Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stabilized”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Small-Signal Stability Constrained Optimal Power Flow of Inverter-Dominated Power Systems with Flexible Operation Mode Selection

Given the intermittence and low inertia nature of inverter-based resources (IBRs), modern power systems with high penetration of IBRs challenge the conventional optimal power flow (OPF) analysis and the system may experience unexpected failures if stability constraints are not incorporated. This study proposes a small-signal stability-constrained OPF (SSSC-OPF) with flexible operation mode selection between grid-forming (GFM) and grid-following (GFL) modes for IBRs to address these challenges. The approach aims to maintain system stability with a sufficient stability margin while minimizing operation costs. The effectiveness of the proposed method is validated through extensive case studies on the IEEE 14-bus system. The results demonstrate that the proposed method is able to support system-level power flow analysis, reduce generation costs, and ensure stability under various disturbances.

grid-following↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

Optimal Power Flow in DC Networks with Robust Feasibility and Stability Guarantees

With high penetrations of renewable generation and variable loads, there is significant uncertainty associated with power flows in DC networks such that stability and operational constraint satisfaction are of concern. Most existing DC network optimal power flow (DN-OPF) formulations assume exact knowledge of loading conditions and do not provide stability guarantees. Here, in contrast, this paper studies a DN-OPF formulation which considers both stability and operational constraint satisfaction under uncertainty. The need to account for a range of uncertainty realizations in this paper's robust optimization formulation results in a challenging semi-infinite program (SIP). The proposed solution algorithm reformulates this SIP into a computationally tractable problem by constructing a tight convex inner approximation of the stability set using sufficient conditions for the existence of a feasible and stable power flow solution. Optimal generator set-points are obtained by optimizing over the proposed convex stability set. The validity and effectiveness of the propose algorithm is demonstrated through various DC networks adapted from IEEE test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING↗

Tri-Sectional Approximation of the Shortest Path to Long-Term Voltage Stability Boundary with Distributed Energy Resources

Ensuring long-term voltage stability is critical for reliable operations of power grids. High share of distributed energy resources (DERs) can create complicated system operation modes that may invalidate the traditional long-term voltage stability analysis based on typical operation modes. To address this challenge, this paper investigates how to compute the shortest path to the voltage stability boundary in the DER aggregated load space with large dispersion. Instead of working in the Euclidean space, we establish the analysis and computations on the algebraic power flow manifold to better capture the curvature change of the shortest path along the direction of losing stability. A modified optimal control framework is presented for obtaining the ground-truth of the smooth shortest path on the manifold. To efficiently and accurately solve for the shortest path, we further leverage the geometric features of the power flow manifold and propose a tri-sectional approximation model that is scalable for large-scale systems. Several numerical examples, up to the 1354-bus system, with different DER penetration levels and high dimensional renewable power injection variations are evaluated. The simulation results demonstrate that the tri-sectional approximation achieves high accuracy and efficiency to approximate the shortest path to the voltage stability boundary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Site Disorder as a Predictor for Compositionally Complex 5RE 2 Zr 2 O 7 Ceramic Phase Stability

Here, phase formation and stability of five component compositionally complex rare earth zirconates (5RE 2 Zr 2 O 7 ) were investigated by X-ray diffraction and electron microprobe analysis. Zirconates with different rare earth compositions (LaNdSmEuDy, LaNdSmEuYb, LaNdEuErYb, LaNdDyErYb, SmEuDyYHo, LaYHoErYb, and DyYHoErYb) were synthesized at 1700°C and 2000°C by the solid-state method to investigate the effect of A-site site disorder (δ A ) on phase stability. Increased site disorder results from mixed cation occupancy with localized crystallographic strain and bond disorder. Compositions LaNdSmEuDy (δ A = 4.6) and LaNdSmEuYb (δ A = 6.0) produced a single pyrochlore phase and compositions SmDyYHoErYb (δ A = 2.8), LaYHoErYb (δ A = 6.2), and DyYHoErYb (δ A = 1.7) produced a single fluorite phase. High δ A compositions LaNdEuErYb (δ A = 6.9) and LaNdDyErYb (δ A = 7.2) produced a pyrochlore and fluorite phase mixture at 1700°C. Single phase was obtained for the latter composition at 2000°C. Of the single phase compositions calcined at 1700°C, LaNdSmEuYb and LaYHoErYb (both with largest δ A ) showed decomposition to mixed fluorite and pyrochlore phases during lower temperature anneals, indicating entropic stabilization. Comparison with prior work shows a temperature dependence of the critical δ A for phase stability, and compositions near it are expected to be entropy stabilized.

