Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient absorption spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Observations of the X-ray Nova GRO J0422+32. 1: Outburst and the decay to quiescence

We present optical photometry and spectroscopy and Burst and Transient Source Experiment (BATSE) observations of the X-ray nova GRO J0422+32, obtained during outburst and its subsequent decay to quiescence. Although the X-ray and optical properties of GRO J0422+32 are broadly similar to those of other X-ray novae, it is unique in several respects. The unusually protracted decay to quiescence of the optical light curve has been punctuated by at least two minioutbursts of approximately 4 mag. The BATSE and optical outbursts are each separated by approximately 120 days. We find that the optical luminosity of GRO J0422+32 during the primary outburst is dominated by reprocessing of E greater than 10 keV X-rays. In contrast, the optical minioutbursts are most likely generated by an intrinsically bright disk rather than X-ray reprocessing: they do not appear to have any X-ray counterparts. Extremely broad (up to 6000 km/s FWZI) absorption lines have also been observed during both primary outbursts and minioutbursts. During the second minioutburst, H-alpha and H-beta emission was observed superposed on redshifted absorption features. We find that the interoutburst light curve of GRO J0422+32 may be inconsistent with an accretion disk instability as the origin of the minioutbursts. Finally, a transient 5.1/10.2 hr modulation, which may be related to the orbital period, has been observed during roughly half of our observations. However, confirmation of the orbital period must await observations in quiescence.

Callanan, Paul J.↗

Transient resonant Auger–Meitner spectra of photoexcited thymine

In this paper, we present the first investigation of excited state dynamics by resonant Auger–Meitner spectroscopy (also known as resonant Auger spectroscopy) using the nucleobase thymine as an example. Thymine is photoexcited in the UV and probed with X-ray photon energies at and below the oxygen K-edge. After initial photoexcitation to a ππ* excited state, thymine is known to undergo internal conversion to an nπ* excited state with a strong resonance at the oxygen K-edge, red-shifted from the ground state π* resonances of thymine. We resolve and compare the Auger–Meitner electron spectra associated both with the excited state and ground state resonances, and distinguish participator and spectator decay contributions. Furthermore, we observe simultaneously with the decay of the nπ* state signatures the appearance of additional resonant Auger–Meitner contributions at photon energies between the nπ* state and the ground state resonances. We assign these contributions to population transfer from the nπ* state to a ππ* triplet state via intersystem crossing on the picosecond timescale based on simulations of the X-ray absorption spectra in the vibrationally hot triplet state. Moreover, we identify signatures from the initially excited ππ* singlet state which we have not observed in our previous study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoinduced modification of optical properties of ferroelectric PZT thin films

This study investigates ultrafast photoinduced changes in optical properties of ferroelectrics (PZT) on femtosecond to nanosecond timescales, using broadband transient reflectivity studies. Surprisingly, spectral features were observed below the bandgap, which could not be attributed to ground state bleaching, excited state absorption, and/or stimulated emission. A model based on probe energy independent changes in refractive index and extinction coefficient showed good agreement with experimental results. Three relaxation processes were phenomenologically considered for the temporal evolution. Laser-induced heating was ruled out as the cause of short timescale behavior and photorefractive effect was suggested as a potential mechanism for changes in the optical properties.

36 MATERIALS SCIENCE↗

In-situ/operando X-ray absorption spectroscopic investigation of the electrode/electrolyte interface on the molecular scale

A method for performing X-ray absorption spectroscopy (XAS) in the soft X-ray region was developed to investigate the surface-sensitive electron signal of electrode/electrolyte interfaces in common multivalent based organic solvents under in situ/operando conditions. Our approach enables us to probe the molecular-scale structure of electrode interfaces by measuring total electron yield and is suitable for redox systems exhibiting low intrinsic electrochemical current. In-situ F K-edge XAS measurements in a 0.5 M Magnesium bis(trifluoromethanesulfonimide)/2-Methyltetrahydrofuran (Mg(TFSI) 2 /2-MeTHF) electrolyte were carried out to determine the evolution of interfacial species during the electrochemical charging/discharging process. Time-dependent density-functional theory (TD-DFT) simulation indicate that the F K-edge evolution is the result of interfacial chemical environment change driven by electrochemical potential. In addition, we performed the “operando XAS” which runs the CV and collects spectra simultaneously. Furthermore, by using this method, the non-equilibrium state of condensed matter interfaces and interfacial dynamical transient process can be revealed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

