At least 487 records · Page 27

Preliminary analysis of FCM fuel thermal-mechanical performance under normal and transient conditions

Fully ceramic microencapsulated (FCM) fuel is a candidate fuel form to replace commercial UO{sub 2} fuel rod in LWR to enhance fuel reliability under accident conditions. The FCM pellet consists of TRISO particles embedded inside the dense SiC matrix. This fuel design is more complex than conventional LWR fuel, which needs new fuel performance models or analysis tools to assist fuel design and concept evaluation. In this paper an attempt was made to develop a finite element method to analyze FCM fuel pellet thermal-mechanical performance. Three idealized cases of normal operation, power ramp, and LOCA were analyzed. The results showed that the temperature distribution and stress distribution of FCM pellet exhibited a strong non-uniformity. The irradiation strain and creep of buffer layer and PyC (pyrolytic carbon) layers had a strong effect on the mechanical performance of FCM pellet. The hoop stresses of SiC layers and SiC matrix increased significantly during the LOCA and varied with radial positions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design, Analysis, Comparison, and Experimental Validation of Insulated Metal Substrates for High-Power Wide-Bandgap Power Modules

Direct bonded copper (DBC) substrates used in power modules have limited heat spreading and manufacturing capability due to ceramic properties and manufacturing technology. The ceramic and copper bonding is also subject to high mechanical stress due to coefficient of thermal expansion mismatch between the copper and the ceramic. For wide-bandgap (WBG) devices, it is of interest exploring new substrate technologies that can overcome some of the challenges of direct bonded copper substrates. In this technical paper, the design, analysis, and comparison of insulated metal substrates (IMSs) for high-power wide-bandgap semiconductor-based power modules are discussed. This paper starts with technical description and discussion of state-of-the-art DBC substrates with different ceramic insulators such as aluminum nitride (AlN), Al 2 O 3 , and Si 3 N 4 . Next, an introduction of IMSs and their material properties, and a design approach for SiC (silicon carbide) metal-oxide-semiconductor field-effect transistor (MOSFET)-based power modules for high-power applications is provided. The influence of dielectric thickness on the power handling capability of the substrate are also discussed. The designed IMS and DBC substrates were characterized in terms of steady-state and transient thermal performance using finite element simulation. Finally, the performance of the IMS and DBC are validated in an experimental setup under different loading and cooling temperature conditions. We report the simulation and experimental results showed that the IMS can provide high steady-state thermal performance for high-power modules based on SiC MOSFETs. Furthermore, the IMS provided enhanced transient thermal performance, which provided a reduced junction temperature when the module is operated at low fundamental output frequencies in traction drive systems.

42 ENGINEERING↗

Atmospheric Entry Studies for Venus Missions: 45 Sphere-Cone Rigid Aeroshells and Ballistic Entries

The present study considers direct ballistic entries into the atmosphere of Venus using a 45deg sphere-cone rigid aeroshell, a legacy shape that has been used successfully in the past in the Pioneer Venus Multiprobe Mission. For a number of entry mass and heatshield diameter combinations (i.e., various ballistic coefficients) and entry velocities, the trajectory space in terms of entry flight path angles between skip out and -30deg is explored with a 3DoF trajectory code, TRAJ. From these trajectories, the viable entry flight path angle space is determined through the use of mechanical and thermal performance limits on the thermal protection material and science payload; the thermal protection material of choice is entry-grade carbon phenolic, for which a material thermal response model is available. For mechanical performance, a 200 g limit is placed on the peak deceleration load experienced by the science instruments, and 10 bar is assumed as the pressure limit for entry-grade carbon-phenolic material. For thermal performance, inflection points in the total heat load distribution are used as cut off criteria. Analysis of the results shows the existence of a range of critical ballistic coefficients beyond which the steepest possible entries are determined by the pressure limit of the material rather than the deceleration load limit.

