Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

CONSTRAINING CHANGES IN THE PROTON-ELECTRON MASS RATIO WITH INVERSION AND ROTATIONAL LINES

We report deep Green Bank Telescope spectroscopy in the redshifted NH{sub 3} (1,1), CS 1-0, and H{sub 2}CO 0{sub 00}-1{sub 01} lines from the z {approx} 0.685 absorber toward B0218+357. The inversion (NH{sub 3}) and rotational (CS, H{sub 2}CO) line frequencies have different dependences on the proton-electron mass ratio {mu}, implying that a comparison between the line redshifts is sensitive to changes in {mu}. A joint three-component fit to the NH{sub 3}, CS, and H{sub 2}CO lines yields [{Delta}{mu}/{mu}] = (-3.5 {+-} 1.2) x 10{sup -7}, from z {approx} 0.685 to today, where the error includes systematic effects from comparing lines from different species and possible frequency-dependent source morphology. Two additional sources of systematic error remain, due to time variability in the source morphology and velocity offsets between nitrogen-bearing and carbon-bearing species. We find no statistically significant ({>=}3{sigma}) evidence for changes in {mu} and obtain the stringent 3{sigma} constraint, [{Delta}{mu}/{mu}] < 3.6 x 10{sup -7}, over 6.2 Gyr; this is the best present limit on temporal changes in {mu} from any technique, and for any look-back time, by a factor {approx}>5.

79 ASTRONOMY AND ASTROPHYSICS↗

High contrast Kr gas jet K{alpha} x-ray source for high energy density physics experiments

A high contrast 12.6 keV Kr K{alpha} source has been demonstrated on the petawatt-class Titan laser facility using strongly clustering Kr gas jet targets. The contrast ratio (K{alpha} to continuum) is 65, with a competitive ultrashort pulse laser to x-ray conversion efficiency of 10{sup -5}. Filtered shadowgraphy indicates that the Kr K{alpha} and K{beta} x rays are emitted from a roughly 1x2 mm{sup 2} emission volume, making this source suitable for area backlighting and scattering. Spectral calculations indicate a typical bulk electron temperature of 50-70 eV (i.e., mean ionization state 13-16), based on the observed ratio of K{alpha} to K{beta}. Kr gas jets provide a debris-free high energy K{alpha} source for time-resolved diagnosis of dense matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADVANCES IN THE RXTE PROPORTIONAL COUNTER ARRAY CALIBRATION: NEARING THE STATISTICAL LIMIT

During its 16 years of service, the Rossi X-Ray Timing Explorer (RXTE) mission has provided an extensive archive of data, which will serve as a primary source of high cadence observations of variable X-ray sources for fast timing studies. It is, therefore, very important to have the most reliable calibration of RXTE instruments. The Proportional Counter Array (PCA) is the primary instrument on board RXTE which provides data in 3-50 keV energy range with submillisecond time resolution in up to 256 energy channels. In 2009, the RXTE team revised the response residual minimization method used to derive the parameters of the PCA physical model. The procedure is based on the residual minimization between the model spectrum for Crab Nebula emission and a calibration data set consisting of a number of spectra from the Crab and the on-board Am{sub 241} calibration source, uniformly covering the whole RXTE mission operation period. The new method led to a much more effective model convergence and allowed for better understanding of the PCA energy-to-channel relationship. It greatly improved the response matrix performance. We describe the new version of the RXTE/PCA response generator PCARMF v11.7 (HEASOFT Release 6.7) along with the corresponding energy-to-channel conversion table (version e05v04) and their difference from the previous releases of PCA calibration. The new PCA response adequately represents the spectrum of the calibration sources and successfully predicts the energy of the narrow iron emission line in Cas-A throughout the RXTE mission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis in Motion Initiative – Summarization Capability

Analysts are tasked with integrating information from multiple data sources for important and timely decision making. What if sense making and overall situation awareness could be improved through visualization techniques? The Analysis in Motion initiative is advancing the ability to summarize and abstract multiple streams and static data sources over time.

