Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Thermal analysis of heat storage canisters for a solar dynamic, space power system

A thermal analysis was performed of a thermal energy storage canister of a type suggested for use in a solar receiver for an orbiting Brayton cycle power system. Energy storage for the eclipse portion of the cycle is provided by the latent heat of a eutectic mixture of LiF and CaF2 contained in the canister. The chief motivation for the study is the prediction of vapor void effects on temperature profiles and the identification of possible differences between ground test data and projected behavior in microgravity. The first phase of this study is based on a two-dimensional, cylindrical coordinates model using an interim procedure for describing void behavor in 1-g and microgravity. The thermal analysis includes the effects of solidification front behavior, conduction in liquid/solid salt and canister materials, void growth and shrinkage, radiant heat transfer across the void, and convection in the melt due to Marangoni-induced flow and, in 1-g, flow due to density gradients. A number of significant differences between 1-g and o-g behavior were found. This resulted from differences in void location relative to the maximum heat flux and a significantly smaller effective conductance in 0-g due to the absence of gravity-induced convection.

Wichner, R. P.↗

Electron trapping optical data storage system and applications

A new technology developed at Optex Corporation out-performs all other existing data storage technologies. The Electron Trapping Optical Memory (ETOM) media stores 14 gigabytes of uncompressed data on a single, double-sided 130 mm disk with a data transfer rate of up to 120 megabits per second. The disk is removable, compact, lightweight, environmentally stable, and robust. Since the Write/Read/Erase (W/R/E) processes are carried out photonically, no heating of the recording media is required. Therefore, the storage media suffers no deleterious effects from repeated W/R/E cycling. This rewritable data storage technology has been developed for use as a basis for numerous data storage products. Industries that can benefit from the ETOM data storage technologies include: satellite data and information systems, broadcasting, video distribution, image processing and enhancement, and telecommunications. Products developed for these industries are well suited for the demanding store-and-forward buffer systems, data storage, and digital video systems needed for these applications.

Brower, Daniel↗

Space station experiment definition: Long term cryogenic fluid storage

A preliminary design of an experiment to demonstrate and evaluate long-term cryogenic fluid storage and transfer technologies has been performed. This Long-Term Cryogenic Fluid Storage (LTCFS) experiment is a Technology Development Mission (TDM) experiment proposed by the NASA Lewis Research Center to be deployed on the Initial Operational Capability (IOC) space station. Technologies required by future orbital cryogenic systems such as Orbital Transfer Vehicles (OTV's) were defined, and critical technologies requiring demonstration were chosen to be included in the experiment. A three-phase test program was defined to test the following types of technologies: (1) Passive Thermal Technologies; (2) Fluid Transfer Technologies; and (3) Active Refrigeration Technologies. The development status of advanced technologies required for the LTCFS experiment is summarized, including current, past and future programs.

Riemer, David H.↗

Leveraging large language models to address data scarcity in machine learning for graphene synthesis

Machine learning in experimental materials science faces significant challenges due to the scarcity of data, which are costly and time-consuming to generate, particularly when relying on in-house experiments. Literature data mining offers a potential solution but introduces issues like mixed data quality, inconsistent formats, and non-uniform reporting of synthesis parameters, resulting in partially missing and heterogeneous features across the dataset. Here, we propose data imputation and feature engineering methods that employ pre-trained large language models (LLMs) to enhance machine learning performance on scarce, heterogeneous datasets, demonstrated on graphene CVD synthesis data and the ML-HydPARK hydrogen storage dataset. GPT models perform data imputation via tailored prompting and semantic normalization of inconsistently reported features through embeddings, for example, to harmonize the complex nomenclature of CVD substrates. Beyond yielding more diverse and richer feature representations than traditional methods such as K-nearest neighbors (KNN) and Multivariate Imputation by Chained Equations (MICE), LLM-based data imputation is evaluated against dataset characteristics and prompting strategies. We vary the level of autonomy granted to the LLM, from generic prompting that leverages pre-trained knowledge for autonomous data generation to data-informed prompting that constrains outputs using target-specific information, and demonstrate which level of autonomy yields superior imputation performance across datasets and feature types. The proposed data engineering methods markedly improve downstream performance; for example, in graphene layer number classification using a support vector machine (SVM), binary accuracy increases from 39% to 65% and ternary accuracy from 52% to 72%. Fine-tuning experiments on both datasets show that combining our proposed LLM-based data imputation and feature encoding methods with numerical machine learning predictors outperforms standalone fine-tuned LLM predictors in data-scarce settings. The proposed strategies emphasize data enhancement techniques rather than refining learning architectures or regularizing loss functions, offering a broadly applicable framework for improving machine learning performance on scarce, inhomogeneous datasets.