Prabhu, Dinesh K.↗

Development and Implementation of a Generic Analysis Template for Structural-Thermal-Optical-Performance Modeling

Performance-related effects of system level temperature changes can be a key consideration in the design of many types of optical instruments. This is especially true for space-based imagers, which may require complex thermal control systems to maintain alignment of the optical components. Structural-Thermal-Optical-Performance (STOP) analysis is a multi-disciplinary process that can be used to assess the performance of these optical systems when subjected to the expected design environment. This type of analysis can be very time consuming, which makes it difficult to use as a trade study tool early in the project life cycle. In many cases, only one or two iterations can be performed over the course of a project. This limits the design space to best practices since it may be too difficult, or take too long, to test new concepts analytically. In order to overcome this challenge, automation, and a standard procedure for performing these studies is essential. A methodology was developed within the framework of the Comet software tool that captures the basic inputs, outputs, and processes used in most STOP analyses. This resulted in a generic, reusable analysis template that can be used for design trades for a variety of optical systems. The template captures much of the upfront setup such as meshing, boundary conditions, data transfer, naming conventions, and post-processing, and therefore saves time for each subsequent project. A description of the methodology and the analysis template is presented, and results are described for a simple telescope optical system.

Scola, Salvatore↗

An Analytical Methodology to Evaluate Thermal-Hydraulic Performance of Compact Heat Exchangers, Accounting for Heat Loss

High efficiency and compactness, offered by the Printed Circuit Heat Exchanger (PCHE) makes it a strong candidate for use as an Intermediate Heat Exchanger (IHX) and/or Secondary Heat Exchanger (SHX) for Advanced High Temperature Reactor (AHTR) systems and also the Very High Temperature Reactor (VHTR). Idaho National Laboratory (INL) has been developing a computer code for the PCHE design and analysis [1], and will construct an experimental loop to evaluate the thermal hydraulic performance of PCHEs [2]. In order to correctly compare experimental results with the simulations, the extraneous heat losses from the PCHEs must be determined and incorporated. These heat exchangers operate at high temperature and consequently, despite the use of external thermal insulation, experience non-negligible heat losses to the surroundings. The objective of this work is to develop an analytical methodology for quantification of these heat losses based on experimental data to evaluate and predict the performance of the heat exchanger accurately.

99 GENERAL AND MISCELLANEOUS↗

Real-Time Inhibitor Recession Measurements in Two Space Shuttle Reusable Solid Rocket Motors

Real-time internal motor insulation char line recession measurements have been evaluated for two full-scale static tests of the Space Shuttle Reusable Solid Rocket Motor (RSRM). These char line recession measurements were recorded on the forward facing propellant grain inhibitors to better understand the thermal performance of these inhibitors. The RSRM propellant grain inhibitors are designed to erode away during motor operation, thus making it difficult to use post-fire observations to determine inhibitor thermal performance. Therefore, this new internal motor instrumentation is invaluable in establishing an accurate understanding of inhibitor recession versus motor operation time. The data for the first test was presented at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit (AIAA 2001-3280) in July 2001. Since that time, a second full scale static test has delivered additional real-time data on inhibitor thermal performance. The evaluation of this data is presented in this paper. The second static test, in contrast to the first test, used a slightly different arrangement of instrumentation in the inhibitors. This instrumentation has yielded a better understanding of the inhibitor time dependent inboard tip recession. Graphs of inhibitor recession profiles with time are presented. Inhibitor thermal ablation models have been created from theoretical principals. The model predictions compare favorably with data from both tests. This verified modeling effort is important to support new inhibitor designs for a five segment Space Shuttle solid rocket motor. The internal instrumentation project on RSRM static tests is providing unique opportunities for other real-time internal motor measurements that could not otherwise be directly quantified.

McWhorter, B. B.↗

Thermal-hydraulic performance of printed circuit heat exchangers: CFD analysis with experimental validation - 18434

Results of a computational fluid dynamic (CFD) study of flow and heat transfer in a printed circuit heat exchanger (PCHE) geometry are presented. CFD results obtained from a two-plate model are compared to corresponding experimental results for the validation. This process provides the basis for further application of the CFD code to PCHE design and performance analysis in a variety of internal flow geometries. As a part of the code verification and validation (V and V) process, CFD simulation of a single semicircular straight channel under laminar isothermal conditions was also performed and compared to theoretical results. This comparison yielded good agreement with the theoretical values. The two-plate CFD model based on the experimental PCHE design overestimated the effectiveness and underestimated the pressure drop. However, it is found that the discrepancy between the CFD result and experimental data was a result of the uncertainty in the geometry of heat exchanger during the fabrication. The CFD results obtained using a slightly smaller channel diameter yielded good agreement with the experimental data. A separate investigation revealed that the average channel diameter of the OSU PCHE after the diffusion-bonding was 1.93 mm on the cold fluid side and 1.90 mm on the hot fluid side which are both smaller than the nominal design value. Consequently, the CFD code was shown to have sufficient capability to evaluate the heat exchanger thermal-hydraulic performance. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Whole building retrofit using vacuum insulation panels and energy performance analysis