Excited-State Charge Transfer in Push–Pull Platinum(II) π-Extended Porphyrins Fused with Pentacenequinone

Platinum(II) π-extended porphyrins fused with pentacenequinone and dihydropentacene have been successfully synthesized. These porphyrins were investigated using various techniques including absorption, steady-state, and time-resolved phosphorescence spectroscopy and differential pulse voltammetry. UV–vis absorption spectra of pentacenequinone-fused porphyrins (SW-Pt1 and SW-Pt2) showed unusually broad and nontypical absorption patterns. Phosphorescence spectra of SW-Pt1, SW-Pt2, and SW-Pt3 displayed similar emissions in the 704–706 nm region indicating electronic transitions of similar origin; however, the triplet lifetimes were found to be quenched in the case of both SW-Pt1 and SW-Pt2, suggesting the occurrence of excited-state events. Facile reductions were obtained for both the pentacene-quinone-fused monomer (SW-Pt2) and dimer (SW-Pt1) and were identified to be located at the pentacenequinone components. Here, the observed orbital segregations for SW-Pt2 and SW-Pt1 from DFT calculations supported the possibility of charge transfer in these push–pull systems. Interestingly, the established energy level diagram revealed that the charge transfer from the triplet excited Pt porphyrin is thermodynamically an uphill process. Systematic studies involving both femtosecond and nanosecond transient absorption techniques revealed that the singlet excited Pt porphyrins undergo an intermediate charge transfer state prior to populating the triplet state, providing a plausible explanation for phosphorescence quenching. The lifetime of the intermediate charge transfer states was found to be 25.9 and 5.68 ps, respectively, for SW-Pt1 and SW-Pt2.

Charge transfer↗

The Solar-Stellar Connection (NAG5-6124: SOHO Guest Investigator Program)

