Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

First direct 7 Be electron-capture $\mathrm{Q}$-value measurement toward high-precision searches for neutrino physics beyond the Standard Model

Here, we report the first direct measurement of the nuclear electron-capture (EC) decay Q value of 7 Be → 7 Li via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable 7 Be + samples. With a measured value of Q EC = 861.963(23) keV, this result is three times more precise than any previous determination of this quantity. This improved precision and accuracy of the 7 Be EC decay Q value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond the Standard Model (BSM) neutrino physics using 7 Be-doped superconducting sensors. This experiment has extended LEBIT capabilities, using the first low-energy beam delivered by BMIS at FRIB for PTMS, as well as measuring the lightest-mass isotopes so far with LEBIT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Most negative and most positive expectation values of the spin operator

Formulas for the most positive and most negative values of the expectation of the spin operator are given and compared with single-particle values. The Nilsson model is used to evaluate these expectations and a scenario is discussed where the value is greater than one.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bootstrap-determined p values in lattice QCD

We present a general method to determine the probability that stochastic Monte Carlo data, in particular those generated in a lattice QCD calculation, would have been obtained were that data drawn from the distribution predicted by a given theoretical hypothesis. Such a probability, or p -value, is often used as an important heuristic measure of the validity of that hypothesis. The proposed method offers the benefit that it remains usable in cases where the standard Hotelling T 2 methods based on the conventional χ 2 statistic do not apply, such as for uncorrelated fits. Specifically, we analyze q 2 , defined as the correlated χ 2 statistic obtained using an arbitrary covariance matrix estimator, and show how to use the bootstrap as a data-driven method to determine the expected distribution of q 2 for a given hypothesis with minimal assumptions. This distribution can then be used to determine the p -value for a fit to the data. We also describe a bootstrap approach for quantifying the impact upon this p -value of estimating population parameters from a single ensemble of N samples. The overall method is accurate up to a 1 / N bias which we do not attempt to quantify. Published by the American Physical Society 2025

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Revised value of the eighth-order QED contribution to the anomalous magnetic moment of the electron

We have carried out a new evaluation of the eighth-order contribution to the electron g-2 using FORTRAN codes generated by an automatic code generator gencodeN. Comparison of the new result with the old one has revealed an inconsistency in the treatment of the infrared divergences in the latter. With this error corrected we now have two independent determinations of the eighth-order term. This leads to the revised value 1 159 652 182.79(7.71)x10{sup -12} of the electron g-2, where the uncertainty comes mostly from that of the best non-QED value of the fine structure constant {alpha}. The new value of {alpha} derived from the revised theory and the latest experiment is {alpha}{sup -1}=137.035 999 084(51) [0.37 ppb], which is about 4.7 ppb smaller than the previous {alpha}{sup -1}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Singular value decomposition applied to compact binary coalescence gravitational-wave signals

We investigate the application of the singular value decomposition to compact-binary, gravitational-wave data-analysis. We find that the truncated singular value decomposition reduces the number of filters required to analyze a given region of parameter space of compact-binary coalescence waveforms by an order of magnitude with high reconstruction accuracy. We also compute an analytic expression for the expected signal loss due to the singular value decomposition truncation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

p-values for model evaluation

Deciding whether a model provides a good description of data is often based on a goodness-of-fit criterion summarized by a p-value. Although there is considerable confusion concerning the meaning of p-values, leading to their misuse, they are nevertheless of practical importance in common data analysis tasks. We motivate their application using a Bayesian argumentation. We then describe commonly and less commonly known discrepancy variables and how they are used to define p-values. The distribution of these are then extracted for examples modeled on typical data analysis tasks, and comments on their usefulness for determining goodness-of-fit are given.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Efficiently enclosing the compact binary parameter space by singular-value decomposition

Gravitational-wave searches for the merger of compact binaries use matched filtering as the method of detecting signals and estimating parameters. Such searches construct a fine mesh of filters covering a signal parameter space at high density. Previously it has been shown that singular-value decomposition can reduce the effective number of filters required to search the data. Here we study how the basis provided by the singular-value decomposition changes dimension as a function of template-bank density. We will demonstrate that it is sufficient to use the basis provided by the singular-value decomposition of a low-density bank to accurately reconstruct arbitrary points within the boundaries of the template bank. Since this technique is purely numerical, it may have applications to interpolating the space of numerical relativity waveforms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Q{sub EC} Values of the Superallowed beta Emitters {sup 34}Cl and {sup 38}K{sup m}