Vacuum insulation panels (VIPs), due to their high thermal performance, provide an attractive alternative to traditional building insulation materials, especially as an option for retrofitting old, poorly insulated buildings. This article describes the complete retrofit of all exterior walls of a single-story building in a cold climate using VIPs. A recently-developed low-cost VIP, called modified atmosphere insulation (MAI), was used in this study. Two buildings of near-identical construction were studied, with one remaining unaltered and serving as the baseline while the other served as the retrofit building. The VIPs or MAI panels proved to be a feasible and durable option for retrofitting building envelopes. Thermal performance of both buildings was analyzed using in-situ temperature and heat flow sensors. Numerical models of the two buildings were created, benchmarked using experimental data and used for predictions of annual energy savings due to the addition of MAI panels to the exterior walls. The models predicted significant reduction in the annual heating energy consumption in the retrofitted building compared to the baseline building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and validation of cryogenic foam insulation for LH2 subsonic transports

Fourteen foam insulation specimens were tested. Some were plain foam while others contained flame retardants, chopped fiberglass reinforcement and/or vapor barriers. The thermal performance of the insulation was determined by measuring the rate at which LH2 boiled from an aluminum tank insulated with the test material. The test specimens were approximately 50 mm (2 in.) thick. They were structurally scaled so that the test cycle would duplicate the maximum thermal stresses predicted for the thicker insulation of an aircraft liquid hydrogen fuel tank during a typical subsonic flight. The simulated flight cycle of approximately 10 minutes duration heated the other insulation surface to 316 K (110 F) and cooled it to 226 K (20 F) while the inner insulation surface remained at liquid hydrogen temperature of 20 K (-423 F). Two urethane foam insulations exceeded the initial life goal of 2400 simulated flight cycles and sustained 4400 cycles with only minor damage. The addition of fiberglass reinforcement of flame retardant materials to an insulation degraded thermal performance and/or the life of the foam material. Installation of vapor barriers enhanced the structural integrity of the material but did not improve thermal performance. All of the foams tested were available materials; none were developed specifically for LH2 service.

Anthony, F. M.↗

Battery Lifetime Analysis and Simulation Tool (BLAST) Documentation

The deployment and use of lithium-ion (Li-ion) batteries in automotive and stationary energy storage applications must be optimized to justify their high up-front costs. Given that batteries degrade with use and storage, such optimizations must evaluate many years of operation. As the degradation mechanisms are sensitive to temperature, state-of-charge (SOC) histories, current levels, and cycle depth and frequency, it is important to model both the battery and the application to a high level of detail to ensure battery response is accurately predicted. To address these issues, the National Renewable Energy Laboratory (NREL) has developed the Battery Lifetime Analysis and Simulation Tool (BLAST) suite. This suite of tools pairs NREL’s high-fidelity battery degradation model with a battery electrical and thermal performance model, application-specific electrical and thermal performance models of the larger system (e.g., an electric vehicle), application-specific system use data (e.g., vehicle travel patterns and driving data), and historic climate data from cities across the United States. This provides highly realistic long-term predictions of battery response and thereby enables quantitative comparisons of varied battery use strategies.

25 ENERGY STORAGE↗

Calibration of a calorimeter for measuring the performance of thermal control surfaces

The calibration to evaluate the heat leak in terms of the deviation from a perfect calorimeter is described. A thermal vacuum test was carried out to characterize the performance of the calorimeter. The calorimeter was equipped with a heater to control the sample disc temperature and with specific instrumentation to measure the heat leak. The radiation sink temperature of the black cavity target was varied from -192 to +31C, while the heater power was varied from 0 to 311 milliwatts. A steady state thermal model was developed to correlate the results. The calorimeter performance was characterized in terms of the heat leak as a percentage of the ideal heat flow of the calorimeter disc. Large deviations from ideal performance occur at low sink temperatures. The effect of the use of the heater is discussed. The effects of transient conditions during low Earth orbit are discussed. It is concluded that heat leak calibrations are necessary for a wide range of conditions.