97 MATHEMATICS AND COMPUTING↗

Conceptual design of the time-of-flight backscattering spectrometer, MIRACLES, at the European Spallation Source

In this work, we present the conceptual design of the backscattering time-of-flight spectrometer MIRACLES approved for construction at the long-pulse European Spallation Source (ESS). MIRACLES’s unparalleled combination of variable resolution, high flux, extended energy, and momentum transfer (0.2–6 Å{sup −1}) ranges will open new avenues for neutron backscattering spectroscopy. Its remarkable flexibility can be attributed to 3 key elements: the long-pulse time structure and low repetition rate of the ESS neutron source, the chopper cascade that tailors the moderator pulse in the primary part of the spectrometer, and the bent Si(111) analyzer crystals arranged in a near-backscattering geometry in the secondary part of the spectrometer. Analytical calculations combined with instrument Monte-Carlo simulations show that the instrument will provide a variable elastic energy resolution, δ(ħ ω), between 2 and 32 μeV, when using a wavelength of λ ≈ 6.267 Å (Si(111)-reflection), with an energy transfer range, ħ ω, centered at the elastic line from −600 to +600 μeV. In addition, when selecting λ ≈ 2.08 Å (i.e., the Si(333)-reflection), δ(ħ ω) can be relaxed to 300 μeV and ħ ω from about 10 meV in energy gain to ca −40 meV in energy loss. Finally, the dynamic wavelength range of MIRACLES, approximately 1.8 Å, can be shifted within the interval of 2–20 Å to allow the measurement of low-energy inelastic excitations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RESONANT SCATTERING AND Ly{alpha} RADIATION EMERGENT FROM NEUTRAL HYDROGEN HALOS

With a state-of-the-art numerical method used for solving the integral-differential equation of radiative transfer, we investigate the flux of the Ly{alpha} photon {nu}{sub 0} emergent from an optically thick halo containing a central light source. Our focus is on the time-dependent effects of the resonant scattering. We first show that the frequency distribution of photons in the halo is quickly approaching a locally thermalized state around the resonant frequency, even when the mean intensity of the radiation is highly time dependent. Since initial conditions are forgotten during the thermalization, some features of the flux, such as the two-peak structure of its profile, are actually independent of the intrinsic width and time behavior of the central source, if the emergent photons are mainly from photons in the thermalized state. In this case, the difference |{nu}{sub {+-}} - {nu}{sub 0}|, where {nu}{sub {+-}} are the frequencies of the two peaks of the flux, cannot be less than 2 times the Doppler broadening. We then study the radiative transfer in the case where the light emitted from the central source is a flash. We calculate the light curves of the flux from the halo. It shows that the flux is still a flash. The time duration of the flash for the flux, however, is independent of the original time duration of the light source but depends on the optical depth of the halo. Therefore, the spatial transfer of resonant photons is a diffusion process, even though it is not a purely Brownian diffusion. This property enables an optically thick halo to trap and store thermalized photons around {nu}{sub 0} for a long time after the cessation of the central source emission. The photons trapped in the halo can yield delayed emission, of which the profile also shows typical two-peak structure as that from locally thermalized photons. Possible applications of these results are addressed.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiplexed photoionization mass spectrometry investigation of the O( 3 P) + propyne reaction