The superallowed beta-decay Q{sub EC} values of {sup 34}Cl and {sup 38}K{sup m} have been measured with an online Penning trap to be 5491.662(47) keV and 6044.223(41) keV, respectively. The new values are more precise than the previous high-precision reaction-based values but are consistent with them and establish that there are no significant systematic differences between the two types of measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CODATA recommended values of the fundamental physical constants: 2006

This paper gives the 2006 self-consistent set of values of the basic constants and conversion factors of physics and chemistry recommended by the Committee on Data for Science and Technology (CODATA) for international use. Further, it describes in detail the adjustment of the values of the constants, including the selection of the final set of input data based on the results of least-squares analyses. The 2006 adjustment takes into account the data considered in the 2002 adjustment as well as the data that became available between 31 December 2002, the closing date of that adjustment, and 31 December 2006, the closing date of the new adjustment. The new data have led to a significant reduction in the uncertainties of many recommended values. The 2006 set replaces the previously recommended 2002 CODATA set and may also be found on the World Wide Web at physics.nist.gov/constants.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of the beam delivery system for the international linear collider.

The beam delivery system for the linear collider focuses beams to nanometer sizes at its interaction point, collimates the beam halo to provide acceptable background in the detector and has a provision for state-of-the art beam instrumentation in order to reach the ILCs physics goals. This paper describes the design details and status of the baseline configuration considered for the reference design and also lists alternatives.

43 PARTICLE ACCELERATORS↗

Analysis of the Value Proposition of High-Efficiency, Multijunction Solar Modules for Residential Rooftop Installations

Utilizing detailed bottom-up models, we analyze the potential markets for high-efficiency photovoltaic modules in the United States. We first estimate the fraction of area-constrained residential rooftops that could benefit from increasing the availability of high-efficiency systems. We then model the impact of efficiency on installed system costs in these area-constrained scenarios. Finally, we explore the value proposition of high-efficiency, fixed-tilt micro-concentrator photovoltaic modules in a series of case studies of residential customers, modeling the levelized cost of energy, payback period, and annual bill savings. We find that efficiency can provide significant savings in installed system cost and improve value to the solar system owner. The improvement in value depends on location and the size of the rooftop, as well as the ability of a given technology to collect diffuse light and achieve low module costs.

14 SOLAR ENERGY↗

Reliability Value of Fast State Estimation on Power Systems

Monitoring the state of a power system under stress is key to achieving reliable operation. State estimation and timely measurements become more important when applying and designing corrective control actions (manual and automatic) to arrest or mitigate cascading blackouts. The execution time of each process, including state estimation, should be as short as possible to allow for timely action. In this paper, we provide a methodology for estimating one of the components of value of faster and more frequent state estimation: the reliability value of state estimation to assist corrective control actions for arresting or mitigating cascading blackouts. We present a new algorithm for estimating the time between successive line trips in a cascading failure. The algorithm combines power flow calculations with characteristics of the protection system to estimate the time between successive equipment trips. Using this algorithm, we illustrate the value of fast state estimation by calculating the time remaining for automatic or manual corrective actions after state estimation is finalized.

Power system state estimation, cascading failures,↗

A Transactive Network Template for Decentralized Coordination of Electricity Provision and Value

Transactive energy systems facilitate and plan for an allocation of electricity based on distributed, value-based negotiations. They are currently extending the usage of market-based principles and transactions from wholesale electricity markets where they exist today downward into distribution systems. While many interesting transactive energy systems have been proposed, few fully decentralize price discovery and price-responsive control. Even fewer plan for extensibility that will be needed for the ultimate growth of transactive networks and for the inclusion of additional and new objectives and new flexible, responsive assets. This paper introduces a transactive network template from which an agent may be configured at its network node to negotiate for electricity with other neighboring network agents, manage a set of locally-owned supply and demand assets, and induce local power balance through price discovery. A set of base object classes defines the template and may be extended. Three important basic computational responsibilities are allocated among the base object classes—scheduling, balancing, and network coordination. These several basic classes and responsibilities may be used to represent the perspective of large and small devices and regions anywhere in the electric power grid because they are based on the self-similarity of these objects and responsibilities. Agents in a transactive network are not at all unique in these basic responsibilities. So far, these following dynamic values have been addressed by extension of the base classes: energy value, demand charges, transport losses, and impacts of distributed renewable resources. The template is designed to be further extended to address and monetize still other valuable objectives.

