Managing the Mars Science Laboratory Thermal Vacuum Test for Safety and Success

The Mars Science Laboratory is a NASA/JPL mission to send the next generation of rover to Mars. Originally slated for launch in 2009, development problems led to a delay in the project until the next launch opportunity in 2011. Amidst the delay process, the Launch/Cruise Solar Thermal Vacuum Test was undertaken as risk reduction for the project. With varying maturity and capabilities of the flight and ground systems, undertaking the test in a safe manner presented many challenges. This paper describes the technical and management challenges and the actions undertaken that led to the ultimate safe and successful execution of the test.

Evans, Jordan P.↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Hubble Space telescope thermal cycle test report for large solar array samples with BSFR cells (Sample numbers 703 and 704)

The Hubble space telescope (HST) solar array was designed to meet specific output power requirements after 2 years in low-Earth orbit, and to remain operational for 5 years. The array, therefore, had to withstand 30,000 thermal cycles between approximately +100 and -100 C. The ability of the array to meet this requirement was evaluated by thermal cycle testing, in vacuum, two 128-cell solar cell modules that exactly duplicated the flight HST solar array design. Also, the ability of the flight array to survive an emergency deployment during the dark (cold) portion of an orbit was evaluated by performing a cold-roll test using one module.

Alexander, D. W.↗

Multiphysics Simulations of Thermal Shock Testing of Nanofibrous High Power Targets

Increase of primary beam power for neutrino beam-lines leads to a reduced lifespan for production targets. New concepts for robust targets are emerging from the field of High Power Targetry (HPT); one idea being investigated by the HPT R&D Group at Fermilab is an electrospun nanofiber target. As part of their evaluation, samples with different densities were sent to the HiRadMat facility at CERN for thermal shock tests. The samples with the higher density, irradiated under a high intensity beam pulse, exhibit major damage at the impact site whereas those with the lower density show no apparent damage. The exact cause of this failure was unclear at the time. In this paper, we present the results of multiphysics simulations of the thermal shock experienced by the nanofiber targets that suggest the failure originates from the reduced permeability of the high density sample to air flow. The air present in the porous target expands due to heating from the beam, but is unable to flow freely in the high density sample, resulting in a larger back pressure that blows apart the nanofiber mat. We close with a discussion on how to further validate this hypothesis.

43 PARTICLE ACCELERATORS↗

Mir Cooperative Solar Array Project Accelerated Life Thermal Cycling Test

The Mir Cooperative Solar Array (MCSA) project was a joint U.S./Russian effort to build a photovoltaic (PV) solar array and deliver it to the Russian space station Mir. The MCSA will be used to increase the electrical power on Mir and provide PV array performance data in support of Phase 1 of the International Space Station. The MCSA was brought to Mir by space shuttle Atlantis in November 1995. This report describes an accelerated thermal life cycle test which was performed on two samples of the MCSA. In eight months time, two MCSA solar array 'mini' panel test articles were simultaneously put through 24,000 thermal cycles. There was no significant degradation in the structural integrity of the test articles and no electrical degradation, not including one cell damaged early and removed from consideration. The nature of the performance degradation caused by this one cell is briefly discussed. As a result of this test, changes were made to improve some aspects of the solar cell coupon-to-support frame interface on the flight unit. It was concluded from the results that the integration of the U.S. solar cell modules with the Russian support structure would be able to withstand at least 24,000 thermal cycles (4 years on-orbit). This was considered a successful development test.

Hoffman, David J.↗

Advanced Failure Determination Measurement Techniques Used in Thermal Fatigue Life Testing of Electronic Packaging

Thermal fatigue life testing of various electronic packaging technologies is being performed by the Reliability Technology Group at the Jet Propulsion Laboratory. These testing efforts are in progress to improve uderstanding of the reliability issues associated with low volume packaging technologies for space applications and to develop qualification and acceptance approaches for these technologies. The work described here outlines the electrical failure detection techniques used during testing by documenting the circuits and components used to make these measurements, the sensitivity of the measurements, and the applicability of each specific measurement.

fatigue surface mount measurement testing thermal ↗

Multiphysics Simulations of Thermal Shock Testing of Nanofibrous High Power Targets

Increase of primary beam power for neutrino beam-lines leads to a reduced lifespan for production targets. The field of High Power Targetry (HPT) is generating new concepts to meet the need for robust targets. One idea being investigated by the HPT Research and Development Group at Fermilab is an electrospun nanofiber target. As part of their evaluation, samples with different densities were sent to the HiRadMat facility at CERN for thermal shock tests. The samples with the higher density, irradiated under a high intensity beam pulse, exhibit major damages at the impact site whereas those with the lower density show no apparent damages. The exact cause of this failure was unclear at the time. In this paper, we present the results of multiphysics simulations of the thermal shock experienced by the nanofiber targets that suggest the failure originates from the reduced permeability of the high density sample to airflow. The air present in the porous target expands due to heating from the beam, but is unable to flow freely in the high density sample, resulting in a larger back pressure that blows apart the mat. We close with a discussion on how to further validate this hypothesis.