Chemical vapor deposition↗

NASA-SETI microwave observing project: Targeted Search Element (TSE)

The Targeted Search Element (TSE) performs one of two complimentary search strategies of the NASA-SETI Microwave Observing Project (MOP): the targeted search. The principle objective of the targeted search strategy is to scan the microwave window between the frequencies of one and three gigahertz for narrowband microwave emissions eminating from the direction of 773 specifically targeted stars. The scanning process is accomplished at a minimum resolution of one or two Hertz at very high sensitivity. Detectable signals will be of a continuous wave or pulsed form and may also drift in frequency. The TSE will possess extensive radio frequency interference (RFI) mitigation and verification capability as the majority of signals detected by the TSE will be of local origin. Any signal passing through RFI classification and classifiable as an extraterrestrial intelligence (ETI) candidate will be further validated at non-MOP observatories using established protocol. The targeted search will be conducted using the capability provided by the TSE. The TSE provides six Targeted Search Systems (TSS) which independently or cooperatively perform automated collection, analysis, storage, and archive of signal data. Data is collected in 10 megahertz chunks and signal processing is performed at a rate of 160 megabits per second. Signal data is obtained utilizing the largest radio telescopes available for the Targeted Search such as those at Arecibo and Nancay or at the dedicated NASA-SETI facility. This latter facility will allow continuous collection of data. The TSE also provides for TSS utilization planning, logistics, remote operation, and for off-line data analysis and permanent archive of both the Targeted Search and Sky Survey data.

Webster, L. D.↗

Magnetically Levitated and Constrained Flywheel Energy Storage System

The concept of using linear induction motors to lift, constrain, accelerate, and decelerate a large-scale flywheel is proposed, and some of the advantages are investigated. Calculations for a Magnetically Levitated Energy Storage System (MLES) are performed that compare a single large scale MLES with a current state of the art flywheel energy storage system in order to show the relative differences and advantages of such a system. The system that is used for comparison is a typical Beacon Power flywheel energy system. This is currently one of the state-of-the-art flywheel energy storage systems and so it can be used to provide a basic data set to compare to an MLES system.

VanOsdol, John↗

Small Hydropower Plant Response Improvement Using Energy Storage

Small hydropower plants contribute significantly to global power generation. However, due to limited storage, these can have low ramping capacity and poor load-frequency regulation. These can prevent small hydropower plants from being used in isolated grids as backup power to critical loads and rural areas. In this paper, a control architecture for frequency control is proposed that facilitates the use of energy storage to improve the response of standalone small hydropower plants. The frequency controller generates power commands using proportional control on frequency deviation and a user-defined power setpoint, and this incorporates with a current controller that facilitates power injection. The distinctive feature of the controller design is that it takes into account frequency thresholds and storage constraints to enable power injections, and it provides the capability to perform automated and manual recharge of the energy storage. Simulations using detailed nonlinear models demonstrate the improved performance of the hydropower with energy storage using the proposed controller. Automated and manual recharge and the impact of the energy storage constraints on the performance of the hydropower plant are demonstrated.

13 HYDRO ENERGY↗

I/O performance studies of analysis workloads on production and dedicated resources at CERN

The recent evolutions of the analysis frameworks and physics data formats of the LHC experiments provide the opportunity of using central analysis facilities with a strong focus on interactivity and short turnaround times, to complement the more common distributed analysis on the Grid. In order to plan for such facilities, it is essential to know in detail the performance of the combination of a given analysis framework, of a specific analysis and of the installed computing and storage resources. This contribution describes performance studies performed at CERN, using the EOS disk-based storage, either directly or through an XCache instance, from both batch resources and highperformance compute nodes which could be used to build an analysis facility. A variety of benchmarks, both synthetic and based on real-world physics analyses and their corresponding input datasets, are utilized. In particular, the RNTuple format from the ROOT project is put to the test and compared to the latest version of the TTree format, and the impact of caches is assessed. In addition, we assessed the difference in performance between the use of storage system specific protocols, like XRootd, and FUSE. The results of this study are intended to be a valuable input in the design of analysis facilities, at CERN and elsewhere.