Transactive, Transactive network, Transactive netw↗

Assessing the system value of optimal load shifting

We analyze a competitive electricity market, where consumers exhibit optimal load shifting behavior to maximize utility and producers/suppliers maximize their profit under supply capacity constraints. The associated computationally tractable formulation can be used to inform market design or policy analysis in the context of increasing availability of the smart grid technologies that enable optimal load shifting. Through analytic and numeric assessment of the model, we assess the equilibrium value of optimal electricity load shifting, including how the value changes as more electricity consumers adopt associated technologies. For our illustrative numerical case, derived from the Current Trends scenario of the ERCOT Long Term System Assessment, the average energy arbitrage value per ERCOT customer of optimal load shifting technologies is estimated to be $3 for the 2031 scenario year. We assess the sensitivity of this result to the flexibility of load, along with its relationship to the deployment of renewables. Finally, the model presented can also be a starting point for designing system operation infrastructure that communicates with the devices that schedule loads in response to price signals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Additional Capacity Value From Synergy of Variable Renewable Energy and Energy Storage

Current capacity markets often consider capacity credits from each resource independently, irrespective of the portfolio of resources, potentially overvaluing or undervaluing the capacity contribution of variable renewable energy (VRE) and energy storage (ES) in the grid. We propose a method for calculating the standalone and integrated capacity value of an added VRE resource with existing ES resources. The difference between the integrated and standalone value is the portfolio effect. This is the additional capacity value gained by the synergy of VRE and the existing fleet. Using chronological dispatch simulations and two different reliability metrics to estimate firm capacity, we demonstrate on a small test system that the portfolio effect can be substantial.

capacity credit↗

Time dependence of energy spectra of brachytherapy sources and its impact on the half and the tenth value layers

Purpose: Several factors including radionuclide purity influence the photon energy spectra from sealed brachytherapy sources. The existence of impurities and trace elements in radioactive materials as well as the substrate and encapsulation may not only alter the spectrum at a given time but also cause change in the spectra as a function of time. The purpose of this study is to utilize a semiempirical formalism, which quantitatively incorporates this time dependence, to calculate and evaluate the shielding requirement impacts introduced by this time dependence for a {sup 103}Pd source. Methods: The formalism was used to calculate the NthVL thicknesses in lead for a {sup 103}Pd model 200 seed. Prior to 2005, the {sup 103}Pd in this source was purified to a level better than 0.006% of the total {sup 103}Pd activity, the key trace impurity consisting of {sup 65}Zn. Because {sup 65}Zn emits higher energy photons and has a much longer half-life of 244 days compared to {sup 103}Pd, its presence in {sup 103}Pd seeds led to a time dependence of the photon spectrum and other related physical quantities. This study focuses on the time dependence of the NthVL and the analysis of the corresponding shielding requirements. Results: The results indicate that the first HVL and the first TVL in lead steadily increased with time for about 200 days and then reached a plateau. The increases at plateau were more than 1000 times compared to the corresponding values on the zeroth day. The second and third TVLs in lead reached their plateaus in about 100 and 60 days, respectively, and the increases were about 19 and 2.33 times the corresponding values on the zeroth day, respectively. All the TVLs demonstrated a similar time dependence pattern, with substantial increases and eventual approach to a plateau. Conclusions: The authors conclude that the time dependence of the emitted photon spectra from brachytherapy sources can introduce substantial variations in the values of the NthVL with time if certain impurities are present. The contribution of {sup 65}Zn to the dose rate constant was less than 0.03% in the earlier {sup 103}Pd seeds, and because of the use of new processing technologies since 2005, this impurity has been essentially eliminated, as demonstrated in the measured spectra of current {sup 103}Pd model 200 seeds. This study illustrates the importance of performing photon spectroscopy of the manufactured radioactive sources as a quality assurance test for an assessment over time of both the radiation protection and the dosimetric properties.