36 MATERIALS SCIENCE↗

Recent Progress to Understand and Improve Zeolite Stability in the Aqueous Medium

The work reviewed here attempts to summarize the growing literature on zeolite stability in hot liquid water. This required to first establish the nature, structure and interactions of the active sites in Brønsted and Lewis acidic microporous materials in the presence of liquid water. This understanding was then transferred to zeolite stability and catalyst deactivation. While early results correctly established Si–O–Si hydrolysis as the dominant pathway compared to the Si–O–Al hydrolysis observed in steaming, it also focused extensively on the positive role of framework and extra-framework Al in stabilizing zeolites. However, stability was instead found to more directly correlate with the number of internal structural defects and intraporous water concentration. Stabilization protocols for Brønsted acidic zeolites are described in detail. In the case of Lewis acidic zeolites, their inherent hydrophobic behavior (Si/M >100) makes them more resistant towards water, however, issues such as reversible carbonaceous species formation as well as irreversible metal leaching and fouling remain. Finally, we summarize the most important factors in designing robust and efficient zeolite catalysts made to withstand hot liquid water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Stability of Transition Metal Nitrides in Aqueous Environments: The Case of Molybdenum, Iron, Vanadium and Nickel Nitride

Analysis of the MoN, Mo 2 N, VN, Fe 2 N, Fe 4 N, Ni 3 N stability in the aqueous media was performed based on the thermodynamic data available in HSC Chemistry software. Our analysis show that among all the studied nitrides, cubic Mo 2 N is the most resistant while cubic VN is the least resistant to oxidation and decomposition. The change in temperature up to 100 °C does not significantly influence the formation potentials of transition metal oxides from nitrides; however, pH significantly affects the stability of the studied transition metal nitrides. In the case of Mo 2 N, MoN, and VN changing pH from acidic to neutral and alkaline decreases the stability of the nitrides and the oxide formation potentials shift to more negative values. Additionally, based on thermodynamics, orthorhombic Fe 2 N should be stable only in alkaline conditions, while cubic Fe 4 N and hexagonal Ni 3 N should be the most stable at pH ~ 7 and pH ~ 9. Changing pH from these values decreases the stability of both Fe 4 N and Ni 3 N and the formation of oxy-, hydroxy- species becomes thermodynamically more favorable. Overall, the limited stability of the metal nitrides places severe constraints for their use in aqueous electrocatalytic applications.

36 MATERIALS SCIENCE↗

Experimental Images and Videos of Foam Stability (Half-life)

The experimental data obtained in this project is the thermal stability data of various foams measured using the setup established at Temple University during this study. The setup is installed with a portable digital camera which can take images and videos of foam evolution at a given pressure and temperature condition. Consequently, the half-life data was recorded from the images/videos, which are used as a measure of the thermal stability for foams. Over the 3 years of this project, four different surfactants and five different stabilizing agents were studied. The surfactants are, Alfa Olefin Sulfonate (AOS), Sodium Dodecyl Sulphate (SDS), Tergitol (NP-40), and Cetyltrimethylammonium chloride (CTAC). The stabilizing agents are, guar gum, bentonite clay, crosslinking agents, silicon dioxide nanoparticles (60 to 70nm), and graphene oxide dispersions. Foam stability was evaluated at different temperatures between 100C and 200cC, while the foam generation pressure varied between atmospheric pressure (14.7 psi) and 1000 psi. The images are saved as .jpg file and videos are saved as .avi files.

15 GEOTHERMAL ENERGY↗

Feedback Control Strategy for Transient Stability Application

Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Phase Stability of Sm 2 (Fe, Al) 17 C x

Aluminum doping can improve the phase stability of metastable compound Sm 2 Fe 17 C x with a high carbon content (x > 1.5). We investigated the preferential site substitution of Al, chemical bonding, and structural stability in Sm 2 (Fe,Al) 17 C 3 using first-principle calculations. Our results reveal a strong correlation between the preferential substitution of Fe by Al and the atomic site chemical environment, which affects the overall phase stability. Specifically, Al preferentially occupies the 9d site in Sm 2 (Fe,Al) 17 C 3 . At the same time, Al prefers the site 6c in its parent phase Sm 2 (Fe,Al) 17 . Partial replacement of Fe with Al leads to a more negative formation energy, indicating enhanced thermodynamic stability. Crystal Orbital Hamilton Population (COHP) and Crystal Orbital Bond Index (COBI) analysis suggest that insertion of carbon weakens the bonding strength of Sm-Fe (18f) and Sm-Fe (18h), resulting in metastability of Sm 2 Fe 17 C x . Doping Al strengthens Al-Fe, Al-Sm, Sm-Fe (18f, 18h) and Fe–C bonding in Sm 2 (Fe,Al) 17 C 3 , as revealed by calculated COHP and COBI. These effects contribute to improved phase stability in the Al-doped 2:17 interstitial compound.