Here, the reaction of O( 3 P) + propyne (C 3 H 4 ) was investigated at 298 K and 4 Torr using time-resolved multiplexed photoionization mass spectrometry and a synchrotron-generated tunable vacuum ultraviolet light source. The time-resolved mass spectra of the observed products suggest five major channels under our conditions: C 2 H 3 + HCO, CH 3 + HCCO, H + CH 3 CCO, C 2 H 4 + CO, and C 2 H 2 + H 2 + CO. The relative branching ratios for these channels were found to be 1.00, (0.35 ± 0.11), (0.18 ± 0.10), (0.73 ± 0.27), and (1.31 ± 0.62). In addition, we observed signals consistent with minor production of C 3 H 3 + OH and H 2 + CH 2 CCO, although we cannot conclusively assign them as direct product channels from O( 3 P) + propyne. The direct abstraction mechanism plays only a minor role (≤1%), and we estimate that O( 3 P) addition to the central carbon of propyne accounts for 10% of products, with addition to the terminal carbon accounting for the remaining 89%. The isotopologues observed in experiments using d1-propyne (CH 3 CCD) and analysis of product branching in light of previously computed stationary points on the singlet and triplet potential energy surfaces (PESs) relevant to O( 3 P) + propyne suggest that, under our conditions, (84 ± 14)% of the observed product channels from O( 3 P) + propyne result from intersystem crossing from the initial triplet PES to the lower-lying singlet PES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE EFFECT OF METALLICITY ON THE DETECTION PROSPECTS FOR GRAVITATIONAL WAVES

Data from the Sloan Digital Sky Survey ({approx}300,000 galaxies) indicate that recent star formation (within the last 1 billion years) is bimodal: half of the stars form from gas with high amounts of metals (solar metallicity) and the other half form with small contribution of elements heavier than helium ({approx}10%-30% solar). Theoretical studies of mass loss from the brightest stars derive significantly higher stellar-origin black hole (BH) masses ({approx}30-80 M {sub sun}) than previously estimated for sub-solar compositions. We combine these findings to estimate the probability of detecting gravitational waves (GWs) arising from the inspiral of double compact objects. Our results show that a low-metallicity environment significantly boosts the formation of double compact object binaries with at least one BH. In particular, we find the GW detection rate is increased by a factor of 20 if the metallicity is decreased from solar (as in all previous estimates) to a 50-50 mixture of solar and 10% solar metallicity. The current sensitivity of the two largest instruments to neutron star-neutron star (NS-NS) binary inspirals (VIRGO: {approx}9 Mpc; LIGO: {approx}18) is not high enough to ensure a first detection. However, our results indicate that if a future instrument increased the sensitivity to {approx}50-100 Mpc, a detection of GWs would be expected within the first year of observation. It was previously thought that NS-NS inspirals were the most likely source for GW detection. Our results indicate that BH-BH binaries are {approx}25 times more likely sources than NS-NS systems and that we are on the cusp of GW detection.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating the QSO contribution to the 21-cm signal from the Cosmic Dawn

The upcoming radio interferometer Square Kilometre Array (SKA) is expected to directly detect the redshifted 21-cm signal from the neutral hydrogen present during the Cosmic Dawn. Temperature fluctuations from X-ray heating of the neutral intergalactic medium can dominate the fluctuations in the 21-cm signal from this time. This heating depends on the abundance, clustering, and properties of the X-ray sources present, which remain highly uncertain. We present a suite of three new large-volume, 349\,Mpc a side, fully numerical radiative transfer simulations including QSO-like sources, extending the work previously presented in Ross et al. (2017). The results show that our QSOs have a modest contribution to the heating budget, yet significantly impact the 21-cm signal. Initially, the power spectrum is boosted on large scales by heating from the biased QSO-like sources, before decreasing on all scales. Fluctuations from images of the 21-cm signal with resolutions corresponding to SKA1-Low at the appropriate redshifts are well above the expected noise for deep integrations, indicating that imaging could be feasible for all the X-ray source models considered. The most notable contribution of the QSOs is a dramatic increase in non-Gaussianity of the signal, as measured by the skewness and kurtosis of the 21-cm probability distribution functions. Furthermore, in the case of late Lyman-$\alpha$ saturation, this non-Gaussianity could be dramatically decreased particularly when heating occurs earlier. We conclude that increased non-Gaussianity is a promising signature of rare X-ray sources at this time, provided that Lyman-$\alpha$ saturation occurs before heating dominates the 21-cm signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancement of Distribution System Resilience Through the Application of Volt-Var Regulation Devices