The following is a final report from the SOHO Guest Investigator program to use the SUMER far-UV spectrometer to obtain imaging spectroscopy in support of the goals of the so-called "solar-stellar connection." In particular, a major emphasis was utilization of the long-slit time-resolved maps of the solar surface in bright far-UV emission lines to deduce how particular aspects of the temporally and spatially averaged line profiles trace back to individual structural features of the magnetically disturbed outer atmosphere; to help interpret the unresolved line profiles from high quality stellar observations (say, with the Space Telescope Imaging Spectrograph). The researchers served two tours of duty in the SOHO Operations Center as SUMER planners, during which time we conducted an extensive series of observing programs. These can be divided into three general categories: surface mapping, translimb spectroscopy, and active region diagnostics. We have analyzed some of the large volumes of data to the point where we have presented them in poster papers, and in invited papers at national and international meetings. Listed below are the titles of the preliminary publications we have written, including brief abstracts to indicate the main results. (1) Chromospheric structure and Dynamics-- Observations -- The chromosphere is a highly structured dynamic 'layer' of the solar outer atmosphere. Here, not only are the effects of mechanical heating first evident (moving upward in altitude from the deep photosphere), but also the amount of nonradiative energy deposited is far greater than in the albeit much hotter overlying transition region and corona. Further, the chromosphere is by far the thickest zone of the solar atmosphere with respect to the pressure scale height. A major goal of stellar astrophysics is to understand how the chromosphere is heated and why it adopts its peculiar structure. A cursory examination of solar filtergrams and high-resolution movies demonstrates that much of the chromospheric "action" must be occurring on fine spatial scales and short times; particularly in the cell interior transient brightenings, but also in the longer-lived network fragments. That regime of investigation is far removed from what one usually associates with "synoptic" measurements. Nevertheless, synoptic observations of chromospheric indices, filtergrams, and globally-averaged profile parameters not only can provide important insight concerning the crucial role of the cycle-variable part of the solar magnetic field; but they also can forge a key link with analogous measurements of the stars, where often the phenomena can be significantly exaggerated from the solar case, but high spatial resolution reconnaissance is not even a remote possibility. In addition to discussing the synoptic aspects of chromospheric structure and dynamics, I summarized new insights into the general problem of the solar chromosphere that have been obtained recently with the SUMER far-ultraviolet spectrometer on SOHO. (2) CO and the Temperature Structure of the Solar Atmosphere -- The surface layers of the Sun provide a crucial boundary condition for many of the processes that occur in the deep interior. The stratification of the outer solar atmosphere once was thought to be well understood. However, studies of thermally sensitive molecular absorptions in the infrared revealed puzzling anomalies. Strong lines of the CO fundamental vibration-rotation bands near 5 microns showed very cool temperatures at the extreme limb, and remarkable off-limb emissions extending well into the supposedly hot chromosphere. The conflicting pictures of the photosphere/chromosphere interface, from the widely separated wavelength regimes, has raised suspicions that those "layers" of the atmosphere are much more inhomogeneous than previously suspected. One proposal is that the low chromosphere is dominated by cool gas, the "COmosphere," which is threaded by a network of persistent small-scale hot magnetic filaments and occasionally disrupted by localized acoustic disturbances. The COmosphere is capped by the merged fields of the network elements in the chromospheric "canopy." (3) Translimb Spectroscopy with SOHO/SUMER -- We have used SUMER to obtain deep exposures of the 1300-1400 A spectrum, at the extreme limb and off-limb. Previous "translimb" studies in the thermal infrared had revealed remarkable extensions of cold material (T is approximately equal to 3000 K)-traced by carbon monoxide emission lines-into the heart of the hot chromosphere. A main objective of our program was to search for corresponding far-UV signatures of the "thermally-bifurcated" low chromosphere; for example, radiatively fluoresced emissions of the CO A-X 4th-positive system (collisional excitation would be negligible in cold gas). We conducted two separate observing programs with SUMER. Both made use of the 1 inch-diameter circular aperture, translated across the limb in the minimum motor step increments of 0."375, along the central meridian in the Northern polar coronal hole. The first program executed for nine hours beginning 19UT 25 Oct 1996. The full wavelength range was 1340-1400 A. It was recorded in two overlapping segments, placing key regions of the spectrum alternately on the KBr and bare parts of the detector, to help isolate 2nd-order features. Each segment was integrated for 500 s, and 32 pairs were obtained to span a 12" swath centered on the optical limb. The second program was conducted 00-09UT 01 Dec 1996. It consisted of a single wavelength setting (1300-1340 A) with exposure time 500 s, but twice the spatial coverage of the earlier series: 64 steps, for a total displacement of 24". The strong chromospheric resonance lines of atomic oxygen (1302-1305 A) and ionized carbon (1334-1335 A) were observed on the bare part of the MCP camera.

Ayres, Thomas R.↗

Single-shot X-ray absorption spectroscopy at X-ray free electron lasers

X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method for studying electronic and structural properties of matter. At first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of X-ray Free Electron Lasers (XFEL) sources seem to require accumulation over many shots to achieve high data quality. To date the best approach to implementing XAS at XFEL facilities has been using monochromators to scan the photon energy across the desired spectral range. While this is possible for easily reproducible samples such as liquids, it is incompatible with many important systems. Here, we demonstrate collection of single-shot XAS spectra over 10s of eV using an XFEL source, with error bars of only a few percent. We additionally show how to extend this technique over wider spectral ranges towards Extended X-ray Absorption Fine Structure measurements, by concatenating a few tens of single-shot measurements. Our results pave the way for future XAS studies at XFELs, in particular those in the femtosecond regime. This advance is envisioned to be especially important for many transient processes that can only be initiated at lower repetition rates, for difficult to reproduce excitation conditions, or for rare samples, such as those encountered in high-energy density physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-Energy Study of Gamma-Ray Bursts Having Spectral Line Features

Gamma-ray bursts (GRBs) are energetic, short-duration emissions of gamma-rays. The Burst and Transient Source Experiment (BATSE) that was onboard NASA s Compton Gamma-Ray Observatory has done much to advance our understanding of GRBs. Perhaps foremost is to establish that GRBs originate from astronomical sources that exist well beyond our galaxy. Another area in which BATSE has been instrumental is to provide high-resolution data that can be used in spectral studies. Before BATSE, there were many reports of GRB spectra containing what appeared to be spectral absorption lines, whereas Briggs, after an extensive computer search of 117 bright BATSE GRBs, reported finding only one case that might be an absorption line and ten cases that might be emission lines. None of the eleven BATSE cases were definitively identified as spectral lines, and Briggs indicated reasons as to why the pre-BATSE reports should not be taken as conclusive. It remains an open question as to what these spectral-like features are, or if they are even real. The purpose of this work is, for the subset of the eleven BATSE GRBs for which low-energy data are available from two BATSE's Spectroscopy Detectors (SDs), to include these data in the spectral analysis. Such a study will provide additional constraints on the model spectral functions to better ascertain the reality of the line features. The spectral analysis program used was RMFIT. Of the six GRBs that met the selection criteria, the analysis was performed on only three of them due to a lack of time.