Houseman, John↗

Degradation of a Multilayer Insulation Due to a Seam and a Penetration

The degradation of the thermal performance of a multilayer insulation due to the presence of a seam and a penetration was studied. The multilayer insulation had 30 aluminized Mylar radiation shields with silk net spacers. The seam, an offset butt joint, caused a heat input of 0.169 watt per meter in addition to the basic insulation thermal performance of 0.388 watt per square meter obtained before the installation of the butt joint. The penetration, a fiberglass tank support strut, provided a heat input (including the degradation of the insulation) of 0.543 watt in addition to the basic insulation thermal performance of 0.452 watt per square meter obtained before the penetration.

Sumner, I. E.↗

Evaluation of GLAS Demonstration Model Loop Heat Pipe Thermal Vacuum Performance with Various Fluid Charges

Two loop heat pipes (LHPs) are to be used for tight thermal control of the Geoscience Laser Altimeter System (GLAS) instrument, planned for flight in late 2001. The LHPs are charged with Propylene as a working fluid. One LHP will be used to transport 110 W from a laser a radiator, the other will transport 190 W from electronic boxes to a separate radiator. The application includes a large amount of thermal mass in each LHP system and low initial startup powers. This along with some non-ideal flight design compromises, such as a less than ideal charge level for this design concept with a symmetrical secondary wick, lead to inadequate performance of the flight LHPs during the flight thermal vacuum test in October of 2000. This presentation focuses on identifying; the sources of the flight test difficulties by modifying the charge and test setup of the successfully tested Development Model Loop Heat Pipe (DM LHP). While very similar to the flight design, the DM L14P did have several significant difference in design and method of testing. These differences were evaluated for affect on performance by conforming the DM LHP to look more like the flight units. The major difference that was evaluated was the relative fill level of the working fluid within the concentrically design LHP compensation chamber. Other differences were also assessed through performance testing including starter heater size and "hot biasing" of major interior components. Performance was assessed with respect to startup, low power operation, conductance, and control heater power. The results of the testing showed that performance improves as initial charge increases, and when the starter heater is made smaller. The "hot biasing" of the major components did not appear to have a detrimental effect. As a result of test results of the DM LHP, modifications are being made to the flight units to increase the fluid charge and increase the watt-density of the starter heater.

Baker, Charles↗

Performance of thermal adhesives in forced convection

Cooling is critical for the life and performance of electronic equipment. In most cases cooling may be achieved by natural convection but forced convection may be necessary for high wattage applications. Use of conventional type heat sinks may not be feasible from the viewpoint of specific applications and the costs involved. In a heat sink, fins can be attached to the well by ultrasonic welding, by soldering, or with a number of industrially available thermal adhesives. In this paper, the author investigates the heat transfer characteristics of several adhesives and compares them with ultrasonic welding and theoretically calculated values. This experiment was conducted in an air flow chamber. Heat was generated by using heaters mounted on the well. Thermstrate foil, Uniset A401, and Aremco 571 adhesives were tested along with an ultrasonically welded sample. Ultrasonic welding performed far better than the adhesives and Thermstrate foil. This type of experiment can be adapted for a laboratory exercise in an upper level heat transfer course. It gives students an exposure to industrial applications that help them appreciate the importance of the course material.

Kundu, Nikhil K.↗

Experimental investigation of plastic finned-tube heat exchangers, with emphasis on material thermal conductivity

In this paper, two modified types of polypropylene (PP) with high thermal conductivity up to 2.3 W/m K and 16.5 W/m K are used to manufacture the finned-tube heat exchangers, which are prospected to be used in liquid desiccant air conditioning, heat recovery, water source heat pump, sea water desalination, etc. A third plastic heat exchanger is also manufactured with ordinary PP for validation and comparison. Experiments are carried out to determine the thermal performance of the plastic heat exchangers. It is found that the plastic finned-tube heat exchanger with thermal conductivity of 16.5 W/m K can achieve overall heat transfer coefficient of 34 W/m{sup 2} K. The experimental results are compared with calculation and they agree well with each other. Finally, the effect of material thermal conductivity on heat exchanger thermal performance is studied in detail. The results show that there is a threshold value of material thermal conductivity. Below this value improving thermal conductivity can considerably improve the heat exchanger performance while over this value improving thermal conductivity contributes very little to performance enhancement. For the finned-tube heat exchanger designed in this paper, when the plastic thermal conductivity can reach over 15 W/m K, it can achieve more than 95% of the titanium heat exchanger performance and 84% of the aluminum or copper heat exchanger performance with the same dimension. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