This paper discusses a practical implementation of locating and sizing dynamic reactive compensation using an impedance matrix (Zbus) approach to improve distribution system resilience in scenarios with high penetration of distributed resources. The modeled system is a 14.2 kV radial residential system modified to be fed by a combination of traditional sources and solar resources. Time-varying loads and PV sources are connected along the feeder to simulate the challenging operational voltage regulation scenarios faced by Modern Distribution Systems. Additionally, enhancement of the resilience of the electrical system is demonstrated through analyzing the effect of a topology change to the system. This study uses the GridLAB-D software.

42 ENGINEERING↗

A Suzaku View of Accretion-powered X-Ray Pulsar GX 1+4

We present results obtained from a Suzaku observation of the accretion-powered X-ray pulsar GX 1+4. A broadband continuum spectrum of the pulsar was found to be better described by a simple model consisting of a blackbody component and an exponential cutoff power law than the previously used compTT continuum model. Though the pulse profile had a sharp dip in soft X-rays (<10 keV), phase-resolved spectroscopy confirmed that the dimming was not due to an increase in photoelectric absorption. Phase-sliced spectral analysis showed the presence of a significant spectral modulation beyond 10 keV except for the dip phase. A search for the presence of a cyclotron resonance scattering feature in the Suzaku spectra yielded a negative result. Iron K-shell (K{sub α} and K{sub β}) emission lines from nearly neutral iron ions (<Fe iii) were clearly detected in the source spectrum. A significant K{sub α} emission line from almost neutral Ni atoms was detected for the first time in this source. We estimated an iron abundance of ∼80% of the solar value and an Ni/Fe abundance ratio of about two times the solar value. We searched for an iron Ly{sub α} emission line and found a significant improvement in the spectral fitting by inclusion of this line. We found a clear intensity modulation of the iron K{sub α} line with the pulse phase with an amplitude of 7%. This finding favored an inhomogeneous fluorescent region with a radius much smaller than the size (∼3 × 10{sup 12} cm) estimated by an assumption of homogeneous matter.

79 ASTRONOMY AND ASTROPHYSICS↗

VERITAS and Multiwavelength Observations of the Blazar B3 2247+381 in Response to an IceCube Neutrino Alert

While the sources of the diffuse astrophysical neutrino flux detected by the IceCube Neutrino Observatory are still largely unknown, one of the promising methods to improve our understanding of them is investigating the potential temporal and spatial correlations between neutrino alerts and the electromagnetic radiation from blazars. We report on the multiwavelength target-of-opportunity observations of the blazar B3 2247+381, taken in response to an IceCube multiplet alert for a cluster of muon neutrino events compatible with the source location between 2022 May 20 and 2022 November 10. B3 2247+381 was not detected with VERITAS during this time period. The source was found to be in a low-flux state in the optical, ultraviolet, and gamma-ray bands for the time interval corresponding to the neutrino event, but was detected in the hard X-ray band with NuSTAR during this period. We find the multiwavelength spectral energy distribution is described well using a simple one-zone leptonic synchrotron self-Compton radiation model. Moreover, assuming the neutrinos originate from hadronic processes within the jet, the neutrino flux would be accompanied by a photon flux from the cascade emission, and the integrated photon flux required in such a case would significantly exceed the total multiwavelength fluxes and the VERITAS upper limits presented here. The lack of flaring activity observed with VERITAS, combined with the low multiwavelength flux levels, as well as the significance of the neutrino excess being at a 3σ level (uncorrected for trials), makes B3 2247+381 an unlikely source of the IceCube multiplet. We conclude that the neutrino excess is likely a background fluctuation.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing spectroscopy and microscopy with emerging methods in photon correlation and quantum illumination