43 PARTICLE ACCELERATORS↗

Thermal Stability Testing of a Fischer-Tropsch Fuel and Various Blends with Jet A

Fischer-Tropsch (F-T) jet fuel composition differs from petroleum-based, conventional commercial jet fuel because of differences in feedstock and production methodology. Fischer-Tropsch fuel typically has a lower aromatic and sulfur content and consists primarily of iso and normal parafins. The ASTM D3241 specification for Jet Fuel Thermal Oxidation Test (JFTOT) break point testing method was used to test the breakpoint of a baseline conventional Jet A, a commercial grade F-T jet fuel, and various blends of this F-T fuel in Jet A. The testing completed in this report was supported by the NASA Fundamental Aeronautics Subsonics Fixed Wing Project.

Klettlinger, Jennifer Suder↗

Update of ASHRAE Standard 140 Section 5.2 and Related Sections (BESTEST Building Thermal Fabric Test Cases)

This report documents new work intended to update the current building thermal fabric software-to-software comparative test specifications and example results of ANSI/ASHRAE Standard 140-2017, Sections 5.2.1, 5.2.2, 5.2.3, and related supporting sections. The Building Energy Simulation Test and Diagnostic Method (BESTEST) test specification and example results that provide the basis for these Standard 140 sections were originally published in 1995. The state of the art in building energy simulation modeling has advanced since then. Additionally, comments on the test specification over the years highlighted ambiguities, further necessitating the update to the original work. This new work was conducted for the U.S. Department of Energy (DOE) by Argonne National Laboratory (Argonne) and National Renewable Energy Laboratory (NREL), in collaboration with a working group of international experts associated with the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standing Standard Project Committee (SSPC) 140. SSPC 140 is responsible for ANSI/ASHRAE Standard 140. The new work, presented in this report, defined the test cases and specifications such that building energy simulation programs with time steps of one hour or less can perform the tests. Revisions to the test specification and update of example results follow the vetting process of iterative field trials established for previous BESTEST work that has been adapted for ASHRAE Standard 140.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integral and Separate Effects Tests for Thermal Hydraulics Code Validation for Liquid-Salt Cooled Nuclear Reactors

The objective of the 3-year project was to collect integral effects test (IET) data to validate the RELAP5-3D code and other thermal hydraulics codes for use in predicting the transient thermal hydraulics response of liquid salt cooled reactor systems, including integral transient response for forced and natural circulation operation. The reference system for the project is a modular, 900-MWth Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a specific type of Fluoride salt-cooled High temperature Reactor (FHR). Two experimental facilities were developed for thermal-hydraulic integral effects tests (IETs) and separate effects tests (SETs). The facilities use simulant fluids for the liquid fluoride salts, with very little distortion to the heat transfer and fluid dynamics behavior. The CIET Test Bay facility was designed, built, and operated. IET data for steady state and transient natural circulation was collected. SET data for convective heat transfer in pebble beds and straight channel geometries was collected. The facility continues to be operational and will be used for future experiments, and for component development. The CIET 2 facility is larger in scope, and its construction and operation has a longer timeline than the duration of this grant. The design for the CIET 2 facility has drawn heavily on the experience and data collected on the CIET Test Bay, and it was completed in parallel with operation of the CIET Test Bay. CIET 2 will demonstrate start-up and shut-down transients and control logic, in addition to LOFC and LOHS transients, and buoyant shut down rod operation during transients. Design of the CIET 2 Facility is complete, and engineering drawings have been submitted to an external vendor for outsourced quality controlled construction. CIET 2 construction and operation continue under another NEUP grant. IET data from both CIET facilities is to be used for validation of system codes used for FHR modeling, such as RELAP5-3D. A set of numerical models were developed in parallel to the experimental work. RELAP5-3D models were developed for the salt-cooled PB-AHTR, and for the simulat fluid CIET natural circulation experimental loop. These models are to be validated by the data collected from CIET. COMSOL finite element models were used to predict the temperature and fluid flow distribution in the annular pebble bed core; they were instrumental for design of SETs, and they can be used for code-to-code comparisons with RELAP5-3D. A number of other small SETs, and numerical models were constructed, as needed, in support of this work. The experiments were designed, constructed and performed to meet CAES quality assurance requirements for test planning, implementation, and documentation; equipment calibration and documentation, procurement document control; training and personnel qualification; analysis/modeling software verification and validation; data acquisition/collection and analysis; and peer review.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Stability Testing of Fischer-Tropsch Fuel and Various Blends with Jet A, as Well as Aromatic Blend Additives

Fischer-Tropsch (F-T) jet fuel composition differs from petroleum-based, conventional commercial jet fuel because of differences in feedstock and production methodology. Fischer-Tropsch fuel typically has a lower aromatic and sulfur content and consists primarily of iso and normal parafins. The ASTM D3241 specification for Jet Fuel Thermal Oxidation Test (JFTOT) break point testing method was used to test the breakpoint of a baseline conventional Jet A, a commercial grade F-T jet fuel, and various blends of this F-T fuel in Jet A. The testing completed in this report was supported by the NASA Fundamental Aeronautics Subsonics Fixed Wing Project.

