Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “suspensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Material suspension within an acoustically excited resonant chamber

A method is described for positioning an object within a chamber, which is especially useful in performing manufacturing operations under zero gravity conditions. Sound waves are applied within the chamber in different directions and at a frequency for each direction that establishes a standing wave pattern so that the object is automatically urged towards the intersections of the nodes, or locations of minimum pressure.

Wang, T. G.↗

A mobile planetary lander utilizing elastic loop suspension

Efforts to increase the cost effectiveness of future lunar and planetary rover missions have led to the mobile lander concept, which replaces the landing legs of a soft-lander craft with a compact mobility system of sufficient strength to withstand the landing impact. The results of a mobile lander conceptual design effort based on existing NASA-Viking '75 hardware are presented. The elastic loop concept, developed as a post-Apollo rover technology, is found to meet stringent stowage, traction, power and weight requirements.

Trautwein, W.↗

Operational loopwheel suspension systems for Mars Rover demonstration model: Loopwheel failure report

The results are presented from the analysis of a failure which occurred in the fiberglass loop of one of the Loopwheel traction elements delivered to the Jet Propulsion Laboratory (JPL) for use on the JPL Mars Rover demonstration model. The loop failed in compression in the outer fibers forming a hinge which, through cycling, caused the inner fibers to break. The probable cause of this failure was the load being introduced as point loads at the center of the loop causing high compressive stresses and early buckling. To decrease the stress level and delay buckling, the tread lugs can be reshaped so that the entire lug contacts the ground when the loop is loaded. This can be accomplished through removal of lug material, starting with zero removal at the outer edge and linearly increasing to one-half of the lug thickness at the center.

West, E. J. M.↗

Spraying suspensions uniformly

With head on each of its ends, bolt can be disengaged from its blind side. Bolt has conventional hexagonal head on one end and smaller hexagonal head on its threaded end. Since reduced head is smaller than bolt diameter, it does not interfere with insertion of bolt shank in bolthole. However, it can be turned by wrench to release bolt from its blind (threaded) end. Bolt should be tethered on its large-head end so that it does not drop away from assembly.

Prasthofer, W. P.↗

Magnetic suspension system for an Annular Momentum Control Device (AMCD)

A technique to control a rim suspended in a magnetic field was developed. A complete system was developed, incorporating a support structure, magnetic actuators, a rim drive mechanism, an emergency fail-safe system, servo control system, and control electronics. Open loop and closed loop response of the system at zero speed and at 500 revolutions per minute (r/min) of the rim was obtained and analyzed. The rim was then dynamically balanced and a rim speed of 725 r/min was achieved. An analog simulation of the hardware was developed and tested with the actual control electronics connected to the analog computer. The system under development is stable at rim speeds below 700 r/min. Test results indicate that the rim under test is not rigid. The rim has a warp and a number of binding modes which prevented achievement of higher speeds. Further development efforts are required to achieve higher rim speeds.

Source record↗

Electromagnet configurations for extreme attitude testing in magnetic suspension and balance systems

The inclusion of adequate versatility into the electromagnet array configuration requires sizing the electromagnets to satisfy particular absolute force and moment requirements. Magnetic performance of a permanent magnet model core, air cored electromagnet may easily and reliably be computed by using the FORCE program which calculates model forces and moments via representations of the model as an assembly of dipoles and the electromagnets as an assembly of line currents. Some aspects of the performance of an ellipsoidal iron cored model may be inferred from the above under certain circumstances.

Britcher, C. P.↗

Elastic suspension of a wind tunnel test section

Experimental verification of the theory describing arbitrary motions of an airfoil is reported. The experimental apparatus is described. A mechanism was designed to provide two separate degrees of freedom without friction or backlash to mask the small but important aerodynamic effects of interest.

Hacker, R.↗

Development of the design concepts for a medium-scale wind tunnel magnetic suspension system

The magnitude of AC losses from a superconducting coil strongly indicates that the predicted scaling lawa are valid. The stainless steel bands around the test coil were the source of additional helium boiloff due to a transformer action and, hence, caused erroneously high AC loss measurements in the first run. However, removal of these bands for the second run produced data which are consistent with previous results on small scale multifilamentary superconducting coils.

Humphris, R. R.↗

A study of the photocatalytic effects of aqueous suspensions of platinized semiconductor materials on the reaction rates of candidate redox reactions

The effectiveness of powdered semiconductor materials in photocatalyzing candidate redox reactions was investigated. The rate of the photocatalyzed oxidation of cyanide at platinized TiO2 was studied. The extent of the cyanide reaction was followed directly using an electroanalytical method (i.e. differential pulse polarography). Experiments were performed in natural or artificial light. A comparison was made of kinetic data obtained for photocatalysis at platinized powders with rate data for nonplatinized powders.

