and asymmetric tunnel couplings to the leads. Good agreement was observed between different techniques when measured under the same conditions. The results indicate that even in this relatively simple circuit, the requirement to tune multiple gates and the consequences of real potential profiles result in non-intuitive dependencies of the couplings as a function of the plunger gate voltage and the magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with various cathodes and anodes in a high power, quasi-steady magnetoplasmadynamic (MPD) are discussed. The magnitude of the current at the onset of voltage fluctuations is shown to be an increasing function of cathode area and a weaker decreasing function of anode area. Tests with a fluted cathode indicated that the fluctuations originate in the plasma adjacent to the cathode rather than at the cathode surface. Measurements of radiative output from an optical cavity aligned to examine the current-carrying portion of a two-dimensional, 56 kA magnetoplasmadynamic discharge reveal no lasing in that region, consistent with calculations of electron excitation and resonance radiation trapping. A voltage-swept double probe technique allows single-shot determination of electron temperature and electron number density in the recombining MPD exhaust flow. Current distributions within the cavity of MPD hollow cathodes for various static prefills with no injected mass flow are examined.

Jahn, R. G.↗

Time-Resolved Spectroscopy of Insulator-Metal Transitions: Exploring Low-Energy Dynamics in Strongly Correlated Systems. Final Report

Transition metal oxides (TMOs) have attracted much attention in recent years. The strong coupling between charge, spin, and orbital degrees of freedom creates novel functional properties. The research at the interplay between ferromagnetism, ferroelectricity and conductivity provides a promising way to the development of future spintronic devices. The interface characterization of multifunctional oxide heterostructures is crucial to understand deeply the magnetic response, spin injection and spin transport. In year one, we characterized optically the magnetic property with the method of magnetization-induced second-harmonic generation (MSHG), which is a sensitive technique to selectively probe the interface where the spatial inversion symmetry is broken. The interface of n-type BaTiO 3 (BTO)/La 0.67 Sr 0.33 MnO 3 (LSMO) forms a Schottky barrier and displays a good diode effect. By applying an external electric field across the sample, we observe the magnetoelectric (ME) coupling effect to modulate the interface magnetization. The voltage dependent magnetic contrast sharply vanishes at positive voltage (applied to LSMO contact) and reveals a ferromagnetic (FM)-to- antiferromagnetic (AFM) transition occurring at the interface, while the magneto-optic Kerr effect (MOKE) indicates that the bulk property is not affected. The strain mediated mechanism and ferroelectric (FE) polarization induced charge medicated mechanism are both discussed, but they do not play an important role in the observed magnetization transition. A new mechanism is proposed - the injected minority spins through strong Hund's interaction with the local magnetic moments at positive voltage weaken the double-exchange interaction of nearby Mn e g electrons, thereby reducing the ferromagnetic (FM) ordering. The dominant superexchange interaction of localized t 2g electrons finally leads to the AFM configuration. By reducing the electron carrier concentration of BTO, a positive voltage shift of the transition is observed. The oxygen richer sample with lower carrier concentration requires a higher voltage to increase the hole doping level of LSMO to induce the interfacial AFM phase. By inserting a thin (1nm) La 0.5 Ca 0.5 MnO 3 layer between BTO and LSMO, the interface magnetic response from LSMO is enhanced. In year two, a non-multiferroic heterostructure SrTiO 3 (STO)/ La 0.5 Ca 0.5 MnO 3 (LCMO)/La 0.67 Sr 0.33 MnO 3 (LSMO) was studied. In this system, the interface FM-AFM transition is observed at negative voltage. The STO layer may act as a hole-donating layer, which induces the hole transfer to LSMO making it overdoped, while the LCMO interlayer at the 0.5 hole doping level displays complicated CE type AFM phase. Thus the AFM phase is dominant at the interface and electron accumulation is required to induce the FM phase by applying a negative voltage. For oxygen rich sample, the magnetic MSHG loop reappears at high positive voltage (around +2.5 V). At high doping level (x > 0.5), LSMO exhibits A-type AFM order, consisting of AFM superexchange coupling between adjacent layers and intralayer FM double-exchange coupling. The less tensile strain of STO and LSMO due to a smaller lattice mismatch as compared to BTO would result in a weaker interlayer coupling . Thus, interfacial A-type AFM order can occur in STO/LCMO/LSMO heterostructure at high hole doping concentration. The study of ME coupling of multifunctional oxide heterostructures is definitely important to the development and performance of future spintronic devices. The results presented here regarding the interfacial magnetic transition controlled by an external electric field offer some new perspective to study the spin transport of magnetic tunnel junctions.

