Power Surge Testing for Polymer Tantalum Capacitors

Due to dry environments, anomalous charging currents (ACC) in polymer tantalum capacitors (PTC) might cause malfunctions and failures in space systems. Currently, there is no standard metrics to assess this effect and factors affecting ACC are not well understood. This paper discusses benefits and drawbacks of different methods used to reveal ACC and suggest a power surge testing (PST) as a procedure for screening and qualification of PTCs. The suggested test is similar to the surge current testing that is currently used for MnO2 tantalum capacitors but assures dissipation of high power in the part during the whole period of testing. Using various types of capacitors, the reproducibility of test results for different lots of PTCs and from sample to sample in a lot were estimated. The impact of moisture content, test temperature, stress voltages, and preconditioning is assessed. Thermal effects associated with ACC and the possibility of catastrophic failures were studied experimentally using an IR camera and calculated at adiabatic heating conditions. Possible mechanisms of the phenomenon are discussed and recommendations for testing to avoid failures related to ACC are suggested.

Alexander A Teverovsky↗

Near Infrared In-situ Measurements for the Detection of Keyhole Porosity in Autogenous Ti-6AL-4V Welds

Certification of additive manufactured metal parts requires nondestructive evaluation (NDE) to ensure build quality. NDE can be performed during the build process or post build. For large parts with complex geometries, post build NDE can be challenging. In-situ NDE potentially provides a way to perform the inspection layer by layer. This work explores the use of a high speed near infrared (NIR) camera that is focused in-line with a laser to obtain high spatial and temporal resolution thermal imagery of the melt pool and associated cooling areas. The thermal data is obtained during a laser melting process using Ti-6AL-4V plate and of particular interest is the detection of keyhole porosity. Keyhole porosity can result from non-optimal build conditions, such as excessive laser power at a given laser scanning speed, that creates an entrapped bubble. The NIR measured melt pool and cooling areas are processed to detect keyhole porosity. The results are compared to X-ray CT results for validation.

additive manufacturing↗

Near Infrared In-situ Measurements for the Detection of Keyhole Porosity in Autogenous Ti-6AL-4V Welds

Certification of additive manufactured metal parts requires nondestructive evaluation (NDE) to ensure build quality. NDE can be performed during the build process or post build. For large parts with complex geometries, post build NDE can be challenging. In-situ NDE potentially provides a way to perform the inspection layer by layer. This work explores the use of a high speed near infrared (NIR) camera that is focused in-line with a laser to obtain high spatial and temporal resolution thermal imagery of the melt pool and associated cooling areas. The thermal data is obtained during a laser melting process using a Ti-6Al-4V plate and of particular interest is the detection of keyhole porosity. Keyhole porosity can result from non-optimal build conditions, such as excessive laser power at a given laser scanning speed, that creates an entrapped bubble. The NIR measured melt pool and cooling areas are processed to detect keyhole porosity. The results are compared to X-ray CT results for validation. Small keyhole pores buried deep were not detectable with this technique, however, some larger subsurface elongated pores along with some open surface pores did show some promise for detectability.

additive manufacturing↗

Assessment of the Mars Helicopter Thermal Design Sensitivities Using the Veritrek Software

The Mars Helicopter will be a technology demonstration conducted during the Mars 2020 mission. The primary mission objective is to achieve several 90-second flights and capture visible light images via forward and nadir mounted cameras. These flights could possibly provide reconnaissance data for sampling site selection for other Mars surface missions. The helicopter is powered by a solar array, which stores energy in secondary batteries for flight operations, imaging, communications, and survival heating. The helicopter thermal design is driven by minimizing survival heater energy while maintaining compliance with allowable flight temperatures in a variable thermal environment. Due to the small size of the helicopter and its complex geometries, along with the fact that it operates with very low power and small margins, additional care had to be paid while planning thermal tests and designing the thermal system. A Thermal Desktop® model has been developed to predict the thermal system’s performance. A reduced-order model (ROM) created with the Veritrek software has been utilized to explore the sensitivities of the thermal system’s drivers, such as electronics dissipations, gas gaps, heat transfer coefficients, etc., as well as to assess and verify the final thermal design. This paper presents the performance of the Veritrek software products and the details of the ROM creation process. The results produced by Veritrek were utilized to study the effect of the major thermal design drivers and Mars environment on the Mars Helicopter in as little as 10 days, an effort that would have taken over 4 months using traditional thermal analysis techniques.

