Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test system test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Coherency-Constrained Spectral Clustering for Power Network Reduction

This paper presents a methodology for reducing the complexity of large-scale power network models using spectral clustering, aggregation of electrical components, and cost function approximation. Two approaches are explored using unconstrained and constrained spectral clustering to determine areas for effective system reduction. Once the system areas are determined, both loads and generators by type are aggregated, and their new cost function is approximated through polynomial curve-fitting or statistical methods. The performance of reduced networks is evaluated in terms of their ability to follow the true daily cost of the original system over a 24-hour period considering a set of several days. Two test systems are taken as test beds. Application of the methodology to a modified version of the IEEE 39-bus system reduces it from 17 generators to a 4-bus system and 9 generators with about 93% of accuracy. Similarly, the IEEE 118-bus system is reduced from 19 generators to a 3-bus system with three aggregated units achieving over 99% of accuracy. These findings address scalability challenges and enhance accuracy for high and mid-loading level conditions, and by aggregating thermal units with similar cost functions.

42 ENGINEERING↗

A Metric-Based Validation Process to Assess the Realism of Synthetic Power Grids

Public power system test cases that are of high quality benefit the power systems research community with expanded resources for testing, demonstrating, and cross-validating new innovations. Building synthetic grid models for this purpose is a relatively new problem, for which a challenge is to show that created cases are sufficiently realistic. This paper puts forth a validation process based on a set of metrics observed from actual power system cases. These metrics follow the structure, proportions, and parameters of key power system elements, which can be used in assessing and validating the quality of synthetic power grids. Though wide diversity exists in the characteristics of power systems, the paper focuses on an initial set of common quantitative metrics to capture the distribution of typical values from real power systems. The process is applied to two new public test cases, which are shown to meet the criteria specified in the metrics of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SystemBurn: Principles of Design and Operation, Release 2.0

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

SystemBurn: Principles of Design and Operation Release 2.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

SystemBurn: Principles of Design and Operation Release 3.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

Benchmark↗

Sampling Point Compliance Tests for 325 Building at Set-Back Flow Conditions

The stack sampling system at the 325 Building (Radiochemical Processing Laboratory [RPL]) was constructed to comply with the American National Standards Institute’s (ANSI’s) Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities (ANSI N13.1-1969). This standard provided prescriptive criteria for the location of radionuclide air-sampling systems. In 1999, the standard was revised (Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities [ANSI/Health Physics Society [HPS] 13.1-1999]) to provide performance-based criteria for the location of sampling systems. Testing was conducted for the 325 Building stack to determine whether the sampling system would meet the updated criteria for uniform air velocity and contaminant concentration in the revised ANSI/HPS 13.1-1999 standard under normal operating conditions (Smith et al. 2010). Measurement results were within criteria for all tests. Additional testing and modeling was performed to determine whether the sampling system would meet criteria under set-back flow conditions. This included measurements taken from a scale model with one-third of the exhaust flow and computer modeling of the system with two-thirds of the exhaust flow. This report documents the results of the set-back flow condition measurements and modeling. Tests performed included flow angularity, uniformity of velocity, gas concentration, and particle concentration across the duct at the sampling location. Results are within ANSI/HPS 13.1-1999 criteria for all tests. These tests are applicable for the 325 Building stack under set-back exhaust flow operating conditions (980 - 45,400 cubic feet per minute [cfm]) with one fan running. The modeling results show that criteria are met for all tests using a two-fan configuration exhaust (flow modeled at 104,000 cfm). Combined with the results from the earlier normal operating conditions, the ANSI/HPS 13.1-1999 criteria for all tests are met for all configurations: one, two, or three fans (normal).

air sampling↗

FY2014 Vehicle and Systems Simulation and Testing Annual Progress Report

The Vehicle and Systems Simulation and Testing research and development (R&D) subprogram within the DOE Vehicle Technologies Office (VTO) provides support and guidance for many cutting-edge automotive technologies under development. Research focuses on addressing critical barriers to advancing light-, medium-, and heavy-duty vehicle systems to help maximize the number of electric miles driven and increase the energy efficiency of transportation vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Solid Oxide Fuel Cells Operating on Alternative and Renewable Fuels

This DOE project at the Pennsylvania State University (Penn State) initially involved Siemens Energy, Inc. to (1) develop new fuel processing approaches for using selected alternative and renewable fuels – anaerobic digester gas (ADG) and commercial diesel fuel (with 15 ppm sulfur) – in solid oxide fuel cell (SOFC) power generation systems; and (2) conduct integrated fuel processor – SOFC system tests to evaluate the performance of the fuel processors and overall systems. Siemens Energy Inc. was to provide SOFC system to Penn State for testing. The Siemens work was carried out at Siemens Energy Inc. in Pittsburgh, PA. The unexpected restructuring in Siemens organization, however, led to the elimination of the Siemens Stationary Fuel Cell Division within the company. Unfortunately, this led to the Siemens subcontract with Penn State ending on September 23rd, 2010. SOFC system was never delivered to Penn State. With the assistance of NETL project manager, the Penn State team has since developed a collaborative research with Delphi as the new subcontractor and this work involved the testing of a stack of planar solid oxide fuel cells from Delphi.

