Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Multiple freezing–melting pathways of high-density ice through ice XXI phase at room temperature

Various metastable ice phases and their complicated transition pathways have been found by pressurization at low temperatures at which slow kinetics and high metastability are easily achieved. By contrast, such diversity is less expected at room or elevated temperatures. Here, using a combination of a dynamic diamond anvil cell and X-ray free electron laser techniques, we demonstrate that supercompressed water transforms into ice VI through multiple freezing–melting pathways at room temperature, hidden within the pressure region of ice VI. These multiple transition pathways occur via a metastable ice (more specifically, ice XXI with body-centred tetragonal structure ($I\bar{4}2d$)) discovered in this study and a metastable ice VII that exists within the pressure range of ice VI. We find that supercompressed water structurally evolves from high-density water to very-high-density water, causing multiple transition pathways. These findings provide an insight to find more metastable ice phases and their transition pathways at elevated temperatures.

Lee, Yun-Hee [Korea Research Institute of Standard↗

Twin Boundaries Contribute to The First Cycle Irreversibility of LiNiO 2

Abstract LiNiO 2 remains a target for layered oxide Li‐ion cathode development as it can theoretically deliver the highest energy density of this materials class. In practice, LiNiO 2 suffers from poor capacity retention due to electrochemically‐induced structural changes. While the impact of Ni off‐stoichiometry on the electrochemical performance has been extensively studied, that of planar defects present in the as‐synthesized cathode is not well understood. Advanced ex situ and operando structure probes are used to identify and quantify point and planar defects present in as‐synthesized Li 1‐y Ni 1+y O 2 cathodes and monitor their evolution during the first cycle. Specifically, a 7 Li nuclear magnetic resonance (NMR) signature characteristic of Li environments near twin boundaries is identified; an assignment supported by first‐principles calculations and scanning transmission electron microscopy (STEM) images of twin boundary defects. The NMR results suggest that the concentration of twin boundaries depends on the amount of Ni excess. Moreover, operando magnetometry and ex situ synchrotron X‐ray diffraction and NMR demonstrate that these planar defects impede Li reinsertion into the bulk cathode at reasonable discharge rates and contribute to the first cycle irreversible capacity. These findings provide new design rules for Li 1‐y Ni 1+y O 2 cathodes, whereby a reduced concentration of twin boundaries in the pristine material leads to reduced kinetic limitations and improved cathode utilization.

Nguyen, H.↗

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme ultraviolet microscope characterization using photomask surface roughness

We demonstrate a method for characterizing the field-dependent aberrations of a full-field synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent, atomic-scale roughness of readily-available photomask blanks enables a self-calibrating computational procedure using images acquired under standard operation. We characterize the aberrations across a 30-um field-of-view, demonstrating a minimum aberration magnitude of smaller than λ/21 rms averaged over the center 5-um area, with a measurement accuracy better than λ/180 rms. The measured field variation of aberrations is consistent with system geometry and agrees with prior characterizations of the same system. In certain cases, it may be possible to additionally recover the illumination wavefront from the same images. Our method is general and is easily applied to coherent imaging systems with steerable illumination without requiring invasive hardware or custom test objects; hence, it provides substantial benefits when characterizing microscopes and high-resolution imaging systems in situ.

47 OTHER INSTRUMENTATION↗

Measurement of post-disruption runaway electron kinetic energy and pitch angle during final loss instability in DIII-D

Post-disruption runaway electron (RE) kinetic energy K and pitch angle sin$\vartheta$ are critical parameters for determining resulting first wall material damage during wall strikes, but are very challenging to measure experimentally. During the final loss instability, confined RE K and sin$\vartheta$ are reconstructed during center-post wall strikes for both high impurity (high-Z) and low impurity (low-Z) plasmas by combining soft x-ray, hard x-ray, synchrotron emission, and total radiated power measurements. Deconfined (wall impacting) RE sin$\vartheta$ is then reconstructed for these shots by using time-decay analysis of infra-red imaging. Additionally, deconfined RE K and sin$\vartheta$ are reconstructed for a low-Z downward loss shot by analyzing resulting damage to a sacrificial graphite dome limiter. The damage analysis uses multi-step modeling simulating plasma instability, RE loss orbits, energy deposition, and finally material expansion (MARS-F, KORC, GEANT-4, and finally COMSOL). Overall, mean kinetic energies are found to be in the range $\langle$$K$$\rangle$ $≈ 3-4$ MeV for confined REs. KORC simulations indicate that the final loss instability process does not change individual RE kinetic energy K. In conclusion, confined RE pitch angles are found to be fairly low initially pre-instability, $\langle$sin$\vartheta$$\rangle$ $≈ 0.1 – 0.2$, but appear to increase roughly 2x, to $\langle$sin$\vartheta$$\rangle$ $≈ 0.3 – 0.4$ for both confined and deconfined REs during instability onset in the low-Z case; this increase is not observed in the high-Z case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developments in SRW Code and Sirepo Framework Supporting Simulation of Time-Dependent Coherent X-ray Scattering Experiments