Quantum optics has led to important advancements in our ability to prepare and detect correlations between individual photons. Its principles are increasingly translated into nanoscale characterization tools, furthering methods in spectroscopy, microscopy and metrology. Here, in this Review, we discuss the rapid progress in this field driven by advanced technologies of single-photon detectors and quantum-light sources, including time-resolved single-photon counting cameras, superconducting nanowire single-photon detectors and entangled photon sources of increasing brightness. We emphasize emerging applications in super-resolution microscopy, measurements below classical noise limits and photon-number-resolved spectroscopy—a powerful paradigm for the characterization of nanoscale electronic materials. We conclude by discussing key technological challenges and future opportunities in materials science and bionanophotonics alike.

Tsao, Chieh [University of California, Berkeley, C↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

Hanford Tank Vapors in Worker Breathing Zones - Source, Dispersion, and Receptor Data - 20373

A wide range of organic and inorganic chemicals from historical Hanford Site processes are now stored in 177 underground storage tanks at the Hanford tank farms. Workers at the Hanford tank farms have expressed concerns about chemical vapor exposures for many years. During the spring of 2014, worker reports of chemical odors and/or symptoms prompted the development of the Savannah River National Laboratory Hanford Tank Vapor Assessment Team (TVAT) and their resulting independent assessment and recommendations concerning tank farm worker reports of vapors. The Tank Vapor Assessment report included a hypothesis that 'vapors coming out of tanks in high concentration (bolus) plumes sporadically intersected with the breathing zones of workers, resulting in brief but intense exposures to some workers.' The focus of this effort is to present current knowledge to describe the mechanisms by which workers may experience short duration vapor concentrations above background in the tank farms environment. The TVAT hypothesis that workers have experienced concentrations approaching 80% of the tank headspace up to 3 meters (10 feet) from tank sources is not supported by sampling data or modeling results. Modeling indicates that concentrations are quickly reduced from the source, and that the upper end of predicted concentrations at worker breathing zones are a factor of 10 or more lower than source concentrations. Area measurements corroborate the fact that worker breathing zone concentrations are 10 to 100 times lower than source concentrations, and events with elevated concentrations are rare. These reduced vapor concentration levels may result in detectable odors or irritation, depending on a worker's specific odor threshold and sensitivity to the chemical species. Short-duration vapor events may be mitigated by evaluating daily atmospheric conditions in conjunction with planned tank farm activities. Monitoring changing conditions related to tank vapors concentrations at the source and within worker breathing zone is also an important step to protect workers from short duration elevated concentration events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Covariance Modifications to Subspace Bases

Adaptive signal processing algorithms that rely upon representations of signal and noise subspaces often require updates to those representations when new data become available. Subspace representations frequently are estimated from available data with singular value (SVD) decompositions. Subspace updates require modifications to these decompositions. Updates can be performed inexpensively provided they are low-rank. A substantial literature on SVD updates exists, frequently focusing on rank-1 updates (see e.g. [Karasalo, 1986; Comon and Golub, 1990, Badeau, 2004]). In these methods, data matrices are modified by addition or deletion of a row or column, or data covariance matrices are modified by addition of the outer product of a new vector. A recent paper by Brand [2006] provides a general and efficient method for arbitrary rank updates to an SVD. The purpose of this note is to describe a closely-related method for applications where right singular vectors are not required. This note also describes the SVD updates to a particular scenario of interest in seismic array signal processing. The particular application involve updating the wideband subspace representation used in seismic subspace detectors [Harris, 2006]. These subspace detectors generalize waveform correlation algorithms to detect signals that lie in a subspace of waveforms of dimension d {ge} 1. They potentially are of interest because they extend the range of waveform variation over which these sensitive detectors apply. Subspace detectors operate by projecting waveform data from a detection window into a subspace specified by a collection of orthonormal waveform basis vectors (referred to as the template). Subspace templates are constructed from a suite of normalized, aligned master event waveforms that may be acquired by a single sensor, a three-component sensor, an array of such sensors or a sensor network. The template design process entails constructing a data matrix whose columns contain the master event waveform data, then performing a singular value decomposition on the data matrix to extract an orthonormal basis for the waveform suite. The template typically is comprised of a subset of the left singular vectors corresponding to the larger singular values. The application involves updating a subspace template when new data become available, i.e. when new defining events are detected for a particular source. It often is the case that the waveforms corresponding to a particular source drift over time [Harris, 2001]. The Green's functions describing propagation can be altered because of changes in the source region. For example, if the source is a mine, signals from explosions may change gradually as a pit is extended (the source moves) or the scattering topography is altered by excavation. This motivates a tracking adjustment to a subspace representation. This note also comments on SVD updates for a related problem. In realistic pipeline operations it often is the case that data from one or more channels of an array are unusable (dead channels, channels with prolific dropouts, etc.). In such cases it is desirable to modify an array subspace template to operate on data only from the remaining usable channels. Furthermore, it is desirable to modify the templates directly without recourse to the original data matrix. Usually the template design process is separate from the application of the template in a detector to a continuous data stream. Consequently, the original data matrix may not be available for template modification at detector run time.

