Clean is not Sterile: A Planetary Science and Planetary Protection Perspective on Cleanroom Microbiology at NASA
The Astromaterials Acquisition and Curation Office at NASA is responsible for the curation of extraterrestrial samples from NASA’s past and future sample return missions. Our office curates samples from the moon, meteorites, comets, asteroids, cosmic dust and solar wind particles. All these samples are kept in cleanrooms to limit particulate and trace metal contamination, but none of these cleanrooms are specifically designed to control microbial contamination. During the early Apollo missions NASA scientists were very concerned with protecting the Earth from potential microbial contamination from the moon and with protecting the lunar samples from terrestrial microbes. NASA developed specialized equipment and clean rooms to keep these collections pristine. However, as we learned more about the lunar environment our concerns about microbial contamination lessened. Today none of the existing collections have microbial contamination requirements because they are not considered susceptible to microbial alteration under curation conditions (e.g. solar wind samples, and lunar samples) or have already been contaminated by terrestrial biology (meteorites collected in Antarctica). However, NASA’s OSIRIS-REx mission will land in 2023 with samples from a carbon rich asteroid that will be susceptible to microbial alteration. The Perseverance rover on Mars will begin to collect and cache samples that will be returned to Earth as soon as 2031. Martian samples may contain signs of extraterrestrial life and will have to be treated like the early Apollo samples. Martian samples will be isolated to protect the Earth, and must also be protected from terrestrial contamination. I will present microbial monitoring data from existing NASA cleanrooms and discuss how NASA is planning to use techniques from the pharmaceutical industry and academia to design new laboratories and equipment that will protect astromaterials and the earth from unwanted microbial contamination. I will also discuss a project to sample the external microbiome of the International Space Station. Results from this research will be used to design facilities for use on Mars that limit the amount of contamination associated with crewed missions.
Producing Sterile IV Fluids on the International Space Station: Intravenous Generation Mini (IVGEN Mini) Project
Explore the source record for details and available documents.
Ultrashort Pulse Laser Surface Processing Techniques for Sterilization of Surfaces for Planetary Protection
Explore the source record for details and available documents.
Radiation Shielding of the Europa Lander Concept Terminal Sterilization System (TSS).
Abstract not provided.
2021 Midwest Medical Device Sterilization Workshop: Summary Report
Explore the source record for details and available documents.
A Search for Sterile Neutrino Oscillations in the MicroBooNE Experiment Using Deep Learning Reconstruction and Event Selection
Explore the source record for details and available documents.
Improved Tantalum-based Superconducting Tunnel Junction Radiation Detectors for a Sterile Neutrino Search
Explore the source record for details and available documents.
Establishing and Monitoring an Aseptic Workspace
When are aseptic operations necessary? In order to meet certain bioburden requirements, some components must undergo dry heat microbial reduction (DHMR) or other sterilizing procedures. If sensitive surfaces must be re-exposed after DHMR, this could compromise the bioburden levels. Recontaminating sterilized surfaces could be costly both in time by requiring repeated DHMR and risk to the hardware, which may not be compatible with repeated high temperature bakes. In order to prevent recontamination of the sensitive surfaces, an aseptic environment and sterile technique must be employed. Aseptic environments mean working in a space with almost no detectable bioburden in the air or on surfaces. Ideally, DHMR happens as late as possible to avoid requiring aseptic operations, as it can be considered a high-risk operations. Preparing the cleanroom for aseptic operations Establishing an ISO (International Organization for Standardization) class 5 space to minimize airborne particles. Maintain low bioburden in the cleanroom by using biocidal cleaners. Using multiple biocidal techniques decreases the likelihood of selecting for resistant microorganisms. 70% Isopropyl Alcohol (IPA) denatures the proteins in a microorganism (note: 70% IPA is better at killing microorganisms than 100% IPA) 7% hydrogen peroxide: damages DNA and proteins through oxygen radical damage. Ultraviolet-C (UV-C) lamps: causes crosslinking in DNA which prevents replication. Monitor cleanroom regularly for bioburden trending: Standard bioassay: Swab or wipe samples of cleanroom surfaces processed for colony forming unity (viable or spore selected); Rapid bioassay: Adenosine triphosphate (ATP) or Limulus amebocyte lysate (LAL) for a bioburden snapshot. High levels can signal an immediate re-cleaning before standard bioassay samples are taken. Airborne monitoring: Active (pulling air through a filter) or passive (particle fallout) for bioburden. Verify bioburden levels just before aseptic operation. Test hardware and cleanroom surfaces and air 3 days before the planned aseptic operation. Rapid bioburden just before aseptic operation to ensure room was not re-contaminated. Preparing personnel and tools: Personnel training. Everyone in the cleanroom: Standard cleanroom certification Everyone on the team: 1 day Planetary Protection overview. Aseptic operators only: Half-day aseptic operations training. Covers sterile garmenting/gloves, Sterile handling with a focus on contact transfer risk, tool/GSE preparation, and two-operator system for opening sterilized tools/components. Tool sterilization: All tools to be used during an aseptic operation need to be identified. Compatible tools are sterilized by DHMR or Autoclave. Double wrapped so that the exterior bag can be handled by a non-sterile operator, and the sterile. Tools that are not compatible with high heat do not come in contact with sensitive surfaces: either substitutes are found, or tools are isolated by wrapping in sterile foil. During an aseptic operation. Pre-task to make sure everyone understands the operations, who is handling what, and when the most critical surfaces will be exposed. Monitoring during the operation. Bioburden: active and passive airborne bioburden sampling, glove-tip dabs onto a plate after completion of operation (3 days for results). Particles: real time particle counter constantly running, with alarm for exceeding ISO 5 conditions.
Contamination analysis and monitoring
"Sterilization" is a term applied to any process or procedure that produces a condition of sterility. Sterility is an absolute concept and refers to the destruction or removal of all life. However, when sterility as an absolute concept is applied to the sterilization of space hardware, it ceases to be operational. Absolute proof of sterility of flight hardware is impossible. Hence, for an operational approach to certification of sterility of space hardware, it is necessary to apply the probability concept. The present report is concerned with the applicability of mathematics to predict the probability of achieving sterility in a complex space hardware system. As such, this approach is concerned with the manipulation of microbiological data rather than mathematical rigor.
Aseptic Handling of the MOMA Mass Spectrometer After Dry Heat Microbial Reduction
Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is an instrument in the larger MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. As a life-detection instrument on a Mars landing mission, MOMA-MS has very stringent Planetary Protection (PP) bioburden requirements. Within the MOMA instrument suite, the hardware surfaces of the sample path must be cleaned to a level of 0.03 spore/sq m. To meet this requirement, a process called Dry Heat Microbial Reduction (DHMR) is used to decrease the number of viable spores by 4 orders of magnitude. Before DHMR, the hardware is handled using standard cleanroom practices, while after DHMR, all sample path surfaces must be handled aseptically when exposed. Aseptic handling of the sample path involves a number of strategies and protocols including working only in an aseptic ISO class 5 work space, limiting the amount of time of exposure, using sterile garmenting with sterile gloves, and using sterile tools. Before work begins, the aseptic workspace will be tested for bioburden and particle fallout, and all tools that will contact sample path surfaces must be sterilized. During the exposure activity, sterile garments will be worn, sterile tools will be handled in a 2 person set up so that the operator touches only the sterile tool and not the exterior surfaces of the sterile pouch, and the environment will be monitored with active and passive fallout for bioburden and particle levels. Any breach in the planetary protection cleanliness can necessitate repeating DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.