Klettlinger, J.↗

ONE-DIMENSIONAL TIME TO EXPLOSION (THERMAL SENSITIVITY) TESTS ON PETN, PBX-9407, LX-10, AND LX-17

Incidents caused by fire and combat operations can heat energetic materials that may lead to thermal explosion and result in structural damage and casualty. Some explosives may thermally explode at fairly low temperatures (< 100 C) and the violence from thermal explosion may cause a significant damage. Thus it is important to understand the response of energetic materials to thermal insults. The One Dimensional Time to Explosion (ODTX) system at the Lawrence Livermore National Laboratory has been used for decades to measure times to thermal explosion, threshold thermal explosion temperature, and determine the kinetic parameters of thermal decomposition of energetic materials. Samples of different configurations (pressed part, powder, paste, and liquid) can be tested in the system. The ODTX testing can also provide useful data for assessing the thermal explosion violence of energetic materials. This report summarizes the results of our recent ODTX experiments on PETN powder, PBX-9407 pressed part, LX-10 pressed part, LX-17 pressed part and compares the test data that were obtained decades ago with the older version of ODTX system. Test results show the thermal sensitivity of various materials tested in the following order: PETN> PBX-9407 > LX-10 > LX-17.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal cycling testing to failure of a ceramic column grid array package for space applications

Ceramic column grid array (CCGA) packages have been used increasingly in logic and microprocessor functions, telecommunications, flight avionics boards, payload electronics boards, engineering navigational and science cameras, electronic assemblies, and other applications, because of their inherent advantages such as high electrical interconnect density, very good thermal and electrical performance, and compatibility with standard surface-mount technology (SMT) packaging assembly processes. Because these advanced electronic packages tend to have less solder-joint strain-relief than do leaded flat-pack electronic packages, the reliability of CCGA packages in challenging thermal environments is a very important consideration for their short- and long-term use in JPL-NASA space missions. In this study, we assembled daisy chains of polyimide printed wiring boards from CCGA-interconnect packages, inspected the boards nondestructively, and then subjected them to thermal cycling to assess their reliability in thermal environments from +125°C to -40°C±25°C. The test hardware consists of a CCGA 1752 package (CN version). The package was divided into four daisy-chained sections that were electrically monitored for their continuity during thermal cycling. The CCGA 1752 package is roughly 45 mm × 45 mm with a 42-mm × 42-mm array of 80%/20% Pb/Sn columns on a 1.00-mm pitch. The resistance of the daisy-chained CCGA interconnects was continuously monitored during thermal cycling in a gaseous nitrogen environment. Electrical continuity resistance measurements as a function of thermal cycling are reported here; tests to date have shown significant change to an open circuit in daisy-chain resistance as a function of thermal cycling. The change in interconnect resistance becomes increasingly noticeable with increasing number of thermal cycles. This paper describes the experimental thermal-cycling test results of CCGA 1752 package reliability testing under an extremely wide temperature range. The first failure was observed at 1479th thermal cycle. We report the thermal-cycle reliability test data for ~2500 thermal cycles.

Ramesham, Rajeshuni↗

Comparison of Exploration Portable Life Support Subsystem (xPLSS) Thermal Modeling to Thermal Vacuum Testing

To support NASA’s goal to return to the Moon through the Artemis mission, the development of an exploration portable life support system (xPLSS) has been conducted at Johnson Space Center (JSC). As part of this development process, a large system level thermal/fluid model of the xPLSS was developed using Thermal Desktop and an in-house human model (METMAN). The xPLSS model was used throughout the design process to predict the performance and temperature of nearly all components within the xPLSS. In the fall of 2023, the design, verification, and testing (DVT) unit of the xPLSS was tested in a thermal vacuum (TVAC) chamber at JSC. This testing consisted of combining the xPLSS with an upper torso of the exploration pressure garment system (xPGS) and simulating five extravehicular activities (EVAs) in extreme thermal conditions (two cold EVAs and three hot EVAs). The data generated in this test series provided system level data of the xPLSS operating in vacuum and at flight-like environmental temperatures for the first time. This data was compared to results output by the xPLSS system model to assess the accuracy of previous analyses and improve the fidelity and accuracy of the xPLSS system model. The comparison between model and test hardware provides valuable insight that will help improve the design and fidelity of next generation space suits. In general, comparison between test data and model data generally showed slightly un-conservative values (model predicting colder temperatures than test in hot environments, and hotter temperatures than test in cold environments). Model assumptions and test assumptions were assessed to understand potential causes of some of these sources in error. Recommendations to improve the fidelity of the xPLSS model were also made based on the results presented in this paper.