36 MATERIALS SCIENCE↗

Investigation of the Selectivity of Carrier Transport Layers in Wide-Bandgap Perovskite Solar Cells

Excellent contact passivation and selectivity are prerequisites to realize the full potential of high-material-quality perovskite solar cells, first to maximize the internal voltage (or quasi-Fermi-level separation) iV within the absorber, then to translate this high internal voltage into a high external voltage V. Experimental quantification of contact passivation and selectivity is, thus, key to improving device performance. Here, open-circuit measurements of iV oc and V oc , combined with surface photovoltage measurements, are used to systematically quantify the passivation—using iVoc as a metric—and the selectivity—defined as Soc=V oc /iV oc —of a range of common carrier transport layers to wide-bandgap (1.67 eV) perovskite absorbers. The resulting solar cells suffer from large voltage deficits, particularly when NiO x is used as the hole transport layer, even though it provides better passivation than its polymer-based counterparts (PTAA and PTAA/PFN). This indicates a poor selectivity of NiO x (Soc<0.81 for NiO x -based devices), whereas devices using polymer-based hole transport layers exhibit high selectivity (S oc =0.94–0.95). In agreement with recent reports, this low selectivity is attributed to the formation of an interlayer of non-perovskite material with high resistance to holes at the perovskite/NiO x interface. These measurements also imply that the selectivity of the C60-based electron transport layers is relatively good.

carrier transport layers↗

Retrofitting stoves with forced jets of primary air improves speed, emissions, and efficiency: Evidence from six types of biomass cookstoves

Incorporating jets of forced air into biomass cookstove combustion has been shown to potentially decrease harmful emissions, leading to a variety of designs in recent years. These have shown mixed success in terms of real-world performance, usability, and durability. The Jet-Flame forced draft retrofit accessory was recently developed to implement forced jets of primary air at a low cost into a wide range of types of cookstoves using a small 1.5-W fan housed in a low-cost cast iron body to be inserted beneath the fuel bed of a biomass cooking fire. This research sought to quantify the potential efficiency and emissions performance impacts of the Jet-Flame when installed in six different types of biomass cookstoves (three open or shielded fires and three rocket stoves) versus the natural draft performance of each. The effect of the operating fan voltage was also measured. A series of tests following a modified ISO 19867-1:2018 protocol were performed in the laboratory using the Aprovecho Laboratory Emissions Measurement System (LEMS) equipped with additional oxygen and temperature sensors. Results for each stove carefully tended with a single layer of sticks showed that the global average PM 2.5 reduction with the Jet-Flame was 89 % relative to the natural draft cases, with larger relative improvements seen in the most rudimentary stoves. CO was reduced by a global average of 74 %, reaching tier 4 or 5 for all stoves. Thermal efficiency was also improved by 34 % when calculated without taking into account the energy content of the remaining char (or 21 % with char), illustrating the value of burning char to provide cooking energy rather than leaving it unburned in the combustion chamber as is common in many natural draft stoves. Time to boil was also reduced by 8 %. In addition, adjusting the voltage of the jet-flame assisted in modulating firepower, improving the usability of the stove. These results indicate a strong potential for the Jet-Flame to help reduce emissions and fuel consumption in a wide range of cookstove designs at a relatively low cost or need for changes in behavior, fuel, or cooking device. The unit also provides enhanced usability in terms of ease of startup, cooking speed, low PM emissions at high power, and burning char. Additional studies are needed to measure performance in the field and under a variety of operational conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygrothermal aging effects on polyimide and acrylate-based adhesive materials in high-performance flat-flex cable assemblies