Hengeveld, Derek W.↗

90 GHz and 150 GHz Observations of the Orion M42 Region. A Submillimeter to Radio Analysis

We have used the new 90GHz MUSTANG camera on the Robert C. Green Bank Telescope (GBT)to map the bright Huygens region of the star-forming region M42 with a resolution of 9" and a sensitivity of 2.8 mJy/beam. Ninety GHz is an interesting transition frequency, as MUSTANG detects both the free-free emission characteristic of the H II region created by the Trapezium stars, normally seen at lower frequencies, and thermal dust emission from the background OMCI molecular cloud, normally mapped at higher frequencies. We also present similar data from the 150 GHz GISMO camera taken on the IRAM 30 m telescope. This map has 15" resolution. By combining the MUSTANG data with 1.4, 8. and 31 GHz radio data from the VLA and GBT, we derive a new estimate of the emission measure averaged electron temperature of T(sub e) = 11376+/-1050 K by an original method relating free-free emission intensities at optically thin and optically thick frequencies. Combining Infrared Space Observatory-long wavelength spectrometer (ISO-LWS) data with our data, we derive a new estimate of the dust temperature and spectral emissivity index within the 80" ISO-LWS beam toward Orion KL/BN, T(sub d) = 42+/-3 K and Beta(sub d) = 1.3+/-0.1. We show that both T(sub d) and Beta(sub d) decrease when going from the H II region and excited OMCI interface to the denser UV shielded part OMCI (Orion KL/BN, Orion S). With a model consisting of only free-free and thermal dust emission, we are able to fit data taken at frequencies from 1.5 GHz to 854 GHz (350 micrometers).

Dicker, S. R.↗

Image Quality Indicator for Infrared Inspections

The quality of images generated during an infrared thermal inspection depends on many system variables, settings, and parameters to include the focal length setting of the IR camera lens. If any relevant parameter is incorrect or sub-optimal, the resulting IR images will usually exhibit inherent unsharpness and lack of resolution. Traditional reference standards and image quality indicators (IQIs) are made of representative hardware samples and contain representative flaws of concern. These standards are used to verify that representative flaws can be detected with the current IR system settings. However, these traditional standards do not enable the operator to quantify the quality limitations of the resulting images, i.e. determine the inherent maximum image sensitivity and image resolution. As a result, the operator does not have the ability to optimize the IR inspection system prior to data acquisition. The innovative IQI described here eliminates this limitation and enables the operator to objectively quantify and optimize the relevant variables of the IR inspection system, resulting in enhanced image quality with consistency and repeatability in the inspection application. The IR IQI consists of various copper foil features of known sizes that are printed on a dielectric non-conductive board. The significant difference in thermal conductivity between the two materials ensures that each appears with a distinct grayscale or brightness in the resulting IR image. Therefore, the IR image of the IQI exhibits high contrast between the copper features and the underlying dielectric board, which is required to detect the edges of the various copper features. The copper features consist of individual elements of various shapes and sizes, or of element-pairs of known shapes and sizes and with known spacing between the elements creating the pair. For example, filled copper circles with various diameters can be used as individual elements to quantify the image sensitivity limit. Copper line-pairs of various sizes where the line width is equivalent to the spacing between the lines can be used as element-pairs to quantify the image resolution limit.

Burke, Eric↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver

High-temperature particle receivers are being pursued to enable next-generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 °C) to enable more efficient power cycles, lower overall system costs, and emerging CSP-based process-heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera- based imaging methods were developed and applied to both laboratory-scale and larger 1 MW t on-sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle-sampling methods using volumetric particle-air samplers were applied to the on-sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3-D printed tipping buckets and tethered balloons were also developed and applied to the on-sun particle-receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera-based imaging methods correlated well with measured values during the on-sun tests.