Pangia, Michael J.↗

Revealing Excited‐State Trajectories on Potential Energy Surfaces with Atomic Resolution in Real Time

Abstract Photoexcited molecular trajectories on potential energy surfaces (PESs) prior to thermalization are intimately connected to the photochemical reaction outcome. The excited‐state trajectories of a diplatinum complex featuring photo‐activated metal–metal σ ‐bond formation and associated Pt−Pt stretching motions were detected in real time using femtosecond wide‐angle X‐ray solution scattering. The observed motions correspond well with coherent vibrational wavepacket motions detected by femtosecond optical transient absorption. Two key coordinates for intersystem crossing have been identified, the Pt−Pt bond length and the orientation of the ligands coordinated with the platinum centers, along which the excited‐state trajectories can be projected onto the calculated PESs of the excited states. This investigation has gleaned novel insight into electronic transitions occurring on the time scales of vibrational motions measured in real time, revealing ultrafast nonadiabatic or non‐equilibrium processes along excited‐state trajectories involving multiple excited‐state PESs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing Excited‐State Trajectories on Potential Energy Surfaces with Atomic Resolution in Real Time

Abstract Photoexcited molecular trajectories on potential energy surfaces (PESs) prior to thermalization are intimately connected to the photochemical reaction outcome. The excited‐state trajectories of a diplatinum complex featuring photo‐activated metal–metal σ ‐bond formation and associated Pt−Pt stretching motions were detected in real time using femtosecond wide‐angle X‐ray solution scattering. The observed motions correspond well with coherent vibrational wavepacket motions detected by femtosecond optical transient absorption. Two key coordinates for intersystem crossing have been identified, the Pt−Pt bond length and the orientation of the ligands coordinated with the platinum centers, along which the excited‐state trajectories can be projected onto the calculated PESs of the excited states. This investigation has gleaned novel insight into electronic transitions occurring on the time scales of vibrational motions measured in real time, revealing ultrafast nonadiabatic or non‐equilibrium processes along excited‐state trajectories involving multiple excited‐state PESs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.

47 OTHER INSTRUMENTATION↗

Long-range exciton transport and slow annihilation in two-dimensional hybrid perovskites

Two-dimensional hybrid organic-inorganic perovskites with strongly bound excitons and tunable structures are desirable for optoelectronic applications. Exciton transport and annihilation are two key processes in determining device efficiencies; however, a thorough understanding of these processes is hindered by that annihilation rates are often convoluted with exciton diffusion constants. Here we employ transient absorption microscopy to disentangle quantum-well-thickness-dependent exciton diffusion and annihilation in twodimensional perovskites, unraveling the key role of electron-hole interactions and dielectric screening. The exciton diffusion constant is found to increase with quantum-well thickness, ranging from 0.06 ± 0.03 to 0.34 ± 0.03 cm 2 s –1 , which leads to long-range exciton diffusion over hundreds of nanometers. The exciton annihilation rates are more than one order of magnitude lower than those found in the monolayers of transition metal dichalcogenides. The combination of long-range exciton transport and slow annihilation highlights the unique attributes of two-dimensional perovskites as an exciting class of optoelectronic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyte Immersion Increases Photoconductivity in a Model Polymer Photocathode