58 GEOSCIENCES↗

Time-dependent nonequilibrium soft x-ray response during a spin crossover

Here, the rapid development of high-brilliance pulsed X-ray sources with femtosecond time resolution has created a need for a better theoretical understanding of the time-dependent soft-X-ray response of dissipative many-body quantum systems. It is demonstrated how soft-X-ray spectroscopies, such as X-ray absorption and resonant inelastic X-ray scattering at transition-metal L-edges, can provide insight into intersystem crossings, such as a spin crossover. The photoinduced doublet-to-quartet spin crossover on cobalt in Fe-Co Prussian blue analogues is used as an example to demonstrate how the X-ray response is affected by the dissipative nonequilibrium dynamics. The time-dependent soft-X-ray spectra provide a wealth of information that reflect the changes in the nonequilibrium initial state via continuously changing spectral lineshapes that cannot be decomposed into initial photoexcited and final metastable spectra, strong broadenings, a collapse of clear selection rules during the intersystem crossing, strong fluctuations in the isotropic branching ratio in X-ray absorption, and crystal-field collapse/oscillations and strongly time-dependent anti-Stokes processes in RIXS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DETECTION, LOCALIZATION, AND CHARACTERIZATION OF GRAVITATIONAL WAVE BURSTS IN A PULSAR TIMING ARRAY

Efforts to detect gravitational waves by timing an array of pulsars have traditionally focused on stationary gravitational waves, e.g., stochastic or periodic signals. Gravitational wave bursts-signals whose duration is much shorter than the observation period-will also arise in the pulsar timing array waveband. Sources that give rise to detectable bursts include the formation or coalescence of supermassive black holes (SMBHs), the periapsis passage of compact objects in highly elliptic or unbound orbits about an SMBH, or cusps on cosmic strings. Here, we describe how pulsar timing array data may be analyzed to detect and characterize these bursts. Our analysis addresses, in a mutually consistent manner, a hierarchy of three questions. (1) What are the odds that a data set includes the signal from a gravitational wave burst? (2) Assuming the presence of a burst, what is the direction to its source? (3) Assuming the burst propagation direction, what is the burst waveform's time dependence in each of its polarization states? Applying our analysis to synthetic data sets, we find that we can detect gravitational waves even when the radiation is too weak to either localize the source or infer the waveform, and detect and localize sources even when the radiation amplitude is too weak to permit the waveform to be determined. While the context of our discussion is gravitational wave detection via pulsar timing arrays, the analysis itself is directly applicable to gravitational wave detection using either ground- or space-based detector data.

79 ASTRONOMY AND ASTROPHYSICS↗