xPLSS↗

Comparison of Exploration Portable Life Support Subsystem (xPLSS) Thermal Modeling to Thermal Vacuum Testing

To support NASA’s goal to return to the Moon through the Artemis Mission, the development of an Exploration Portable Life Support Subsystem (xPLSS) has been conducted at Johnson Space Center (JSC). As part of this development process, a large system level thermal/fluid model of the xPLSS was developed using Thermal Desktop and an in-house human model (METMAN). The xPLSS model was used throughout the design process to predict the performance and temperature of nearly all components within the xPLSS. In the fall of 2023, the Design, Verification, and Testing (DVT) unit of the xPLSS was tested in a thermal vacuum (TVAC) chamber at JSC. This testing consisted of combining the xPLSS with an upper torso of the Exploration Pressure Garment System (xPGS) and simulating five Extravehicular Activities (EVAs) in extreme thermal conditions (two cold EVAs and three hot EVAs). The data generated in this test series provided system level data of the xPLSS operating in vacuum and at flight-like environmental temperatures for the first time. These data were compared to results output by the xPLSS system model to assess the accuracy of previous analyses and improve the fidelity and accuracy of the xPLSS system model. The comparison between model and test hardware provides valuable insight that will help improve the design and fidelity of next generation space suits. In general, comparison between test data and model data generally showed slightly un-conservative values (model predicting colder temperatures than test in hot environments, and hotter temperatures than test in cold environments). Model assumptions and test assumptions were assessed to understand potential causes of some of these sources in error. Recommendations to improve the fidelity of the xPLSS model were also made based on the results presented in this paper.

xPLSS↗

Warm Water Oxidation Verification – Scoping and Stirred Reactor Tests

Scoping tests to evaluate the effects of agitation and pH adjustment on simulant sludge agglomeration and uranium metal oxidation at ~95°C were performed under Test Instructions(a,b) and as per sections 5.1 and 5.2 of this Test Plan prepared by AREVA. (c) The thermal testing occurred during the week of October 4-9, 2010. The results are reported here. For this testing, two uranium-containing simulant sludge types were evaluated: (1) a full uranium-containing K West (KW) container sludge simulant consisting of nine predominant sludge components; (2) a 50:50 uranium-mole basis mixture of uraninite [U(IV)] and metaschoepite [U(VI)]. This scoping study was conducted in support of the Sludge Treatment Project (STP) Phase 2 technology evaluation for the treatment and packaging of K-Basin sludge. The STP is managed by CH2M Hill Plateau Remediation Company (CHPRC) for the U.S. Department of Energy. Warm water (~95°C) oxidation of sludge, followed by immobilization, has been proposed by AREVA and is one of the alternative flowsheets being considered to convert uranium metal to UO 2 and eliminate H 2 generation during final sludge disposition. Preliminary assessments of warm water oxidation have been conducted, and several issues have been identified that can best be evaluated through laboratory testing. The scoping evaluation documented here was specifically focused on the issue of the potential formation of high strength sludge agglomerates at the proposed 95°C process operating temperature. Prior hydrothermal tests conducted at 185°C produced significant physiochemical changes to genuine sludge, including the formation of monolithic concretions/agglomerates that exhibited shear strengths in excess of 100 kPa (Delegard et al. 2007).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector

The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Gas flow analysis during thermal vacuum test of a spacecraft

The self-contamination of the IMP-H spacecraft, while it was undergoing thermal and solar vacuum tests, has been investigated in conjunction with the outgassing evaluation and detection of molecular flow anomalies occurring in the test chamber. The pressures indicated by two tubulated ionization gauges were used to calculate flow kinetics in the vacuum chamber. The fluxes of emitted molecules and chamber wall reflected molecules were monitored during the entire test. Representative equations and graphs are presented. Test results indicate that from 3 to 9 of every 100 emitted molecules returned to the spacecraft surface; that self-contamination by noncondensable gases was more severe than that by condensable gases; and that outgassing of the spacecraft was approximately 1.18 x 0.01 g/s after 10 hours and 1.18 x 0.001 after 90 hours of vacuum exposure. Testing deficiencies have been identified, and the type and location of instruments required to measure the outgassing, the degree of contamination, and return flow are discussed.

Scialdone, J. J.↗