chemical bonding↗

An Experimental Investigation of the Effect of Propellers Used as Aerodynamic Brakes on Stability and Control

Tests were made of a model representative of a single-engine tractor-type airplane for the purpose of determining the stability and control effects of a propeller used as an aerodynamic brake. The tests were made with single-and dual-rotation propellers to show the effect of type of propeller rotation, and with positive thrust to provide basic data with which to compare the effects of negative thrust. Four configurations of the model were used to give the effects of tilting the propeller thrust axis down 5 deg., raising the horizontal tail, and combining both tilt and raised tail. Results of the tests are reported herein. The effects of negative thrust were found to be significant. The longitudinal stability was increased because of the loss of wing lift and increase of the angle of attack of the tail. Directional stability and both longitudinal and directional control were decreased because of the reduced velocity at the tail. These effects are moderate for moderate braking but become pronounced with full-power braking, particularly at high values of lift coefficient. The effects of model configuration changes were small when compared with the over-all effects of negative-thrust operation; however, improved stability and control characteristics were exhibited by the model with the tilted thrust axis. Raising the horizontal tail improved the longitudinal characteristics, but was detrimental to directional characteristics. The use of dual-rotation propeller reduced the directional trim charges resulting from the braking operation. A prototype airplane was assumed and handling qualities were computed and analyzed for normal (positive thrust) and braking operation with full and partial power. The results of these analyses are presented for the longitudinal characteristics in steady and accelerated flight, and for the directional characteristics in high- and low-speed flight. It was found that by limiting the power output of the engine (assuming the constant-speed propeller will function in the range of blade angles required for negative thrust) the stability and control characteristics may be held within the limits required for safe operation. Braking with full power, particularly at low speeds, is dangerous, but braking with very small power output is satisfactory from the standpoint of control. The amount of braking produced with zero power output is equal to or better than that produced by conventional spoiler-type brakes.

AIRPLANES, MILITARY↗

A formulation of stability for spacecraft formations

A formulation of stability for a set of spacecraft in formation flight is presented. First, a formation is defined in a precise mathematical form in terms of control interactions. Then, stability is formulated based on input-to-output stability with respect to a partitioning of the formation dynamics. This formulation of stability is shown to be useful in characterizing disturbance propagation in the formation as a function of the partition interconnection topology, and also in analyzing the robustness of sensing, communication, and control topologies. Stability results are presented for hierarchical, cyclic, and disturbance attenuating formations.

formation flyer↗

Noise-Resilient Quantum Machine Learning for Stability Assessment of Power Systems

Transient stability assessment (TSA) is a cornerstone for resilient operations of todays interconnected power grids. This paper is a confluence of quantum computing, data science and machine learning to potentially address the power system TSA issue. Here, we devise a quantum TSA (QTSA) method to enable scalable and efficient data-driven transient stability prediction for bulk power systems, which is the first attempt to tackle the TSA issue with quantum computing. Our contributions are three-fold: 1) A high expressibility, low-depth (HELD) quantum circuit is designed for accurate and noise-resilient TSA; 2) A quantum natural gradient descent algorithm is developed for efficient HELD circuit training; 3) A systematical analysis on QTSAs performance under various quantum factors is per-formed. QTSA underpins a foundation of quantum-enabled and data-driven power grid stability analytics. It renders the intractable TSA straightforward and effortless in the Hilbert space, and therefore provides stability information for power system operations. Extensive experiments on quantum simulators and real quantum computers verify the accuracy, noise-resilience, scalability and universality of QTSA.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Robust Power System Stability Assessment Against Adversarial Machine Learning-Based Cyberattacks via Online Purification

The increasing complexity associated with renewable generation brings more challenges to power system stability assessment (SA). Data-driven approaches based on machine learning (ML) techniques for stability assessment have received significant research interest and shown their promising performance. However, ML-based models are recognized to be vulnerable to adversarial disturbances, where a slight perturbation to power system measurements could lead to unacceptable errors. To address this issue, this paper develops a novel lightweight mitigation strategy, i.e., robust online stability assessment (ROSA), to enhance the ML-based assessment model against both white-box and the black-box adversarial disturbances (i.e., purification) in the online implementation. The ROSA involves a supervised learning-based module for the primary stability assessment and a self-supervised learning-based module. Further, the two modules are trained jointly with different objective (loss) functions and implemented in sequence. A suitable purification objective and various time-series data augmentation methods are designed for SA applications to tackle adversarial disturbances adaptively. Case studies are performed, and the comparative results have clearly illustrated the competitive, robust accuracy against various adversarial scenarios and verified the effectiveness of the proposed online purification strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