Physical optics simulations for beamlines and experiments are essential for the effective use of synchrotron light source facilities such as NSLS-II at BNL. The SRW software package supports such source-to-detector simulations for coherent X-ray scattering and imaging experiments through its Python interface and Sirepo browser-based graphical user interface. This allows one to define custom sample models, assess the feasibility of an experiment, and estimate most appropriate beamline settings before using valuable beamtime. We discuss the recent use of general-purpose GPU resources and coherent mode decomposition algorithms in SRW to accelerate physical optics simulations with partially coherent X-rays. To illustrate these new capabilities, we describe simulations of typical time series of partially coherent scattering images used in X-ray Photon Correlation Spectroscopy (XPCS) experiments; aiming to characterize the nanoscale dynamics of a disordered sample, representing a solution of nanoparticles undergoing Brownian diffusion.

36 MATERIALS SCIENCE↗

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS↗

Pair Cascades in Magnetar Magnetospheres

Resonant inverse Compton scattering (RICS) of soft thermal photons by relativistic particles on closed magnetic field loops has been proposed to explain the hard emission observed up to and beyond 200 keV from magnetars. If particles injected at the base of the loops have Lorentz factors ≳10 2 , the RICS spectra will be attenuated by both one-photon pair production and photon splitting in the ultrastrong magnetar fields, producing additional spectral components from pair synchrotron radiation and split photons that produce further generations of pairs and split photons. We investigate such cascades initiated by the primary injected electrons through a Monte Carlo simulation, and study the cascade spectra and pair distributions. For most observer angles, the pair synchrotron and split-photon spectra dominate the RICS primary spectra and produce complex polarization signals. In particular, the synchrotron spectra are highly polarized with degree 40%–80%, are softer than the RICS spectra, and may account for the high polarization of some magnetar spectra observed by the Imaging X-ray Polarimetry Explorer above 3 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

An X-ray and radio study of steep-spectrum radio soruces. I - Four fields from the Clark Lake Observatory 26 MHz survey

A multifrequency study of fields containing steep-spectrum radio sources is presented. New spectral and spatial data are used to determine the locations and optical identifications of steep-spectrum sources which previously had either poor positions or questionable correspondence to known sources. X-ray images from the Einstein Observatory provide estimates of the extent, temperature, density, and thermal pressure of hot gas associated with galaxies and clusters of galaxies. From the equations relating synchrotron emission to inverse Compton scattering of 3 K background photons, lower limits to the average magnetic field strength in the source are derived. For the resolved radio sources of known distance, the minimum nonthermal pressure and the corresponding magnetic field strength are also calculated. For the four fields discussed in this paper, it is found that three out of five steep-spectrum sources are embedded in a cluster atmosphere and two are unidentified. Except for unresolved radio structures associated with cores of galaxies, the estimated thermal pressure is sufficient to confine the radio sources.

Harris, D. E.↗

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Residual strain orientation in rolled titanium determined with synchrotron X-ray Laue microdiffraction

Previously, synchrotron X-ray Laue microdiffraction has been used to measure the magnitudes of residual strain in materials. Recently the method was advanced to determine the orientation of the strain ellipsoid and applied to naturally deformed quartzites; however, the deformation history of these quartzites is ambiguous due to their natural origin. Here, in this study, synchrotron X-ray Laue microdiffraction (µXRD) is used to measure the residual strain for the first time in a sample with known stress history, rolled titanium. A deviatoric strain tensor is calculated from each Laue diffraction image collected with two µXRD scans of a rolled titanium sheet in different sample orientations. The principal strain axes are calculated using an eigen decomposition of the deviatoric strain tensors. The results show that the principal axis of compression is aligned with the normal direction of the titanium sheet, and the principal axis of extension is aligned with the rolling direction. Pole figures are used to represent the 3D distribution of residual strain axes.

36 MATERIALS SCIENCE↗

An Integrated High-Speed Microstructural Characterization Method Using Simultaneous XRD, Stereo-DIC, and PCI

High-speed characterization of the deformation mechanisms in polycrystalline metals requires the quantification of full strain fields and local microstructural evolutions simultaneously. In this paper, we present a novel experimental method to integrate phase-contrast imaging (PCI), stereographic digital image correlation (stereo-DIC), and full-ring X-ray diffraction (XRD) to allow for the simultaneous characterization of polycrystalline metals at 1MHz or higher. A Kolsky bar was integrated into the synchrotron X-ray source in Sector 32 ID-B at the Advance Photon Source (APS) at Argonne National Laboratory. When the sample is dynamically loaded, the diagnostic methods of full-ring XRD, PCI, and stereo-DIC are properly synchronized to record the deformation behavior at both continuum and microstructural scales as a function of the loading history. An advanced high-strength steel (AHSS) is used as a model material to demonstrate the capabilities of this new experimental method.