14 SOLAR ENERGY↗

THERMAL EMISSION AND TIDAL HEATING OF THE HEAVY AND ECCENTRIC PLANET XO-3b

We determined the flux ratios of the heavy and eccentric planet XO-3b to its parent star in the four Infrared Array Camera bands of the Spitzer Space Telescope: 0.101% +- 0.004% at 3.6 {mu}m; 0.143% +- 0.006% at 4.5 {mu}m; 0.134% +- 0.049% at 5.8 {mu}m; and 0.150% +- 0.036% at 8.0 {mu}m. The flux ratios are within [-2.2, 0.3, -0.8, and -1.7]sigma of the model of XO-3b with a thermally inverted stratosphere in the 3.6 {mu}m, 4.5 {mu}m, 5.8 {mu}m, and 8.0 {mu}m channels, respectively. XO-3b has a high illumination from its parent star (F{sub p} {approx} (1.9-4.2) x 10{sup 9} erg cm{sup -2} s{sup -1}) and is thus expected to have a thermal inversion, which we indeed observe. When combined with existing data for other planets, the correlation between the presence of an atmospheric temperature inversion and the substellar flux is insufficient to explain why some high insolation planets like TrES-3 do not have stratospheric inversions and some low insolation planets like XO-1b do have inversions. Secondary factors such as sulfur chemistry, atmospheric metallicity, amounts of macroscopic mixing in the stratosphere, or even dynamical weather effects likely play a role. Using the secondary eclipse timing centroids, we determined the orbital eccentricity of XO-3b as e = 0.277 +- 0.009. The model radius-age trajectories for XO-3b imply that at least some amount of tidal heating is required to inflate the radius of XO-3b, and the tidal heating parameter of the planet is constrained to Q{sub p} {approx}< 10{sup 6}.

79 ASTRONOMY AND ASTROPHYSICS↗

Phyllosilicate Decomposition on Bennu Due to Prolonged Surface Exposure

The Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission to carbonaceous asteroid (101955) Bennu performed detailed mapping with a suite of instruments to characterize the composition and geology of its surface. Here we use data from the OSIRIS-REx Thermal Emission Spectrometer (OTES) instrument to investigate the relationship of OTES-derived spectral indices to other derived data products from OTES, the OSIRIS-REx Camera Suite (OCAMS), and the OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS) at global and local scales. We quantitatively confirm that high values of the OTES silicate stretching slope (from ∼10 to ∼12 μm) in midday spectra that are indicative of thin and/or patchy dust cover are strongly associated with low thermal inertia (high porosity), low albedo boulders on Bennu. These high porosity boulders have brecciated textures with embedded clasts that likely originated on Bennu's parent body or during its disruption. The high porosity of these boulders is a key factor in the local production of the dust or its entrapment, as some large, brecciated boulders with a lower porosity have little evidence of dust. A second OTES spectral parameter, the silicate bending band depth near 22.7 μm applied to early evening spectra, is not correlated to thermal inertia, but is weakly to strongly correlated to albedo, OVIRS-derived 1.05 μm and 2.74 μm band depths, OVIRS-derived hydrogen abundance, and modeled nanophase troilite abundance. In several regions on Bennu there is a strong spatial relationship between these parameters, whereby areas with shallower silicate bending bands also have shallower 1.05 μm and 2.74 μm bands and lower albedo with higher nanophase troilite abundances. These correlations, combined with analysis of the silicate bending band in laboratory experiments of space weathered and mildly heated carbonaceous chondrites, suggests that decreased silicate bending band depths signify decomposition of phyllosilicates, likely Fe-bearing, due to space weathering or mild heating (<600 °C) via solar radiation during Bennu's time in near-Earth space. There is a strong association of larger silicate bending band depths in areas dominated by small rocks and unresolved material and in areas with small (≤ 25 m) craters identified as the spectrally reddest on Bennu, suggesting that this material has been more recently exposed due to impact and/or mass wasting processes. The shallowest silicate bending depths are associated with larger rocks and boulders that appear to have the longest surface exposure history, although there is band depth variation among them suggesting either initial composition variation that resulted in different responses to space weathering or heating, or varied exposure history of individual boulders themselves. We predict that any grains returned from Bennu with a significant surface exposure history will be characterized by shallower 22.7 μm, 1.05 μm and 2.7 μm band depths and increased sulfide (troilite) abundance, as well as textural and chemical evidence for phyllosilicate dehydration.

Asteroids, surfaces↗

Characteristics of the 2012 Geminids

The parent of the Geminids, 3200 Phaethon, is a unique body in that it is classified as an asteroid, however is responsible for one of the most prolific meteor showers of the year and has shown comet-like behavior in its past (Jewitt and Li 2010). The Geminid meteor shower is also anomalous as its rates have been increasing since it was first detected. Understanding the composition and properties of meteoroids that belong to this meteor shower is an important area of study and of interest to both theoreticians and experimentalists. Using the light curve and decelerations of ten double-station Geminids as seen in the Meteoroid Environment Office's widefield meteor cameras, densities were able to be approximated using a model of meteoroid ablation by Campbell-Brown et al (2013) which employs thermal disruption to model the release of grains during ablation. Bulk densities of Geminids give unique insight into the composition of Phaethon that would only be derived by going to the asteroid itself. The bulk densities of these ten Geminids were found to be between 2.6 and 3.0 g/cm(3), supporting results from Babadzhanov (2009) and Borovicka et al (2010) which prove Phaethon has a much lower porosity than most other meteor shower parents. NASA's Meteoroid Environment Office established these two wide-field meteor cameras to observe meteors in the milligram-mass-range. Each camera consists of a 17 mm focal length Schneider lens (f/0.95) on a Watec 902U2 Ultimate CCD video camera, producing a 21.7x15.5 degree field-of-view. This configuration sees meteors down to a magnitude of +6. Data from these cameras are currently being used to calculate daily automated meteor fluxes. On the first night of operation, December 13-14, 2012, 18 double-station and 53 unique single-station Geminids were detected. The Geminid flux results from this system will be presented as well as ZHR's over the peak of the Geminids. The average flux density over the night was 0.058, 0.052, and 0.062 meteors/km(2)/hour down to a limiting magnitude of +6.5, for the double-station results and each single-station's results. This equates to ZHR's of 113, 102, and 122 respectively. Included in the flux algorithm is a process to find the collecting area per height and a method to find the limiting meteor magnitude per 10 minute time period.