Flat-flex assemblies are widely used across a diverse range of technologies, including consumer electronics, automotive systems, aerospace and defense applications, and medical devices, due to their compact form factor and flexibility. However, environmental stressors like temperature and humidity are known to degrade performance over time, though the main mechanisms for degradation remain unknown. Here, in this work, we examined the aging behavior of copper/polyimide/adhesive laminate systems under varying temperature and humidity conditions, focusing on material degradation and its effects on mechanical and dielectric properties. Results show that peel strength and breakdown voltage decrease with exposure time, temperature, and humidity; spectroscopic characterization revealed that the adhesive, and not the polyimide, is the weak link in the material stack-up. The adhesive, identified as a butyl acrylate-acrylonitrile (BA-AN) copolymer, exhibited age-related spectral changes that correlated with exposure severity and duration. Hydrolysis at BA ester and AN nitrile groups was identified as the primary degradation mechanism, producing amides, acids, and alcohols. We developed a mechanistic model that connects kinetic parameters for BA-AN spectral band decay to peel strength and breakdown voltage, and implicates hydrolysis at the AN moiety, not BA, in performance decrements. Modeling predictions at ambient conditions indicate faster decline in peel strength than dielectric strength at early times, followed by plateauing of both properties at longer times. These findings provide critical insights into laminate aging mechanisms and highlight the importance of addressing BA-AN degradation to improve the long-term reliability of these systems in high-humidity environments.

organic↗

Transition region response of the symmetric double probe and its application in the lower ionosphere

The technique is discussed of the symmetric double-probe which readily lends itself to the in situ measurement of plasma temperature in the ionospheric D-region because it can lead to meaningful results under relatively high collision frequencies where the Langmuir probe has been observed to fail. It is shown that the modification to the original collision-free double-probe theory of Johnson and Malter for the determination of electron temperature is never greater than + or - 12%, with a value of (8 + or - 2)% nominally applicable in the case of D-region diagnostics. This technique was successfully operated on a Nike-Cajun payload flown at mid-day from White Sands, New Mexico to an apogee of 78.5 km. The associated electronics and deployed double-probe configuration are presented, and a current-voltage characteristic collected in the ascent stage at 73.7 km is briefly discussed. The values of electron temperature indicated by the sampled data are approximately 30% higher than those predicted by theory for the anticipated state of thermal equilibrium with the ambient neutrals.

Szuszczewicz, E. P.↗

All-electric gas detector

Modified optoacoustic gas detector identifies gases by measuring pressure-induced voltage charge in electric signals. Can detect water vapor, atmospheric fluorocarbons, or certain nitrous or nitric compounds that indicate presence of explosives.

Margolis, J. S.↗

Recent work on a microwave ion source

The performance of a microwave (2.45 GHz) plasma-disk ion source using a cylindrical microwave cavity is described. The operating characteristics in argon and xenon gases with 50-200 W of input power and gas flow rates from 10-80 sccm are presented. In particular, extracted beam current versus accelerating voltage, and specific energy vs. mass utilization efficiency and extracted beam current are presented. Double Langmuir probe measurements indicate that electron densities in excess of 10 to the 12th per cu cm can be readily achieved in the microwave generated plasma.

Asmussen, J.↗

Development of ambient temperature secondary lithium cells

JPL is developing ambient temperature secondary lithium cells for future spacecraft applications. Prior studies on experimental laboratory type Li-TiS2 cells yielded promising results in terms of cycle life and rate capability. To further assess the performance of this cell, 5 Ah engineering model cells were developed. Initially baseline cells were designed and fabricated. Each cell had 15 cathodes and 16 anodes and the ratio of anode to cathode capacity is 6:1. A solution of 1.5 molar LiAsF6 in 2Me-THF was used as the electrolyte. Cells were evaluated for their cycle life at C/1 and C/5 discharge rates and 100 percent depth of discharge. The cells were cycled between voltage limits 1.7 and 2.8 volts. The rate of charge in all cases is C/10. The results obtained indicate that cells can operate at C/10 to C/2 discharge rates and have an initial energy density of 70 Wh/kg. Cells delivered more than 100 cycles at C/2 discharge rate. The details of cell design, the test program, and the results obtained are described.