36 MATERIALS SCIENCE↗

Real-time tracking and analysis of gas bubble dynamics in laser powder bed fusion using in-situ X-ray characterization and machine learning

Porosity defects remain a significant challenge in the laser powder bed fusion (LPBF) process, adversely affecting the mechanical properties and reliability of additively manufactured components. Here, this study investigates the real-time formation and trajectory of gas bubbles during LPBF of Al6061 alloy using advanced in-situ X-ray characterization and machine learning. The unsupervised Gaussian mixture model and particle tracking algorithm developed are able to precisely track and quantify the properties of gas bubbles and keyhole pores. Our analysis identified five distinct types of gas bubble formation and movement patterns, emphasizing the diverse origins and behaviors of these defects. It enables precise quantification of trajectories, velocities, and morphological changes of gas bubbles, offering a granular view of the subsurface dynamics within the melt pool. Additionally, we explored keyhole-induced pore dynamics, revealing the critical role of keyhole oscillation and collapse for the formation of both large and small gas pores. It defines four different regions of gas bubble movement within the melt pool, providing a clearer understanding of how local fluid dynamics affect pore behavior. The results underscore the importance of integrating in-situ experimental observation and automated machine learning to develop a more robust predictive model for defect formation in LPBF.

In-situ X-ray imaging↗

TomoPyUI : a user-friendly tool for rapid tomography alignment and reconstruction

The management and processing of synchrotron and neutron computed tomography data can be a complex, labor-intensive and unstructured process. Users devote substantial time to both manually processing their data ( i.e. organizing data/metadata, applying image filters etc. ) and waiting for the computation of iterative alignment and reconstruction algorithms to finish. In this work, we present a solution to these problems: TomoPyUI , a user interface for the well known tomography data processing package TomoPy . This highly visual Python software package guides the user through the tomography processing pipeline from data import, preprocessing, alignment and finally to 3D volume reconstruction. The TomoPyUI systematic intermediate data and metadata storage system improves organization, and the inspection and manipulation tools (built within the application) help to avoid interrupted workflows. Notably, TomoPyUI operates entirely within a Jupyter environment. Herein, we provide a summary of these key features of TomoPyUI , along with an overview of the tomography processing pipeline, a discussion of the landscape of existing tomography processing software and the purpose of TomoPyUI , and a demonstration of its capabilities for real tomography data collected at SSRL beamline 6-2c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibration of the Multi-Spectral Solar Telescope Array multilayer mirrors and XUV filters

The Multi-Spectral Solar Telescope Array (MSSTA), a rocket-borne solar observatory, was successfully flown in May, 1991, obtaining solar images in eight XUV and FUV bands with 12 compact multilayer telescopes. Extensive measurements have recently been carried out on the multilayer telescopes and thin film filters at the Stanford Synchrotron Radiation Laboratory. These measurements are the first high spectral resolution calibrations of the MSSTA instruments. Previous measurements and/or calculations of telescope throughputs have been confirmed with greater accuracy. Results are presented on Mo/Si multilayer bandpass changes with time and experimental potassium bromide and tellurium filters.

Allen, Maxwell J.↗

Determining the Quantum Detection Efficiency of A Soft X-Ray Micro-Channel Plate Detector for the Lunar Mission, LEXI

Micro-channel plate (MCP) detectors have long been a workhorse for space-based x-ray research and are advantageous over other imaging detectors because of their low size, weight and power. The Lunar Environment heliospheric x-ray Imager (LEXI), will utilize a MCP to image Earth’s magnetosphere in soft x-rays from the lunar surface. A critical element for interpreting on-orbit data is to understand the quantum detection efficiency (QDE) of the MCP. LEXI’s MCP is coated with potassium bromide (KBr) to increase the soft x-ray QDE. Historically, few measurements of QDE exist in the soft x-ray band for KBr detectors. This paper reviews the performance of LEXI’s detector, and the QDE experiment procedure conducted at and results from the Advanced Light Source synchrotron soft x-ray beam line (6.3.2) over the energy range 70eV-1300eV. A unique beam line setup was required to limit the photon flux as to not saturate the pores of the MCP or detector signal chain. The experimental results are similar to previous literature, with some caveats unique to this MCP and experimental setup.

X-ray imaging↗

An in situ imaging investigation of the effect of gas flow rates on directed energy deposition

Gas flow rates in Directed Energy Deposition (DED) Additive Manufacturing (AM) can significantly affect the quality of built parts by altering melt pool geometry. Using a DED process replicator and in situ synchrotron radiography, together with analogous experiments in an industrial DED machine, we investigate the impact of carrier gas and shield gas flow rates on build quality. The results reveal that there is a critical shield gas flow rate above which melt pools are flattened, tracks widen, and thus layer thickness decreases. The reduction in layer thickness is most prominent in conditions with low carrier gas flow rate, as the highly turbulent shield gas flow may divert slow moving powder particles away from the melt pool, decreasing capture efficiency. Very high flow rates increase internal porosity, as fast-moving particles impacting the melt pool surface can entrain chamber gas behind them. High gas flow rates also cool the melt pool, creating shallower melt pools with increased thermal gradients near the solidification front, increasing pore entrapment in the solidified track.

Additive manufacturing↗