Blaauw, R.↗

NEAR-INFRARED THERMAL EMISSION FROM WASP-12b: DETECTIONS OF THE SECONDARY ECLIPSE IN Ks, H, AND J

We present Ks, H, and J-band photometry of the very highly irradiated hot Jupiter WASP-12b using the Wide-field Infrared Camera on the Canada-France-Hawaii telescope. Our photometry brackets the secondary eclipse of WASP-12b in the Ks and H bands, and in J band starts in mid-eclipse and continues until well after the end of the eclipse. We detect its thermal emission in all three near-infrared bands. Our secondary eclipse depths are 0.309{sup +0.013}{sub -0.012}% in Ks band (24{sigma}), 0.176{sup +0.016}{sub -0.021}% in H band (9{sigma}), and 0.131{sup +0.027}{sub -0.029}% in J band (4{sigma}). All three secondary eclipses are best fit with a consistent phase, {phi}, that is compatible with a circular orbit: {phi} = 0.4998{sup +0.0008}{sub -0.0007}. The limits on the eccentricity, e, and argument of periastron, {omega}, of this planet from our photometry alone are thus |ecos {omega}| < 0.0040. By combining our secondary eclipse times with others published in the literature, as well as the radial-velocity and transit-timing data for this system, we show that there is no evidence that WASP-12b is precessing at a detectable rate and that its orbital eccentricity is likely zero. Our thermal-emission measurements also allow us to constrain the characteristics of the planet's atmosphere; our Ks-band eclipse depth argues strongly in favor of inefficient day to nightside redistribution of heat and a low Bond albedo for this very highly irradiated hot Jupiter. The J- and H-band brightness temperatures are slightly cooler than the Ks-band brightness temperature, and thus hint at the possibility of a modest temperature inversion deep in the atmosphere of WASP-12b; the high-pressure, deep atmospheric layers probed by our J- and H-band observations are likely more homogenized than the higher altitude layer probed by our Ks-band observations. Lastly, our best-fit Ks-band eclipse has a marginally longer duration than would otherwise be expected; this may be tentative evidence for material being tidally stripped from the planet-as was predicted for this system by Li and collaborators, and for which observational confirmation was recently arguably provided by Fossati and collaborators.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal behavior of single-crystal scintillators for high-speed X-ray imaging

Indirect detection of X-rays using single-crystal scintillators is a common approach for high-resolution X-ray imaging. With the high X-ray flux available from synchrotron sources and recent advances in high-speed visible-light cameras, these measurements are increasingly used to obtain time-resolved images of dynamic phenomena. The X-ray flux on the scintillator must, in many cases, be limited to avoid thermal damage and failure of the scintillator, which in turn limits the obtainable light levels from the scintillator. In this study, a transient one-dimensional numerical simulation of the temperature and stresses within three common scintillator crystals (YAG, LuAG and LSO) used for high-speed X-ray imaging is presented. Various conditions of thermal loading and convective cooling are also presented.

36 MATERIALS SCIENCE↗

Infrared and Reflected Solar Radiation Measurements from the TIROS 2 Meteorological Satellite

TIROS II contains instrumentation for measuring infrared and reflected solar radiation from the earth and its atmosphere. A medium resolution scanning radiometer and a low resolution non-scanning radiometer are employed. The satellite's spin provides the scan line of the medium resolution radiometer which is then advanced by the orbital motion. The spatial resolution is about 40 miles square when the earth directly beneath the satellite is viewed. The five channels employ bolometer detectors and filters to limit the spectral responses to five bands: 6 to 6.5 microns, 8 to 12 microns, 0.2 to 6 microns, 8 to 30 microns, and 0.55 to 0.75 microns. These five bands study, respectively: radiation in the water vapor absorption band; day and nighttime cloud cover; albedo; thermal radiation; and visual maps for comparison with satellite vidicon pictures. The low resolution non-scanning radiometer measures the earth's black-body temperature and albedo. Its field when viewing directly below is a circle of 450 miles diameter, covering part of each frame from the wide-field television camera. This radiometer consists of two thermistors, each in the apex of a reflective cone which provides optical gain. One thermistor is black and responds to both thermal and reflected solar radiation. The second responds to thermal but reflects solar radiation. The design, calibration, performance, and data reduction for both systems are discussed herein.