Sciabà, Andrea↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Li-Ion Battery Degradation and Performance [Slides]

This presentation is intended for power system engineers, operators, and planners who work on isolated power systems that have (or may soon have) high levels of power generation coming from wind turbines, solar farms, and battery energy storage, which are collectively referred to as inverter-based resources. It describes the basics of lithium-ion battery energy storage systems and lithium-ion battery degradation. Battery degradation at the cell-level is explained, and then the structure and degradation of battery energy storage systems is also explained. This is intended to help power system engineers, operators, and planners to understand and effectively utilize battery energy storage systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review on Advanced Manufacturing for Hydrogen Storage Applications

Hydrogen is a notoriously difficult substance to store yet has endless energy applications. Thus, the study of long-term hydrogen storage, and high-pressure bulk hydrogen storage have been the subject of much research in the last several years. To create a research path forward, it is important to know what research has already been done, and what is already known about hydrogen storage. In this review, several approaches to hydrogen storage are addressed, including high-pressure storage, cryogenic liquid hydrogen storage, and metal hydride absorption. Challenges and advantages are offered based on reported research findings. Since the project looks closely at advanced manufacturing, techniques for the same are outlined as well. There are seven main categories into which most rapid prototyping styles fall. Each is briefly explained and illustrated as well as some generally accepted advantages and drawbacks to each style. An overview of hydrogen adsorption on metal hydrides, carbon fibers, and carbon nanotubes are presented. The hydrogen storage capacities of these materials are discussed as well as the differing conditions in which the adsorption was performed under. Concepts regarding storage shape and materials accompanied by smaller-scale advanced manufacturing options for hydrogen storage are also presented.

36 MATERIALS SCIENCE↗

Techno-Economic Analysis of Hydrogen Production and Compressed Air Energy Storage from Variable Renewable Energy

Examines the performance and cost of pairing variable renewable energy (VRE) sources with compressed air energy storage and hydrogen production through PEM electrolysis. Sensitivities were performed on H2 cost, PEM electrolyzer capital cost, and hydrogen cavern capital cost. The analysis shows that the cost of VRE has the most impact on the overall cost results.

Teel, Troy↗

Long term cryogenic storage system integration

Investigations have revealed significant increases in performance when a reliquefier and solar shield in conjunction with a zero-gravity vapor vent system are utilized. Application of a reliquefier and solar shield in long term deep space missions may effect a 60% reduction in propellant loss, compared to that associated with the vapor vent system only. Significant improvements in storage system performance are possible for low earth orbit applicatons; for the typical system that was evaluated, system performance gains were realized for mission durations exceeding 7 days. Spherical solar shields are generally not competitive for low earth orbit applications.

Stonemetz, R. E.↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Design and evaluation of thermodynamic vent/screen baffle cryogenic storage system

A comprehensive analytical program was performed to compare an integrated thermodynamic vent/screen baffle orbital cryogenic propellant storage and transfer system with other concepts. The screen systems were found to be 20% to 29% lighter in weight than a propulsively accelerated Tug-scale LH2/LO2 resupply module. The screen systems were compared with small-scale supercritical storage systems for the space shuttle fuel cell reactant and life support system fluid supply and were lighter by up to 556 kg (1225 lb) for the extended 30-day mission. When compared with high-pressure gas storage for the spacelab atmosphere supply, the screen system saved 79% of the inert system weight for the 30-day mission. An experimental program found that heat flux rates up to 9,450 watts/sq m (3,000 Btu/hr-sq ft) degraded the LH2 bubble point performance of eight screens by a maximum of 12.5%. No effects of helium pressurant, screen material, or LH2 superheat were observed.

Cady, E. C.↗

Encapsulation materials research

Encapsulation materials for solar cells were investigated. The different phases consisted of: (1) identification and development of low cost module encapsulation materials; (2) materials reliability examination; and (3) process sensitivity and process development. It is found that outdoor photothermal aging devices (OPT) are the best accelerated aging methods, simulate worst case field conditions, evaluate formulation and module performance and have a possibility for life assessment. Outdoor metallic copper exposure should be avoided, self priming formulations have good storage stability, stabilizers enhance performance, and soil resistance treatment is still effective.

Willis, P. B.↗

Evolving Storage and Cyber Infrastructure at the NASA Center for Climate Simulation

This talk will describe recent developments at the NASA Center for Climate Simulation, which is funded by NASAs Science Mission Directorate, and supports the specialized data storage and computational needs of weather, ocean, and climate researchers, as well as astrophysicists, heliophysicists, and planetary scientists. To meet requirements for higher-resolution, higher-fidelity simulations, the NCCS augments its High Performance Computing (HPC) and storage retrieval environment. As the petabytes of model and observational data grow, the NCCS is broadening data services offerings and deploying and expanding virtualization resources for high performance analytics.

Cyberinfrastructure↗