Miles, A. M.↗

Acoustic suspension system

An acoustic levitation system is described, with single acoustic source and a small reflector to stably levitate a small object while the object is processed as by coating or heating it. The system includes a concave acoustic source which has locations on opposite sides of its axis that vibrate towards and away from a focal point to generate a converging acoustic field. A small reflector is located near the focal point, and preferably slightly beyond it, to create an intense acoustic field that stably supports a small object near the reflector. The reflector is located about one-half wavelength from the focal point and is concavely curved to a radius of curvature (L) of about one-half the wavelength, to stably support an object one-quarter wavelength (N) from the reflector.

Lee, M. C.↗

Settling of fixed erythrocyte suspension droplets

It is pointed out that when particles behave collectively rather than individually, the fractionation of micron-size particles on the basis of size, density, and surface characteristics by centrifugation and electrophoresis is hindered. The formation and sedimentation of droplets containing particles represent an extreme example of collective behavior and pose a major problem for these separation methods when large quantities of particles need to be fractionated. Experiments are described that measure droplet sizes and settling rates for a variety of particles and droplets. Expressions relating the particle concentration in a drop to measurable quantities of the fluids and particles are developed. The number of particles in each droplet is then estimated, together with the effective droplet density. Red blood cells from different animals fixed in glutaraldehyde provide model particle groups.

Omenyi, S. N.↗

Metabolic alterations caused by suspension hypokinesia in leg muscles of rats

Metabolic changes on hypokinetic rats were measured. Two groups of animals were studied: (1) weight bearing control which were tail casted but allowed to walk on all four limbs, and (2) hypokinetic with no load bearing of the hindlimbs. The control and hypokinetic rats gained weight at a steady and similar rate over 6 days. Hypokinesia for 6 days led to significantly lower relative weights of the soleus, gastrocnemius and plantaris muscles. Hypokinesia did not effect the relative mass of the anterior tibialis or extensor digitorum longus (EDL) muscles.

Tischler, M. E.↗

The influence of rat suspension-hypokinesia on the gastrocnemius muscle

Hind-limb hypokinesia was induced in rats by the Morey method to characterize the response of the gastrocnemius muscle. A comparison of rats suspended for 2 weeks with weight, sex, and litter-matched control rats indicate no difference in gastrocnemius wet weight, contraction, or one-half relaxation times, but less contractile function as indicated by lowered dP/dt. Myosin ATPase staining identified uniform Type I (slow-twitch) and II (fast-twitch) atrophy in the muscles from 4 of 10 rats suspended for 2 weeks and 1 of 12 rats suspended for 4 weeks; muscles from three other rats of the 4-week group displayed greater Type I atrophy. Other histochemical changes were characteristic of a neuropathy. These data together with recently acquired soleus data (29) indicate the Morey model, like space flight, evokes greater changes in the Type I or slow twitch fibers of the gastrocnemius and soleus muscles.

Templeton, G. H.↗

Characteristics of the Elevation Drive Suspension of the 64-meter Antennas

The elevation axis drive unit of the DSN 64-m antennas is arranged so that its output pinion can self-align to the bull gear. The design is described and conflicting desiderata are discussed. Static stability criterion for the elevation drive, derivation of strut stiffness ratios, and an outline for removing, installing, and adjusting the vertical struts are included.

Mcginness, H. D.↗

Response of amino acids in hindlimb muscles to recovery from hypogravity and unloading by tail-cast suspension

Concentrations of glutamine, glutamate, aspartate (+ asparagine) and alanine were compared in hindlimb muscles of SL-3 and ground control rats. Alanine was lower in the soleus of flown rats but not of suspended animals, with no response in other muscles except a slight increase in the unloaded plantaris. With recovery, alanine in the soleus was elevated. Since no differences in alanine metabolism were found by isolated muscle, changes in muscle alanine are probably due to altered body use of this amino acid leading to varied plasma levels.

Tischler, M. E.↗

Response of rat hindlimb muscles to 12 hours recovery from tail-cast suspension

Previous work has shown a number of biochemical changes which accompany atrophy or reduced muscle growth in hindlimb of tail-casted, suspended rats. These results clearly show that altered muscle growth was due to changes in protein turnover. Accordingly, the rise in soleus tyrosine following unloading reflects the more negative protein balance. Other major changes we found included slower synthesis of glutamine as indicated by lower ratios of glutamine/glutamate and reduced levels of aspartate which coincide with slower aspartate and ammonia metabolism in vitro. In conjunction with the study of SL-3 rats, which were subjected to 12 h of post-flight gravity, a study of the effects of 12 h eight bearing on metabolism of 6-day unloaded hindlimb muscles was carried out.

Tischler, M. E.↗