Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

CFD-Enhanced Calibration of a Multihole Probe for Small Uncrewed Aircraft Systems

A robust calibration method with a 9-hole probe (9HP) for inertial wind vector measurements from a small uncrewed aircraft system (sUAS) is presented. Calibration accuracy is improved by using computational fluid dynamics (CFD) to estimate corrections, such as those for test section blockage, that are generally applied in wind tunnel testing. A method for estimating experimental bias is presented to account for flow variations over the pressure taps as the 9HP is repositioned in the test section. Installation effects from flow over the airframe and upwash produced by the wings are estimated from CFD simulations of the entire airframe at the expected cruise speed. An initial CFD analysis has demonstrated a quantifiable linear relationship between the measured and actual angle of attack as measured from the relative wind frame. In conclusion, the objective of these additional steps is to increase the accuracy of 9HP calibration.

54 ENVIRONMENTAL SCIENCES↗

A convenient technique for polarimetric calibration of single-antenna radar systems

A practical technique for calibrating single-antenna polarimetric radar systems is introduced. This technique requires only a single calibration target such as a conducting sphere or a trihedral corner reflector to calibrate the radar system, both in amplitude and phase, for all linear polarization configurations. By using a metal sphere, which is orientation independent, error in calibration measurement is minimized while simultaneously calibrating the crosspolarization channels. The antenna system and two orthogonal channels (in free space) are modeled as a four-port passive network. Upon using the reciprocity relations for the passive network and assuming the crosscoupling terms of the antenna to be equal, the crosstalk factors of the antenna system and the transmit and receive channel imbalances can be obtained from measurement of the backscatter from a metal sphere. For an X-band radar system with crosspolarization isolation of 25 dB, comparison of values measured for a sphere and a cylinder with theoretical values shows agreement within 0.4 dB in magnitude and 5 deg in phase. An effective polarization isolation of 50 dB is achieved using this calibration technique.

Sarabandi, Kamal↗

Method of calibrating a fluid-level measurement system

A method of calibrating a fluid-level measurement system is provided. A first response of the system is recorded when the system's sensor(s) is (are) not in contact with a fluid of interest. A second response of the system is recorded when the system's sensor(s) is (are) fully immersed in the fluid of interest. Using the first and second responses, a plurality of expected responses of the system's sensor(s) is (are) generated for a corresponding plurality of levels of immersion of the sensor(s) in the fluid of interest.

Woodard, Stanley E.↗

Calibration of polarimetric radar systems with good polarization isolation

A practical technique is proposed for calibrating single-antenna polarimetric radar systems using a metal sphere plus any second target with a strong cross-polarized radar cross section. This technique assumes perfect isolation between antenna ports. It is shown that all magnitudes and phases (relative to one of the like-polarized linear polarization configurations) of the radar transfer function can be calibrated without knowledge of the scattering matrix of the second target. Comparison of the values measured (using this calibration technique) for a tilted cylinder at X-band with theoretical values shows agreement within + or - 0.3 dB in magnitude and + or - 5 degrees in phase. The radar overall cross-polarization isolation was 25 dB. The technique is particularly useful for calibrating a radar under field conditions, because it does not require the careful alignment of calibration targets.

Sarabandi, Kamal↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, Michael P.↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, M. P.↗

Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

visible spectrometers↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion and a mobile body portion. The mobile body portion is configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the microwave radiometer therein such that the microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion. In an embodiment, the mobile body portion includes a plurality of body section, each body section being configured for supporting a microwave radiometer therein. In another embodiment, each one of the plurality of body sections is configured to be interchangeably coupled with each other.

47 OTHER INSTRUMENTATION↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion, the fixed body portion being configured to attach to a mobile platform, and a mobile body portion, the mobile body portion being configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the at least one microwave radiometer therein such that the at least one microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the at least one radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion such that the at least one microwave radiometer provides a vertical scanning below and above the mobile platform.