Bandeen, W. R.↗

SPATIALLY RESOLVED M-BAND EMISSION FROM IO’S LOKI PATERA–FIZEAU IMAGING AT THE 22.8 m LBT

The Large Binocular Telescope Interferometer mid-infrared camera, LMIRcam, imaged Io on the night of 2013 December 24 UT and detected strong M-band (4.8 μm) thermal emission arising from Loki Patera. The 22.8 m baseline of the Large Binocular Telescope provides an angular resolution of ∼32 mas (∼100 km at Io) resolving the Loki Patera emission into two distinct maxima originating from different regions within Loki’s horseshoe lava lake. This observation is consistent with the presence of a high-temperature source observed in previous studies combined with an independent peak arising from cooling crust from recent resurfacing. The deconvolved images also reveal 15 other emission sites on the visible hemisphere of Io including two previously unidentified hot spots.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal system and environmental testing of the Mars Helicopter

The Mars Helicopter will be a technology demonstration conducted during the Mars 2020 mission. The primary mission objective is to achieve several 90-second flights demonstrating the feasibility of heavier than air flight on Mars and capture visible light images via forward and nadir mounted cameras. These flights could possibly provide reconnaissance data for sampling site selection for other Mars surface missions. A solar array and batteries for flight operations, imaging, communications, and survival heating power the Helicopter. The thermal design is driven by minimizing survival heater energy while maintaining compliance with allowable flight temperatures in a variable thermal environment. Due to the small size of the Helicopter and its complex geometries, along with the fact that it operates with very low power and small margins in the extreme Mars environment, additional care had to be paid while planning thermal tests and designing the thermal system. The first section of the paper describes the evolution of the thermal system of the Mars Helicopter. After the first thermal vacuum test of the engineering model, the thermal team has conducted a partial effect analysis on the thermal design components that had a major impact on the system performance. Several design choices derived by analysis and test have been made to meet the energy allocation and the temperature requirements. These changes included increased gas gaps to reduce gas conduction, low emissivity coatings for internal components, blanket implementation, optimization of wire routing and fine-tuning of surface operations to optimize waste heat recovery. The second part of the paper describes the flight model thermal vacuum test and the subsequent thermal model correlation necessary to confirm the fidelity of the analysis results.

Pauken, Michael↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Water Ice Albedo Variations on the Martian Northern Polar Cap

The Viking Orbiters determined that the surface of Mars northern residual cap is water ice. Many researchers have related observed atmospheric water vapor abundances to seasonal exchange between reservoirs such as the polar caps, but the extent to which the exchange between the surface and the atmosphere remains uncertain. Early studies of the ice coverage and albedo of the northern residual Martian polar cap using Mariner 9 and Viking images reported that there were substantial internannual differences in ice deposition on the polar cap, a result which suggested a highly variable Martian climate. However, some of the data used in these studies were obtained at differing values of heliocentric solar longitude (L(sub s)). Reevaluation of this dataset indicated that the residual cap undergoes seasonal brightening throughout the summer, and indicated that this process repeats from year to year. In this study we continue to compare Mariner 9 and Viking Orbiter imaging observations and thermal data of the north residual polar cap to data acquired with Mars Global Surveyor s Mars Orbiter Camera (MOC) instrument. In the current study, our goal is to examine all released data from MGS MOC in the northern summer season, along with applicable TES data in order to better understand the albedo variations in the northern summer and their implications on water transport. To date, work has focused primarily on the MOC dataset. In 1999, data acquisition of the northern polar regions began at L(sub s) = 107, although there was little north polar data acquired from L(sub s)= 107 to L(sub s) = 109. We examined a total of 409 images from L(sub s) = 107 to L(sub s)=148. We have also examined data from 2000 from L(sub s)= 93 to L(sub s)= 110; additional progress is ongoing. Here we present a progress report of our observations, and continue to determine their implications for the Martian water cycle.

Hale, A. S.↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