Immersing polymer solar cells in aqueous electrolyte for photoelectrochemical (PEC) hydrogen production is likely to cause photophysical changes that could present both challenges and opportunities for engineering functional and durable devices. Herein we study the bulk heterojunction blend poly(4,8-bis(5-(2-ethylhexyl)thiophen-2-yl)benzo[1,2-b:4,5-b']dithiophene-2,6-diyl)-alt-(2-(((2-ethylhexyl)oxy)carbonyl)-3-fluorothieno[3,4-b]thiophene-4,6-diyl):poly(N,N'-di(2-octyldodecyl)naphthalene-1,8:4,5-bis(dicarboximide)-2,6-diyl)-alt-(2,2-bithiophene-5,5'-diyl) (PTB7-Th:N2200) excited-state dynamics in electrolyte from femtosecond to millisecond time scales using pump-probe microwave conductivity and absorption spectroscopy. While the blend swells very little, electrolyte exposure increases the microwave-frequency mobility and possibly the yield of photogenerated charges while also decreasing crystallinity. These results indicate an enhancement in key performance metrics, implying that any limitations on the performance of PEC test devices do not arise from active layer-electrolyte interactions. For the PTB7-Th:N2200 blend or similar photocathode systems, our results indicate that improving the interfacial kinetics and/or the carrier lifetime should be prioritized, not protecting the active layer from the electrolyte. Since this observation may not be universal to all polymer systems, future research should focus on identifying their limiting photophysical processes. electrolyte.

14 SOLAR ENERGY↗

Spatiotemporal Observation of Quasi-Ballistic Transport of Electrons in Graphene

We report spatiotemporal observations of room-temperature quasi-ballistic electron transport in graphene, which is achieved by utilizing a four-layer van der Waals heterostructure to generate free charge carriers. The heterostructure is formed by sandwiching a MoS 2 and MoSe 2 heterobilayer between two graphene monolayers. Transient absorption measurements reveal that the electrons and holes separated by the type-II interface between MoS 2 and MoSe 2 can transfer to the two graphene layers, respectively. Transient absorption microscopy measurements, with high spatial and temporal resolution, reveal that while the holes in one graphene layer undergo a classical diffusion process with a large diffusion coefficient of 65 cm 2 s –1 and a charge mobility of 5000 cm 2 V –1 s –1 , the electrons in the other graphene layer exhibit a quasi-ballistic transport feature, with a ballistic transport time of 20 ps and a speed of 22 km s –1 , respectively. The different in-plane transport properties confirm that electrons and holes move independently of each other as charge carriers. Furthermore, the optical generation of ballistic charge carriers suggests potential applications for such van der Waals heterostructures as optoelectronic materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray Transient Absorption Studies of Exciton Self-Trapping

Here, we present optical pump/X-ray absorption probe studies to probe changes in electronic distribution and local structure upon formation of a self-trapped exciton. The experiments were carried out on the mixed-valence halide-bridged transition metal linear chain charge density wave material [Pt(en 2 )][Pt(en 2 )Cl 2 ]·(ClO 4 ) 4 . Photoinduced changes in the Pt L III XANES spectrum were measured on a picosecond time scale following generation of excitons via optical excitation of the intervalence charge transfer transition. Ab initio FEFF9 modeling of the spectra and the associated angular momentum projected density of states was used to interpret the response. We find photoinduced changes reflecting electronic redistribution and local lattice distortions that correspond to strong localization of the self-trapped state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increased bundle‐sheath leakiness of CO 2 during photosynthetic induction shows a lack of coordination between the C 4 and C 3 cycles

Summary Use of a complete dynamic model of NADP‐malic enzyme C 4 photosynthesis indicated that, during transitions from dark or shade to high light, induction of the C 4 pathway was more rapid than that of C 3 , resulting in a predicted transient increase in bundle‐sheath CO 2 leakiness ( ϕ ). Previously, ϕ has been measured at steady state; here we developed a new method, coupling a tunable diode laser absorption spectroscope with a gas‐exchange system to track ϕ in sorghum and maize through the nonsteady‐state condition of photosynthetic induction. In both species, ϕ showed a transient increase to > 0.35 before declining to a steady state of 0.2 by 1500 s after illumination. Average ϕ was 60% higher than at steady state over the first 600 s of induction and 30% higher over the first 1500 s. The transient increase in ϕ , which was consistent with model prediction, indicated that capacity to assimilate CO 2 into the C 3 cycle in the bundle sheath failed to keep pace with the rate of dicarboxylate delivery by the C 4 cycle. Because nonsteady‐state light conditions are the norm in field canopies, the results suggest that ϕ in these major crops in the field is significantly higher and energy conversion efficiency lower than previous measured values under steady‐state conditions.

59 BASIC BIOLOGICAL SCIENCES↗