07 ISOTOPE AND RADIATION SOURCES↗

Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer

Purpose: Novel, preclinical radiotherapy modalities are being developed at synchrotrons around the world, most notably stereotactic synchrotron radiation therapy and microbeam radiotherapy at the European Synchrotron Radiation Facility in Grenoble, France. The imaging and medical beamline (IMBL) at the Australian Synchrotron has recently become available for preclinical radiotherapy and imaging research with clinical trials, a distinct possibility in the coming years. The aim of this present study was to accurately characterize the synchrotron-generated x-ray beam for the purposes of air kerma-based absolute dosimetry. Methods: The authors used a theoretical model of the energy spectrum from the wiggler source and validated this model by comparing the transmission through copper absorbers (0.1-3.0 mm) against real measurements conducted at the beamline. The authors used a low energy free air ionization chamber (LEFAC) from the Australian Radiation Protection and Nuclear Safety Agency and a commercially available free air chamber (ADC-105) for the measurements. The dimensions of these two chambers are different from one another requiring careful consideration of correction factors. Results: Measured and calculated half value layer (HVL) and air kerma rates differed by less than 3% for the LEFAC when the ion chamber readings were corrected for electron energy loss and ion recombination. The agreement between measured and predicted air kerma rates was less satisfactory for the ADC-105 chamber, however. The LEFAC and ADC measurements produced a first half value layer of 0.405 {+-} 0.015 and 0.412 {+-} 0.016 mm Cu, respectively, compared to the theoretical prediction of 0.427 {+-} 0.012 mm Cu. The theoretical model based upon a spectrum calculator derived a mean beam energy of 61.4 keV with a first half value layer of approximately 30 mm in water. Conclusions: The authors showed in this study their ability to verify the predicted air kerma rate and x-ray attenuation curve on the IMBL using a simple experimental method, namely, HVL measurements. The HVL measurements strongly supports the x-ray beam spectrum, which in turn has a profound effect on x-ray dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-E-17A-05: Complementary Prognostic Value of CT and 18F-FDG PET Non-Small Cell Lung Cancer Tumor Heterogeneity Features Quantified Through Texture Analysis

Purpose: Previous studies have shown that CT or 18F-FDG PET intratumor heterogeneity features computed using texture analysis may have prognostic value in Non-Small Cell Lung Cancer (NSCLC), but have been mostly investigated separately. The purpose of this study was to evaluate the potential added value with respect to prognosis regarding the combination of non-enhanced CT and 18F-FDG PET heterogeneity textural features on primary NSCLC tumors. Methods: One hundred patients with non-metastatic NSCLC (stage I–III), treated with surgery and/or (chemo)radiotherapy, that underwent staging 18F-FDG PET/CT images, were retrospectively included. Morphological tumor volumes were semi-automatically delineated on non-enhanced CT using 3D SlicerTM. Metabolically active tumor volumes (MATV) were automatically delineated on PET using the Fuzzy Locally Adaptive Bayesian (FLAB) method. Intratumoral tissue density and FDG uptake heterogeneities were quantified using texture parameters calculated from co-occurrence, difference, and run-length matrices. In addition to these textural features, first order histogram-derived metrics were computed on the whole morphological CT tumor volume, as well as on sub-volumes corresponding to fine, medium or coarse textures determined through various levels of LoG-filtering. Association with survival regarding all extracted features was assessed using Cox regression for both univariate and multivariate analysis. Results: Several PET and CT heterogeneity features were prognostic factors of overall survival in the univariate analysis. CT histogram-derived kurtosis and uniformity, as well as Low Grey-level High Run Emphasis (LGHRE), and PET local entropy were independent prognostic factors. Combined with stage and MATV, they led to a powerful prognostic model (p<0.0001), with median survival of 49 vs. 12.6 months and a hazard ratio of 3.5. Conclusion: Intratumoral heterogeneity quantified through textural features extracted from both CT and FDG PET images have complementary and independent prognostic value in NSCLC.

60 APPLIED LIFE SCIENCES↗