30 DIRECT ENERGY CONVERSION↗

FY25 Ion Exchange Processing for the West Area Risk Management (WARM) Project

The West Area Risk Management (WARM) Project was established to enable near-term retrieval and pretreatment of tank waste from Hanford’s 200 West Area and to support deployment of an ion exchange (IX) system capable of producing cesium-depleted supernate suitable for offsite treatment and disposal. The WARM experimental campaign was designed to provide key data for design and operational planning of the 200 W IX system, which plans to utilize crystalline silicotitanate (CST) as the active media for cesium removal. This report documents a comprehensive FY25 experimental campaign designed to produce key technical data required for design and operational planning of the WARM IX system. Testing includes assessing Cs and Sr breakthrough performance in a 4-column system, Cs capacity batch contact testing, phosphate precipitation assessments, reduced-hydroxide feed displacement evaluation, and Sr speciation impacts on Sr removal. The experimental results provide detailed trends in Cs and Sr loading behavior, breakthrough performance across a 4-column staged IX system, distribution profiles within CST beds, and projections of operational flowrates relative to Waste Acceptance Criteria (WAC) limits. Batch contact testing established equilibrium partitioning behavior for the S1–S5 simulants and characterized how matrix chemistry influenced Cs sorption onto CST. Additionally, further evaluations on waste matrix as it pertains to precipitation potential were also determined. Collectively, these datasets support engineering design choices for WARM system throughput and pretreatment planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ADMS Test Bed: Use Case 2

This presentation provides an overview of the National Renewable Energy Laboratory's advanced distribution management system test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ADMS Test Bed: Use Case 1

This presentation provides an overview of the National Renewable Energy Laboratory's advanced distribution management system test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ExINP-ENA Ice-Nucleating Particle Concentrations - CRAFT

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the U.S. Department of Energy's Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) observatory on Graciosa Island, Azores (39.0916° N, 28.0257° W). Our INP data were generated using a combination of online instruments, the Portable Ice Nucleation Experiment chamber (PINE), and an offline assay instrument, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT), for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores).

47-mm Nuclepore filter sampler, West Texas Cryogen↗

Physics-informed graphical neural network for power system state estimation

State estimation is highly critical for accurately observing the dynamic behavior of the power grids and minimizing risks from cyber threats. However, existing state estimation methods encounter challenges in accurately capturing power system dynamics, primarily because of limitations in encoding the grid topology and sparse measurements. Here, this paper proposes a physics-informed graphical learning state estimation method to address these limitations by leveraging both domain physical knowledge and a graph neural network (GNN). We employ a GNN architecture that can handle the graph-structured data of power systems more effectively than traditional data-driven methods. The physics-based knowledge is constructed from the branch current formulation, making the approach adaptable to both transmission and distribution systems. The validation results of three IEEE test systems show that the proposed method can achieve lower mean square error more than 20% than the conventional methods.

43 PARTICLE ACCELERATORS↗

Melting Hanford LAW into Iron-Phosphate Glass in a CCIM

A vitrification test has been conducted using the cold crucible induction melter (CCIM) test system at the Idaho National Laboratory. The test was conducted to demonstrate the vitrification of a Hanford low activity waste (LAW) that contains relatively large amounts of sulfate and sodium, compared to other radioactive Hanford waste streams. The high sulfate content limits the potential loading of this waste stream in conventional borosilicate glass, so this test demonstrated how this waste stream could be vitrified in an iron-phosphate glass that can tolerate higher levels of sulfate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards AI Based Data Classification for Decision Making During Testing

During the development of high-consequence items, test systems should be capable of differentiating between test failures resulting from narrowly missing requirements versus those indicating potentially catastrophic faults. In many instances, classifying the data corresponds to simply identifying whether measured waveforms have approximately the anticipated shape. Cast in this light, the problem reduces to converting raw data into a form optimal for use with neural network classifiers. This manuscript investigates different means of representing raw data for image classification. Raw data plots and Short Time Fourier Transform (STFT) spectrograms are classified by both custom built, small-scale, Convolution Neural Networks (CNN) and open-source, multi-million parameter, pre-trained deep CNNs. In the case of time varying frequency content, the STFTs provide images with greater detail and can be accurately classified with simpler networks. This requires less memory and runs faster than classifying the raw data using the more sophisticated options—making STFTs optimal for applications with memory constraints. STFTs are not a panacea. In some cases the time-domain signal contains useful information that should not be discarded. Rather than using raw data or STFTs, the images can be constructed from both by using red and green channels of an RGB image to visualize the real and imaginary components of the transform, with the raw data occupying the blue channel.

97 MATHEMATICS AND COMPUTING↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultra-sensitive Magnetic Microscopy with an Atomic Magnetometer

The PowerPoint presentation focused on research goals, specific information about the atomic magnetometer, response and resolution factors of the SERF magnetometer, FC+AM systems, tests of field transfer and resolution on FC, gradient cancellation, testing of AM performance, ideas for a multi-channel AM, including preliminary sensitivity testing, and a description of a 6 channel DAQ system. A few ideas for future work ended the presentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MIT reactor (MITR) driven subcritical facility for the fluoride-salt-cooled high-temperature reactor (FHR) - 18623

The Fluoride-salt-cooled High temperature Reactor (FHR) uses clean salt coolants, carbon-matrix coated-particle fuel similar to that used in High-temperature Gas-cooled Reactors (HTGRs) and can be coupled to a Nuclear Air-Brayton Combined Cycle (NACC). Recent assessments indicate favorable economics and safety characteristics, but no FHR has been built. The question is what experimental facilities should be constructed to reduce technical uncertainties before a decision to build a test/demonstration reactor? The MIT Reactor (MITR) design and license would allow the construction and operation of a subcritical facility with 700 deg. C salt circulating through multiple full-width partial-height fuel assemblies operating with a power density up to 30% of a commercial FHR. This option would allow hot systems testing as a major step toward building the test/demonstration reactor. Preliminary system design, power control options, testing capabilities, and key nuclear characteristics of such a reactor-driven subcritical facility are described. A method of deriving subcritical multiplicity using surface source has been proposed and verified in this study. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