Klein, Marian↗

Robot tracking system improvements and visual calibration of orbiter position for radiator inspection

The following separate topics are addressed: (1) improving a robotic tracking system; and (2) providing insights into orbiter position calibration for radiator inspection. The objective of the tracking system project was to provide the capability to track moving targets more accurately by adjusting parameters in the control system and implementing a predictive algorithm. A computer model was developed to emulate the tracking system. Using this model as a test bed, a self-tuning algorithm was developed to tune the system gains. The model yielded important findings concerning factors that affect the gains. The self-tuning algorithms will provide the concepts to write a program to automatically tune the gains in the real system. The section concerning orbiter position calibration provides a comparison to previous work that had been performed for plant growth. It provided the conceptualized routines required to visually determine the orbiter position and orientation. Furthermore, it identified the types of information which are required to flow between the robot controller and the vision system.

Tonkay, Gregory↗

Development of Multi-Edge Slant Target for Unlocalized MTF Measurement of Airborne Imaging System Payloads

Calibration of imaging instruments is a critical step in effectively characterizing imaging data. A comprehensive characterization of an imaging system provides valuable insight into the overall uncertainties in the results derived from the raw data collected. The Scientifically Calibrated In-Flight Imagery (SCIFLI) team (based at NASA Langley Research Center) has designed, built, tested, and successfully flown the optical payload known as the SCIFLI Airborne Multispectral Imager (SAMI). SAMI is a multispectral imaging payload, complete with sensor configurations for the Ultraviolet-Visible spectrum as well as Near- Infrared, Shortwave Infrared, and Midwave Infrared bands and is fitted with various optical hardware designed to turn, split, and focus light beams to the respective in-band sensors. Radiometric calibrations are performed for SAMI such that the accuracy and uncertainty of thermal and spectral measurements are effectively characterized. However, SAMI does not regularly undergo spatial characterizations to evaluate the performance of the imager at high spatial frequencies. This is essential, as understanding the spatial sensor response of discrete sensors is just as important as the spectral sensor response. The payload currently utilizes a calibration cart for lab testing. Equipped with a modular setup and several radiation sources, it is perfect for performing high-quality radiometric calibrations. This work focuses on using the calibration cart to perform spatial calibrations. A custom designed calibration target is being used to evaluate the optical performance of SAMI. Specifically, the target is designed to measure the Modulation Transfer Function (MTF) of the imager in discrete locations around the focal plane. The results of this characterization will provide insight into the spatial resolution capabilities of the SAMI payload in practice. Future work includes using the results of the study to correct optical imperfections in imagery taken with SAMI.

SAMI↗

Radiance standards

Two radiometric calibration sources that are utilized by various groups are maintained and operated. One source is a 6-ft diameter sphere and the other a 4-ft diameter hemisphere. Both are internally coated with multiple layers of barium sulfate and house an array of 12 tungsten filament-quartz iodine lamps that provide a uniform diffuse target of radiance traceable to NBS. The lamps are baffled and arranged so that they are not part of the scene during calibrations. Both systems have a 10-inch viewing aperture. The hemisphere is somewhat more versatile in that the aperture can be changed and the system is movable so calibrations can be done at other sites. Together, these systems have supported numerous GSFC projects and missions during this review period. They are listed.

Lester, D. L.↗

Emerging Techniques for Vicarious Calibration of Visible Through Short Wave Infrared Remote Sensing Systems

Autonomous Visible to SWIR ground-based vicarious Cal/Val will be an essential Cal/Val component with such a large number of systems. Radiometrically calibrated spectroradiometers can improve confidence in current ground truth data through validation of radiometric modeling and validation or replacement of traditional sun photometer measurement. They also should enable significant reduction in deployed equipment such as equipment used in traditional sun photometer approaches. Simple, field-portable, white-light LED calibration source shows promise for visible range (420-750 nm). Prototype demonstrated <0.5% drift over 10-40 C temperature range. Additional complexity (more LEDs) will be necessary for extending spectral range into the NIR and SWIR. LED long lifetimes should produce at least several hundreds of hours or more of stability, minimizing the need for expensive calibrations and supporting long-duration field campaigns.

Ryan, Robert E.↗