Subbarao, S.↗

Development of ambient temperature secondary lithium cells

JPL is developing ambient temperature secondary lithium cells for future spacecraft applications. Prior studies on experimental laboratory type Li-TiS2 cells yielded promising results in terms of cycle life and rate capability. To further assess the performance of this cell, 5 Ah engineering model cells were developed. Initially baseline cells were designed and fabricated. Each cell had 15 cathodes and 16 anodes and the ratio of anode to cathode capacity is 6:1. A solution of 1.5 molar LiAsF6 in 2Me-THF was used as the electrolyte. Cells were evaluated for their cycle life at C/1 and C/5 discharge rates and 100 percent depth of discharge. The cells were cycled between voltage limits 1.7 and 2.8 volts. The rate of charge in all cases is C/10. The results obtained indicate that cells can operate at C/10 to C/2 discharge rates and have an initial energy density of 70 Wh/kg. Cells delivered more than 100 cycles at C/2 discharge rate. The details of cell design, the test program, and the results obtained are described.

Subbarao, S.↗

Analog synthesized fast-variable linear load

A several kilowatt power level, fast-variable linear resistor was synthesized by using analog components to control the conductance of power MOSFETs. Risetimes observed have been as short as 500 ns with respect to the control signal and 1 to 2 microseconds with respect to the power source voltage. A variant configuration of this load that dissipates a constant power set by a control signal is indicated. Replacement of the MOSFETs by static induction transistors (SITs) to increase power handling, speed and radiation hardness is discussed.

Niedra, Janis M.↗

Analog synthesized fast-variable linear load

A several-kilowatt power level, fast-variable linear resistor has been synthesized by using analog components to control the conductance of power MOSFETs. Risetimes observed have been as short as 500 ns with respect to the control signal and 1 to 2 microsec with respect to the power source voltage. A variant configuration of this load that dissipates a constant power set by a control signal is indicated. Replacement of the MOSFETs by static induction transistors to increase power handling, speed, and radiation hardness is discussed.

Niedra, Janis M.↗

Observation of Single-Event Burnout During Inductive Switching

1A power MOSFET demonstrated destructive Single-Event Effect (SEE) during ion irradiation in a switching circuit. Further investigation showed that the inductive load causing a spike in the drain-to-source voltage (VDS) that exceeded the manufacturer’s rating for several nanoseconds was enough to allow SEB. These results indicate that SEB may occur in a very short window and flyback is critical for disciplined power supply design.

Menke, Rob↗

Technologies for providing secure emergency power control of high voltage direct current transmission system

Technologies for providing secure emergency power control of a high voltage direct current transmission (HVDC) system include a controller. The controller includes circuitry configured to receive status data indicative of a present physical status of a power system. The circuitry is also configured to obtain an emergency power control command triggered by a remote source. The emergency power control command is to be executed by an HVDC transmission system of the power system. Further, the circuitry is configured to determine, as a function of the status data, whether the emergency power control command is consistent with the present physical status of the power system and block, in response to a determination that the emergency power control command is not consistent with the present physical status of the power system, execution of the emergency power control command by the HVDC transmission system.

Pan, Jiuping↗

Acidity-Governed Rules in the Electrochemical Performance of Fluorinated Benzenes for High-Voltage Lithium Metal Batteries

Judicious selection of the optimal fluorobenzene (FB) as a nonsolvating cosolvent for lithium metal batteries (LMBs) is reported. For this work, we found the key correlation between FB structures and cycling stabilities of cells: increased fluorine substitution of FBs results in higher anodic stability but at the expense of reduced reductive stability, and FBs containing three or more fluorine atoms exhibit insufficient anodic stability in the electrolyte system comprised of fluoroethylene carbonate (FEC) and ethyl methyl carbonate (EMC). More importantly, FBs with higher acidity (lower pK a ) due to protons located between two adjacent fluorine atoms tend to be more susceptible to side reactions during cycling. Our results indicate that difluorobenzenes with no “acidic” proton (DFB2 and DFB4) have emerged as the optimal choice with the desired redox stability in high-voltage LMBs. Nuclear magnetic resonance and X-ray photoelectron spectroscopy confirmed these findings, providing guidance for selecting the most suitable FB variants as nonsolvating cosolvents for high-voltage LMBs.

25 ENERGY STORAGE↗